READ BEFORE OPERATING EQUIPMENT  
This product was designed and manufactured to meet strict  
12. Grounding or Polarization — The precautions that should  
be taken so that the grounding or polarization means of an  
appliance is not defeated.  
quality and safety standards. There are, however, some in-  
stallation and operation precautions which you should be par-  
ticularly aware of.  
1. Read Instructions — All the safety and operating instruc-  
tions should be read before the appliance is operated.  
2. Retain Instructions — The safety and operating instruc-  
tions should be retained for future reference.  
AC POLARIZED PLUG  
3. Heed Warnings — All warnings on the appliance and in  
the operating instructions should be adhered to.  
13. Power-Cord Protection — Power-supply cords should be  
routed so that they are not likely to be walked on or  
pinched by items placed upon or against them, paying par-  
ticular attention to cords at plugs, convenience recep-  
tacles, and the point where they exit from the appliance.  
4. Follow Instructions — All operating and use instructions  
should be followed.  
5. Water and Moisture — The appliance should not be used  
near water — for example, near a bathtub, wash-bowl,  
kitchen sink, laundry tub, in a wet basement, or near a  
swimming pool, etc.  
14. Cleaning — The appliance should be cleaned only as rec-  
ommended by the manufacturer.  
15. Power Lines— An outdoor antenna should be located  
away from power lines.  
6. Carts and Stands — The appliance should be used only  
with a cart or stand that is recommended by the manufac-  
turer.  
16. Outdoor Antenna Grounding — If an outside antenna is  
connected to the receiver, be sure the antenna system is  
grounded so as to provide some protection against volt-  
age surges and built up static charges. Section 810 of the  
National Electrical Code, ANSI/NFPA No. 70-1984, pro-  
vides information with respect to proper grounding of the  
mast and supporting structure, grounding of the lead-in  
wire to an antenna discharge unit, size of grounding con-  
ductors, location of antenna-discharge unit, connection to  
grounding electrodes, and requirements for the grounding  
electrode. See Fig. 1.  
7. An appliance and cart combination should be moved with  
care. Quick stops, excessive force, and uneven surfaces  
may cause the appliance and cart combination to over-  
turn.  
17. Nonuse Periods — The power cord of the appliance  
should be unplugged from the outlet when left unused for  
a long period of time.  
8. Wall or Ceiling Mounting — The appliance should be  
mounted to a wall or ceiling only as recommended by the  
manufacturer.  
18. Object and Liquid Entry — Care should be taken so that  
objects do not fall and liquids are not spilled into the enclo-  
sure through openings.  
9. Ventilation — The appliance should be situated so that its  
location or position does not interfere with its proper ven-  
tilation. For example, the appliance should not be situ-  
ated on a bed, sofa, rug, or similar surface that may block  
the ventilation openings; or, placed in a built-in installa-  
tion, such as a bookcase or cabinet that may impede the  
flow of air through the ventilation openings.  
19. Damage Requiring Service — The appliance should be  
serviced by qualified service personnel when:  
A. The power-supply cord or the plug has been damaged;  
or  
B. Objects have fallen, or liquid has spilled into the appli-  
ance; or  
C. The appliance has been exposed to rain; or  
10. Heat — The appliance should be situated away from heat  
sources such as radiators, heat registers, stoves, or  
other appliances (including amplifiers) that produce  
heat.  
D. The appliance does not appear to operate normally or  
exhibits a marked change in performance; or  
E. The appliance has been dropped, or the enclosure  
damaged.  
11. Power Sources — The appliance should be connected to  
a power supply only of the type described in the operating  
instructions or as marked on the appliance.  
20. Servicing — The user should not attempt to service the  
appliance beyond that described in the operating instruc-  
tions. All other servicing should be referred to qualified  
service personnel.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIG. 1  
EXAMPLE OF ANTENNA GROUNDING ACCORDING TO  
NATIONAL ELECTRICAL CODE INSTRUCTIONS  
CONTAINED IN ARTICLE 810 - “RADIO AND TELEVISION EQUIPMENT”  
ANTENNA  
LEAD IN  
WIRE  
GROUND  
CLAMP  
ANTENNA  
DISCHARGE UNIT  
(NEC SECTION 81020)  
ELECTRIC  
SERVICE  
EQUIPMENT  
GROUNDING CONDUCTORS  
(NEC SECTION 81021)  
GROUND CLAMPS  
POWER SERVICE GROUNDING  
ELECTRODE SYSTEM  
(NEC ART 250, PART H)  
NEC NATIONAL ELECTRICAL CODE  
This Class B digital apparatus meets all requirements of the  
Cet appareil numérique de la Classe B respecte toutes les  
Canadian Interference - Cansing Equipment Regulations.  
exigences du Règlement sur le matériel brouilleur du Canada.  
