Introduction  
Thank you for selecting a Meade Instruments 5-channel  
thermo-hygro sensor!  
Meade Instruments is the world’s leading designer and  
manufacturer of telescopes for professional and amateur  
astronomers – famous for its innovative, high performance  
telescopes at affordable prices. Meade Instruments now  
brings that same passion innovation and high performance to  
its own line of precision, feature rich weather stations.  
In this package you will find:  
• One Five-Channel Remote Thermo-hygrometer  
(transmitter) (TS34C-M)  
• One User Manual  
Standard Package Contents  
Picture  
Components  
Thermo Hygrometer Sensor  
Installation  
All data measured by this remote sensor is transmitted to the  
main unit wirelessly, with the operating range up to 328 feet  
(100 meters) in the open area.  
Remote thermo-hygrometers (temperature & humidity  
sensors) can be placed indoors or outdoors, depending on the  
area where the temperature and humidity are intended to be  
measured. If you intend measuring outdoor temperature and  
humidity, place the remote sensor outdoors.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: It is critical to power up and test communication  
between the remote sensor and the main unit BEFORE  
permanently mounting them outside.  
Before you begin  
• We recommend using alkaline batteries for the remote  
thermo-hygrometer when temperatures are above 32ºF  
(0ºC) and lithium batteries when temperatures are below  
32ºF (0ºC).  
• Avoid using rechargeable batteries. (Rechargeable batteries  
cannot maintain correct power requirements).  
• Insert batteries before first use, matching the polarity in the  
battery compartment  
• Remove protective plastic screen from LCD display (if  
any).  
• During an initial setup, place the main unit close to the  
remote sensor.  
• After reception is established (the remote readings will  
appear on the main unit's display), position the remote  
sensor and the main unit within the effective transmission  
range of up to 328 feet (100 meters). Ideally they should be  
placed within the line of sight of the main unit.  
• Transmission range may be affected by trees, metal  
structures and electronic appliances.  
• The effective operating range may be influenced by the  
surrounding building materials and how the receiver (main  
unit) and transmitters (weather sensors) are positioned.  
• Place the remote thermo-hygrometer so that it faces the  
main unit (receiver), minimizing obstructions such as  
doors, walls and furniture.  
Note: When the temperature falls below freezing, the  
batteries in the outdoor remote thermo-hygrometers may  
have reduced voltage supply and a shorter effective range.  
We recommend using lithium batteries at temperatures of  
32ºF (0ºC) and below.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features  
• LCD display of measured temperature and humidity  
• Five (5) transmission channels selection  
• Case can be wall mounted using built-in hanger  
E
D
1
C
A
B
A. LED INDICATOR  
• Flashes once when the remote sensor transmits a reading  
to the main unit.  
• Flashes twice when battery power is low.  
B. BATTERY COMPARTMENT  
Holds two AA-size batteries  
C. RESET  
Resets all readings  
D. CHANNEL SWITCH  
Selects the desired channel from 1 to 5  
E. WALL-MOUNT RECESSED OPENING  
Keeps the remote sensor on the wall  
Note: Install the batteries and select the channel before  
mounting the sensor.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Battery installation  
• Remove the screws from the battery compartment with a  
small Phillips screwdriver.  
• Set the channel 1 through 5. The switch is located in the  
battery compartment. Channel 1 is typically selected if only  
one remote thermo-hygrometer is being used.  
• Install 2 "AA" size alkaline batteries (not included)  
matching the polarities shown in the battery compartment.  
• Replace the battery compartment door and secure the screws.  
• Secure the remote thermo-hygrometer in the desired location.  
Mounting  
• The remote thermo-hygrometer can be placed on the flat  
surface or mounted on the wall in vertical position  
• Use the wall mount hardware and screws provided when  
mounting the remote thermo-hygrometer on the wall  
Placement tips:  
• The remote thermo-hygrometer should be placed in the area  
with a free air circulation and sheltered from the direct  
sunlight and an extreme weather conditions.  
• Ideally, place the remote thermo-hygrometer above the  
natural surfaces (such as a grassy lawn).  
