Maytag Water Heater HV640HBVITCGA User Manual

Series Six  
POWER VENT  
GAS WATER HEATER  
USER’S GUIDE  
CANADIAN  
MANUAL  
FOR POTABLE WATER HEATING ONLY  
NOT SUITABLE FOR SPACE HEATING  
• Safety Instructions  
• Installation  
• Operation  
NOT FOR USE IN  
• Care and Maintenance  
• Troubleshooting  
• Parts List  
MANUFACTURED (MOBILE) HOMES  
Model Numbers  
HV640YBVITCGA  
HV650YBVITCGA  
HV640HBVITCGA  
HV650HBVITCGA  
C3 Technology® Gas Water Heaters meet  
the new ANSI Z21.10.1 standard that deals  
with the accidental or unintended ignition  
of flammable vapors, such as those  
emitted by gasoline.  
For Your Safety  
AN ODORANT ISADDEDTO THE GAS USED BYTHIS  
WATER HEATER.  
PRINTED IN THE U.S.A. 1005  
PART NO. 185376-000  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY PRECAUTIONS  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
SAFE INSTALLATION, USE AND SERVICE.................................................................................................................................... 2  
SAFETY PRECAUTIONS ................................................................................................................................................................. 3  
TABLE OF CONTENTS .................................................................................................................................................................... 4  
CUSTOMER RESPONSIBILITIES ................................................................................................................................................... 5  
PRODUCT SPECIFICATIONS ......................................................................................................................................................... 5  
MATERIALS AND BASIC TOOLS NEEDED .................................................................................................................................... 6  
TYPICAL INSTALLATION .............................................................................................................................................................. 7-8  
INSTALLATION INSTRUCTIONS .............................................................................................................................................. 9-22  
Removing the Old Water Heater ............................................................................................................................................. 9  
Facts to Consider About the Location .............................................................................................................................10-11  
Insulation Blankets................................................................................................................................................................. 11  
Combustion Air and Ventilation for Appliances Located in Unconfined Spaces ............................................................. 11  
Combustion Air and Ventilation for Appliances Located in Confined Spaces ............................................................11-12  
Water Piping ...................................................................................................................................................................... 13-14  
Temperature-Pressure Relief Valve ..................................................................................................................................... 14  
Gas Piping............................................................................................................................................................................... 15  
Sediment Traps ...................................................................................................................................................................... 16  
Filling the Water Heater ......................................................................................................................................................... 16  
Blower Assembly Installation ................................................................................................................................................ 16  
Vent Connections to Blower Assembly ................................................................................................................................. 17  
Venting and Installation ................................................................................................................................................... 17-18  
Condensation ......................................................................................................................................................................... 18  
Maximum Vent Lengths .......................................................................................................................................................... 18  
Venting ..................................................................................................................................................................................... 19  
Vent Terminal Installation ................................................................................................................................................ 19-20  
Vertical Vent Through Roof..................................................................................................................................................... 20  
Vertical Vent Restrictions ....................................................................................................................................................... 20  
Vent Pipe Preparation ...................................................................................................................................................... 21-22  
OPERATING INSTRUCTIONS................................................................................................................................................. 23-24  
Lighting and Operating Label ............................................................................................................................................... 23  
Temperature Regulation ........................................................................................................................................................ 24  
FOR YOUR INFORMATION ............................................................................................................................................................ 25  
Start Up Conditions ................................................................................................................................................................ 25  
Operational Conditions.......................................................................................................................................................... 25  
SERVICE AND ADJUSTMENT ................................................................................................................................................. 26-27  
Venting System Inspection .................................................................................................................................................... 26  
Burner Operation and Inspection ......................................................................................................................................... 26  
Burner Cleaning ..................................................................................................................................................................... 26  
Housekeeping ........................................................................................................................................................................ 26  
Anode Rod Inspection ............................................................................................................................................................ 27  
Temperature-Pressure Relief Valve Operation ................................................................................................................... 27  
Draining ................................................................................................................................................................................... 27  
Drain Valve Washer Replacement ........................................................................................................................................ 27  
Service ..................................................................................................................................................................................... 27  
LEAKAGE CHECKPOINTS ............................................................................................................................................................ 28  
TROUBLESHOOTING GUIDELINES ...................................................................................................................................... 29-30  
PARTS ORDER LIST...................................................................................................................................................................... 31  
WARRANTY ..................................................................................................................................................................................... 32  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
CUSTOMER RESPONSIBILITIES  
Thank You for purchasing a Maytag water heater. Properly installed  
of the water heater and your safety. Since we cannot put everything  
on the first few pages, READ THE ENTIRE MANUAL BEFORE  
ATTEMPTING TO INSTALLOROPERATE THE WATER HEATER.  
and maintained, it should give you years of trouble free service. It is  
strongly suggested that this new water heater be professionally  
installed, contact Maytag Customer Service (1-800-788-8899) for  
recommended installers.  
2. The installation must conform with these instructions and the local  
code authority having jurisdiction. In the absence of local codes,  
installations shall comply with the Natural Gas and Propane Installation  
Code CAN/CSA B149.1 and the Canadian Electric Code CSA C22.1.  
These publications are available from Canadian Standards  
Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario,  
Canada L4W 5N6.  
Abbreviations Found In This Instruction Manual:  
• CSA- Canadian StandardsAssociation  
• ANSI -American National Standards Institute  
• ASME -American Society of Mechanical Engineers  
• UL - Underwriters Laboratories Inc.  
3. The water heater when installed must be grounded in accordance  
with the local codes, or in the absence of local codes, the Canadian  
Electric Code CSA C22.1.  
This gas-fired water heater is listed by Underwriters Laboratories Inc.  
underAmerican National Standard/CSAStandard for Gas Water Heaters  
ANSI Z21.10.1 • CSA 4.1 (current edition).  
4. If after reading this manual you have any questions or do not  
understand any portion of the instructions, call the local gas utility or  
Maytag Customer Service at 1-800-788-8899 for an authorized  
servicer.  
PREPARING FOR THE INSTALLATION  
1. Read the “Safety Precautions” section, page 3 of this manual first  
and then the entire manual carefully. If you don’t follow the safety  
rules, the water heater will not operate properly. It could cause  
DEATH, SERIOUSBODILYINJURYAND/ORPROPERTYDAMAGE.  
5. Carefully plan the place where you are going to put the water heater.  
Correct combustion, vent action, and vent pipe installation are very  
important in preventing death from possible carbon monoxide  
poisoning and fires.  
This manual contains instructions for the installation, operation, and  
maintenance of the gas-fired water heater. It also contains warnings  
throughout the manual that you must read and be aware of. All  
warnings and all instructions are essential to the proper operation  
Examine the location to ensure the water heater complies with the  
“Facts to ConsiderAbout the Location” section in this manual.  
PRODUCT SPECIFICATIONS  
TANK  
CAPACITY  
IN GALS.  
(LTRS)  
RECOVERY  
MINIMUM  
VENTPIPE  
INCHES  
(mm)  
INPUT  
RATE  
RATE GALS.  
DIAMETER  
INCHES  
DIMENSIONSIN  
INCHES(mm)HEIGHT  
TOJACKETTOP  
55 (1,397)  
MODEL  
TYPEOF  
GAS  
PERHOUR  
NUMBER  
(Btu/hr)  
40,000  
40,000  
40,000  
40,000  
@9FRISE  
(mm)  
HV640YBVITCGA 40 (151)  
HV650YBVITCGA 50 (189)  
HV640HBVITCGA 40 (151)  
HV650HBVITCGA 50 (189)  
NATURAL  
NATURAL  
PROPANE  
PROPANE  
44  
44  
44  
44  
2 (51)  
18 1/2 (470)  
20 (508)  
18 1/2 (470)  
20 (508)  
2 (51)  
56 3/4 (1,441)  
55 (1,397)  
2 (51)  
2 (51)  
56 3/4 (1,441)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
MATERIALS AND BASIC TOOLS NEEDED  
Accessories  
To simplify the installation Maytag has available the installation parts shown below. You may or may not need all of these accessories depending on  
your type of installation. Call Maytag Customer Service at 1-800-788-8899 for an authorized installer.  
EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS  
AVAILABLE IN 2 GALLONS (7.6 LITERS), Part No. 66001013AND 5  
GALLONS (18.9 LITERS), Part No. 66001014 CAPACITY.  
DRAIN PANS AVAILABLE IN 22” (559 mm) DIAMETER (PART NO.  
66001011) FOR WATER HEATERS HAVINGA DIAMETER 20” (508  
mm) OR LESS, 24” (610mm) DIAMETER (PART NO. 66001105) FOR  
WATER HEATERS HAVINGADIAMETER 22” (559 mm) OR LESSAND  
28(711mm)DIAMETER(PARTNO. 66001012)FORWATERHEATERS  
HAVINGADIAMETER 26” (660 mm) OR LESS.  
Additional Tools Needed  
When Sweat Soldering  
Tools  
You may or may not need all these tools, depending on your type of  
installation. These tools can be purchased at your local hardware store.  
• Tubing Cutters or Hacksaw  
• Propane Torch  
• Soft Solder  
• Solder Flux  
• Emery Cloth  
• Pipe Wrenches (2) 14” (356 mm)  
• Screwdriver  
• Tin Snips  
• 6’ (1.82 m) Tape or Folding Ruler  
• Garden Hose  
• Wire Brushes  
• Drill  
• Pipe Dope or Teflon Tape  
DRILL  
PROPANE  
TORCH  
SLOT-HEAD SCREWDRIVER  
TUBING CUTTER  
TIN SNIPS  
PHILLIPS SCREWDRIVER  
ROLL OF  
EMERY CLOTH  
PIPE DOPE  
(SQUEEZE TUBE)  
HACKSAW  
ROLL OF TEFLON  
TAPE (USE ONLYON  
USE FOR WATER AND GAS  
WATER HEATER  
CONNECTIONS  
CONNECTIONS)  
3/4” (19 mm) WIRE BRUSH  
1/2” (13 mm) WIRE BRUSH  
SOLDER  
FLUX  
ROLL OF LEAD-FREE  
SOFT SOLDER  
6 FOOT TAPE  
GARDEN HOSE  
PIPE WRENCH  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
TYPICAL INSTALLATION  
GET TO KNOW YOUR WATER HEATER - GAS MODELS  
A
B
C
D
E
F
G
H
J
Vent Pipe–Exhaust  
Vent Terminal  
K
L
Hot Water Outlet  
V
W
X
Y
Z
Drip Leg (Sediment Trap)  
Drain Valve  
Gas Valve-Thermostat  
Drain Pan  
Outlet Receptacle (115 VAC)  
Temperature-Pressure Relief Valve  
Flue  
Flue Baffle Assembly**  
Insulation  
Control Harness  
Rating Plate  
Gas Supply  
Manual Gas Shut-off Valve  
Ground Joint Union  
Vent Adapter-Rubber Boot  
Blower Assembly  
Cold Water Inlet  
Inlet Water Shut-off Valve  
Union  
M
N
O
P
Q
R
S
T
Air Intake Screen - Base Pan  
AA Inner Door  
BB Outer Door  
CC HSI Burner Assembly  
DD Air Intake Screen -  
Blower Assembly  
Inlet Dip Tube  
Anode**  
U
EE FV Sensor Assembly  
* ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS.  