NOTE TO CATV SYSTEM INSTALLER:  
This reminder is provided to call the CATV system installers attention to Article 82040 of the NEC that  
provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected  
to the grounding system of the building, as close to the point of cable entry as practical.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dolby noise reduction and HX Pro headroom extension are manufactured under license from Dolby Laboratories  
Licensing Corporation. HX Pro originated by Bang & Olufsen.  
“DOLBY” the double-D symbol and “HX PRO” are trademarks of Dolby Laboratories Licensing Corporation.  
is a registered trademark.  
Printed in Japan  
98 / 10 MIT  
418S851252  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
Page  
INTRODUCTION............................................................................................................................................................. 6  
PRECAUTIONS .............................................................................................................................................................. 6  
FEATURES ..................................................................................................................................................................... 6  
REAR PANEL CONNECTIONS ...................................................................................................................................... 7  
FRONT PANEL FEATURES ........................................................................................................................................... 7  
DISPLAYS ....................................................................................................................................................................... 9  
OPERATION ................................................................................................................................................................. 10  
PLAYBACK ............................................................................................................................................................... 10  
PLAYBACK ON ONE WELL (Same procedure for Well A or Well B) OR BOTH WELLS .................................... 10  
CONTINUOUS PLAYBACK ................................................................................................................................. 10  
TIMER PLAYBACK (Same procedure for Wells A and B) .................................................................................... 10  
RECORDING............................................................................................................................................................ 10  
SINGLE WELL RECORDING (Same procedure for Well A or Well B) ................................................................ 10  
CONTINUOUS RECORDING ...............................................................................................................................11  
PARALLEL RECORDING .....................................................................................................................................11  
TIMER RECORDING (Same procedure for Wells A and B) .................................................................................11  
OVERLAP SERIES RECORDING ........................................................................................................................11  
CASCADE OPERATION .......................................................................................................................................... 12  
CASCADE CONTINUOUS PLAYBACK ............................................................................................................... 12  
CASCADE CONTINUOUS RECORDING ........................................................................................................... 12  
SYNCHRONOUS RECORDING .............................................................................................................................. 12  
CASCADE OVERLAP SERIES RECORDING ......................................................................................................... 12  
OTHER OPERATIONS............................................................................................................................................. 13  
ERASURE OF TAPE............................................................................................................................................ 13  
AUTO TAPE SELECTOR..................................................................................................................................... 13  
AUTOMATIC BIAS ADJUST ................................................................................................................................ 13  
TAPE STOP ALARM ............................................................................................................................................ 13  
AUTO COUNTER RESET ................................................................................................................................... 13  
TO PROTECT VALUABLE RECORDINGS ......................................................................................................... 13  
ENHANCED REMOTE CONTROL OPERATIONS .................................................................................................. 13  
SIMULTANEOUS (PARALLEL) RECORDING ..................................................................................................... 13  
DUPLICATION SYNCHRONIZATION ...................................................................................................................... 14  
CONNECTION ..................................................................................................................................................... 14  
NORMAL SPEED DUPLICATION........................................................................................................................ 14  
HIGH SPEED DUPLICATION .............................................................................................................................. 14  
QMS (QUICK MUSIC SEARCH) .............................................................................................................................. 14  
AUTO BIAS & EQ SYSTEM.......................................................................................................................................... 15  
CARE AND MAINTENANCE......................................................................................................................................... 16  
MAINTENANCE ....................................................................................................................................................... 16  
HEAD CLEANING................................................................................................................................................ 16  
HEAD DEMAGNETIZATION ................................................................................................................................ 16  
CLEANING OF EQUIPMENT EXTERNAL SURFACES ...................................................................................... 16  
REPAIRS....................................................................................................................................................................... 16  
TROUBLESHOOTING .................................................................................................................................................. 16  
TECHNICAL SPECIFICATIONS ................................................................................................................................... 53  
FRONT AND REAR PANEL DRAWINGS ..................................................................................................................... 54  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
¡ CASCADE CONNECTION FOR SERIAL CONNECTION OF  
INTRODUCTION  
MULTIPLE UNITS  
By connecting several PMD520s in series by way of the cas-  
cade connection, multiple units can play or record continu-  
ously for logging and other long-time recording applications.  
