Marathon Computer Server FTvirtual Server User Manual

Marathon Technologies FTvirtual  
TM  
TM  
Server and IBM BladeCenter  
Installing and Configuring a Fault-Tolerant Windows  
Environment for Mission Critical Applications  
Marathon Technologies Corporation  
888.682.1142  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trademark Notice  
Endurance, Marathon Assured Availability, Marathon  
FTvirtual Server, and the Marathon logo are either regis-  
tered trademarks or trademarks of Marathon Technolo-  
gies Corporation in the United States and/or other  
countries.  
Microsoft, MS-DOS, and Windows are registered trade-  
marks of Microsoft Corporation in the United States and/  
or other countries.  
IBM eServer BladeCenter and IBM are registered trade-  
marks of the International Business Machines Corpora-  
tion in the United States and/or other countries.  
All other brands and product names are trademarks of  
their respective companies or organizations.  
Software Revision  
The revision of the software that this document supports is  
Revision 6.1.1.  
This section describes the technical changes made in  
this edition of the Marathon Technologies FTvirtual Serv-  
erTM and IBM eServer BladeCenterTM - A Fault-Tolerant  
Environment for Mission Critical Windows Applications  
application note. Minor changes and editorial corrections  
may also be included that are not identified.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Summary of changes  
Summary of changes for  
Marathon Technologies FTvirtual Server and IBM  
eServer BladeCenterTM - A Fault-Tolerant Environment  
for Mission Critical Windows  
as created or modified on 9/2/05.  
September 2005, First Edition  
1.0.0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Contents  
Contents  
Introduction  
Planning and Preparation  
Marathon Technologies Corporation  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Installing the Endurance Software  
2
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 1  
Introduction  
This chapter discusses the key advantages of IBM BladeCenter and Mara-  
thon Technologies FTvirtual Server and how they combine to create a truly  
fault-tolerant environment for mission critical Windows applications.  
Fault-Tolerant Computing for Mission Critical  
Windows Applications  
The Trend Toward Blades  
Blade configurations like the IBM BladeCenter have become popular  
because they provide several key advantages over conventional pedestal  
or rack-mounted servers. These advantages include:  
Flexibility and Ease of Installation  
Because blades get their electrical power and network interconnections  
from the chassis, adding processing power to an existing chassis is as  
simple as inserting the blade and configuring its software and network  
address. No additional cabling or electrical power connections are  
required.  
Ease of Management  
System management tools like the IBM Director permit hundreds of  
blade servers to be maintained remotely through use of a single graphi-  
cal console. This tool provides a common management view across  
multiple servers in a chassis and enables a smaller IT staff to manage  
the same number of servers.  
Marathon Technologies Corporation  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Introduction  
Reduced Floor Space Usage in the Data Center  
Modular design reduces cost through more efficient use of valuable floor  
space. The increased density can significantly reduce the space require-  
ments in a data center.  
Reduced Cost of Power and Cooling  
Blades servers integrate resources and share key components. Since  
blades in a chassis share common power supplies, power is distributed  
more efficiently and less heat is generated for a given amount of pro-  
cessing power.  
Increased Reliability and Availability  
Since the BladeCenter may be configured with redundant hot-swap  
power supplies and built-in network switches, it effectively eliminates  
several key single points of failure and provides greater system availabil-  
ity than conventional rack-mount servers. The BladeCenter also  
reduces down-time due to server failure by making replacement of a  
failed server easy.  
Mission-Critical Blades: The Need For Fault Tolerance  
As enterprises move more compute load to blade servers, blades are  
becoming increasingly mission-critical. Because downtime has significant  
associated costs - lost sales, decreased customer satisfaction, lost produc-  
tivity - the need for a simple, affordable way to keep blades running continu-  
ously is becoming urgent. Four trends are converging to further increase  
the need for continuously available blades:  
Improved server density and server consolidation increases the  
potential risk to business operations in the event of downtime by  
“putting all your eggs in one basket”  
Increasingly stringent regulations require data retention and avail-  
ability  
More threats to security and physical systems  
Increasing complexity of enterprise infrastructure, and impact of  
system downtime  
2
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Marathon FTvirtual Server - Fault-Tolerance Through Software  
To address the need for continuous availability of mission-critical applica-  
tions, Marathon Technologies has designed its FTvirtual Server software to  
work with blade server configurations as well as traditional servers.  
Marathon software harnesses the redundancy provided by two BladeCenter  
servers to create a true, fault- tolerant environment for Windows applica-  
tions.This is accomplished by loading the Marathon software on any two  
blade servers and interconnecting them via the BladeCenter’s integrated  
chassis switching matrix. The Marathon software synchronizes the two  
servers and creates a virtual application environment that runs on both  
servers simultaneously. If either server in the connected pair fails, the appli-  
cation environment continues to function uninterrupted, using the process-  
ing power of the other. Unlike typical clustering technologies which require  
seconds or even minutes to “fail-over” application processing and may  
incure data loss, there is no failover with Marathon software, so there is no  
downtime.  
The result is a truely fault-tolerant Windows environment for BladeCenter  
configurations. Enterprises get all the cost savings and operational efficien-  
cies of the BladeCenter while protecting their business-critical Windows  
applications and data, even in the event of a blade failure.  