• Avoid placing the remote thermo-hygrometer near sources  
of heat such as chimneys and heating elements.  
• Avoid any areas collecting and radiating a heat from the sun,  
such as metal, brick or concrete structures, paving, patios  
and decks.  
• The international standard for the valid air temperature  
measurements is 4 feet (1.25meters) above the ground.  
Note: To display the readings from the remote thermo-  
hygrometer you must own the main display unit of the  
Meade Professional Weather Station TE923W-M, model  
number TE923W-M. Additionally it will work with all other  
Meade weather station models.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
Q: "The remote sensor display shows dashes "---""  
A: Press the RESET opening with a paper clip or similar tool.  
If this does not work, check the batteries and replace them.  
Q: "Main unit display in temperature and humidity portion  
shows dashes "---""  
A: The display will show "- - -" when the wireless connection  
with the remote thermo-hygrometer is lost for 15 minutes  
Check or replace the batteries in remote sensor. Then press and  
hold DOWN button on the main unit to force a search for the  
remote signals.  
If this does not work, check the wireless transmission path from  
the remote thermo-hygrometer to the main unit and change their  
locations if necessary.  
The following may be the cause of reception problems:  
• The remote thermo-hygrometer and a main unit are too far  
from each other.  
• The signal shielding materials, such as metal surfaces,  
concrete walls or dense vegetation, are in the path of  
transmission.  
• There is interference from the wireless devices (such as  
cordless phones, radio headsets and baby listening devices)  
and electronic appliances.  
Precautions  
This product is engineered to give you years of satisfactory  
service if handled carefully. Here are a few precautions:  
• Do not immerse the units in water.  
• Do not clean the units with abrasive or corrosive materials.  
They may scratch the plastic parts and corrode the electronic  
circuits.  
• Do not subject the product to excessive force, shock, dust,  
temperature, or humidity, which may result in malfunctions,  
shorter lifespan, damaged batteries, and damaged parts.  
• Do not tamper with the product's internal components.  
Doing so will invalidate the warranty and may cause damage.  
The product contains no user-serviceable parts.  
• Use only fresh batteries. Do not mix new and old batteries.  
• Read the user's manual thoroughly before operating the product.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Radio Frequency: 433 MHz  
RF Reception range: 328 feet (100 m)  
Temperature  
Range: -40ºF to 122ºF (-40ºC to 50ºC)  
Resolution: 0.2ºF (0.1ºC)  
Accuracy: 2ºF (1ºC)  
Transmitting Interval: around 47 seconds  
Humidity  
Operating Range: 0% to 99%  
Resolution: 1%  
Accuracy: 5%  
Sampling Interval: 10 seconds  
Transmitting Interval: around 47 seconds  
Power: 2 x UM-3 or AA 1.5V battery  
Battery life (alkaline): over 12 months  
Weight (without batteries): 2.29oz (65g)  
Dimensions: 2.37(L) x 4(H) x 1(D) inches /  
60(L) x 101(H) x 25(D) mm  
FCC STATEMENT  
This device complies with Part 15 of the FCC Rules. Operation  
is subject to the following two conditions: (1) This device may  
not cause harmful interference, and (2) This device must accept  
any interference received, including interference that may cause  
undesired operation.  
Warning: Changes or modification to this unit not expressly  
approved by the party responsible for compliance could void  
the user's authority to operate the equipment.  
NOTE: This equipment had been tested and found to comply  
with the limits for a Class B Digital device, pursuant to Part 15  
of the FCC Rules. These limits are designed to provide  
reasonable protection against harmful interference in a  
residential installation. This equipment, installed and used in  
accordance with the instructions, may cause harmful interference  
to radio communications.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
There is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause harmful  
interference to radio or television reception, which can be  
determined by turning the equipment off and on, the user is  
encouraged to improve or correct turning the interference by  
one or more of the following measures:  
• Reorient or relocate the receiving antenna  
• Increase the separation between the equipment and receiver.  
• Connect the equipment to an outlet on a circuit different  
from that to which the receiver is connected.  