In this case, Wells A and B of unit #1 will play (or record) as  
in the example above, then they will trigger the start of con-  
tinuous playback (or record) of unit #2, and so on.  
Thank you for selecting the Marantz Model PMD520 3-head In-  
dependent Dual Well Cassette Deck.  
Please read these operating instructions carefully. We recom-  
mend that you read the entire user guide before you connect or  
operate the unit.  
After you have reviewed the contents this manual, we suggest  
that you make all system connections before you attempt to  
operate the unit.  
Refer to the Figures on Pages 54 – 57 of this user guide.  
The callout numbers on the Figures correspond to those found  
in the text. All references to connections and controls are printed  
in BOLD type, as they appear on the unit.  
¡ OVERLAP SERIES RECORDING  
This feature records long events such as a conference, with-  
out interruption. The recording of the next tape starts when  
the remaining time on the previous tape is approximately 3  
minutes.  
¡ PARALLEL RECORDING (DUPLICATION)  
When multiple copies of the same source are required, it is  
possible to record both Well A and Well B simultaneously, in  
parallel, from a single source.  
PRECAUTIONS  
¡ TIMER REC/PLAY  
The following precautions should be considered when operat-  
ing the equipment.  
Time-activated playback and recording are available using  
a commercially available timer.  
When setting the equipment ensure that :  
¡ FINE SPEED CONTROL  
– air is allowed to circulate freely around the equipment  
– the equipment is on a vibration free surface  
Each Well features 3% speed control.  
¡ METERS AND LINEAR TIME TAPE COUNTERS  
– the equipment will not be exposed to interference from an  
external source  
Each Well features independent FL bargraph meters, and a  
linear time (minutes and seconds) counter. The display on  
these counters is only an approximate indication of minutes  
and seconds and its accuracy depends on the match be-  
tween the Tape and the correct TAPE TIME setting.  
– the equipment will not be exposed to excessive heat, cold,  
moisture or dust  
– the equipment will not be exposed to direct sunlight  
– the equipment will not be exposed to electrostatic discharges  
¡ In addition, never place heavy objects on the equipment.  
¡ TAPE STOP ALARM  
A buzzer sound is generated to indicate the end of tape af-  
ter playback or recording.  
¡ If a foreign body or water does enter the equipment, contact  
your nearest dealer or service center.  
¡ DOLBY B/C NR SYSTEMS  
¡ Do not pull out the plug by pulling on the mains lead. Hold  
The Dolby NR (Noise Reduction) systems compress and am-  
plify signals during recording in order to raise the signal-to-  
noise ratio on the tape. During playback, these signals are  
expanded and attenuated by the same amount in order to  
regain the original dynamic range of the music. An additional  
result of this expansion and attenuation is that the noise floor  
of the recording is reduced significantly. Dolby B typically  
reduces noise by 10 dB, while Dolby C typically reduces  
noise by 20 dB.  
the plug.  
FEATURES  
¡ COMPLETELY INDIVIDUAL DUAL SYSTEM  
Well A and Well B can be controlled independently for both  
recording and playback. There are two sets of inputs and  
outputs which allow for many modes of recording and play-  
back. Two separate input sources can be recorded simulta-  
neously and independently on the two decks; two different  
tapes can be played back simultaneously on the two decks;  
and lastly, it is possible to play a cassette on one well, and  
record a different source (such as a mixer) on the other well  
simultaneously.  
¡ DOLBY HX PRO HEADROOM EXTENSION  
The Dolby HX PRO system monitors the total amount of ef-  
fective bias during recording and instantaneously compen-  
sates for any excess bias by reducing the deck’s bias signal  
level accordingly.  