Conclusion  
Blade servers are helping companies save money and increase efficiency  
and flexibility in their data centers. However, without adequate fault protec-  
tion, these benefits are soon lost in the event of downtime. Marathon’s  
FTvirtual Server software delivers a simple, affordable way to protect impor-  
tant applications and data running on IBM eServer BladeCenter configura-  
tions.  
Marathon Technologies Corporation  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Introduction  
4
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHAPTER 2  
Planning and Preparation  
This chapter describes BladeCenter features and options, key design con-  
cepts, and basic configuration guidelines you should be aware of before  
beginning to install and setup a BladeCenter FTvirtual Server.  
Planning the Installation  
Before starting the Endurance software installation you should consider  
several major configuration related issues, which will effect the overall oper-  
ation and capability of your FTvirtual Servers.  
FTvirtual Server Boot Disk Options  
The Endurance software allows the FTvirtual Server boot disk to be  
installed on either a separate physical disk or as a Virtual disk. If your blade  
configuration is limited to a single on-board physical disk you will need to  
use a Virtual boot disk for the FTvirtual Server. A virtual boot disk allows  
you to share a single physical disk as both the CoServer and the FTvirtual  
Server Windows boot disk. Disk space is allocated to a file on the CoServer  
disk. The content of the file is then formatted, partitioned, and used as the  
FTvirtual Server boot disk.  
Marathon Technologies Corporation  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Planning and Preparation  
Network Environment  
The optimal FTvirtual Server configuration uses 4 network adapters per  
blade to support CoServer communications and client access links critical  
to applications. These links provide the mechanisms and transport for redi-  
rected network I/O, FTvirtual Server communications and fault manage-  
ment activities.  
When using the optimal network configuration, two of the adapters in each  
blade will support CoServer Links (CSLink) 1 and 2, which are primarily  
used for disk mirroring and memory synchonization operations. A third  
adapter in each blade is used for CoServer out-of-band remote administra-  
tion and SNMP management activities. The fourth serves as a redirected  
network link permitting the FTvirtual Server to satisfy client and application  
I/O requests.  
CoServer and Switchbay Network Connections  
A sample BladeCenter network map depicting the connections for two  
FTvirtual Server configurations (FTv1 and FTv3) is shown in Figure 1. This  
configuration demonstrates the optimal BladeCenter FTvirtual Server con-  
figuration, maximizing server fault-tolerance and network availability.  
It should be mentioned that although each switchbay is internally intercon-  
nected with each slot of the BladeCenter chassis, these additional connec-  
tions have been left out of the diagram for the sake of simplicity.  
Note that in this 4 NIC configuration switchbays 1 and 2 provide dedicated  
CSLink 1 and CSLink 2 switching capability for each of the FTv CoServers.  
These connections are made internally to the BladeServer chassis and  
none of the external ports available on these two switches are used for  
external connections.  
Switchbays 3 and 4 are configured for FTvirtual Server Redirected and  
Management use. The four external ports available on these switches are  
used to connect the FTvirtual Server/s to the public network.  
6
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
FIGURE 1. Sample BladeCenter Network Adapter Switchbay Map  
FTv1 CoServer 1  
PCI 1:0:0 NIC  
Switch Bay 1  
CSLink 1 connections only  
No external connections  
PCI 1:0:1 NIC  
PCI 2:2:1 NIC  
PCI 2:2:0 NIC  
FTv1 CoServer 2  
PCI 1:0:0 NIC  
Switch Bay 2  
CSLink 2 connections only  
No external connections  
PCI 1:0:1 NIC  
PCI 2:2:1 NIC  
PCI 2:2:0 NIC  
FTv2 CoServer 1  
FTv2 CoServer 2  
Switch Bay 3  
Redirected for CoServer 1  
Management for CoServer 2  
To  
Network  
Switch Bay 4  
Redirected for CoServer 2  
Management for CoServer 1  
FTv3 CoServer 1  
PCI 1:0:0 NIC  
To  
Network  
PCI 1:0:1 NIC  
PCI 2:2:1 NIC  
PCI 2:2:0 NIC  
FTv3 CoServer 2  
PCI 1:0:0 NIC  
PCI 1:0:1 NIC  
PCI 2:2:1 NIC  
PCI 2:2:0 NIC  
Blade Bays 1, 5, 9 are assumed to contain CoServer 1  
Blade Bays 3, 7, 11 are assumed to contain CoServer 2  
Blade Bay pairs 1 & 3, 5 & 7, 9 & 11 each make an Endurance system  
Marathon Technologies Corporation  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Planning and Preparation  
Network Adapter Configurations  
Depending upon your specific switchbay and blade on-board device config-  
uration, it is possible that fewer than 4 adapters will be available for use.  
When planning a BladeCenter network configuration your primary concern  
should be to maximize the availability of the redirected network links and  
minimize utilization of external networks by the CoServer links.  
To maximize the availability of the redirected links, different switches  
should be used to connect the CoServers to the external network. To mini-  
mize utilization of the external network by the CoServer links, both CoServ-  
ers should use the same internal switch for a CSLink connection. Routing a  
CSLink connection through the same switch will confine all associated traf-  
fic to that switch. Several recommended network configurations using 4, 3,  
and 2 network adapters are shown in the following tables.  