** LOCATED UNDER THE BLOWER ASSEMBLY.  
NATURAL HOT SURFACE IGNITER & MAIN BURNER  
HOT  
SURFACE  
IGNITOR  
SENS
PROPANE HOT SURFACE IGNITER & MAIN BURNER  
HOT  
SURFACE  
IGNITOR  
SENSOR  
TEMPERATURE INDICATORS  
*CAUTION: 115 VAC IN CONTROL HARNESS  
AND INSIDE OUTER DOOR  
T
GAS MODELS  
WITH HOT SURFACE IGNITION  
& 2", 3" OR 4" PVC VENT CAPABILITY  
FIGURE1.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
TYPICAL INSTALLATION  
MIXING VALVE USAGE  
FIGURE2.  
HOTTERWATERCANSCALD:  
Water heaters are intended to produce hot water. Water heated to a  
temperature which will satisfy space heating, clothes washing, dish  
washing, and other sanitizing needs can scald and permanently injure  
you upon contact. Some people are more likely to be permanently injured  
by hot water than others. These include the elderly, children, the infirm, or  
physically/mentally handicapped. If anyone using hot water in your home  
fits into one of these groups or if there is a local code or province law  
requiring a certain temperature water at the hot water tap, then you must  
takespecialprecautions. Inadditiontousingthelowestpossibletemperature  
setting that satisfies your hot water needs, a means such as a *Mixing  
Valve, shall be used at the hot water taps used by these people or at the  
water heater. Mixing valves are available at plumbing supply or hardware  
stores. Consult Maytag Customer Service (1-800-788-8899). Follow  
mixing valve manufacturer’s instructions for installation of the valves.  
Before changing the factory setting on the thermostat, read the  
“Temperature Regulation” section in this manual, see Figure 26.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION INSTRUCTIONS  
4. Attach a hose to the water heater drain  
Removing the Old Water Heater  
valve and put the other end in a floor  
drain or outdoors. Open the water  
heater drain valve. Open a nearby hot  
water faucet which will relieve  
pressure in the water heater and speed  
draining. The water passing out of the  
drain valve may be extremely hot. To  
avoid being scalded, make sure all  
connections are tight and that the water  
flow is directed away from any person,  
see Figures 3 and 6.  
FIGURE6.  
5. Disconnect the vent pipe from the blower assembly where it connects  
to the water heater. In most installations the vent pipe can be lifted off  
after any screw or other attached devices are removed. Make sure  
existing vent complies with maximum and minimum vent lengths on  
page 18.  
6. If you have copper piping to the water heater, the two copper water  
pipes can be cut with a hacksaw approximately four inches away  
from where they connect to the water heater, see Figure 7. This will  
avoid cutting off pipes too short. Additional cuts can be made later if  
necessary. Disconnect the temperature-pressure relief valve drain  
line. When the water heater is drained, disconnect the hose from the  
drain valve. Close the drain valve. The water heater is now completely  
disconnected and ready to be removed.  
FIGURE3.  
1. Turn “OFF” the gas supply to the water  
heater.  
If the main gas line Shut-off valve  
serving all gas appliances is used, also  
shut “OFF” the gas at each appliance.  
Leave all gas appliances shut “OFF”  
until the water heater installation is  
completed, see Figures 3 and 4.  
FIGURE7.  
FIGURE4.  
FIGURE5.  
If you have galvanized pipes to the water heater, loosen the two  
galvanized pipes with a pipe wrench at the union in each line. Also  
disconnect the piping remaining to the water heater, see Figure 8.  
These pieces should be saved since they may be needed when  
reconnecting the new water heater. Disconnect the temperature-  
pressure relief valve drain line. When the water heater is drained,  
disconnect the hose from the drain valve. Close the drain valve.  
The water heater is now completely disconnected and ready to be  
removed. Mineral buildup or sediment may have accumulated in the  
old water heater. This causes the water heater to be much heavier  
than normal and this residue, if spilled out, could cause staining.  
2. Turn “OFF” the water supply to the  
water heater at the water shut off  
valve or water meter. Some  
installations require that the water be  
turned off to the entire house, see  
Figures 3 and 5.  
3. Check again to make sure the gas supply is “OFF” to the water  
heater. Then disconnect the gas supply connection from the gas  
control valve.  
FIGURE8.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATIONSINAREASWHEREFLAMMABLELIQUIDS(VAPORS)  
ARELIKELYTOBEPRESENTORSTORED(GARAGES,STORAGEAND  
UTILITYAREAS, ETC.): Flammable liquids (such as gasoline, solvents,  
propane (LP or butane, etc.) and other substances (such as adhesives,  
etc.) emit flammable vapors which can be ignited by a gas water  
heater’s hot surface igniter or main burner. The resulting flashback  
and fire can cause death or serious burns to anyone in the area. This  
water heater is equipped with a FV sensor for detecting the presence  
of flammable vapors, see Figure 9. When the sensor detects those  
vapors, the unit will shut down and not operate. Should this happen,  
please refer to the troubleshooting guide on pages 29-30. Even though  
this water heater is a flammable vapors ignition resistant water heater  
and is designed to reduce the chances of flammable vapors being  
ignited, gasoline and other flammable substances should never be  
stored or used in the same vicinity or area containing a gas water  
heater or other open flame or spark producing appliance.  
FACTS TO CONSIDERABOUT THE LOCATION  
Carefully choose an indoor location for the new water heater, because  
the placement is a very important consideration for the safety of the  
occupantsinthebuildingandforthemosteconomicaluseoftheappliance.  
This water heater is not for use in manufactured (mobile) homes  
or outdoor installation.  
Whether replacing an old water heater or putting the water heater in a  
new location, the following critical points must be observed:  
1. Select a location indoors as close as practical to the vent terminal or  
location to which the water heater vent piping is going to be connected,  
and as centralized with the water piping system as possible.  
2. Selected location must provide adequate clearances for servicing  
and proper operation of the water heater.  
Installation of the water heater must be accomplished in such a manner  
that if the tank or any connections should leak, the flow will not cause  
damage to the structure. For this reason, it is not advisable to install the  
water heater in an attic or upper floor. When such locations cannot be  
avoided, a suitable drain pan should be installed under the water heater.  
Drain pans are available at your local hardware store. Such a drain pan  
must have a minimum length and width of at least 2" (5.1 cm) greater than  
the water heater dimensions and must be piped to an adequate drain.  
The pan must not restrict combustion air flow.  
FIGURE9.  
Also, the water heater must be located and/or protected so it is not  
subject to physical damage by a moving vehicle.  
Water heater life depends upon water quality, water pressure and the  
environment in which the water heater is installed. Water heaters are  
sometimes installed in locations where leakage may result in property  
damage, even with the use of a drain pan piped to a drain. However,  
unanticipated damage can be reduced or prevented by a leak detector or  
water shut-off device used in conjunction with a piped drain pan. These  
devices are available from some plumbing supply wholesalers and  
retailers, and detect and react to leakage in various ways:  
• Sensors mounted in the drain pan that trigger an alarm or turn off the  
incoming water to the water heater when leakage is detected.  
• Sensors mounted in the drain pan that turn off the water supply to the  
entire home when water is detected in the drain pan.  
• Water supply shut-off devices that activate based on the water  
pressure differential between the cold water and hot water pipes  
connected to the water heater.  
• Devices that will turn off the gas supply to a gas water heater while at  
the same time shutting off its water supply.  
This water heater must not be installed directly on carpeting. Carpeting  
must be protected by metal or wood panel beneath the appliance  
extending beyond the full width and depth of the appliance by at least  
3" (7.6 cm) in any direction, or if the appliance is installed in an alcove  
or closet, the entire floor must be covered by the panel. Failure to heed  
this warning may result in a fire hazard.  
Minimum clearances between the water heater and combustible  
construction are 0 inch at the sides and rear, 5" (12.7 cm) from the front  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
and 12" (30.5 cm) from the top. (Standard clearance.) If clearances  
stated on the heater differ from standard clearances, install water heater  
according to clearances stated on the heater.  
flammable in many cases, will also react to form corrosive hydrochloric  
acid when exposed to the combustion products of the water heater.  
The results can be hazardous, and also cause product failure.  
INSULATION BLANKETS  
Adequate clearance for servicing this appliance should be considered  
before installation, such as changing the anodes, etc.  
A minimum clearance of 5" (12.7 cm) must be allowed for access to  
replaceable parts such as the thermostats, drain valve and relief valve.  
When installing the heater, consideration must be given to proper location.  
Location selected should be as close to the wall as practicable and as  
centralized with the water piping system as possible.  
Insulation blankets are available to the general public for external use  
on gas water heaters but are not necessary with Maytag products.  
The purpose of an insulation blanket is to reduce the standby heat loss  
encountered with storage tank heaters. Your Maytag water heater  
meets or exceeds the National Appliance Energy Conservation Act  
standards with respect to insulation and standby loss requirements,  
making an insulation blanket unnecessary.  
FIGURE10.  
Should you choose to apply an insulation blanket to this heater, you  
should follow these instructions (For identification of components  
mentioned below, see Figure 1). Failure to follow these instructions  
can restrict the air flow required for proper combustion, potentially  
resulting in fire, asphyxiation, serious personal injury or death.  
• Do not apply insulation to the top of the water heater, as this will  
interfere with safe operation of the blower assembly.  
• Do not cover the outer door, thermostat or temperature & pressure  
relief valve.  
• Do not allow insulation to come within 2" (5.1 cm) of the floor to  
prevent blockage of combustion air flow to the burner.  
• Do not cover the instruction manual. Keep it on the side of the  
water heater or nearby for future reference.  
• Do obtain new warning and instruction labels from Maytag  
for placement on the blanket directly over the existing labels.  
• Do inspect the insulation blanket frequently to make certain it  
does not sag, thereby obstructing combustion air flow.  
A gas water heater cannot operate properly without the correct amount  
of air for combustion. Do not install in a confined area such as a closet,  
unless you provide air as shown in the “Facts to Consider About the  
Location” section. Never obstruct the flow of ventilation air. If you  
have any doubts or questions at all, call your gas supplier. Failure to  
provide the proper amount of combustion air can result in a fire or  
explosion and cause death, serious bodily injury, or property damage.  
COMBUSTIONAIRAND VENTILATION FOR  
APPLIANCES LOCATED IN UNCONFINED SPACES  
UNCONFINED SPACE is space whose volume is not less than  
50 cubic feet per 1,000 Btu per hour (4.8 cubic meters per kW) of the  
aggregate input rating of all appliances installed in that space. Rooms  
communicating directly with the space in which the appliances are  
installed, through openings not furnished with doors, are considered a  
part of the unconfined space.  
In unconfined spaces in buildings, infiltration may be adequate to provide  
air for combustion, ventilation and dilution of flue gases. However, in  
buildings of tight construction (for example, weather stripping, heavily  
insulated, caulked, vapor barrier, etc.), additional air may need to be  
provided using the methods described in “CombustionAir and Ventilation  
forAppliances Located in Confined Spaces.”  
FIGURE11.  
COMBUSTIONAIRAND VENTILATION FOR  
APPLIANCES LOCATED IN CONFINED SPACES  
If this water heater will be used in beauty shops, barber shops, cleaning  
establishments, or self-service laundries with dry cleaning equipment,  
it is imperative that the water heater or water heaters be installed so  
that combustion and ventilation air be taken from outside these areas.  