The system operates independently on each channel. HX  
PRO is unlike a noise reduction system because it functions  
only during recording and no decoding is required. There-  
fore, a tape recorded with the HX PRO system can be played  
back on any other cassette deck while retaining the benefits  
of HX PRO.  
There are also several modes in which the two decks work  
together.  
¡ CONTINUOUS RECORDING AND PLAYBACK  
Dolby noise reduction and HX Pro headroom extension are  
manufactured under license from Dolby Laboratories Licens-  
ing Corporation. HX Pro originated by Bang & Olufsen.  
In the continuous mode, Well A will play (or record) side one,  
and then automatically switch to Well B, which will play (or  
record) side one. In this way 1-1/2 hours of uninterrupted  
playback or recording is possible using C-90 cassettes.  
“DOLBY” the double-D symbol and “HX PRO” are trademarks  
of Dolby Laboratories Licensing Corporation.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTROL I/O Pin assign  
REAR PANEL CONNECTIONS  
Pin No.  
Function  
REW A IN  
Pin No.  
14  
Function  
NORM IN  
A DECK A/B LINE INPUT  
1
2
These jacks should be connected to LINE OUTPUT of your  
source.  
REW B IN  
15  
HIGH IN  
3
FF A IN  
16  
AUTO REW IN  
TAPE TIME A IN  
TAPE TIME B IN  
COUNTER RESET A IN  
COUNTER RESET B IN  
AUTO BIAS A IN  
AUTO BIAS B IN  
HIGH OUTPUT  
GND  
4
FF B IN  
17  
Note:  
5
PLAY A IN  
PLAY B IN  
STOP A IN  
STOP B IN  
REC A IN  
18  
Short pins are installed from the factory in the Deck B IN-  
PUT.  
The short pins should be removed only if an input source is  
connected directly to Deck B. They have been installed to  
avoid crosstalk from one deck to the other, in case one deck  
is recording and the other deck is playing back.  
6
19  
7
20  
8
21  
9
22  
10  
11  
12  
13  
REC B IN  
23  
REC MUTE A IN  
REC MUTE B IN  
A+B REC IN  
24  
25  
A+B OUTPUT  
B DECK A/B LINE OUTPUT  
These jacks should be connected to the LINE INPUT of your  
PA or monitoring system.  
¡ All input is active low.  
¡ All output is open collector.  
C LOOP THROUGH A OUTPUT  
These jacks output the same signal input to the LINE INPUT  
jacks of Well A as they are input.  
I AC POWER INPUT  
Connect one end of the power cord to this receptacle.  
D INPUT SELECT SWITCH  
This switch selects the input mode for the LINE INPUT jacks.  
¡ Position A, B : Deck A receives its input from LINE A.  
Deck B receives its input from LINE B.  
¡ Position A  
: Both decks receive the same input from  
LINE INPUT A.  
FRONT PANEL FEATURES  
q POWER SWITCH  
E RC-5 REMOTE CONTROL JACKS  
For switching the unit on and off.  
These jacks are for use with the remote control accessories.  
Connect the output of an RC-5 based remote control to the  
RC-5 input of the PMD520. The RC-5 output of the PMD520  
may be connected to the RC-5 input of other machines for  
multiple-machine control from the same remote control ac-  
cessory.  
w CASSETTE HOLDER A/B  
Insert cassettes into these holders with the exposed tape  
facing downward.  
Refer to the specifications for the complete RC-5 command  
set.  
e CONTROL BUTTONS  
F EXT (EXTENSION) REMOTE CONTROL JACKS  
This jack is used to cascade several PMD520s for continu-  
ous serial recording and playback.  
Connect the EXT OUT jack to the EXT IN jack of the next unit  
in the chain.  
STOP  
Press this button to cancel any operation modes and to stop  
tape travel.  
PLAY  
Press this button to start playback.  
G MPX FILTER SWICH  
FAST WIND  
When recording FM broadcasts, set this switch to ON.  
Press these buttons to fast wind in the direction of the ar-  
rows. If the Well is in play mode, these buttons will place the  
well in CUE/REVIEW Mode. In CUE/REVIEW mode, if these  
buttons are pressed the Well will enter the fast wind mode.  
