Electric Dryer Installation Instructions
OVERALL DIMENSIONS
Dryer dimensions
PRODUCT MODEL NUMBERS
MED6000X, MED7000X, MED9000X
Front view:
Side view:
507/8"
(1292 mm)
27"
(686 mm)
305/8"
(728 mm)
Electrical: This dryer requires a 3 or 4 wire, single
phase, 120/240 volt, 60 Hz., AC only electrical supply
(or 3 or 4 wire, 120/208 volt electrical supply, if speci-
fied on the serial/rating plate) on a separate 30-amp
circuit, fused on both sides of the line. A time-delay
fuse or circuit breaker is recommended. Connect to
an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
381/8"
(968 mm)
Water (Steam models only): The dryer must be
connected to the cold water faucet using new inlet
hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
3/4"*
Exhaust venting: Exhaust your dryer to the outside.
4" (102 mm) diameter vent is required. Rigid or flexible
metal exhaust vent must be used. Do not use plastic
or metal foil vet. Exhaust hood must be at least
12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
3/4"*
(18 mm)
(18 mm)
Back view:
61/2"
(165 mm)
Hood styles: A & B are recommended.
NOTE: Most installations require a
minimum of 5" (127 mm) clearance
behind dryer for exhaust vent with
elbow. See “Venting Requirements.”
297/8"*
(759 mm
31/2"*
(89 mm)
C
B
A
A. Louvered hood
B. Box hood
C. Angled hood (acceptable)
61/8"*
(156 mm)
3/4"*
(18 mm)
* Approximate measurement
143/8"
(365 mm)
The Vent system chart provides venting requirements
that will help achieve best drying performance.
Closet installation (dryer only):
NOTE: Side and bottom exhaust installation have a 90°
turn inside the dryer. To determine maximum exhaust
length, add a 90° turn to the total number of elbows
when referemcing the chart.
3"
(76 mm)
18" min.
(457 mm)
48 in.2 min.
(310 cm2)
Vent system chart
Number of
90° elbows
Type
Box/louvered
Angled
hoods
of vent
hoods
For closet installation, with a door,
the minimum ventilation openings
Rigid metal
64 ft. (20 m)
58 ft. (17.7 m)
0
1
2
3
24 in.2 min. in the top and bottom of the door
(155 cm2)
5"
are required. Louvered doors with
equivalent air ventilation openings
are acceptable.
Rigid metal 54 ft. (16.5 m) 48 ft. (14.6 m)
3"
(76 mm)
(127 mm)
Rigid metal 44 ft. (13.4 m) 38 ft. (11.6 m)
1"
(25 mm)
1"
(25 mm)
Rigid metal 35 ft. (10.7 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Rigid metal 27 ft. (8.2 m)
4
Do not use vent runs longer than specified in vent
length chart.
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
Use the fewest 90° turns possible.
Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.