CONFINED SPACE is a space whose volume is less than 50 cubic feet  
per 1,000 Btu per hour (4.8 cubic meters per kW) of the aggregate  
input rating of all appliances installed in that space.  
Propellants of aerosol sprays and volatile compounds, (cleaners,  
chlorine based chemicals, refrigerants, etc.) in addition to being highly  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chemical vapor corrosion of the flue, blower assembly and vent system  
may occur if air for combustion contains certain chemical vapors.  
Spray can propellants, cleaning solvents, refrigerator and air conditioner  
refrigerants, swimming pool chemicals, calcium and sodium chloride,  
waxes, bleach and process chemicals are typical compounds which  
are potentially corrosive.  
2. When communicating with the outdoors through vertical ducts, each  
opening shall have a minimum free area of 1 square inch per 4,000  
Btu per hour (5.5 cm2/kW) of total input rating of all equipment in the  
enclosure, see Figure 14.  
3. When communicating with the outdoors through horizontal ducts,  
each opening shall have a minimum free area of 1 square inch per  
2,000 Btu per hour (11 cm2/kW)) of total input rating of all equipment  
in the enclosure, see Figure 15.  
A. ALLAIR FROM INSIDE BUILDINGS: (See Figure 11 and 12)  
The confined space shall be provided with two permanent openings  
communicating directly with an additional room(s) of sufficient volume  
so that the combined volume of all spaces meets the criteria for an  
unconfined space. The total input of all gas utilization equipment installed  
in the combined space shall be considered in making this determination.  
Each opening shall have a minimum free area of one square inch per  
1,000 Btu per hour (22 cm2/kW) of the total input rating of all gas utilization  
equipment in the confined space, but not less than 100 square inches  
(645 cm2). One opening shall commence within 12 inches  
(31 cm) of the top and one commencing within 12 inches (31 cm) of the  
bottom of the enclosures.  
FIGURE14.  
4. When ducts are used, they shall be of the same cross-sectional  
area as the free area of the openings to which they connect. The  
minimum short side dimension of rectangular air ducts shall not be  
less than 3 inches (7.6 cm), see Figure 15.  
FIGURE12.  
B. ALL AIR FROM OUTDOORS: (See Figures 13, 14 and 15)  
The confined space shall be provided with two permanent openings,  
one commencing within 12 inches (31 cm) of the top and one  
commencing within 12 inches (31 cm) from the bottom of the enclosure.  
The openings shall communicate directly, or by ducts, with the outdoors  
or spaces (crawl or attic) that freely communicate with the outdoors.  
1. When directly communicating with the outdoors, each opening shall  
have a minimum free area of 1 square inch per 4,000 Btu per hour  
(5.5 cm2/kW) of total input rating of all equipment in the enclosure,  
see Figure 13.  
FIGURE15.  
5. Louvers and Grilles: In calculating free area, consideration shall be  
given to the blocking effect of louvers, grilles or screens protecting  
openings. Screens used shall not be smaller than 1/4 inch  
(6.4 mm) mesh. If the free area through a design of louver or grille  
is known, it should be used in calculating the size opening required  
to provide the free area specified. If the design and free area is not  
known, it may be assumed that wood louvers will be 20-25 percent  
free area and metal louvers and grilles will have 60-75 percent free  
area. Louvers and grilles shall be fixed in the open position or  
interlocked with the equipment so that they are opened automatically  
during equipment operation.  
6. Special Conditions Created by Mechanical Exhausting or Fireplaces:  
operation of exhaust fans, ventilation systems, clothes dryers or  
fireplaces may create conditions requiring special attention to avoid  
unsatisfactory operation of installed gas utilization equipment.  
FIGURE13.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The water within the water heater tank expands as it is heated and  
increases the pressure of the water system. If the relieving point of the  
water heater’s temperature-pressure relief valve is reached, the valve  
will relieve the excess pressure. The temperature-pressure relief  
valve is not intended for the constant relief of thermal  
expansion. This is an unacceptable condition and must be corrected.  
WATER PIPING  
It is recommended that any devices installed which could create a closed  
system have a by-pass and/or the system have an expansion tank to  
relieve the pressure built by thermal expansion in the water system.  
Consult Maytag Customer Service at 1-800-788-8899 for an  
authorized installer on how to control this situation.  
NOTE: To protect against untimely corrosion of hot and cold  
water fittings, it is strongly recommended that di-electric unions  
or couplings be installed on this water heater when connected  
to copper pipe.  
HOTTER WATER CAN SCALD:  
Water heaters are intended to produce hot water. Water heated to a  
temperature which will satisfy space heating, clothes washing, dish  
washing, cleaning and other sanitizing needs can scald and permanently  
injure you upon contact. Some people are more likely to be permanently  
injured by hot water than others. These include the elderly, children, the  
infirm, or physically/mentally handicapped. If anyone using hot water in  
your home fits into one of these groups or if there is a local code or  
province law requiring a certain temperature water at the hot water tap,  
then you must take special precautions. In addition to using the lowest  
possible temperature setting that satisfies your hot water needs, a  
means such as a *mixing valve, shall be used at the hot water taps used  
by these people or at the water heater, see Figure 2. Valves for reducing  
point of use temperature by mixing cold and hot water are also available:  
Consult Maytag Customer Service (1-800-788-8899). Follow  
manufacturer’s instructions for installation of the valves. Before changing  
the factory setting on the thermostat, read the “Temperature Regulation”  
section in this manual.  
This water heater shall not be connected to any heating system or  
component or used as a non-potable water heating appliance.  
All piping components connected to this unit shall be suitable for use  
with potable water.  
Toxic chemicals, such as those used for boiler treatment shall not be  
introduced into this system.  
When the system requires water at temperatures higher than required  
for domestic water purposes, a tempering valve must be installed. Please  
refer to Figure 2 for suggested piping arrangement.  
Water supply systems may, because of such events as high line  
pressure, frequent cut-offs, the effects of water hammer among others,  
have installed devices such as pressure reducing valves, check valves,  
back flow preventers, etc. to control these types of problems. When  
these devices are not equipped with an internal by-pass, and no other  
measures are taken, the devices cause the water system to be closed.  
As water is heated, it expands (thermal expansion) and closed systems  
do not allow for the expansion of heated water.  
FIGURE16.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 16 shows the typical attachment of the water piping to the water  
heater. The water heater is equipped with 3/4 inch NPT water  
connections.  
The valve must be marked with a maximum set pressure not to exceed  
the marked hydrostatic working pressure of the water heater  
(150 psi = 1,035 kPa) and a discharge capacity not less than the water  
heater input rate as shown on the model rating plate.  
NOTE: If using copper tubing, solder tubing to an adapter before  
attaching the adapter to the cold water inlet connection. Do not  
solder the cold water supply line directly to the cold water inlet.  
It will harm the dip tube and damage the tank.  
For safe operation of the water heater, the relief valve must not be  
removed from its designated opening nor plugged.  
The temperature-pressure relief valve must be installed directly into the  
fitting of the water heater designed for the relief valve. Position the  
valve downward and provide tubing so that any discharge will exit only  
within 6 inches (15.2 cm) above, or at any distance below the structural  
floor. Be certain that no contact is made with any live electrical part. The  
discharge opening must not be blocked or reduced in size under any  
circumstances. Excessive length, over 30 feet (9.14 m), or use of more  
than four elbows can cause restriction and reduce the discharge  
capacity of the valve, see Figures 16 or 20.  
T & P Valve and Pipe Insulation (if supplied)  
Remove insulation for T & P valve and pipe connections from carton.  
No valve or other obstruction is to be placed between the relief valve  
and the tank. Do not connect tubing directly to discharge drain unless a  
6" (15.2 cm) air gap is provided. To prevent bodily injury, hazard to life,  
or property damage, the relief valve must be allowed to discharge water  
in quantities should circumstances demand. If the discharge pipe is not  
connected to a drain or other suitable means, the water flow may cause  
property damage.  
FIGURE17.  
Fit pipe insulation over the incoming cold water line and the hot water  
line. Make sure that the insulation is against the top cover of the heater.  
Fit T & P valve insulation over valve. Make sure that the insulation does  
not interfere with the lever of the T & P valve.  
Secure all insulation using tape.  
TEMPERATURE-PRESSURE RELIEF VALVE  
The Discharge Pipe:  
Shall not be smaller in size than the outlet pipe size of the valve, or  
have any reducing couplings or other restrictions.  
• Shall not be plugged or blocked.  
Shall be of material listed for hot water distribution.  
Shall be installed so as to allow complete drainage of both the  
temperature-pressure relief valve, and the discharge pipe.  
• Shall terminate at an adequate drain.  
Shall not have any valve between the relief valve and tank.  
This heater is provided with a properly certified combination  
temperature - pressure relief valve by the manufacturer.  
The valve is certified by a nationally recognized testing laboratory that  
maintains periodic inspection of production of listed equipment of  
materials as meeting the requirements for Relief Valves andAutomatic  
Gas Shut-off Devices for Hot Water Supply Systems, ANSI Z21.22 • CSA  
4.4, and the code requirements ofASME.  
The temperature-pressure relief valve must be manually operated at least  
once a year. Caution should be taken to ensure that (1) no one is in front  
of or around the outlet of the temperature-pressure relief valve discharge  
line, and (2) the water manually discharged will not cause any bodily  
injury or property damage because the water may be extremely hot.  
If after manually operating the valve, it fails to completely reset and  
continues to release water, immediately close the cold water inlet to the  
water heater, follow the draining instructions, and replace the  
temperature-pressure relief valve with a new one.  
If replaced, the valve must meet the requirements of local codes, but not  
less than a combination temperature and pressure relief valve certified  
as indicated in the above paragraph.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
When installed at elevations above 7,700 feet (2,347 m), input rating  
should be reduced at the rate of 4 percent for each 1,000 feet (305 m)  
above sea level which requires replacement of the burner orifice in  
accordance with Natural Gas and Propane Installation Code CAN/CSA  
B149.1. Contact your local gas supplier for further information.  
GAS PIPING  
Failure to replace the standard orifice with a high altitude orifice when  
installed at elevations above 7,700 feet (2,347 m) could result in  
improper and inefficient operation of the appliance, producing carbon  
monoxide gas in excess of safe limits. This could result in serious  
injury or death. Contact your gas supplier for any specific changes  
which may be required in your area.  
Make sure the gas supplied is the same type listed on the model rating  
plate. The inlet gas pressure must not exceed 14 inch water column (3.5  
kPa) for natural and propane gas (L.P.). The minimum inlet gas pressure  
shown on the rating plate is that which will permit firing at rated input.  
All gas piping must comply with local codes and ordinances or with the  
Natural Gas and Propane Installation Code CAN/CSA B149.1 whichever  
applies. Copper and brass tubing and fittings (except tin lined copper  
tubing) shall not be used.  
Use pipe joint compound or teflon tape marked as being resistant to the  
action of petroleum [Propane (L.P.)] gases.  
If the gas control valve is subjected to pressures exceeding 1/2 psi  
(3.5 kPa), the damage to the gas control valve could result in a fire or  
explosion from leaking gas.  
The appliance and its gas connection must be leak tested before placing  
the appliance in operation.  
If the main gas line Shut-off serving all gas appliances is used, also  
turn “off” the gas at each appliance. Leave all gas appliances shut  
“off” until the water heater installation is complete.  
