Microsoft Window A2xx User Manual

User'sGuide  
Windows CE 5.0 Version  
for FUTRO A2xx Series  
Management by Scout Enterprise  
Build # 5  
August 2007  
©2007 by UniCon Software GmbH. All rights reserved  
Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form  
or by any means, electronic or mechanical, for any purpose, without the express consent of UniCon Software GmbH.  
Microsoft Windows CE is a registered trademark of Microsoft Corporation in the United States and/or other countries.  
Ericom and PowerTerm are registered trademarks of Ericom Software in the United States and/or other countries.  
All other Trade Names referred to are the Servicemark, Trademark or Registered Trademark of the respective manufacturers.  
Citrix, Independent Computing Architecture (ICA), Program Neighborhood, MetaFrame, and MetaFrame XP are registered trademarks  
or trademarks of Citrix Systems, Inc. in the United States and other countries.  
The end user takes full responsibility for his or her actions. Neither UniCon Software GmbH nor its partners assume liability for any  
errors or damage resulting from the information contained herein.  
User's Guide for A2xx with WinCe  
Build # 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Figures  
User's Guide for A2xx with WinCe  
Build # 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User's Guide for A2xx with WinCe  
Build # 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 About This Guide  
This documentation presents step-by-step directions to run the Windows CE Thin Client. For your  
convenience there are a few remarks about handling the dialog boxes:  
The dialog boxes are equipped with the buttons OK and in the upper right corner. To apply /  
save modifications you have to click OK. Alternatively press ENTER which both saves the  
modifications and closes the dialog at the same time. Click on only or press ESC to close the  
dialog without modifications to apply.  
1.1 Keyboard Shortcuts  
In general, the Windows keyboard shortcuts can be used, such as:  
CTRL+TAB  
CTRL+SHIFT+TAB  
SPACEBAR  
ENTER  
Move forward through tabs.  
Move backward through tabs.  
Select or clear the check box if the active option is a check box.  
Carry out the command for the active option or button, alternative for the  
click on OK and .  
ESC  
Cancel the current task rsp. close the dialog box without saving  
modifications.  
1.2 Hotkeys  
The Task hotkey enables you to switch between currently open applications or “tasks”.  
CTRL + ALT + : Left selection in the Applications bar  
CTRL + ALT + : Right selection in the Applications bar  
The terminal password authorization hotkey re-enables disabled settings.  
CTRL + ALT + Pos1 (HOME)  
The terminal password has to be entered.  
To show the Starter window (Terminal Connection Manager) on top of other windows:  
CTRL + ALT + End  
Holding the Shift key during boot, the device starts in VGA mode.  
User's Guide for A2xx with WinCe  
Build # 5  
0
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2 First Contact Wizard  
The Windows Thin Client Setup Wizard is used for the terminal's initial setup. The wizard runs  
when  
the client has never been configured before or  
in the General tab the check box "Reset the terminal to factory-default property settings" is  
activated to restart the terminal.  
There are eight dialog boxes for the Setup Wizard process. We show the most important ones.  
After the Welcome dialog Click Next to define whether you want the terminal to be managed by a  
Scout Enterprise manager or not, and to select the keyboard layout.  
Figure 1: Windows Thin Client Setup Wizard – Management and keyboard layout  
If you decided to be managed by Scout Enterprise, then you have to enter the IP name or IP  
address of the Scout manager in the next window. In addition you can modify the terminal name  
and fill in three info fields (e.g. department, room, phone…).  
User's Guide for A2xx with WinCe  
Build # 5  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 2: Windows Thin Client Setup Wizard – Management address  
Click Next and select the group you want to register your client in:  
Figure 3 Windows Thin Client Setup Wizard – Group from Manager  
User's Guide for A2xx with WinCe  
Build # 5  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 4 Windows Thin Client Setup Wizard – Completed (managed by Scout Enterprise)  
Click Finish to apply the specified settings and exit the wizard.  