H PARALLEL CONTROL I/O  
These terminals contain a control signal input for almost all  
of the operations of the unit and output the A+B and HIGH  
signals.  
REC  
The application range of this unit can be expanded greatly  
by using these terminals properly.  
Press this button to enter the REC-PAUSE mode. Press PLAY  
to initiate recording. Press this button again to re-enter the  
REC-PAUSE mode.  
13 12 11 10  
9
8
7
6
5
4
3
2
1
REC MUTE  
25 24 23 22 21 20 19 18 17 16 15 14  
When in REC-PAUSE mode, press this button to record 3  
seconds of no sound.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
r COUNTER BUTTONS  
i TAPE SPEED BUTTONS  
These switches determine the playback/recording speed of  
tapes in both Wells A and B.  
¡ TAPE TIME  
This button changes the reference time of tape (tape type)  
so that the time counter can show accurate time informa-  
tion. The initial setting when the unit is turned on is "60".  
The first press of this button displays the current setting.  
Every time this button is pressed while the time setting is  
displayed, it is changed in a cyclic order of 60 90 120  
10 20 30 46 60...  
¡ HIGH  
Press this button to set the tape speed for duplication to  
3-6/8 ips (9.5 cm/sec).  
The HIGH indicator lights when HIGH is selected.  
When HIGH is selected, Dolby NR is disabled.  
¡ NORM  
¡ RESET  
Press this button to set the tape speed for duplication to  
1-7/8 ips (4.75 cm/sec).  
The NORM indicator lights up when NORM is selected.  
Pressing this button will reset the counter time to 00.00 (0  
minutes, 0 seconds).  
t AUTO REW (AUTO REWIND) BUTTON  
o OVERLAP REC (OVERLAP RECORD) BUTTON  
Used to switch the auto rewind mode ON or OFF.  
The indicator lights up when the auto rewind mode is on.  
When the auto rewind mode is on, each well enters rewind  
mode upon detection of the end of tape.  
The auto rewind mode is switched on or off simultaneously  
for both Wells A and B.  
Pressing the OVERLAP REC button when the continuous  
mode is "  
" or "  
" switches the overlap series recording  
mode alternately to Off On Off. The OVERLAP REC  
indicator lights up when the overlap series recording mode  
is on.  
The operation in the overlap series recording mode is vari-  
able depending on the current continuous mode.  
The initial setting is off.  
y CONT (CONTINUOUS) BUTTON  
0
0
0
!
0
MONITOR BUTTONS  
0
Used to switch the continuous mode ON or OFF.  
Pressing this button switches the monitoring mode between  
Tape and Source.  
The MONITOR indicator lights up when monitoring from the  
tape, and is off when monitoring from the input source.  
The initial setting when the unit is turned on is tape monitor.  
Every time this button is pressed, the CONT indicator status  
changes in cycle of On Blinking Off On...  
The lighting of the indicator indicates that the continuous  
mode of PMD520 is "  
The blinking of the indicator indicates that its continuous  
mode is " ". (A B A B A ...)  
The initial setting when the unit is turned on is off.  
Pressing the PLAY or REC button while the continu-  
". (A B C D E ...)  
1
1
1
!
1
2
BIAS RESET BUTTONS  
1
Used to reset the bias setting to the factory setting.  
The indicator is off when the factory-set bias setting is used.  
The indicator will light up after the Auto Bias program is run.  
ous mode is on starts continuous playback or continuous  
recording.  
u A+B REC BUTTON  
2
2
2
!
DOLBY NR B/C SELECTORS  
2
Check to insure that both wells are in STOP mode prior to  
pressing the A+B REC button.  
This switch is used to select Dolby B or C noise reduction  
for recording or playback.  
Most commercially available cassettes which display the  
double-D symbol are encoded with Dolby B noise reduc-  
tion.  
Pressing the A+B REC button once will cause both wells to  
enter a REC-PAUSE mode to adjust recording levels. Press-  
ing the A+B REC button a second time, will cause both wells  
to enter a REC mode simultaneously. Pressing the A+B REC  
button a third time, will cause both wells to enter a REC-  
PAUSE mode again and pressing the A+B REC button a  
fourth time , will resume the REC mode.  