The appliance and its individual Shut-off valve shall be disconnected  
from the gas supply piping system during any pressure testing of that  
system at test pressures in excess of 1/2 pound per square inch  
(3.5 kPa). It shall be isolated from the gas supply piping system by  
closing its individual manual Shut-off valve during any pressure testing  
of the gas supply piping system at test pressures equal to or less than  
1/2 pound per square inch (3.5 kPa).  
A gas line of sufficient size must be run to the water heater. Consult  
the current edition of Natural Gas and Propane Installation Code  
CAN/CSA B149.1 and your gas supplier concerning pipe size.  
There must be:  
• A readily accessible manual shut off valve in the gas supply line  
serving the water heater, and  
• A drip leg (sediment trap) ahead of the gas control valve to help  
prevent dirt and foreign materials from entering the gas control valve.  
• A flexible gas connector or a ground joint union between the shut off  
valve and control valve to permit servicing of the unit.  
Connectingthegaspipingtothegascontrolvalveofthewaterheatercanbe  
accomplished by either of the two methods shown in Figures 18 and 19.  
Be sure to check all the gas piping for leaks before lighting the water  
heater. Use a soapy water solution, not a match or open flame. Rinse  
off soapy solution and wipe dry.  
FIGURE 18. GAS PIPING WITH  
FLEXIBLECONNECTOR.  
FIGURE 19. GAS PIPING WITH ALL  
BLACK IRON PIPE TO GAS CONTROL.  
Water heaters covered in this manual have been tested and approved  
for installation at elevations up to 7,700 feet (2,347 m) above sea level.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Never use this water heater unless it is completely full of water. To  
prevent damage to the tank, the tank must be filled with water. Water  
must flow from the hot water faucet before turning “ON” gas to the  
water heater.  
SEDIMENT TRAPS  
To fill the water heater with water:  
1. Close the water heater drain valve by turning the handle to the right  
(clockwise). The drain valve is on the lower front of the water  
heater.  
2. Open the cold water supply valve to the water heater.  
NOTE: The cold water supply valve must be left open when  
the water heater is in use.  
3. To insure complete filling of the tank, allow air to exit by opening the  
nearest hot water faucet. Allow water to run until a constant flow  
is obtained. This will let air out of the water heater and the piping.  
4. Check all water piping and connections for leaks. Repair as needed.  
BLOWERASSEMBLYINSTALLATION  
SEQUENCEOFINSTALLATION  
Contaminants in the gas lines may cause improper operation of the gas  
control valve that may result in fire or explosion. Before attaching the  
gas line be sure that all gas pipe is clean on the inside. To trap any dirt  
or foreign material in the gas supply line, a drip leg (sometimes called a  
sediment trap) must be incorporated in the piping. The drip leg must be  
readily accessible. Install in accordance with the “Gas Piping” section.  
Refer to the current edition of the Natural Gas and Propane Installation  
Code CAN/CSA B149.1.  
1. Thispowerventedwaterheatercomeswiththeblowerassemblyinstalled.  
2
After the unit is set in place, make sure the blower assembly is still  
mounted securely and the air intake screen of the blower assembly  
is installed in the dilution air opening. Also make sure the drain port  
of the rubber boot vent adapter is capped off. Lastly, make sure  
there is no damage to the blower.  
3. Make sure there is no packing material in the discharge of the  
blower or the intake of the dilution air restrictor, see Figure 21.  
4. Make sure that the plastic tubing is still attached from the air pressure  
switch to the port on the blower housing. Make sure the plastic  
tubing is not folded anywhere between the pressure switch and  
the blower housing.  
5. Make sure the ON/OFF switch is in the OFF position and that the  
outer harness is connected from the blower control box to the  
connector on the bottom side of the gas valve.  
A sediment trap shall be installed as close to the inlet of the water  
heater as practical at the time of water heater installation. The sediment  
trap shall be either a tee fitting with a capped nipple in the bottom outlet  
or other device recognized as an effective sediment trap. If a tee fitting  
is used, it shall be installed in conformance with one of the methods of  
installation shown in Figures 18 and 19 on page 15.  
6. If the outer harness is not factory installed, make sure the ON/  
OFF switch is in the OFF position and then connect the harness  
from the blower control box to the connector on the bottom side  
of the gas valve.  
7. Do not plug in power cord until vent system is completely installed.  
This power vent heater operates on 110-120 Vac, therefore a  
grounded outlet must be within reach of the six (6) foot (1.8 m)  
flexible power cord supplied with the unit (see Figure 1). The power  
cord supplied may be used only where local codes permit. If local  
codes do not permit the use of a flexible power supply cord:  
FIGURE20.  
a.) Make sure the unit is unplugged from wall outlet. Remove screws  
and open panel on front of control box.  
FILLING THE WATER HEATER  
b.) Cut the flexible power cord, leaving enough to be able to make  
connections and remove the strain relief fitting from box.  
c.) Install suitable conduit fitting in side of enclosure and then follow  
(d.) and (e.) below.  
d.) Splice field wiring into existing wiring using code authorized method  
(wire nuts, etc.).  
e.) Be certain that neutral and live connections are not reversed when  
making these connections.  
f.) Close panel on the side of control box, make sure that access panel  
is secured shut.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VENTINGAND INSTALLATION  
VENT CONNECTIONS TO BLOWERASSEMBLY  
Figure 15 shows the optimal placement of the 2" to 3" or 3" to 4" reducer;  
however, the vent can be reduced at any point in the vent system as long  
as the maximum vent length is not exceeded.  
Plan the layout of the vent system from the vent termination to the  
water heater considering all of the 90° and 45° elbows plus the  
number of feet of pipe that would be needed to install the total vent  
system. The water heater must be vented to the outdoors as  
described in these instructions. DO NOT connect this water heater  
to an existing vent or chimney. It must be vented separately from  
all other appliances. Nonmetallic vent may be used if it has “Heat  
Deflection Temperature” (HDT@66 psi) or 455 kPa of at least 157°F  
or 69°C. Typical nonmetallic vent materials meeting this requirement  
are: PVC (Schedule 40, ASTM D-1785), Coex Cellular Core  
(Schedule 40, ASTM F-441), CPVC (Schedule 40, ASTM D-2846),  
ABS (Schedule 40, ASTM D-2661). The fittings, other than the  
supplied Vent Termination should be equivalent to the following:  
PVC (Schedule 40, DWV,ASTM D-2665), CPVC (Schedule 40, DWV,  
ASTM F-438), ABS (Schedule 40 DWV, ASTM D-2661).  
The cement used should be as recommended by the vent pipe  
manufacturer. See the instructions on pages 21 and 22 for the proper  
method of cutting and cementing the PVC pipe and fittings.  
FIGURE21.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The unit may be vented horizontally through a wall or vertically through  
the roof. Pipe runs must be adequately supported along both vertical  
and horizontal runs as follows:  
CONDENSATION  
Condensate formation does not occur in all installations of power vented  
water heaters, but should be protected against on installations where  
it can form in the venting system. Condensation in the venting system  
of power vented water heaters is dependent upon installation conditions  
including, but not limited to ambient temperature and humidity of  
installation location, ambient temperature and humidity of venting space,  
vent discharge and slope, and product usage. In certain conditions,  
installations in unconditioned space or having long horizontal or vertical  
vent runs may accumulate condensate. In these conditions, the vent  
pipe should be sloped downward away from the blower assembly  
1/4" (6.4 mm) per five feet (1.5 m) of pipe but not more than 1 1/2"  
(3.8 cm) in the total vent length. If the vent piping is vented level or  
sloped upwards away from the blower assembly, then adequate means  
for draining and disposing of the condensate needs to be made by the  
installer (if condensate is detected). If you have condensate, then a  
3/8" drain hose can be connected to the built-in drain port of the rubber  
boot on the blower assembly. For your convenience, the rubber boot  
is supplied with a removable cap on the built-in drain port. Prior to  
operating the water heater, make sure the removable cap is installed  
on the drain port (if a drain hose is not needed).  
• For Schedule 40, 2" PVC,ABS, Coex Cellular Core vent pipe: Every  
3 feet (0.9 m).  
• For Schedule 40, 3" PVC,ABS, Coex Cellular Core vent pipe: Every  
3.5 feet (1.1 m).  
• For Schedule 40, 4" PVC,ABS, Coex Cellular Core vent pipe: Every  
4 feet (1.2 m).  
• For Schedule 40, 2" CPVC vent pipe: Every 5 feet (1.5 m).  
• For Schedule 40, 3" CPVC vent pipe: Every 6 feet (1.8 m).  
• For Schedule 40, 4" CPVC vent pipe: Every 6.5 feet (2.0 m).  
It is imperative that the first hanger (or support) be located on the  
horizontal run immediately adjacent to the first 90-degree elbow from  
the vertical rise. Support method used should isolate the vent pipe  
from the floor joists or other structural members to prevent the  
transmission of noise and vibration. Do not support, pin, or otherwise  
secure the venting system in a way that restricts the normal thermal  
expansion and contraction of the chosen venting material.  
MAXIMUM VENT LENGTHS  
40,000 BTU Units:  
For 2" Venting, the maximum equivalent feet of pipe allowed  
is 40 feet (12.2 m). This does not include the supplied vent termination  
for the water heater. For the 2" venting, one 90° elbow is approximately  
equal to 5 feet (1.5 m). One 45° elbow is approximately equal to 2.5  
feet (0.8 m). It is recommended that at least 2 feet (0.6 m) of spacing  
be used in between all 45° elbows and all 90°elbows.  
If the water heater is being installed as a replacement for an existing  
power vented heater in pre-existing venting, a thorough inspection of  
the existing venting system must be performed prior to any installation  
work. Verify that the correct material as detailed above has been used,  
and that the minimum or maximum vent lengths and terminal location as  
detailed in this manual have been met. Carefully inspect the entire  
venting system for any signs of cracks or fractures, particularly at the  
joints between elbows and other fittings and the straight runs of vent  
pipe. Check the system for signs of sagging or other stresses in the  
joints as a result of misalignment of any components in the system. If  
any of these conditions are found, they must be corrected in accordance  
with the venting instructions in this manual before completing the  
installation and putting the water heater into service.  
For 3" Venting, the maximum equivalent feet of pipe allowed  
is 120 feet (36.6 m). This does not include the VentTermination (supplied  
locally) for the water heater. For the 3" venting, one 90° elbow is  
approximately equal to 5 feet (1.5 m). One 45° elbow is approximately  
equal to 2.5 feet (0.8 m). It is recommended that at least 2 feet (0.6 m)  
of spacing be used in between all 45° elbows and all 90°elbows.  
For 4" Venting, the maximum equivalent feet of pipe allowed  
is 160 feet (48.8 m). This does not include the VentTermination (supplied  
locally) for the water heater. For the 4" venting, one 90° elbow is  
approximately equal to 8 feet (2.4 m). One 45° elbow is approximately  
equal to 4 feet (1.2 m). It is recommended that at least 2 feet (0.6 m) of  
spacing be used in between all 45° elbows and all 90°elbows.  