If you deny to be managed, you get the option to modify the terminal name and show the network  
properties. The terminal name can be recognized by your server. The maximum length of the  
terminal name is 15 characters due to server limitation.  
Figure 5: Windows Thin Client Setup Wizard – Terminal Name  
User's Guide for A2xx with WinCe  
Build # 5  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Click Next to show and - if desired - modify the desktop area and refresh frequency.  
Figure 6: Windows Thin Client Setup Wizard – Desktop Area and Refresh Frequency  
Click Next to open the control panel (see chapter 4.4 for detailed description).  
Figure 7: Windows Thin Client Setup Wizard – Control Panel  
User's Guide for A2xx with WinCe  
Build # 5  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3 Terminal Connection Manager  
Note: When using the ‘Standard Shell’ you will find the connection manager by selecting  
Start Programs Connection Manager.  
The Terminal Connection Manager has two tabs:  
Application: shows the applications which have already been configured, if any, and offers you to  
connect to the application, to shutdown or to restart the terminal.  
Configuration: Here you can add…, edit… or delete an application. The Properties button allows  
you to set an application for Autostart. This will be shown in the Startup column of the Configure  
tab.  
Click Add… to define a new application:  
Figure 8: Configure tab, Add new application  
a new application in detail.  
User's Guide for A2xx with WinCe  
Build # 5  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Click Edit… to modify an existing application. It depends on the application which tabs are  
available and which settings can be modified.  
Editing an RDP application is described in chapter 5.4.1 Edit an RDP Application,  
Click the button Delete to delete the selected application. You are asked for confirmation: yes or  
no.  
Click Properties… to define the application properties.  
Figure 9: Configure tab, Define application properties  
Startup Options: Here you can set an application for Autostart. This will be shown in the Startup  
column of the Configure tab.  
Desktop Options: If you are using the standard shell, you can specify a desktop shortcut for an  
application.  
User's Guide for A2xx with WinCe  
Build # 5  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4 Terminal Properties  
4.1 General  
Starting from the Terminal Connection Manager press <F2> to open the Terminal Properties  
Window with the tabs  
General  
Display  
Diagnosis  
Control Panel  
Note: When using the ‘Standard Shell’ you will find the Terminal Properties Dialog (with tabs  
General, Display and Diagnosis) under Start Settings Setup Device and the Control Panel by  
selecting Start Settings Control Panel.  
Figure 10: Terminal Properties– General tab  
The General tab provides the terminal basic hardware configuration:  
OEM Name  
Product Name  
Product ID: this is an important information when you contact your supplier for technical  
support or free software upgrade  
Microsoft Windows CE Version  
Internet Explorer Version  
User's Guide for A2xx with WinCe  
Build # 5  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Remote Desktop Protocol Version  
Citrix ICA Client Version  
Ericom PowerTerm Version  
Terminal Name: Enter the terminal name which can be recognized by your server. The maximum  
length of the terminal name is 15 characters due to server limitation.  
Option: Reset the terminal to factory default property settings. Click on the check box to reset the  
terminal to its factory default settings.  
Click OK or press ENTER for the modifications to apply and close the window or press <Esc> to  
cancel the current modifications and close the dialog.  
4.2 Display  
This tab offers to modify your display as to:  
Desktop Area and Refresh Frequency  
Colors  
Screensaver  
Figure 11: Terminal Properties– Display tab  
User's Guide for A2xx with WinCe  
Build # 5  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.3 Diagnosis  
Shows IP address and other parameters, sets the debug level, shows and transfers system and  
log files and leads to Console and Ping  
Figure 12: Terminal Properties– Diagnosis tab with Ping window  
Console: offers the command prompt;  
Ping: allows you to check for the connection.  
User's Guide for A2xx with WinCe  
Build # 5  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4 Control Panel  
This is the tab to define the terminal settings.  