TABLE 1. 4 NIC Configuration  
Function  
CoServer 1  
Switchbay 1  
Switchbay 2  
Switchbay 3  
Switchbay 4  
CoServer 2  
Switchbay 1  
Switchbay 2  
Switchbay 4  
Switchbay 3  
Comment  
CSLink 1  
Internal Bandwidth  
CSLink 2  
Redirected  
Manage  
Internal Bandwidth  
Redundant External Connection  
Redundant External Connection  
TABLE 2. 3 NIC Configuration  
Function  
CSLink 1  
CoServer 1  
CoServer 2  
Switchbay 1  
Switchbay 3  
Switchbay 2  
Comment  
Switchbay 1  
Switchbay 2  
Switchbay 3  
Internal Bandwidth  
Redirected  
CSLink 2  
Redundant External Connection  
Exposed network utilization  
Requires network routed IP  
addresss  
TABLE 3. 3 NIC Alternate Configuration  
Function  
CSLink 1  
CoServer 1  
Switchbay 1  
Switchbay 2  
Switchbay 3  
CoServer 2  
Switchbay 1  
Switchbay 3  
Switchbay 2  
Comment  
Internal Bandwidth  
Redirected  
Manage  
Redundant External Connection  
Redundant External Connection  
8
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
TABLE 4. 2 NIC Configuration  
Function  
CoServer 1  
CoServer 2  
Comment  
CSLink 1  
Switchbay 1  
Switchbay 2  
Exposed network utilization.  
Requires network routed IP  
address.  
Redirected  
Switchbay 2  
Switchbay 1  
Redundant External Connection  
For More Information  
For more information on setting-up network configurations, Virtual boot  
disks and other preparation issues consult the following resources located  
on your Marathon software distribution CD-ROM:  
Administrator’s Guide  
Upgrading Endurance Software  
Configuration and Installation Guide  
Marathon Technologies Corporation  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Planning and Preparation  
Preparing to Install  
BladeCenter Options  
An IBM eServer BladeCenter may be configured using a variety of storage  
and networking options. For example, the BladeCenter chassis using HS20  
blade servers offers the following configuration features:  
A rack-optimized 7U modular 14 slot chassis that can support a  
total of 14 hot-swap BladeCenter HS20 blades.  
A CD-ROM and floppy shared by all blade bays.  
A maximum of two Management modules integrating remote man-  
agement functions and a 14-port Keyboard/Video/Mouse switch.  
Up to 4 Gigabit Ethernet Switch modules. Each switch has four  
external ports as well as 14 internal ports (one to each bay).  
HS20 hot-swappable blades supporting two XEON processors, 4-  
port Gigabit Ethernet modules, on-board disks and/or a piggy-  
backed SCSI drive Expansion Unit.  
10  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
FTvirtual Server and Blade Configuration  
Each Endurance FTvirtual Server configuration is comprised of two blades.  
Following installation of the Endurance software each will function as a  
CoServer to create the FTvirtual Server environment.  
Depending upon the specific configuration, a 14 slot BladeCenter chassis  
can support a total of 7 Endurance FTvirtual Servers (2 slots per FTvirtual  
Server), using single-slot blades configured with one or two on-board disks  
and four network adapters. If each blade is configured with four network  
adapters and a piggy-backed SCSI Expansion Unit option for increased  
storage capacity, a total of 3 Endurance configurations (4 slots per FTvirtual  
Server) may be supported.  
It is important to note that the chassis slot position of a blade has no impact  
on its function. After an Endurance system has been established, the  
blades can be moved to any chassis slot and located in any order. Data  
communications between Endurance configured blades is controlled by IP  
addresses, which are unique to a blade and FTvirtual Server blade pair.  
Identifying Network Components  
To help simplify Endurance software installation it is suggested that you first  
create a chart that maps blade configured network adapters to their corre-  
sponding ethernet switchbay connection. Since this mapping may vary  
across blade (HSxx) models, it is important that you identify these connec-  
tions prior to installation. Later, during the network setup phase of the instal-  
lation you will be able to correlate a CoServer assigned networking role to  
its corresponding adapter and ethernet switchbay connection.  
A specific network adapter must be identified by its unique PCI bus location  
in the system in terms of:  
“PCI bus b, device d, function f”  
Switchbays may be identified from the back of the BladeCenter cabinet by  
the number of the particular bay they reside in.  
Marathon Technologies Corporation  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Planning and Preparation  
Mapping the Switchbays  
After installation of the Windows operating system on a blade you can fill-in  
the switchbay mapping table for your particular configuration using the fol-  
lowing procedure.  
Note: Do not perform PCI-to-Switchbay mappings when blades  
within the chassis are operating within a production  
environment.  
1. On one of the CoServer blades right-click My Network Places to view  
the Network Connections dialog.  
2. From the back of the BladeCenter cabinet select a switchbay and unplug  
it.  
3. Return to the CoServer console and observe the Network Connections  
dialog and note which connection experiences a status change.  
4. Right-click on the connection that changed status to display the Local  
Area Connection Properties.  
5. Click the Configure button to display the controller properties. Note the  
switchbay number of the switch you unpluged and record the corre-  
sponding PCI location information for that adapter in Table 4. Plug the  
switchbay back into its slot and wait for the connection status to return to  
normal.  
6. Repeat this procedure for each configured ethernet switchbay until you  
have identified all connections. Since these connections will hold for like  
blade models this mapping will work for all other configured blades.  