Except where instructed in this manual, the mixing of 2", 3" and 4" vent pipe  
is NOTALLOWED. If 2" pipe is to be used, then a 2" to 3" bell reducer is  
recommended. Figure 21 shows the recommended location for the bell  
reducer. If the bell reducer is located at the rubber boot on the blower  
assembly, then a short section of 3" vent pipe needs to be installed in the  
rubberbootforproperconnectionofthe2"to3"bellreducer. Thatlengthcan  
betheminimumlengthrequiredfortheconnection.  
50,000 BTU Units:  
If 4" pipe is to be used, then a 3" to 4" bell reducer is recommended.  
Figure 21 shows the recommended location for the bell reducer. If the  
bell reducer is located at the rubber boot on the blower assembly, then  
a short section of 3" vent pipe needs to be installed in the rubber boot  
for proper connection of the 3" to 4" bell reducer. That length can be  
the minimum length required for the connection.  
For 2" Venting, the maximum equivalent feet of pipe allowed  
is 40 feet (12.2 m). This does not include the supplied VentTermination  
for the water heater. For the 2" venting, one 90° elbow is approximately  
equal to 5 feet (1.5 m). One 45° elbow is approximately equal to 2.5  
feet (0.8 m). It is recommended that at least 2 feet (0.6 m) of spacing  
be used in between all 45° elbows and all 90°elbows.  
The water heaters covered by this manual are supplied with a 2" Schedule  
40 PVC 22.5° Vent Terminal. If you decide to vent with 3" or 4" pipe, a  
Schedule40DWV45°VentTerminalmustbeused. Foryourconvenience,  
we have included a screen for both 3" and 4" VentTerminals.  
For 3" Venting, the maximum equivalent feet of pipe allowed  
is 120 feet (36.6 m). This does not include the VentTermination (supplied  
locally) for the water heater. For the 3" venting, one 90° elbow is  
approximately equal to 5 feet (1.5 m). One 45° elbow is approximately  
equal to 2.5 feet (0.8 m). It is recommended that at least 2 feet (0.6 m)  
of spacing be used in between all 45° elbows and all 90°elbows.  
The vent piping should be connected to the blower with a rubber  
adapter and secured with hose clamps. The adapter and clamps are  
provided with the heater.  
For 4" Venting, the maximum equivalent feet of pipe allowed  
is 160 feet (48.8 m). This does not include the VentTermination (supplied  
locally) for the water heater. For the 4" venting, one 90° elbow is  
approximately equal to 8 feet (2.4 m). One 45° elbow is approximately  
equal to 4 feet (1.2 m). It is recommended that at least 2 feet (0.6 m) of  
spacing be used in between all 45° elbows and all 90°elbows.  
Even though the flue gas temperature leaving the blower is between 140°F  
(69°C)and175°F(79°C), someinstallationswillhavewatervaporcondense  
intheventpiping.Ifthisoccurs,thenadequatemeansofdraininganddisposing  
of the condensate needs to be made by the installer.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Vent pipes serving power vented appliances are classified by building  
codes as “vent connectors”. Required clearances from combustible  
materials must be provided in accordance with information in this manual  
under FACTS TO CONSIDER ABOUT THE LOCATION and VENT  
TERMINAL INSTALLATIONS, and with the Natural Gas and Propane  
Installation Code CAN/CSA B149.1 and local codes.  
VENTING  
VENT TERMINAL INSTALLATION  
1. After the point of termination has been determined, use the cover  
plate as a template to mark the hole for the vent pipe to insert  
through the wall. BEWARE OF CONCEALED WIRINGAND PIPING  
INSIDE OFWALL.  
2. If the Vent Terminal is being installed on the outside of a finished  
wall, it may be easier to mark both the inside and outside wall.  
Align the holes by drilling a hole through the center of the template  
from the inside through to the outside. The template can now be  
positioned on the outside wall using the drilled hole as a centering  
point for the template.  
3. A) MASONRY SIDE WALLS  
Chisel an opening approximately one half inch larger than the  
marked circle.  
B) WOODENSIDEWALLS  
Drill a pilot hole approximately one quarter inch outside of the  
marked circle. This pilot hole is used as a starting point for a  
saws-all or sabre saw blade. Cut around the marked circle staying  
approximately one quarter inch outside of the line. (This will allow  
the vent pipe to easily slide through the opening. The resulting  
gap will be covered up by the vent terminal cover plates.) Repeat  
this step on inside wall if necessary.  
4. When the vent piping cannot pass through an outside wall at a  
height greater than or equal to 12" above the ground (or above  
snow accumulation level), then the installation can be modified as  
shown below.  
The vent system must terminate so that proper clearances are  
maintained as cited in local codes or the current edition of the Natural  
Gas and Propane Installation Code CAN/CSA B149.1 as follows:  
1. The exit terminals of a mechanical vent system shall be not less  
than 7 feet (2.13 m) above grade when located adjacent to public  
walkways, see Figure 23.  
2. A venting system shall terminate at least 3 feet (91 cm) above any  
forced air inlet, see Figure 23.  
3. The venting system shall terminate at least 4 feet (1.2 m) below, 4  
feet (1.2 m) horizontally from or, 12 inches (30 cm) above any door,  
window or gravity air inlet into any building.  
Themanufactureralsorecommendsthattheventterminationshouldnot  
be installed closer than 3 feet (91 cm) from an inside corner of an L  
shaped structure and not be less than 12 inches (30 cm) above grade.  
Theventshallterminateaminimumof12inches(30cm)aboveexpected  
snowfall level to prevent blockage of vent termination, see Figure 23.  
4. Incoldclimates, itisrecommendedthatventterminationnotbemounted  
directlyaboveorwithin3feet(91cm)horizontallyfromanoiltankventor  
gasmetertoavoidpotentialfreeze-upfromcondensation, seeFigure23.  
Plan the vent system layout so that proper clearances are maintained  
from plumbing and wiring.  
FIGURE22.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIGURE23.  
This unit can vent through 2", 3" or 4" nonmetallic pipe and fittings.  
VERTICAL VENT RESTRICTIONS  
The vent pipe installation can be started from either the blower discharge  
or the termination wall. Keep in mind the total vent system (pipe and  
elbows) when installing the vent system, see VENTING AND  
INSTALLATIONAND MAXIMUM VENTLENGTHS, pages 17 - 18.  
1. Minimum of twelve 12" (30.5 cm) above the roof or twelve 12"  
(30.5 cm) above the anticipated snow level. Provide proper support  
for all pipe protruding through the roof.  
FIGURE24.  
The vent terminal should be kept as close as possible to the outside  
wall, but you need to allow at least 1.5" (3.8 cm) of pipe past the wall,  
for the wall flange and vent terminal to mount on the pipe.  
Before the vent terminal is installed, caulk (not supplied) around the pipe  
on the exterior wall and install the optional wall flange. The flange can be  
held to the outside wall by placing some of the caulking on the back of the  
flange. The wall flange is supplied for decorative purposes only and is  
not a requirement for the vent termination (if not needed by the installer).  
VERTICAL VENT THROUGH ROOF  
This unit is approved for venting through the roof with the type vent  
terminal that is included with the unit. A proper flashing or “BOOT”  
should be used to seal the pipe where it exits the roof.  
FIGURE25.  
The total vent system should not exceed that which is specified, see  
VENTINGAND INSTALLATION, pages 17 - 18.  
2. 4' (1.2 m) from or 1' (0.3 m) above any gable, dormer, or other roof  
structure with access to interior of building (i.e.-vent, window etc.).  
All of the pipe should be secured as per the instructions in the instructions  
in the VENTINGAND INSTALLATION, pages 17 - 18.  
3. 3' (0.9 m) above any forced air inlet located within 10' (3.0 m).  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
formamide (DMF) may be included to act as a retarding agent to extend  
curing time. Select the proper cement; Schedule 40 cement should be  
used for Schedule 40 pipe. Never use all-purpose cements, commercial  
glues and adhesives orABS cement to joinPVCorCPVCpipe and fittings.  
VENT PIPE PREPARATION  
1. INITIALPREPARATION  
A. Make sure the solvent cement you are planning to use is  
designed for the specific application you are attempting.  
B. Know the physical and chemical characteristics and limitations  
of the PVC and CPVC piping materials that you are about to use.  
C. Know the reputation of your manufacturer and their products.  
D. Know your own qualifications or those of your contractor.  
The solvent welding technique of joining PVC and CPVC pipe  
is a specialized skill just as any other pipe fitting technique.  
APPLICATORS  
E. Closely supervise the installation and inspect the finished  
job before start-up.  
Select a suitable pure bristle type paint brush. Use a proper width  
brush or roller to apply the primer and cement (see chart below).  
Speedy application of cement is important due to its fast drying  
characteristics. IMPORTANT NOTE:Adauber type applicator should  
only be used on pipe sizes 2" and below. For larger diameter pipe, a  
brush or roller must be used.  
F. Contact the manufacturer, supplier, or competent consulting  
agency if you have any questions about the application or  
installation of PVC and CPVC pipe.  
G. Take the time and effort to do a professional job. Shortcuts  
will only cause you problems and delays in start-up. By far,  
the majority of failures in PVC and CPVC systems are the  
result of shortcuts and/or improper joining techniques.  
RECOMMENDED BRUSH* SIZE FOR PRIMER  
AND CEMENTAPPLICATIONS  
Nominal Pipe  
Size Brush Width  
2. SELECTION OF MATERIALS  
(IPS)  
(INS.)  
2
3
1-1/2  
1-1/2 - 2-1/2  
Cutting Device - Saw or Pipe Cutter  
Deburring Tool, Knife, File, or Beveling Machine (2" and above)  
Brush - Pure Bristle  
*USEONLYNATURALBRISTLE  
Rag - Cotton (Not Synthetic)  
3. MAKING THE JOINT  
Primer and Cleaner  
A. Cutting  
Pipe must be squarely cut to allow for the proper interfacing of the  
pipe end and the fitting socket bottom. This can be accomplished  
with a miter box saw or wheel type cutter. Wheel type cutters are  
not generally recommended for larger diameters since they tend to  
flare the corner of the pipe end. If this type of cutter is used, the  
flare on the end must be completely removed.  
Solvent Cement - PVC for PVC Components and CPVC for CPVC  
Components  
Containers - Metal or Glass to hold Primer and Cement. Select the  
type of PVC or CPVC materials to be used on the basis of their  
application with respect to chemical resistance, pressure rating,  
temperature characteristics, etc.  
NOTE: Power saws should be specifically designed to cut plastic pipe.  
InsertionTool - Helpful for larger diameter pipe and fittings 6 inches  
(15.2 cm) and above.  
PRIMER  
It is recommended that Tetrahydrofuran (THF) be used to prepare the  
surfaces of pipe and fittings for solvent welding. Do not use water,  
rags, gasoline or any other substitutes for cleaning PVC or CPVC  
surfaces.Achemical cleaner such as MEK may be used.  
CEMENT  
The cement should be a bodied cement of approximately 500 to 1600  
centipoise viscosity containing 10-20% (by weight) virgin PVC material  
solvated with tetrahydrofuran (THF). Small quantities of dimethyl  
STEP A  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. Deburring  
Useaknife, plasticpipedeburringtool, orfiletoremoveburrsfromtheend  
ofsmalldiameterpipe. Besuretoremoveallburrsfromaroundtheinside  
as well as the outside of the pipe. Aslight chamfer (bevel) of about 10°-  
15° should be added to the end to permit easier insertion of the pipe into  
theendofthefitting. Failuretochamfertheedgeofthepipemayremove  
cementfromthefittingsocket, causingthejointtoleak.  