Figure 13: Terminal Properties– Control Panel  
4.4.1 Internet Options  
Change Internet Settings in the tabs:  
General: Start Page and Search Page, Define Cache Size, Clear Cache, Clear History  
Figure 14: Control Panel – Internet Options - General  
User's Guide for A2xx with WinCe  
Build # 5  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connection: Enter Proxy server address if required  
Figure 15: Internet Options – Connection  
Security: Settings for the different zones  
Figure 16: Internet Options – Security  
Privacy: Allow session cookies or not  
Figure 17: Internet Options – Privacy  
User's Guide for A2xx with WinCe  
Build # 5  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Advanced: Customize the options for accessibility and browsing  
Figure 18: Internet Options – Advanced  
Popups: Customize the behavior of popup windows  
Figure 19: Internet Options – Popups  
User's Guide for A2xx with WinCe  
Build # 5  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.2 Printers  
In the Control Panel double-click the Printers icon to open the "Add printer" dialog box. Double  
click on the "Add Printer" icon to open the Printer Wizard. This wizard provides four major steps to  
setup the printer.  
Step 1: Select the Printer Port  
By default there are 3 different printer ports: COM1, LPT1, Network, for your selection. Whenever  
you add another printer, LPT2 will show in the port list, even if connected via USB.  
Figure 20:Control Panel - Printers  
Step 2: Select the Printer Model  
Select the printer from the Manufacturers & Printers list.  
Note: If your printer is not in the list, enable “User Defined” check box.  
Figure 21:Control Panel – Printer Models  
User's Guide for A2xx with WinCe  
Build # 5  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Step 3: Name your Printer  
Figure 22:Control Panel – Printer Name  
1. Your printer is on the list.  
The printer you select will display in the "Printer name" field.  
2. Your printer is not on the list.  
If the printer is not in the list, please type the printer name which is identical with the  
printer name on the server.  
3. You select a network printer  
If you select a network printer, please enter precisely the printer name and network  
path.  
Step 4: Configure another printer, if required  
Step 5: Click Finish to complete the Printer Setup  
User's Guide for A2xx with WinCe  
Build # 5  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.3 ThinPrint Settings  
ThinPrint .print Client CE allows you to print directly from the terminal to network printers. Together  
with the Citrix MetaFrame application server software, this feature provides a powerful solution for  
remote offices and wireless LAN hotspots. With this ThinPrint Client a print job can be delivered  
over the Citrix ICA protocol & Microsoft RDP protocol to the device and from there directly to the  
network printer through TCP/IP protocol. So you do not any longer need a print server in addition  
to a network printer.  
To enable the ThinPrint Client double-click the icon in the Control Panel opening the Thin Print  
Settings. Choose whether to use TCP/IP or RDP/ICA protocol.  
Clicking ‘Thin Print Setup’ will open .print Client configuration. Fill in the adequate values in the  
tabs Setup, Assignment and Advanced, then you can use the ThinPrint Client after the terminal  
restart.  
Figure 23: ThinPrint Client CE – Setup  
Figure 24: ThinPrint Client CE - Assignment  
User's Guide for A2xx with WinCe  
Build # 5  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Add local port…  
Add local port…" to enter the printer name and printer port in the dialog box.  
Add network printer…:  
Click (shared) printers and double-click one of the listed printers. Enter the printer name  
and the printer's network path. A new network printer is installed by double clicking the  
NET0 printer icon.  
Advanced settings contain Bandwidth, Port number and Device Write Timeout in sec.  
Figure 25: ThinPrint Client CE - Advanced  
Bandwidth:  
Enter a bandwidth value which is the same or smaller than that set in .print Engine. If the value is  
larger or if Client Control is disabled at the server, server settings are applied.  
Enter 0 to retain server settings.  
Port number:  
Enter the port number where .print Client should receive incoming connections. Be sure that the  
TCP/IP port number is the same on both .print Client and server-side .print Engine. Otherwise,  
communication between the two .print components is impossible.  
Note: TCP/IP Port number is of course only relevant for printing over TCP/IP. The default port  
number is 4000.  