• Consult the dealer or an experienced radio / TV technician  
for help.  
DECLARATION OF CONFORMITY  
We  
Name: Meade Instruments Corporation  
Address: 27 Hubble, Irvine, CA92618  
Telephone No.: 1-949-451-1450  
declare that the product  
Product No.: TS34C-M  
Product Name: Five-channel Remote Thermo-Hygrometer  
Manufacturer: Hideki Electronics Ltd.  
Address: Unit 2304-06, 23/F Riley House, 88 Lei Muk Road,  
Kwai Chung, New Territories, Hong Kong  
is in conformity with Part 15 of the FCC Rules. Operation is  
subject to the following two conditions:  
This device may not cause harmful interference.  
This device must accept any interference received, including  
interference that may cause undesired operation.  
The information above is not to be used as a contact for  
support or sales. Please call our customer service hotline  
(refer to the Standard Warranty Information) for all  
injuries instead.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
BATTERY SAFETY INSTRUCTIONS  
• Always purchase the correct size (2 x 1.5V AA, 15A/15AC  
ANSI, LR6 IEC), (2 x ANSI/NEDA-5004LC, IEC-CR2032)  
and grade of battery most suitable for the intended use.  
• Replace all batteries of a set at the same time.  
• Clean the battery contacts and also those of the device prior  
to battery installation.  
• Ensure the batteries are installed correctly with regard to  
polarity (+ and -).  
• Remove the batteries from any weather station which is not  
to be used for an extended period of time.  
• Remove used batteries promptly.  
• Do not mix old batteries with new batteries.  
• Do not mix alkaline, lithium, standard (Carbon Zinc), or  
rechargeable (Nickel Cadmium) batteries.  
Caution:  
• If batteries or parts are swallowed, see a doctor immediately.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STANDARD WARRANTY INFORMATION  
This product is warranted by Meade Instruments Corp. (MIC)  
to be free of defects in materials and workmanship for a  
period of ONE YEAR from date of original retail purchase in  
the U.S.A. MIC will repair or replace the product, or part  
thereof, found upon inspection by MIC to be defective,  
provided the defective part or product is returned to MIC,  
freight prepaid, with proof of purchase. This warranty applies  
to the original purchaser only and is non-transferable. Meade  
products purchased outside North America are not included  
in this warranty.  
RGA Number Required: Prior to the return of any product  
or part, a Return Goods Authorization (RGA) number must  
be obtained by writing to Meade's Customer Service  
Department or by calling 800-626-3233. Each returned part  
or product must include a written statement detailing the  
nature of the claimed defect, as well as the owner's name,  
address, phone number, and a copy of the original sales  
invoice.  
This warranty is not valid in cases where the product has been  
abused or mishandled, where unauthorized repairs have been  
attempted or performed, or where depreciation of the product  
is due to normal wear-and-tear. MIC specifically disclaims  
special, indirect, or consequential damages or lost profits,  
which may result from a breach of this warranty. Any implied  
warranties which cannot be disclaimed are hereby limited to a  
term of one year from the date of purchase by the original  
retail purchaser. This warranty gives you specific rights. You  
may have other rights which vary from state to state.  
MIC reserves the right to change product specifications or to  
discontinue products without prior notice.  
This warranty supersedes all previous Meade product  
warranties.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Meade Instruments Corp.  
27 Hubble  
Irvine, CA 92618 U.S.A.  
© 2010 Meade Instruments Corporation. All Rights Reserved.  
All user manual contents and information are subject to change.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Kustom Stereo Amplifier Wav 1000 User Manual
Kuzma Turntables Turntable Kuzma Stabi Reference Turntable User Manual
La Crosse Technology Weather Radio WS 9020U User Manual
Lennox Hearth Indoor Fireplace 875027M User Manual
Life Fitness Bicycle LC 6500 User Manual
LOREX Technology Security Camera SG7610 Series User Manual
Magic Chef Microwave Oven MCD990BF User Manual
Magnavox VCR VRU542AT User Manual
Manitowoc Ice Air Compressor C 0200 User Manual
Melissa Hair Dryer 635 085 User Manual