STEPE  
F. Joint assembly  
Working quickly, insert the pipe into the fitting socket bottom and  
give the pipe or fitting a 1/4 turn to evenly distribute the cement. Do  
not continue to rotate the pipe after it has hit the bottom of the fitting  
socket. Agood joint will have sufficient cement to make a bead all  
the way around the outside of the fitting hub. The fitting will have a  
tendency to slide back while the cement is still wet so hold the joint  
together for about 15 seconds.  
STEPB  
C. Test dry fit of the joint  
Tapered fitting sockets are designed so that an interfaced fit should  
occur when the pipe is inserted about 1/3 to 2/3 of the way into the  
socket. Occasionally, when pipe fitting dimensions are at the  
tolerance extremes, it will be possible to fully insert dry pipe to the  
bottom of the fitting socket. When this happens, a sufficient quantity  
of cement must be applied to the joint to fill the gap between the pipe  
and fitting. The gap must be filled to obtain a strong, leak-free joint.  
D. Inspection, cleaning, priming  
Visually inspect the inside of the pipe and fitting sockets and remove  
all dirt, grease or moisture with a clean dry rag. If wiping fails to  
clean the surfaces, a chemical cleaner must be used. Check for  
possible damage such as splits or cracks and replace if necessary.  
Depth-of-entry  
STEPF  
Marking the depth of entry is a way to check if the pipe has reached  
the bottom of the fitting socket in Step F. Measure the fitting depth  
and mark this distance on the pipe O.D. You may want to add  
several inches to the distance and make a second mark as the  
primer and cement will most likely destroy your first one.  
G. Cleanup and joint movement  
Remove all excess cement from around the pipe and fitting with a  
dry cotton rag. This must be done while the cement is still soft.  
The joint should not be disturbed immediately after the cementing  
procedure, and sufficient time should be allowed for proper curing  
of the joint. Exact drying time is difficult to predict because it depends  
on variables such as temperature, humidity and cement integrity.  
For more specific information, you should contact your solvent  
cement manufacturer.  
Apply primer to the surface of the pipe and fitting socket with a natural  
bristle brush. This process softens and prepares the PVC or CPVC for  
the solvent cementing step. Move quickly and without hesitation to the  
cementing procedure while the surfaces are still wet with primer.  
E. Application of solvent cement  
• Applythesolventcementevenlyandquicklyaroundtheoutsideofthe  
pipe at a width a little greater than the depth of the fitting socket.  
• Apply a light coat of cement evenly around the inside of the  
fitting socket. Avoid puddling.  
• Apply a second coat of cement to the pipe end.  
STEPG  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
FOR YOUR SAFETY READ BEFORE OPERATING  
WARNING: If you do not follow these instructions exactly, a fire or  
explosion may result causing property damage, personal injury or loss of  
life.  
BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATERANDAIR PURGED FROMALL LINES.  
A. This appliance does not have a pilot. It is equipped with  
an ignition device which automatically lights the burner.  
Do NOT try to light the burner by hand.  
B. BEFORE OPERATING smell all around the appliance area  
for gas. Be sure to smell next to the floor because some  
gas is heavier than air and will settle on the floor.  
WHAT TO DO IF YOU SMELLGAS:  
If you cannot reach your gas supplier, call the fire  
department.  
C. Use only your hand to push in the gas control buttons.  
Never use tools. If the control buttons will not push in,  
don’t try to repair them, call a qualified service technician.  
Force or attempted repair may result in a fire or explosion.  
D. Do not use this appliance if any part has been under  
water. Immediately contact a qualified installer or service  
agency to replace a flooded water heater. Do not attempt  
to repair the unit! It must be replaced!  
Do not try to light any appliance.  
Do not touch any electric switch;  
Do not use any phone in your building.  
Immediately call your gas supplier from a neighbor’s phone.  
Follow the gas supplier’s instructions.  
OPERATING INSTRUCTIONS  
4. This appliance is equipped with a device which  
automatically lights the burner.  
DONOTTRYTOLIGHTTHEBURNERBYHAND.  
5. Wait five (5) minutes  
If you then smell gas,  
to clear out any gas.  
STOP! Follow “B” in the  
safety information above on this label. If you don’t smell  
gas, go to the next step.  
6. Turn on all electrical power to the appliance.  
7. Set thermostat to desired setting by first pressing the  
COOLER  
and HOTTER  
buttons together and  
holding for 1 second. Then press the HOTTER  
button.  
8. If the appliance will not operate, follow the instructions  
“TO TURN OFF GAS TO APPLIANCE” and call your  
technician or gas supplier.  
1.  
STOP! Read the safety information above,  
on this label.  
9. WATERTEMPERATUREADJUSTMENT  
is approximately 120°F.  
2. Set the thermostat to the lowest setting by first pressing  
the COOLER and HOTTER buttons together and  
CAUTION: Hotter water increases the risk  
of scald injury. Consult the instruction  
manual before changing temperature.  
holding for 1 second. Then press the COOLER  
until the WARM indicator light appears.  
button  
3. Set the “ON/OFF” switch on the blower control box to the  
“OFF” position.  
WARNING: TURN OFFALL ELECTRIC  
POWERBEFORESERVICING  
TO TURN OFF GAS TOAPPLIANCE  
1. Set the thermostat to the lowest setting by first pressing the COOLER  
and HOTTER  
buttons together and holding  
for 1 second. Then press the COOLER button until the WARM indicator light appears.  
2. Set the ON/OFF switch on the blower control box to the “OFF” position.  
3. Turn off all electric power to the appliance if service is to be performed.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To avoid any unintentional changes in water temperature settings, the  
control has a tamper resistant feature for changing the temperature  
setting. To change the temperature setting follow these instructions:  
TEMPERATURE REGULATION  
1. “Wake Up” the temperature indicators by holding down both  
“COOLER” and “HOTTER” temperature adjustment buttons at the  
same time for one second, see Figure 26. One or two of the  
temperature indicators will light up. These indicators will only remain  
on for 30 seconds if no further buttons are pressed.After 30 seconds  
the control will go back to “Sleep” mode.  
2. Release both of the temperature adjustment buttons.  
a. To decrease the temperature press and release the “COOLER”  
button until the desired setting is reached.  
b. To increase the temperature press and release the “HOTTER”  
button until the desired setting is reached.  
HOT WATER CAN SCALD: Water heaters are intended to produce hot  
water. Water heated to a temperature that will satisfy space heating,  
clothes washing, dish washing, and other sanitizing needs can scald  
and permanently injure you upon contact. Some people are more likely  
to be permanently injured by hot water than others. These include the  
elderly, children, the infirm, or physically/mentally handicapped. If anyone  
using hot water in your home fits into one of these groups or if there is  
a local code or province law requiring a specific hot water temperature  
at the tap, then you must take special precautions. Never allow small  
children to use a hot water tap, or to draw their own bath water. Never  
leave a child or handicapped person unattended in a bathtub or shower.  
NOTE: Holding down the button will not continue to lower or raise the  
temperature setting. The button must be pressed and released for  
each temperature change desired.  
Should overheating occur or the gas supply fail to shut off, turn off the  
manual gas control valve to the appliance.  
It is recommended that lower water temperatures be used to avoid the  
risk of scalding. It is further recommended, in all cases, that the water  
temperature be set for the lowest temperature that satisfies your hot  
water needs. This will also provide the most energy efficient operation  
of the water heater.  
Figure 26 shows the approximate water temperatures produced at  
various thermostat settings. Short repeated heating cycles caused by  
small hot water uses can cause temperatures at the point of use to  
exceed the thermostat setting by up to 30°F (17°C). If you experience  
this type of use you should consider using lower temperature settings  
to reduce scald hazards.  
Valves for reducing the point-of-use temperature by mixing cold and  
hot water are available. See Figure 2. Also available are inexpensive  
devices that attach to faucets to limit hot water temperatures. Contact  
a licensed plumber or the local plumbing authority.  
Time to Produce  
The water heater should be located in an area where the general  
public does not have access.  
Display  
A B C  
2nd and 3rd Degree  
Burns on Adult Skin  
About 1/2 seconds  
About 1-1/2 seconds  
Less than 5 seconds  
About 30 seconds  
More than 5 minutes  
- - - - - - - - - - - - -  
Temperature Setting  
C-Flashing = approx. 160°F (71°C)  
C = approx. 150°F (66°C)  
B = approx. 140°F (60°C)  
A = approx. 130°F (54°C)  
= approx. 120°F (49°C)  
The water temperature setting was factory set at the lowest  
temperature; Pressing the “COOLER”  
button decreases temperature  
and pressing the “HOTTER” button increases the temperature.  
WARM = approx. 80°F (27°C)  
Setting the water heater temperature at 120°F (49°C) (Approx. “  
mark on temperature setting of gas valve) will reduce the risk of scalds.  
Some provinces require settings at specific lower temperatures.  
FIGURE26.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FOR YOUR INFORMATION  
STRANGESOUNDS  
START UP CONDITIONS  
Possible noises due to expansion and contraction of some metal parts  
during periods of heat-up and cool-down do not necessarily represent  
harmful or dangerous conditions.  
CONDENSATE  
Whenever the water heater is filled with cold water, some condensate  
will form while the burner is on.Awater heater may appear to be leaking  
when in fact the water is condensate. This usually happens when:  
Condensation causes sizzling and popping within the burner area during  
heating and cooling periods and should be considered normal. See  
“Condensate” in this section.  
a. A new water heater is filled with cold water for the first time.  
b. Burning gas produces water vapor in water heaters, particularly  
high efficiency models where flue temperatures are lower.  
c. Large amounts of hot water are used in a short time and the refill  
water in the tank is very cold.  
OPERATIONAL CONDITIONS  
SMELLYWATER  
In each water heater there is installed at least one anode rod (see  
parts section) for corrosion protection of the tank. Certain water  
conditions will cause a reaction between this rod and the water. The  
most common complaint associated with the anode rod is one of a  
“rotten egg smell” in the hot water. The smell is a result of four factors  
which must all be present for the odor to develop:  
Moisture from the products of combustion condense on the cooler tank  
surfaces and form drops of water which may fall onto the burner or  
other hot surfaces to produce a “sizzling” or “frying” noise.  
Because of the suddenness and amount of water, condensate water  
may be diagnosed as a “tank leak”.After the water in the tank warms  
up (about 1-2 hours), the condition should disappear.  
a. A concentration of sulfate in the supply water.  
b. Little or no dissolved oxygen in the water.  
Do not assume the water heater is leaking until there has been enough  
time for the water in the tank to warm up.  
c. A sulfate reducing bacteria which has accumulated within the water  
heater (this harmless bacteria is nontoxic to humans).  
d. An excess of active hydrogen in the tank. This is caused by the  
corrosion protective action of the anode.  
An undersized water heater will cause more condensation. The water  
heater must be sized properly to meet the family’s demands for hot  
water including dishwashers, washing machines and shower heads.  
Smelly water may be eliminated or reduced in some water heater  
models by replacing the anode(s) with one of less active material, and  
then chlorinating the water heater tank and all water lines. Contact  
Maytag Customer Service (1-800-788-8899) for further information  
concerning Anode Replacement Kit #9001453 and this chlorination  
treatment. Anode replacement and chlorination of the tank are not  
covered by the water heater’s limited warranty.  