TABLE 5. Adapter PCI-to-Switchbay Mappings  
Blade Model  
Switchbay 1  
Switchbay 2  
Switchbay 3  
Switchbay 4  
Blade HS20  
1:0:0 (b:d:f)  
1:0:1 (b:d:f)  
2:2:1 (b:d:f)  
2:2:0 (b:d:f)  
8832 Chassis  
Blade HS20  
5:1:0  
5:1:1  
6:1:0  
6:1:1  
8843 Chassis  
Blade HSXX  
88nn Chassis  
12  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CHAPTER 3  
Installing the Endurance  
Software  
This chapter describes in detail how to install and configure the Endurance  
software on each of the BladeCenter CoServers to create the FTvirtual  
Server.  
Major Installation Tasks  
The major installation tasks are:  
1. Install Windows on both CoServers.  
2. Install Endurance software on CoServer 1.  
3. Install Endurance software on CoServer 2.  
4. Install Windows on and configure the FTvirtual Server  
Marathon Technologies Corporation  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the Endurance Software  
Windows Installation  
Before you begin the Endurance installation, install Windows and set the  
size of the event logs.  
Installing Windows on the CoServers  
On both CoServers:  
Install the appropriate Windows software and Service Packs. Refer to the  
Endurance Release Notes for information about hardware and software  
requirements, including Windows Security Updates.  
Note: If the Manage Your Server or Configure Your Server window  
appears, click Don’t display this page at logon, and then  
dismiss the window.  
Event Log Recommendations  
On both CoServers:  
For best results in tracking system events, make sure that the Application  
Log and System Log on both CoServers are set to at least 16384 KB.  
From Computer Management, select Event Viewer. For each log:  
Right click, and select Properties.  
If necessary, change the Maximum log size to at least 16384 KB. Verify  
that the Overwrite events as needed box is checked.  
14  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Disk Partitioning and Formatting  
The Windows operating system for the FTvirtual Server will be installed on  
a disk of each blade CoServer. You can select a physical disk in the CoS-  
erver for the FTvirtual Server boot disk or you can install the FTvirtual  
Server on an Endurance Virtual disk. A Virtual boot disk is a CoServer disk  
that you can create by allocating space in the file system of any existing  
CoServer disk and then, using Endurance software, creating a Virtual disk  
from this file space. The Virtual disk can then be mounted, formatted and  
partitioned like any physical disk. This allows you to use one physical disk  
for booting both the CoServer and the FTvirtual Server on blade systems  
configured with only a single physical disk.  
If you wish to install the FTvirtual Server boot disk on a physical disk, con-  
tinue on with the next section. If you want to install the FTvirtual Server boot  
disk on a Virtual disk skip the next section and proceed to Installing Endur-  
ance Software on the CoServers. Setup of the Virtual disk will be covered  
later during the CoServer installation procedure.  
Marathon Technologies Corporation  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the Endurance Software  
Installing the FTvirtual Server Boot Disk on a Physical Disk  
On CoServer 2:  
The disk for the FTvirtual Server software must be Basic and formatted to  
use the NTFS file system.  
1. Right-click My Computer, then select Manage  
Computer Manage-  
ment Storage and then Disk Management. Make sure Disk 1 is  
basic, not dynamic.  
2. If the partition is not basic, right click and select Revert to Basic.Right-  
click on unallocated Disk 1, and use the wizard that creates partitions to  
create the FTvirtual Server boot drive.  
Select Primary partition.  
Specify the partition size.  
Assign a drive letter. Record this drive letter for later use during  
FTvirtual Server installation.  
Format the partition using NTFS.  
Rename the drive (volume label) FTv boot drive.  
3. Mark the drive active.  
If you plan to use additional disks for applications, make sure that  
they are designated Basic and not Dynamic.  
16  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4. Verify the destination on the Ready to Install window, and click Install.  
5. Click Finish on the Completing the Endurance Quorum Service  
Setup Wizard.  
Marathon Technologies Corporation  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the Endurance Software  
Installing Endurance Software on the CoServers  
Before You Begin the Software Installation  
Have your Endurance software license number available. You need  
to type it when you install the software on the CoServers.  
Know the PCI location-to-switchbay mappings for each network  
adapter. This information will be used when the Endurance Net-  
work Setup runs.  
Make sure all network connections are Enabled and connected.  
Right click on My Network Places and select Properties. Exam-  
ine the status of each connection. If the connection is Disabled,  
you must Enable that connection. Make sure each connection has  
a status of Connected.  
Gather information for installing Windows on the FTvirtual Server:  
-
-
-
-
-
The Windows license type: Per server or Per seat  
The computer name  
The user name  
The organization name  
The Windows Product Key  
Note: If you are slip streaming for the FTvirtual Server’s Service Pack,  
refer to the Microsoft documentation for information about  
preparing the Windows installation. After the Service Pack is  
applied, it takes the place of the Windows distribution media.  
18  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
CoServer 1 Installation  
Starting the Installation  
1. Insert the Endurance CD. If your CD does not automatically launch the  
Installation Launcher, browse the CD and double click on setup.exe.  
2. From the Installation Launcher, select Install CoServer, and follow the  
prompts through the Welcome, License Agreement, and Information  
dialogs to the Customer Information dialog.  
3. Type a user name, company name, and the license number (including  
the dashes).  
4. Verify the name, company, and license number on the Registration  
Confirmation page.  
5. In the Select Features window, choose the components you want to  
install.  
Select Basic Product, the default.  
Marathon recommends that you also install the other defaults: Doc  
umentation and SNMP Support.  