Note:  
When the TAPE SPEED is set to HIGH, the Dolby NR is  
switched off regardless of the position of the selectors.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
3
3
3
!
3
TIMER  
DISPLAYS  
This switch is used to set the timer operation mode.  
a TAPE TIME COUNTERS  
¡ OFF  
No timer operation is used when the switch is set to this  
position.  
These counters display the tape position for each Well in  
Minutes and Seconds.  
¡ REC  
Timer recording operation is activated when the switch is  
set to this position. The tape will automatically start record-  
ing when the power is switched on.  
b BARGRAPH LEVEL METERS  
These meters display the signal levels for each Well in ste-  
reo.  
¡ PLAY  
Timer playback operation is activated when the switch is  
set to this position. The tape will automatically start playing  
when the power is switched on.  
c AUTO REW INDICATOR  
These indicators will light up when the AUTO REW mode  
button t is pressed.  
4
4
4
!
4
5
REC LEVEL CONTROL  
4
For adjusting the record input level.  
d CONT (CONTINUOUS) INDICATORS  
These indicators will light up when the CONT mode button  
5
5
5
5
!
REC BALANCE CONTROL  
y is pressed.  
Used to adjust the left-right balance of channels while re-  
cording.  
e A+B INDICATOR  
These indicators will light up when the A+B mode button u  
6
6
6
!
6
7
FINE SPEED  
6
is pressed.  
Each well features 3% speed control.  
f TAPE SPEED INDICATORS  
7
7
7
7
!
PHONES SELECTOR SWITCH  
¡ HIGH SPEED INDICATOR  
This indicator will light up when the HIGH SPEED mode  
button i is pressed.  
This switch allows you to select Well A, Well B, or a mix of  
both Wells (A+B) in the phones.  
¡ NORMAL SPEED INDICATOR  
This indicator will light up when the NORMAL SPEED mode  
button i is pressed.  
8
8
8
!
8
9
PHONES LEVEL CONTROL  
8
This control adjusts the volume of the headphone output.  
g OVERLAP RECORDING INDICATOR  
9
9
9
!
PHONES JACK  
9
This indicator will light up when the OVERLAP REC mode  
button o is pressed.  
Use this jack to connect a pair of headphones with a stereo  
1/4" connector.  
h MONITOR INDICATORS  
These indicators will light up when in the TAPE MONITOR  
mode.  
i BIAS RESET INDICATORS  
These indicators will light up after the BIAS RESET program  
is run.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
RECORDING  
OPERATION  
SINGLE WELL RECORDING  
(Same procedure for Well A or Well B)  
PLAYBACK  
PLAYBACK ON ONE WELL (Same procedure for Well  
A or Well B) OR BOTH WELLS  
1. Insert a blank cassette into the cassette holder(s).  
2. Reset the tape counter by pressing the RESET button.  
1. Set the POWER button to ON.  
3. If you wish to use Dolby NR, set the DOLBY NR switches  
2. Insert a prerecorded cassette in the cassette holder(s).  
3. Reset the tape counter by pressing the RESET button.  
accordingly.  
4. Press the REC  
button to enter REC-PAUSE mode.  
4. If the tape has been encoded with Dolby NR, set the DOLBY  
5. Adjust the record level using the REC LEVEL control, so that  
NR switches accordingly.  
the red LEDs light only at peaks in the music.  
5. Press the PLAY  
button to play the cassette.  
button to stop playback.  
6. Press the PLAY  
button to initiate RECORD.  
6. Press the STOP  
7. Press the STOP  
button to end recording, or press REC  
again to re-enter REC-PAUSE mode.  
Note:  
CONTINUOUS PLAYBACK  
Be aware of the setting of the input select switch on the rear  
panel.  
1. Set the POWER button to ON.  
2. Insert recorded cassettes into both Wells.  
¡ A, B Position : Well A receives input from input A, Well B  
receives input from input B.  
3. If the tape has been encoded with Dolby NR, set the DOLBY  
NR switches accordingly.  
¡ A Position  
: Both wells receive input from input A.  
4. Press the CONT button to select the continuous mode. The  
lighting of the CONT indicator indicates the "  
the blinking indicates the " " mode.  