Quit Client:  
Click "Quit Client" to exit .print Client. (.print Client must be restarted before ThinPrint .print  
printing resumes).  
Click OK for all changes to apply without quitting .print Client. Some changes are only effective  
after having restarted .print Client.  
Click button to quit the dialog box without saving changes.  
User's Guide for A2xx with WinCe  
Build # 5  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.4 Keyboard  
The Repeat settings for the characters can be modified.  
Figure 26:Control panel – Keyboard Properties  
4.4.5 System  
The system properties window is divided into five tabs:  
General  
Memory  
Device Name  
Firmware  
Copyrights  
Most of them are self-explanatory, so this manual will not go into details except for the FIRMWARE  
tab.  
4.4.5.1 Firmware Update  
To update the terminal over the network, download an available image from the website  
www.myelux.com in the Download Area > Windows CE Images.  
At the client you have to select the protocol and fill in some fields.  
First of all select between:  
HTTP if the update server is an HTTP server. Enter the proxy IP address or name, and the  
proxy port number, if used (optional). To use Microsoft Internet Information server 6.0, you  
must define several new MIME types.  
FTP if the update server is an FTP server. Please consider that lower and upper case are  
crucial.  
Server:  
Path:  
Enter the IP address or name of the update server in the Server field.  
Enter the Path where the image file is located  
User:  
If you selected the FTP protocol it is mandatory to enter the user name.  
User's Guide for A2xx with WinCe  
Build # 5  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Password:If you selected the FTP protocol it is mandatory to enter the password.  
Image:  
Proxy:  
Enter the name of the new image file in the Image field.  
(optional) Enter proxy name or IP address if you selected HTTP Server. This field is  
disabled if you chose FTP.  
Proxy-Port:(optional) Enter proxy port number, if used and if you selected HTTP Server. This  
field is disabled if you chose FTP.  
You have the option to enable the check boxes "Check update on start" and "Ask user before  
update".  
The following figures show example settings and an Update Protocol.  
Figure 27: System Properties - Firmware  
Figure 28 System Properties - Firmware - Update Protocol  
User's Guide for A2xx with WinCe  
Build # 5  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.6 Display  
The Display Properties dialog allows to modify the appearance, i.e. the color scheme of the  
applications windows.  
Figure 29: Display Properties  
4.4.7 Mouse  
Set the double-click sensitivity for both speed and physical distance between clicks.  
Set the mouse acceleration and swap mouse buttons. Swapping mouse buttons requires a device  
restart to take effect.  
User's Guide for A2xx with WinCe  
Build # 5  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.8 Volume and Sounds  
Move the slide from Soft to Loud to modify the volume.  
4.4.9 Date/Time  
This dialog allows to set the current time and the time zone as well as the option to automatically  
adjust the clock for daylight saving time.  
Further, an SNTP Time Server may be selected or added by entering IP name or address.  
Figure 30: Date/Time Properties  
4.4.10 Regional Settings  
Specify and customize your regional settings which will affect format numbers, currency,  
time and dates in locally installed programs.  
The User Interface Language cannot be modified, it is available in English (US) only.  
Select all desired Input Languages from the list.  
Figure 31: Regional Settings  
User's Guide for A2xx with WinCe  
Build # 5  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.11 VNC Settings  
Set password requested for mirroring the terminal.  
Enable the check boxes  
Launch on startup: if you wish to allow mirroring from the very start of the terminal.  
Enable remote input: to allow input from remote  
Query on connection: Request to Thin Client user  
Figure 32: VNC Settings  
Figure 33: VNC Settings – Query on connection  
4.4.12 Auto Shutdown  
The terminal provides automatic shutdown when all connections have been closed. It is convenient  
for some special applications. Factory default: Disabled  
4.4.13 USB Storage Management  
USB Storage devices include USB Hard Disk, USB Floppy, USB Flash Disk and USB CD-ROM.  
They can either be enabled or disabled. Factory default: Enabled.  
4.4.14 Touch Setup  
Allows to change the global ELO USB TouchScreensettings.  