Marathon Technologies Corporation  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the Endurance Software  
6. Select CoServer1 for installation.  
Specify the Location of the Software  
1. On the Choose Destination Location window, save the files in the  
default location C:\Program Files\Marathon\Endurance or  
specify another location.  
2. On the Confirm New Folder window, click Yes.  
3. Verify the information on the Check Setup Information window. Click  
Next.  
20  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Configure the Network using the Endurance Network Setup Wizard  
If you are installing on a Windows 2003 system, the following Security Alert  
may appear.  
Click Yes to continue with Endurance Network Setup.  
Marathon Technologies Corporation  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the Endurance Software  
The Endurance Network Setup wizard starts to guide you through the task  
of configuring the adapters. Click Next to begin.  
1. On the Configure Redirected page, enter 1 in the Specify total num-  
ber of Redirected adapters box and highlight the adapter you wish to  
assign as redirected in the Connection column. Select the adapter to be  
used based upon the PCI location-to-switchbay mapping you estab-  
lished during planning and preparation. Click Next to continue.  
22  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. On the Configure CoServer Link1 page, highlight the adapter you wish  
to assign as CoServer Link1 in the Connection column. Select the  
adapter based upon the PCI location-to-switchbay mapping you estab-  
lished during planning and preparation. You can use Table 1 to assign IP  
addresses for internal CLink connections.  
TABLE 1. Suggested CoServer1 CLink IP Addresses  
Blade Pair 1  
Blade Pair 2  
Blade Pair 3  
CoServer1  
CoServer2  
CoServer1  
CoServer2  
CoServer1  
CoServer2  
192.168.3.1  
192.168.3.2  
192.168.13.1  
192.168.13.2  
192.168.23.1  
192.168.23.2  
CSLink1  
CSLink2  
192.168.4.1  
192.168.4.2  
192.168.14.1  
192.168.14.2  
192.168.24.1  
192.168.24.2  
Note: When installing multiple blade pairs, the first blade pair will have  
the same IP for both the default IP and the currently configured  
IP. This will not be the case for subsequent blade pairs.  
Marathon Technologies Corporation  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the Endurance Software  
Right click on the your adapter selection and choose Internet Protocol  
Properties from the action menu. On the Internet Protocol Properties  
page select Use the following IP address. Fill-in the appropriate IP  
address from Table 1 for this adapter. Then, enter Subnet mask  
255.255.255.0 and click OK.  
24  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
On the Endurance Network Setup page make sure that the desired  
adapter is still highlighted and select Use currently configured IP  
addressing. Click Next to continue.  
3. If your network configuration will not use CoServer Link 2, select No  
Coserver Link 2 and then click Next without selecting an adapter.  
If you will be using CoServer Link 2, then on the Configure CoServer  
Link2 page, highlight the adapter you wish to assign as CoServer Link2  
in the Connection column. Select the adapter based upon the PCI loca-  
tion-to-switchbay mapping you established during planning and prepara-  
tion. You can use Table 1 to assign IP addresses for internal CLink  
connections.  
Right click on the adapter selection and choose Internet Protocol Prop-  
erties from the action menu. On the Internet Protocol Properties page  
select Use the following IP address and fill-in the appropriate address.  
Then, enter Subnet mask 255.255.255.0 and click OK.  
On the Endurance Network Setup page make sure that the desired  
adapter is still highlighted and select Use currently configured IP  
addressing. Click Next to continue.  
Marathon Technologies Corporation  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the Endurance Software  
4. If your network will not use a CoServer Management connection, push  
Next without highlighting an adapter.  
If you will be using CoServer Management, then on the Configure CoS-  
erver Management page, highlight the adapter you wish to assign for  
CoServer Management in the Connection column. Select the adapter  
based upon the PCI location-to-switchbay mapping you established dur-  
ing planning and preparation.  
If you wish to assign an IP address, right click on the selection and  
choose Internet Protocol Properties from the action menu. On the  
Internet Protocol Properties page select Use the following IP  
address, fill-in the appropriate address, enter the desired Subnet mask  
and click OK. Click Next to continue.  
26  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. On the Endurance Network Setup page if the Update Network Con-  
nections adapter names box is checked, when you restart the system  
Network Setup will reassign the adapter names. Click Apply.  
6. When the Endurance Network Setup Settings Applied page appears  
click Exit.  
7. Click Yes to restart the CoServer.  
8. When the system restarts the Endurance Network Setup wizard starts  
automatically to complete network configuration. On Windows 2003,  
Hardware Installation pop-ups may appear. Click Continue Anyway.  
9. If the video quality pop-up message appears, choose the desired  
response.  
10. The Endurance FTvirtual Server Desktop window will be displayed in  
the top left corner of the CoServer desktop with the text Endurance  
FTvirtual Server Offline.  
Marathon Technologies Corporation  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the Endurance Software  
11. The message Do you want to create a virtual disk for use as the  
FTvirtual Server boot disk? is displayed. A virtual boot disk is required  
if there is only one physical disk in the CoServer. A virtual boot disk is  
created as a way to share a single physical disk as both the CoServer  
and the FTvirtual Server Windows boot disk. Disk space is allocated to a  
file on the CoServer disk. The content of the file is then formatted, parti-  
tioned, and used as a member of the FTvirtual Server boot disk.  
If you select No, skip ahead to the CoServer 2 installation section.  
If you select Yes the Device Redirector Connections dialog is dis-  
played. Click OK, to create a Virtual boot disk.  