Excessive condensate may be noticed during the winter and early  
spring months when incoming water temperatures are at their lowest.  
Good venting is essential for a gas fired water heater to operate properly  
as well as to carry away products of combustion and water vapor.  
SMOKE/ODOR  
If the smelly water persists after the anode replacement and chlorination  
treatment, we can only suggest that chlorination or aeration of the  
water supply be considered to eliminate the water problem.  
Do not remove the anode leaving the tank unprotected. By  
doing so, all warranty on the water heater tank is voided.  
It is not uncommon to experience a small amount of smoke and odor  
during the initial start-up. This is due to burning off of oil from metal  
parts, and will disappear in a short while.  
THERMALEXPANSION  
“AIR” IN HOT WATER FAUCETS  
Water supply systems may, because of such events as high line  
pressure, frequent cut-offs, the effects of water hammer among  
others, have installed devices such as pressure reducing valves, check  
valves, back flow preventers, etc. to control these types of problems.  
When these devices are not equipped with an internal by-pass, and no  
other measures are taken, the devices cause the water system to be  
closed.As water is heated, it expands (thermal expansion) and closed  
systems do not allow for the expansion of heated water.  
HYDROGEN GAS: Hydrogen gas can be produced in a hot water system  
that has not been used for a long period of time (generally two weeks or  
more). Hydrogen gas is extremely flammable and explosive. To prevent  
the possibility of injury under these conditions, we recommend the hot  
water faucet, located farthest away, be opened for several minutes  
before any electrical appliances which are connected to the hot water  
system are used (such as a dishwasher or washing machine). If hydrogen  
gas is present, there will probably be an unusual sound similar to air  
escaping through the pipe as the hot water faucet is opened. There must  
be no smoking or open flame near the faucet at the time it is open.  
The water within the water tank expands as it is heated and increases the  
pressure of the water system. If the relieving point of the water heater’s  
temperature-pressurereliefvalveisreached, thevalvewillreleasetheexcess  
pressure. The temperature-pressure relief valve is not intended  
for the constant relief of thermal expansion. This is an unacceptable  
conditionandmustbecorrected.Itisrecommendedthatanydevicesinstalled  
whichcouldcreateaclosedsystemhaveaby-passand/orthesystemhave  
anexpansiontankordevicetorelievethepressurebuiltbythermalexpansion  
in the water system. Expansion tanks are available for ordering through the  
MaytagCustomerServiceCenter(1-800-788-8899).Contactthelocalplumbing  
inspector, water supplier and/orcall Maytag Customer Service at 1-800-  
788-8899 for assistance in controlling these situations.  
HIGHWATERTEMPERATURESHUTOFFSYSTEM  
This water heater is equipped with an automatic gas shut-off system. This  
system works when high water temperatures are present. Turn “OFF” the  
entire gas supply to the water heater. The high temperature shut-off is built  
intothegascontrolvalve. Itisnon-resettable. Ifthehightemperatureshut-off  
activates, thegascontrolvalvemustbereplaced. Contactyourgassupplier  
or Maytag Customer Service (1-800-788-8899).  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICE AND ADJUSTMENT  
Soot build-up indicates a problem that requires correction before further  
VENTING SYSTEM INSPECTION  
use. Turn “OFF” gas to water heater and leave off until repairs are  
made, because failure to correct the cause of the sooting can result in  
a fire causing death, serious injury, or property damage.  
FIGURE28.  
BURNER CLEANING  
In the event your burner or burner air openings require cleaning, turn the  
blower switch to the “OFF” position and allow the burner to cool. Call  
Maytag Customer Service (1-800-788-8899) to remove and clean  
the burner and correct the problem that required the burner to be cleaned.  
HOUSEKEEPING  
Vacuumaroundbaseofwaterheaterfordust, dirt, andlintonaregularbasis.  
At least once a year a visual inspection should be made of the venting  
system. You should look for:  
1. Obstructions which could cause improper venting. The combustion  
and ventilation air flow must not be obstructed.  
2. Damage or deterioration which could cause improper venting or  
leakage of combustion products.  
Be sure the vent piping is properly connected to prevent escape of  
dangerous flue gasses which could cause deadly asphyxiation.  
Obstructions and deteriorated vent systems may present serious health  
risk or asphyxiation.  
Chemical vapor corrosion of the flue and vent system may occur if air for  
combustion contains certain chemical vapors. Spray can propellants,  
cleaning solvents, refrigerator and air conditioner refrigerants, swimming  
pool chemicals, calcium and sodium chloride, waxes, bleach and process  
chemicals are typical compounds which are potentially corrosive.  
If after inspection of the vent system you found sooting or deterioration,  
somethingiswrong. Callthelocalgasutilitytocorrecttheproblemandclean  
orreplacetheflueandventingbeforeresumingoperationofthewaterheater.  
ThiswaterheaterunitissuppliedwithaplasticAirIntakeScreenthatwillfilter  
andpreventlintbuild-uponthebottomoftheflamearrestorofthisheater.To  
preventthelintbuild-uponthearrestor, thelintscreenmustbeinstalledonthe  
Base Pan with the “arrows” pointing upwards as shown in Figure 29. If the  
Air Intake Screen is missing from this heater, please contact Maytag  
Customer Service (1-800-788-8899) for a replacement part.  
BURNER OPERATIONAND INSPECTION  
Flood damage to a water heater may not be readily visible or immediately  
detectable. However, over a period of time a flooded water heater will  
createdangerousconditions whichcancauseDEATH, SERIOUSBODILY  
INJURY, ORPROPERTYDAMAGE. ContactMaytagCustomerService  
(1-800-788-8899) to replace a flooded water heater. Do not attempt to  
repair the unit! It must be replaced!  
At least once a year a visual inspection should be made of the main  
burner and the hot surface igniter assembly for proper flame  
characteristics and ignition sequences. This can be done by removing  
the Outer Door and viewing the main burner operation through the  
Viewport on the Inner Door, see Figure 1. The main burner should provide  
completecombustionofgas, igniterapidly, givereasonablyquietoperation,  
and cause no excessive flame lifting from the burner ports. If the proper  
flame characteristics are not evident (see Figure 28), make sure that the  
flow of combustion and ventilation air is not blocked on the Air Intake  
Screen at the base of the water heater (see Figure 29), the Lint screen  
on the blower assembly (see Figure 1), and in the venting system.  
FIGURE29.  
AT LEAST ONCE EVERY SIX MONTHS A VISUAL INSPECTION  
SHOULD BE MADE OF THEAIR INTAKE SCREENS ON THE BASE  
OF THE WATER HEATERAND THE BLOWERASSEMBLY. CLEAN  
IF LINT ACCUMULATIONS ARE NOTICED.  
INSTALLEDINSUITABLEAREA:Toinsuresufficientventilationandcombustion  
airsupply, properclearancesfromthewaterheatermustbemaintained. See  
“FactstoConsiderAbouttheLocationsection. Combustiblematerialssuch  
asclothing, cleaningmaterials, orflammableliquids, etc. mustnotbeplaced  
against or adjacent to the water heater which can cause a fire.  
You should also check for sooting. Soot is not normal and will impair proper  
combustion.AvisualinspectionofthemainburnerandHSIigniterassembly  
should also be done at least once a year, see Figure 28.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ANODE ROD INSPECTION  
DRAINING  
The anode rod is used to protect the tank from corrosion. Most hot water  
tanks are equipped with an anode rod. The submerged rod sacrifices  
itself to protect the tank. Instead of corroding the tank, water ions attack  
and eat away the anode rod. This does not affect the water’s taste or  
color. The rod must be maintained to keep the tank in operating condition.  
The water heater should be drained if being shut down during freezing  
temperatures. Also periodic draining and cleaning of sediment from the  
tank may be necessary.  
1. Set the blower switch to the “OFF” position.  
2. CLOSE the cold water inlet valve to the water heater.  
3. OPEN a nearby hot water faucet and leave open to allow for draining.  
Anode deterioration depends on water conductivity, not necessarily  
water condition. A corroded or pitted anode rod indicates high water  
conductivity and should be checked and/or replaced more often than an  
anode rod that appears to be intact. Replacement of a depleted anode  
rod can extend the life of your water heater. Inspection should be  
conducted by a qualified technician, and at a minimum should be checked  
annually after the warranty period.  
4. Connect a hose to the drain valve and terminate to an adequate drain.  
5. OPEN the water heater drain valve to allow for tank draining.  
NOTE: If the water heater is going to be shut down and  
drained for an extended period, the drain valve should be  
left open with hose connected allowing water to terminate  
to an adequate drain.  
TEMPERATURE-PRESSURE  
RELIEF VALVE OPERATION  
6. CLOSE the drain valve.  
7. Follow instructions in the “Filling The Water Heater” section.  
8. Follow the lighting instructions on the label or see page 23 under  
“Operating Instructions” to restart the water heater.  
DRAIN VALVE WASHER REPLACEMENT  
(See Figure 31)  
1. Turn “OFF” gas supply to water heater.  
2. Follow “Draining” instructions.  
The temperature-pressure relief valve must be manually operated at  
least once a year.  
3. Turning counterclockwise (  
screw handle.  
), remove the hex cap below the  
4. Remove the washer and put the new one in place.  
5. Screw the handle and cap assembly back into the drain valve and  
retighten using a wrench. DO NOT OVER TIGHTEN.  
6. Follow instructions in the “Filling The Water Heater” section.  
7. Check for leaks.  
8. Follow the lighting instructions in the “Operating Instructions” section  
to restart the water heater.  
FIGURE 30.  
Whencheckingthetemperature-pressurereliefvalveoperation, makesure  
that (1) no one is in front of or around the outlet of the temperature-pressure  
relief valve discharge line, and (2) that the water discharge will not cause  
any property damage, as the water may be extremely hot, see Figure 30.  
Ifaftermanuallyoperatingthevalve, itfailstocompletelyresetandcontinues  
to release water, immediately close the cold water inlet to the water heater,  
followthedraininginstructions, andreplacethetemperature-pressurerelief  
valve with a new one.  
FIGURE 31.  
Ifthetemperature-pressurereliefvalveontheapplianceweepsordischarges  
periodically, this may be due to thermal expansion. You may have a check  
valveinstalledinthewaterlineorawatermeterwithacheckvalve. Consult  
your local water supplier or Maytag Customer Service (1-800-788-8899)  
for further information. Do not plug the temperature-pressure relief valve.  
SERVICE  
If a condition persists or you are uncertain about the operation of the  
water heater contact Maytag Customer Service at 1-800-788-8899  
for an authorized servicer.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LEAKAGE CHECKPOINTS  
Use this guide to check a “Leaking” water heater. Many suspected  
“Leakers” are not leaking tanks. Often the source of the water can be  
found and corrected.  
Read this manual first. Then before checking the water heater make  
sure the gas supply has been turned “OFF”, and never turn the gas  
“ON” before the tank is completely full of water.  
If you are not thoroughly familiar with gas codes, your water heater, and  
safety practices, contact Maytag Customer Service (1-800-788-8899)  
to check the water heater.  
Never use this water heater unless it is completely filled with water. To  
prevent damage to the tank, the tank must be filled with water. Water  
must flow from the hot water faucet before turning “ON” gas to the  
water heater.  
A. Water at the blower assembly is water vapor which has condensed  
out of the combustion products. This is caused by a problem in the  
vent. Contact the gas utility.  