The “Calibrate” button will be active when the USB touch screen is connected and the “Enable  
Comport TouchScreen” isn’t checked.  
Touching the screen is equivalent to clicking and releasing the mouse button.  
User's Guide for A2xx with WinCe  
Build # 5  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.15 Network Files  
Network files can be mapped, if required, to save files from the local Internet Explorer.  
Figure 34: Network File Mapping  
4.4.16 Global ICA Client Settings  
The four tabs to define the global ICA Client settings are desribed in short, for detailed information  
please consult the ICA WinCE Guide on http://support.citrix.com in the download area.  
Keyboard Shortcuts: can be customized or disabled  
Figure 35: Global ICA Client Settings – Keyboard Shortcuts  
User's Guide for A2xx with WinCe  
Build # 5  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Preferences:  
Enter the serial number and define your default window colors.  
PNAgent:  
Option: Enable and specify server  
Option: Force PNAgent on Reboot  
Select from drop-down list when to apply Windows key combinations.  
Figure 36: Global ICA Client Settings – Preferences  
Server Location:  
Either select a server group from the drop-down list or  
add a new server address or  
rename server location group.  
Figure 37: Global ICA Client Settings – Server Location  
User's Guide for A2xx with WinCe  
Build # 5  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Firewall Settings: Enter proxy address if required to assure a secure connection.  
Figure 38: Global ICA Client Settings – Firewall Settings  
4.4.17 ICA Options  
This allows to map local disk drives and modify the mouse timer settings as well as the scroll  
speed for ICA sessions.  
Figure 39:ICA Options  
User's Guide for A2xx with WinCe  
Build # 5  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.18 Network and Dial-Up Connections  
Shows the parameters of the network card or defines a new network connection.  
4.4.18.1 PCI-RTCENIC1  
IP Address: This is to enter an IP address or to obtain an IP address from the DHCP server.  
Figure 40:Network Connection - IP Address  
Name Servers: This is to enter addresses from name servers.  
Figure 41:Network Connection – Name Servers  
User's Guide for A2xx with WinCe  
Build # 5  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Link speed: The link speed can be set here. Modifications take effect after the next restart. If the  
speed has been 1Gbit/s before modification (setting: 1Gbit/s or Auto) and is to be reduced, then  
the device must be shut down and restarted. In case a required speed should not be available, the  
next lower speed is chosen.  
Figure 42:Network Connection – Link speed  
4.4.18.2 Make New Connection  
A new VPN connection can be created here. If the Scout server is to provide the connection select  
the connection type PPTP.  
Figure 43 Make new connection  
User's Guide for A2xx with WinCe  
Build # 5  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.19 LPD Settings  
Figure 44:LPD Server Settings  
Click Start or Stop to start or stop the LPD Server.  
If Launch on startup is enabled the LPD Server will always be started during the start of the  
device.  
The names of the printer queues correspond to the names of the printers.  
4.4.20 Shell Settings  
Figure 45:Shell Settings  
Here you define, whether to work with the Thin Client Shell or the Standard Shell.  
Restart the device for modifications to take effect.  
By default the device works with the Standard Shell.  
User's Guide for A2xx with WinCe  
Build # 5  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.21 Licenses  
The window contains a list of the licensed products and the state of the licenses  
(Gained / Not gained).  
Figure 46:Licenses  
Request license from server: The Scout server gets a request for a license. Clicking the button  
'Release License' returns the license to the Scout server.  
If you do not use Scout, i.e. no license is available on the Scout server, switch to Input local  
license key, in order to enter a local license key.  
Provided there is a valid local license, this may be returned to the server by clicking "Release  
License".  
4.4.21.1 License Activation  
To activate licenses for products such as PowerTerm you have two options.  
1. Activate the license base key on www.myelux.com > Product Activation Center, using Scout  
Enterprise (Version A) or  
2. Activate the license base key on www.myelux.com > Product Activation Center by splitting  
(Version B) the license key into individual licenses bound to the Host ID of the client, and to be  
entered locally.  