Create a Virtual Disk  
On the displayed Device Redirector dialog set:  
-
-
The virtual disk size. The default is 4 gigabytes.  
The boot partition size. Specify a size less than or equal to the  
virtual disk size. The default size is the virtual disk size.  
-
-
A drive letter to use when you mount the virtual disk on  
CoServer 1. The default is the next available drive letter.  
Location on CoServer 1 of the file that becomes the virtual disk.  
28  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Click Create to create the virtual disk.  
This may take a few minutes, depending on the size of the virtual disk.  
When the virtual disk is created, the Device Redirector displays a dialog  
showing the name of the file that was created, the SCSI ID of the newly cre-  
ated virtual disk, and the drive letter associated with the NTFS-formatted  
boot partition.  
Click OK.  
12. Continue with CoServer 2 Installation.  
CoServer 2 Installation  
Press both media device select buttons on the front panel of the Blade you  
have choosen for CoServer2 to assign connection of the console display  
and CDROM to that server.  
Marathon Technologies Corporation  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the Endurance Software  
1. Browse the CD and double-click setup.exe.  
2. From the Installation Launcher, select Install CoServer. Follow the  
prompts as you did during CoServer 1 installation to set the license num-  
ber, select features, choose CoServer 2 install, and define the installa-  
tion location. When the Endurance Network wizard runs proceed to step  
3 below.  
3. On the Configure Redirected page, enter 1 in the Specify total num-  
ber of Redirected adapters, and highlight the adapter you wish to  
assign as Redirected in the Connection column. Select the adapter  
based upon the PCI location-to-switchbay mapping you established dur-  
ing planning and preparation.  
4. On the Configure CoServer Link1 page, highlight the adapter you wish  
to assign as CoServer Link1 in the Connection column. Select the  
adapter based upon the PCI location-to-switchbay mapping you estab-  
lished during planning and preparation. You can use Table 2 to assign IP  
addresses for internal CLink connections.  
TABLE 2. Suggested CoServer2 CLink IP Address  
Blade Pair 1  
Blade Pair 2  
Blade Pair 3  
CoServer1  
CoServer2  
CoServer1  
CoServer2  
CoServer1  
CoServer2  
192.168.3.1  
192.168.3.2  
192.168.13.1  
192.168.13.2  
192.168.23.1  
192.168.23.2  
CSLink1  
CSLink2  
192.168.4.1  
192.168.4.2  
192.168.14.1  
192.168.14.2  
192.168.24.1  
192.168.24.2  
Note: When installing multiple blade pairs, the first blade pair has the  
same IP for both the default IP and the currently configured IP.  
This will not be the case for subsequent blade pairs.  
Right click on the adapter selection and choose Internet Protocol Prop-  
erties from the action menu. On the Internet Protocol Properties page  
select Use the following IP address and fill-in the appropriate address.  
Then, enter Subnet mask 255.255.255.0 and click OK.  
30  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
On the Endurance Network Setup page make sure that the desired  
adapter is still highlighted and select Use currently configured IP  
addressing. Click Next to continue.  
5. If your network configuration will not use CoServer Link 2, select No  
Coserver Link 2 and then click Next without selecting an adapter.  
If you will be using CoServer Link 2, then on the Configure CoServer  
Link2 page, highlight the adapter you wish to assign as CoServer Link2  
in the Connection column. Select the adapter based upon the PCI loca-  
tion-to-switchbay mapping you established during planning and prepara-  
tion.  
Right click on the selection and choose Internet Protocol Properties  
from the action menu. On the Internet Protocol Properties page select  
Use the following IP address, fill-in the appropriate address, enter  
Subnet mask 255.255.255.0 and click OK.  
On the Endurance Network Setup page make sure that the desired  
adapter is still highlighted and select Use currently configured IP  
addressing. Click Next to continue.  
6. If your network will not use a CoServer Management connection, push  
Next without highlighting an adapter  
If you will be using CoServer Management, then on the Configure CoS-  
erver Management page, highlight the adapter you wish to assign for  
CoServer Management in the Connection column. Select the adapter  
based upon the PCI location-to-switchbay mapping you established dur-  
ing planning and preparation.  
If you wish to assign an IP address, right click on the selection and  
choose Internet Protocol Properties from the action menu. On the  
Internet Protocol Properties page select Use the following IP  
address, fill-in the appropriate address, enter the desired Subnet mask  
and click OK. Click Next to continue.  
7. On the Endurance Network Setup page if the Update Network Con-  
nections adapter names box is checked, when you restart the system  
Network Setup will reassign the adapter names. Click Apply.  
8. Click Exit.  
Marathon Technologies Corporation  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the Endurance Software  
9. Click Yes to restart the CoServer.  
10. When the system restarts the Endurance Network Setup wizard starts  
automatically to complete network configuration. On Windows 2003,  
Hardware Installation pop-ups may appear. Click Continue Anyway.  
11. If the video quality pop-up message appears, choose the desired  
response.  
12. The Endurance FTvirtual Server Desktop window will be displayed in  
the top left corner of the CoServer desktop with the text Endurance  
FTvirtual Server Offline.  
13. The message Do you want to create a virtual disk for use as the  
FTvirtual Server boot disk? is displayed. You should select the same  
response that was given during CoServer 1 installation by clicking the  
approriate button.  