B. *Condensation may be seen on pipes in humid weather or pipe  
connections may be leaking.  
C. *The anode rod fitting may be leaking (anode is located under the  
BlowerAssembly).  
D. Small amounts of water from temperature-pressure relief valve  
may be due to thermal expansion or high water pressure in your  
area.  
E. *The temperature-pressure relief valve may be leaking at the tank  
fitting.  
F. Water from a drain valve may be due to the valve being slightly  
opened.  
G. *The drain valve may be leaking at the tank fitting.  
H. Combustion products contain water vapor which can condense on  
the cooler surfaces of the tank. Droplets form and drip onto the  
burner or run on the floor. This is common at the time of start-up  
after installation and when incoming water is cold.  
I. Water in the water heater bottom or on the floor may be from  
condensation, loose connections, or the relief valve. DO NOT replace  
the water heater until a full inspection of all possible water sources  
is made and necessary corrective steps taken.  
Leakage from other appliances, water lines, or ground seepage should  
also be checked.  
*
To check where threaded portion enters tank, insert cotton swab  
between jacket opening and fitting. If cotton is wet, follow “Draining”  
instructions in the “Periodic Maintenance” section and then remove  
fitting. Put pipe dope or teflon tape on the threads and replace.  
Then follow “Filling the Water Heater” instructions in the “Installation  
Instructions” section.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING GUIDELINES  
These guidelines should be used by a qualified Maytag Customer Service CenterAgent. Call the Maytag Customer Service Center at  
1-800-788-8899 for assistance. Inform the associate that this is a “Flammable Vapor Ignition Resistant” Product.  
PROBLEM  
SOLUTION  
LED STATUS  
An open earth ground circuit to the  
ignition system.  
1. Check that the earth ground connection is  
properly connected.  
A
B C  
2. Check that the ground conductor on the  
water heater is properly connected.  
Wiring error or a high resistance to  
earth ground.  
1. Check for proper connection of line  
neutral and hot wires.  
2. Check that the water heater is securely  
connected to earth ground.  
A
A
B C  
B C  
Pressure switch remained closed longer  
than 5 seconds after the call for  
heat began.  
1. Pressure switch wiring is incorrect.  
2. Replace pressure switch.  
Pressure switch remained open longer  
than 5 seconds after the combustion  
blower was energized.  
1. Pressure switch wiring is incorrect.  
2. Pressure switch tubing not connected  
correctly.  
A
A
B C  
B C  
3. Air intake or exhaust obstructed.  
Error in the hot surface ignitor circuit.  
System in lockout.  
1. Check that all wiring is correct and secure.  
2. Replace hot surface ignitor.  
1. Gas supply is off or too low to operate.  
2. Hot surface ignitor not positioned  
correctly.  
A
B C  
3. Low voltage to the water heater.  
4. Electric polarity to unit is incorrect - test  
and correct.  
A
A
A
B C  
B C  
B C  
Problem in the gas valve driver circuit.  
Problem with the internal circuit.  
Problem with the internal circuit.  
1. Turn power to the water heater off for  
10 seconds and the back on.  
2. Replace gas control valve.  
1. Turn power to the water heater off for  
10 seconds and then back on.  
2. Replace gas control valve.  
1. Turn power to the water heater off for  
10 seconds and then back on.  
2. Replace gas control valve.  
A
A
B C  
B C  
Flame signal sensed out of  
proper sequence.  
1. Replace gas control valve.  
ECO activated.  
1. Replace gas control valve.  
A
A
A
B C  
B C  
B C  
One of the temperature adjust  
buttons stuck closed.  
1. Press and release each of the buttons  
once.  
2. Replace gas control valve.  
Water temperature sensor is  
either open or short circuited.  
1. Check that all wiring is correct and secure.  
2. Replace gas control valve.  
Unit shuts down and in lockout.  
1. Clean and reinstall the air intake screen.  
2. Clean and reinstall the lint screen on the  
Blower assembly.  
A
A
B C  
B C  
Unit shuts down.  
1. Check for correct wiring to FV sensor.  
2. Check for open circuits to FV sensor.  
3. Replace FV sensor.  
Unit shuts down and in lockout.  
1. FV sensor detected presence of flammable vapors.  
2. Contact Maytag Customer Service (1-800-788-8899)  
to determine cause.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING GUIDELINES  
These guidelines should be used by a qualified Maytag Customer Service CenterAgent. Call the Maytag Customer Service Center at  
1-800-788-8899 for assistance. Inform the associate that this is a “Flammable Vapor Ignition Resistant” Product.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REPAIR PARTS LIST  
MAYTAG GAS WATER HEATER  
MODEL NO’S  
40 Gallon Natural Gas  
HV640YBVITCGA  
HV650YBVITCGA  
HV640HBVITCGA  
HV650HBVITCGA  
50 Gallon Natural Gas  
40 Gallon Propane (L.P.)  
50 Gallon Propane (L.P.)  
BURNERASSEMBLY  
OUTER DOOR  
(ALTERNATE)  
1
16  
Model Numbers  
Key No. Part Description  
HV640YBVIT  
TBD  
66001494  
TBD  
HV650YBVIT  
HV640HBVIT  
TBD  
TBD  
66001540  
TBD  
HV650HBVIT  
TBD  
TBD  
66001540  
TBD  
1
2
BurnerAssembly  
Burner Head  
TBD  
66001494  
TBD  
3
Burner Orifice  
4
Burner Tube  
TBD  
TBD  
5
6
7
8
HSI IgnitionAssembly  
Inner Door  
Inner Door Gasket  
Flue Baffle  
TBD  
TBD  
TBD  
TBD  
66001499  
66001500  
TBD  
66001498  
66001500  
TBD  
66001499  
66001500  
TBD  
66001498  
66001500  
TBD  
9
Flue Restrictor  
66001513  
TBD  
66001503  
66001646  
TBD  
66001016  
66001021  
TBD  
66001513  
TBD  
66001503  
66001307  
TBD  
66001016  
66001021  
TBD  
66001832  
66001079  
66001509  
TBD  
66001513  
TBD  
66001503  
66001646  
TBD  
66001016  
66001021  
TBD  
66001513  
TBD  
66001503  
66001307  
TBD  
66001016  
66001021  
TBD  
66001832  
66001079  
66001509  
TBD  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
**20  
BlowerAssembly  
Air Intake Screen - Base Pan  
Inlet Tube  
Gas Control Valve  
Drain Valve  
Drain Valve Washer  
Outer Door  
Anode Rod  
TBD  
TBD  
Temperature-Pressure Relief Valve  
ViewportAssembly  
66001079  
66001509  
TBD  
66001079  
66001509  
TBD  
20" Dia. Drain Pan w/Side Drain (optional)  
22" Dia. Drain Pan w/Side Drain (optional)  
24" Dia. Drain Pan w/Side Drain (optional)  
28" Dia. Drain Pan w/Side Drain (optional)  
Instruction Manual  
TBD  
TBD  
TBD  
TBD  
TBD  
TBD  
TBD  
TBD  
TBD  
TBD  
TBD  
TBD  
*21  
22  
23  
185374-000  
TBD  
185374-000  
TBD  
185374-000  
TBD  
185374-000  
TBD  
Air Intake Screen - BlowerAssembly  
FV Sensor  
TBD  
TBD  
TBD  
TBD  
24  
FV Sensor Bracket  
TBD  
TBD  
TBD  
TBD  
**25  
**26  
Nipple with Heat Trap  
SecondaryAnode with Heat Trap  
TBD  
TBD  
TBD  
TBD  
TBD  
TBD  
TBD  
TBD  
* Not shown ** Optional TBD (to be determined by Maytag)  
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE  
FOLLOWING INFORMATION:  
Now that you have purchased your gas water heater, should  
a need ever exist for repair parts or service, simply consult  
Maytag Customer Service at 1-800-788-8899 for an  
authorized installer on how to control this situation.  
MODEL NUMBER  
TYPE GAS (NATURAL OR PROPANE (L.P.)  
SERIAL NUMBER  
Be sure to provide all pertinent facts when you call or visit.  
PART DESCRIPTION  
The model number of your Gas Water Heater will be found  
on the rating place located above the gas control valve.  
THIS ISAREPAIR PARTS LIST, NOTAPACKING LIST.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
FULLONEYEAR WARRANTY  
For one year from the date of original retail purchase, any part which fails in normal home use will be repaired  
or replaced free of charge.  
If a leak occurs in the tank, a new water heater of the closest capacity and quality then available, will be  
replaced free of charge.  
The warranty of the replacement is the balance of the original water heater’s warranty.  
LIMITED PARTS WARRANTY  
After the first year and through the sixth year from the date of original retail purchase, any parts which fail due  
to a defect in materials or workmanship, will be replaced or repaired free of charge for the part itself, with the  
owner paying all other costs, including labor, mileage and transportation.  
If the water heater is subjected to commercial, institutional, industrial or non-residential use, the above  
warranty coverage for parts that are proved to be defective in material or workmanship is effective for one year  
from the date of the original retail purchase.  
The warranty of the replacement is the balance of the original water heater’s warranty, or twelve months from  
the date of the part(s) purchase, whichever comes first.  
This warranty is limited to the original owner of the water heater.  
LIMITED TANK WARRANTYAGAINST LEAKS  
After the first year and through the sixth year from the date of original retail purchase, if a leak occurs in the  
tank, a new water heater of the closest capacity and quality then available, will be replaced free of charge for  
the water heater, with the owner paying all other costs, including labor, mileage and transportation.  
If the water heater is subjected to commercial, institutional, industrial or non-residential use, the above  
warranty coverage for the tanks that are proved to be defective in material or workmanship is effective for two  
years from the date of the original retail purchase.  
The warranty of the replacement is the balance of the original water heater’s warranty.  
Please note: The full and limited warranty applies only while this water heater is used in Canada.  
This warranty is limited to the original owner of the water heater.  
TO RECEIVE WARRANTYSERVICE  
To locate an authorized service company in your area contact the Maytag dealer from whom your appliance  
was purchased; or call Maytag Customer Service at the number listed below. Should you not receive satisfactory  
warranty service, please call or write:  
Maytag Customer Service  
P.O. Box 2370  
Cleveland, TN 37320-2370  
Canada 1-800-788-8899  
When contacting Maytag Customer Service be sure to provide the model and serial number of your appliance,  
the name and address of the dealer from whom you purchased the appliance and the date of purchase.  
MAYTAG WATER HEATERS ARE MANUFACTURED AND THIS WARRANTY IS PROVIDED BYA. O. SMITH  
CORPORATION. MAYTAG® IS A TRADEMARK OF THE MAYTAG CORPORATION AND IS USED UNDER  
LICENSE TOA. O. SMITH CORPORATION.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Land Pride Lawn Mower FDR16 Series User Manual
Lanzar Car Audio Car Stereo System VBD500 User Manual
Linear Home Security System AM KPI User Manual
Linksys Home Theater Server WMCE54AG User Manual
Linksys Network Card USB100TX User Manual
Margaritaville Gas Grill NBMGLG1000 User Manual
Maytag Range AGR4400ADW User Manual
Metabo Grinder GA 18 LTX G User Manual
Metra Electronics Automobile Accessories 99 2004 User Manual
Metrologic Instruments Barcode Reader SP5600 User Manual