The procedure for both versions are written on the license certificate you get with the license base  
key.  
Licenses for PowerTerm and Scout Enterprise are to be ordered from Fujitsu Siemens Computers.  
The order numbers are: PowerTerm: S26361-F2600-L144; Scout Enterprise: S26361-F2600-L148.  
User's Guide for A2xx with WinCe  
Build # 5  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4.4.22 Security Management  
Figure 47:Device Password  
To modify security settings a device password is required. Having entered this password the  
security dialog opens.  
This is to enable or disable the right of access to the Setup dialog and the tabs ‚Configuration’ of  
the Connection Managers. Further, the device password can be modified here.  
The modifications take effect immediately.  
Figure 48:Security Management  
User's Guide for A2xx with WinCe  
Build # 5  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5 Configuration of Applications  
5.1 Add New Application – Microsoft Remote Desktop Client  
From the Terminal Properties window click OK to switch to the Terminal Connection Manager and  
open the tab Configuration.  
Click Add… to open the dialog New Application.  
Figure 49 Terminal Connection Manager – Configuration – Add new application  
User's Guide for A2xx with WinCe  
Build # 5  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5.1.1 WTS Connection Wizard  
This chapter describes the configuration of a new application of the type RDP.  
Step 1: Enter name for the new connection and the server you want to connect to.  
Figure 50 WTS Connection Wizard – Step 1  
Step 2: For automatic logon you have to enter your user name, password and domain.  
Figure 51 WTS Connection Wizard – Step 2  
User's Guide for A2xx with WinCe  
Build # 5  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Step 3: On connection the default display is the Desktop, enter an application file name, if you want  
to start an application on connection.  
Figure 52 WTS Connection Wizard – Step 3  
Step 4: Click Finish to save your new connection.  
Figure 53 WTS Connection Wizard – Step 4  
User's Guide for A2xx with WinCe  
Build # 5  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5.2 Add New Application - Media Player  
From the Terminal Properties window click OK to switch to the Terminal Connection Manager and  
open the tab Configuration  
Click Add… to open the dialog New Application, and choose Media Player from the drop-down  
list.  
Figure 54 Configuration – Add New Application – Media Player  
5.3 Add New Application - Internet Explorer  
Click Add… to open the dialog New Application, and choose Microsoft Internet Explorer from the  
drop-down list.  
Figure 55 Configuration – Add New Application – Microsoft Internet Explorer  
For the Internet Settings and Options see chapter 4.4.1 Internet Options.  
User's Guide for A2xx with WinCe  
Build # 5  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5.4 Edit Connections  
5.4.1 Edit an RDP Application  
Once the application has been added, it can be edited any time. As an example, this chapter  
describes the edit procedure of an RDP Application.  
In the General tab:  
Connection:  
Define/Edit Name and Server Address  
Automatic Logon:  
To enable this you have to enter Username, Password, Domain  
Figure 56 Edit Connection – General tab  
Using the RDP Local Resources tab, you can configure the terminal's  
Remote computer sound  
Local devices  
o Disk drives: enable local USB port mapping. It supports USB disk drives, such as  
USB FDD, HDD, Flash Disk and CD-ROM.  
o Printers: enables local parallel port mapping. It supports both parallel printers from  
LPT1 and USB printers from USB port.  
o Serial ports: enables local serial ports mapping.  
o Smart cards: enables local SmartCard mapping, if any.  
User's Guide for A2xx with WinCe  
Build # 5  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 57 Edit Connection – Local Resources tab  
Using the RDP Programs tab, you can enter a file name for the application to run on connection.  
Figure 58 Edit Connection – Programs tab  
User's Guide for A2xx with WinCe  
Build # 5  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Using the RDP Experience tab, you can choose your connection speed to optimize performance.  
Figure 59 Edit Connection – Experience tab  
6 Standard Shell  
The dialogs described above may also be opened from a Standard Shell. The Standard Shell is  
activated in the Control Panel ‚Shell Settings’.  