If you select No, the installation will continue with installing Windows and  
configuring FTvirtual Server. Skip ahead to the Installing Windows on  
and Configuring the FTvirtual Server section.  
If you select Yes the Device Redirector Connections dialog is dis-  
played.  
Click OK if both CoServer names are displayed.  
If both CoServer names are not displayed:  
-
-
-
Launch the Endurance Manager:  
Start Programs Marathon Endurance Manager)  
When both CoServers appear bright green in the CoServer  
View (View CoServer View) showing that they are in the  
Degraded state, enter the name of the missing CoServer in the  
Device Redirector Connections dialogue box; and then click  
OK.  
32  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Create a Virtual Disk  
On the displayed Device Redirector dialog set:  
-
-
The virtual disk size. The default is 4 gigabytes.  
The boot partition size. Specify a size less than or equal to the  
virtual disk size. The default size is the virtual disk size.  
-
-
A drive letter to use when you mount the virtual disk on  
CoServer 2. The default is the next available drive letter.  
Location on CoServer 2 of the file that becomes the virtual disk.  
Click Create to create the virtual disk.  
Marathon Technologies Corporation  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the Endurance Software  
This may take a few minutes, depending on the size of the virtual disk.  
When the virtual disk is created, the Device Redirector displays a dialog  
showing the name of the file that was created, the SCSI ID of the newly cre-  
ated virtual disk, and the drive letter associated with the NTFS-formatted  
boot partition. Record this drive letter for later use during the FTvirtual  
Server installation.  
Click OK.  
The Device Redirector prompts you to prepare the FTvirtual Server disk for  
the FTvirtual Server part of the installation. Click Yes in response to the Do  
you want to configure the FTvirtual Server boot disk now? prompt.  
Proceed to step 3 of the next section to configure the FTvirtual  
Server boot disk.  
Installing Windows on and Configuring the FTvir-  
tual Server  
Select CoServer Devices for FTvirtual Server Use and Configure  
the FTvirtual Server Disk  
1. If the Device Redirector Connection dialog box is displayed, click OK if  
both CoServer names appear.  
If both CoServer names do not appear:  
Launch the Endurance Manager (Start  
Programs Marathon  
Endurance Manager).  
When both CoServers appear bright green in the CoServer View  
(View CoServer View) indicating that they are in a Degraded  
state, enter the name of the missing CoServer in the Device Redi-  
rector Connection dialog box; and then click OK.  
2. The Device Redirector prompts you to prepare the FTvirtual Server disk  
for the FTvirtual Server part of the installation. Click Yes in response to  
the Do you want to configure the FTvirtual Server boot disk now?  
prompt.  
34  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3. Configure the FTvirtual Server boot disk by selecting a set of disks, one  
from each CoServer, and click OK.  
4. A warning message is displayed if the sizes of the disks are not equal.  
The FTvirtual Server software has to be installed on the CoServer that  
contains the smaller disk.  
Click Yes to continue the installation. The excess disk space on the  
larger disk will not be utilized.  
Click No if you did not intend to have mismatched drive sizes, and return  
to step 3.  
Marathon Technologies Corporation  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the Endurance Software  
5. If your CoServer has any other disk drives that you want to redirect to  
the FTvirtual Server, right click on Disk Drives, and then select Add.  
Select a set of disks, one disk from each CoServer, and click OK. The  
Device Redirector checks the sizes of the disks you selected. A warning  
message is displayed if the sizes of the disks are not equal.  
Click Yes to continue the installation.  
Click No if you did not intend to have mismatched drive sizes, and repeat  
step 5.  
Repeat this step for each FTvirtual Server disk drive that you wish to redi-  
rect.  
The Endurance Device Redirector runs on CoServer 2, and the redirected  
network adapters have been automatically configured.  
Note: You cannot redirect the CDROM on the IBM eServer  
BladeCenter because the CDROM is shared across all blades  
and controlled by a built in USB switch.Install Windows on and  
configure the FTvirtual Server Boot disk following the prompts.  
6. From the File menu select Write Device Settings, and then OK on the  
Device Settings Saved window.  
7. Exit the Endurance Device Redirector.  
8. Click Yes in response to the prompt Do you want to install the FTvir-  
tual Server now?  
36  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Install Wizard for Endurance Windows Preparation will be dis-  
played.  
Marathon Technologies Corporation  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the Endurance Software  
Install Windows on the FTvirtual Server Disk  
1. Follow the prompts through the Welcome, License Agreement, and  
Information dialogs, to the Customer Information dialog. Type a user  
name and company name and then click Next.  
2. On the Windows Installation window:  
Type the information requested including the Destination drive  
which is the FTvirtual Server boot drive. You should specify the  
drive letter that you recorded when formatting and partitioning the  
physical FTvirtual Server boot drive or when you created the FTvir-  
tual Server boot disk.  
Select Install SNMP if you want to run the Endurance SNMP  
Extension Agent to export management information through  
SNMP.  
Click NEXT.  
3. Verify the information on the Check Setup Information window and  
click NEXT.  
4. Remove the Endurance CD.  
5. You are prompted for the Windows distribution media, either the Win-  
dows CD or the location of the Windows files.  
If the Windows distribution media is on a CD, insert the Windows CD.  
If a Windows auto-play page appears, select Take no action and click  
OK.  
If a Windows installation dialogue appears, exit it.  
6. Browse to the appropriate \i386 folder. Select the folder and click OK.  
Select the same Windows release with the appropriate slip streamed  
Service Pack as is installed on the CoServers.  