Starting Programs from the Windows menu offers to start the defined connections, the Connection  
Manager as well as service programs.  
Figure 60 Programs – Connections  
User's Guide for A2xx with WinCe  
Build # 5  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Selecting Settings from the Windows menu the 'Setup Device' dialog and the 'Control Panel' can  
be opened.  
Figure 61 Settings  
The menu option Run enables to start executable files.  
The button ‚Browse’ opens the File Explorer.  
Figure 62 Run  
The menu option Shutdown opens this dialog:  
Figure 63 Shutdown  
User's Guide for A2xx with WinCe  
Build # 5  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7 Index  
accessibility.........................................................13  
Add printer ..........................................................14  
Application ............................................................6  
automatic logon ..................................................32  
Bandwidth...........................................................17  
browsing .............................................................13  
Configuration  
Keyboard  
Repeat............................. 18  
keyboard layout.................................................... 2  
license................................................................ 29  
Management........................................................ 2  
Media Player  
add application................ 34  
add.................................... 6  
Mouse  
delete................................ 6  
sensitivity ........................ 20  
edit .................................... 6  
Network file mapping ......................................... 23  
Ping.................................................................... 10  
Printer Model................................................ 14, 15  
Printer Port......................................................... 14  
Properties............................................................. 6  
Protocol  
New Application.............. 31  
Console...............................................................10  
control panel .........................................................5  
cookies................................................................12  
Date/Time ...........................................................21  
SNTP .............................. 21  
update............................. 19  
Desktop Area........................................................5  
Diagnosis  
Proxy.................................................................. 19  
Query ................................................................. 22  
RDP Experience ................................................ 37  
RDP Local Resources........................................ 35  
RDP Programs................................................... 36  
Refresh Frequency .............................................. 5  
Regional Settings  
Console........................... 10  
Ping................................. 10  
Display  
Colors................................ 9  
Screensaver...................... 9  
Display Properties...............................................20  
ELO USB TouchScreen......................................22  
F2..........................................................................8  
factory-default.......................................................2  
Firewall Settings .................................................25  
FIRMWARE ........................................................18  
Firmware Update...............................................18  
FTP .....................................................................18  
General.................................................................8  
Global ICA Client Settings..................................23  
keyboard shortcuts ......... 23  
InputLanguages .............. 21  
UserInterfaceLanguage .. 21  
Scout Enterprise manager................................... 2  
Server Location.................................................. 24  
Setup Wizard ....................................................... 2  
shortcuts .............................................................. 1  
system properties............................................... 18  
terminal  
settings............................ 11  
terminal name ...................................................... 4  
Terminal Properties.............................................. 8  
ThinPrint............................................................. 16  
Advanced........................ 16  
Hotkeys.................................................................1  
HTTP...................................................................18  
Internet  
Assignment ..................... 16  
Advanced........................ 12  
Setup............................... 16  
Connection...................... 12  
update................................................................ 18  
USB  
General........................... 11  
Popups............................ 12  
storage management...... 22  
Privacy............................ 12  
VNC Settings ..................................................... 22  
volume ............................................................... 21  
Welcome.............................................................. 2  
WTS Connection Wizard.................................... 32  
Security........................... 12  
Internet Explorer  
add application................ 34  
User's Guide for A2xx with WinCe  
Build # 5  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Kustom Stereo Amplifier Dual 30 RC User Manual
Learning Resources Baby Toy LER 2434 User Manual
Lincoln Electric Welder WC 474 User Manual
Lincoln Electric Welding System K278 1 User Manual
Lucent Technologies Network Card 8 Port DS3 E3 User Manual
Makita Chainsaw UC3510A User Manual
Master Bilt Refrigerator BSD 24SFA User Manual
McCulloch Pole Saw 41BZ015Q077 User Manual
Mercedes Benz Car Amplifier Audio 50 User Manual
MEY Equipment Lawn Mower Residential Cylinder Mower User Manual