38  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7. A progress bar shows the files being copied to the FTvirtual Server boot  
drive. This may take several minutes. When the installation completes,  
remove the Windows CD if it is in the drive.  
8. Click Yes in response to the prompt, Both CoServers must be reboo-  
ted. Proceed?.  
Finish the Windows Installation  
1. To monitor the installation, after the CoServers reboot, log in as Adminis-  
trator on either CoServer.  
The FTvirtual Server Desktop appears.  
2. Allow the installation to progress.  
Ensure that the Endurance taskbar icon appears.  
Text mode setup starts and displays a progress bar showing Win-  
dows being installed on the FTvirtual Server. Text mode setup com-  
pletes, and the FTvirtual Server restarts.  
GUI mode setup starts and displays the standard Windows installa-  
tion on the FTvirtual Server Desktop. GUI mode setup completes,  
and the FTvirtual Server restarts.  
If the installation prompts you, enter the requested information.  
Marathon Technologies Corporation  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the Endurance Software  
Install the Endurance FTvirtual Server Software  
The Endurance FTvirtual Server installation starts.  
1. Follow the prompts through the Welcome, License Agreement, and  
Information dialogs to the Select Features window.  
2. In the Select Features window, choose the components you want.  
Select Basic Product, the default.  
If you selected SNMP when you installed Windows on the FTvirtual  
Server, the SNMP Agent box is checked.  
Click Next.  
If the SNMP Service in Use window appears, click Yes.  
Specify the Location of the Software  
1. On the Choose Destination Location window, save the files in the  
default location C:\Program Files\Marathon\Endurance or  
specify another location.  
2. On the Confirm New Folder window, click Yes.  
3. Verify the information on the Check Setup Information window and  
then click Next.  
40  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Finish the FTvirtual Server Installation  
1. The Endurance Network Setup wizard starts and configures the FTvir-  
tual Server network adapters. Click Exit.  
On Windows 2003 Service Pack 1, a Windows Security Alert may  
appear indicating that the Windows Firewall has blocked some features  
of the Endurance Taskbar Notification Icon. Click Unblock on this dia-  
logue to allow operation of the taskbar icon. Also on Windows 2003 Ser-  
vice Pack 1, a Windows Security dialog may appear. Ignore this window  
at this time, it will be displayed again by Windows after the next reboot.  
The pop-up message The FTvirtual Server must be restarted to com-  
plete the installation. is displayed. Click Yes in response to the Restart  
Now? prompt, and the FTvirtual Server is restarted.  
2. After the FTvirtual Server restarts, login using the FTvirtual Server desk-  
top.  
On Windows 2003, if the Manage Your Server window appears, click  
Don’t display this page at logon, and then dismiss the window.  
On Windows 2000, if the Configure Your Server window appears, click  
I will configure this server later, and then dismiss the window.  
Optionally, set the FTvirtual Server resolution to 1024x768.  
On the FTvirtual Server desktop, right click and select Properties  
Settings  
Advanced. Click the Adapter tab and then List All Modes.  
Select the resolution.  
Marathon Technologies Corporation  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the Endurance Software  
3. Optionally, set the FTvirtual Server Desktop to Full Screen Mode, click  
on the title bar of the FTvirtual Server Desktop, and select the option Full  
Screen Mode.  
To shift the input focus between the CoServer and the FTvirtual Server,  
press the default hot key sequence: Ctrl/Shift/F12.  
At any time that you are running the FTvirtual Server, you can check  
whether your input is directed to the CoServer or the FTvirtual Server  
Desktop. If the Scroll Lock indicator on your keyboard is blinking, the  
focus is the CoServer. If it is not blinking, the focus is the FTvirtual  
Server Desktop.  
Verifying the FTvirtual Server Installation  
Verify the installation of the Endurance FTvirtual Server:  
1. From the FTvirtual Server Desktop, launch the Endurance Manager.  
The Endurance Manager starts in the FTvirtual Server view.  
2. From the menu bar of the Endurance Manager, select View  
CoS-  
erver View.  
The CoServer View shown on the following page displays the two CoS-  
ervers with a yellow arrow between the two disks, illustrating that data on  
one CoServer are being copied to the other CoServer. When the copying  
process is completed, the arrow disappears, the installation is complete,  
and the components appear green.  
42  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
What to do Next  
The Endurance software installation for this set of CoServers and setup of  
the FTvirtual Server is now complete. If you have additional blade pairs to  
setup return to the Installing Windows on the CoServer section at the begin-  
ning of this chapter.  
For more information about using the FTvirtual Server, read Getting Started  
with Endurance FTvirtual Server and the Endurance FTvirtual Server  
Administrator’s Guide.  
Marathon Technologies Corporation  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the Endurance Software  
44  
Marathon Technologies Corporation  
Download from Www.Somanuals.com. All Manuals Search And Download.  

La Crosse Technology Portable Radio WS 7090U User Manual
La Crosse Technology Weather Radio c86371 User Manual
Laser Computer Accessories SPK S10 User Manual
Lathem Time Clock 6000E User Manual
Learning Resources Games LER 0341 User Manual
LST Network Card MEA244 1 User Manual
Magic Chef Fryer MCSDF12W User Manual
Maxim Lawn Mower M3011BE User Manual
Memorex Stereo System MX3710 User Manual
Microsoft Server Windows NT 40 User Manual