5. Press one of PLAY buttons. Playback will start. When that  
Well finishes playing , the second well will begin playing.  
6. When the continuous mode is " ", the tape stops after the  
" mode and  
Tape Types and Length  
Any type of tape (Normal, High, or Metal) can be used with the  
PMD520. High or Metal tapes have superior performance com-  
pared to Normal Tapes. The PMD520 can sense which kind of  
tape is being used, and will automatically adjust bias, EQ, etc.  
C-60 or C-90 length tapes are recommended, as C-120 tapes  
are often too thin, and can become entangled in the transport  
mechanism.  
second well is finished or triggers another deck via the EXT  
output.  
7. When the continuous mode is "  
" and the AUTO REW mode  
is on, the tape in the first well that has been rewound is played  
after the second well is finished.  
Remote Operation  
8. Press the STOP  
to stop playback.  
The period (00 . 0 0) of the time display will flash depending  
on which Well is being addressed by a conected remote con-  
trol.  
9. Press CONT to cancel CONT mode.  
Note:  
During continuous playback, the signal from both wells goes  
to line output A.  
TIMER PLAYBACK (Same procedure for Wells A and B)  
1. Connect the power cord of this unit to a timer.  
2. Insert a prerecorded cassette in the cassette holder(s).  
3. If you wish to use Dolby NR, set the DOLBY NR switches to  
select B- or C-type noise reduction.  
4. Set the POWER switch of this unit to ON.  
5. Set the TIMER switch to the PLAY position.  
6. Set the timer to the desired time.  
7. When the set time comes and the timer turns on, power is  
supplied to the unit and playback starts automatically.  
Note:  
Use a timer which can turn on at the desired time of the day.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TIMER RECORDING  
(Same procedure for Wells A and B)  
CONTINUOUS RECORDING  
1. Insert blank cassettes into both Wells. Be sure that both decks  
are rewound.  
1. Connect the power cord of this unit to a timer.  
2. Insert a blank cassette in the cassette holder(s).  
3. Set the POWER button to on.  
2. If you wish to use noise reduction, set the DOLBY NR switches  
accordingly.  
3. Reset the tape counters to "00.00" by pressing the RESET  
4. If you wish to use Dolby NR in your recording, set the DOLBY  
buttons.  
NR switches to select B- or C-type noise reduction.  
4. Press the CONT button. Pressing it once sets the "  
in which the indicator lights up. Pressing it twice sets the  
" mode, in which the indicator blinks.  
" mode,  
5. Press the REC  
button to enter record-pause mode.  
6. While observing the level meter, adjust the REC LEVEL Con-  
"
trol.  
5. Press the REC  
buttons of both wells to enter REC-PAUSE  
7. Set the TIMER switch to the REC position.  
mode.  
8. Set the timer to the desired time.  
6. Adjust the record level using the REC LEVEL control.  
7. Press the PLAY button on Well A to initiate RECORD.  
8. When the tape in Well A is finished, recording starts auto-  
matically in Well B. If the continuous mode is " ", recording  
ends when tape in Well B is finished and another deck is  
triggered with the EXT output. If the continuous mode is " ",  
9. When the set time comes and the timer turns on, power is  
supplied to the unit and recording starts automatically.  
Note:  
Use a timer which can turn on at the desired time of the day.  
recording in Well A restarts at the moment recording in Well  
B is finished. At this time, the tape in Well A should be re-  
versed manually or replaced with a new tape.  
OVERLAP SERIES RECORDING  
1. Insert blank cassettes in the cassette holders of both wells.  
9. Press STOP  
button to end the Recording.  
2. Press the CONT button. Pressing it once sets the "  
in which the indicator lights up. Pressing it twice sets the  
" mode, in which the indicator blinks.  
" mode,  
10. Press the CONT button to cancel continuous mode.  
"
Note:  
All input for continuous recording will come from Line In-  
put A.  
3. Press the OVERLAP REC button. The OVERLAP REC indi-  
cator lights up to indicate the overlap series recording mode.  
4. Press the REC  
buttons of Wells A and B to enter record-  
pause mode.  
PARALLEL RECORDING  
5. In record-pause mode, adjust the REC LEVEL controls of  
both wells.  
1. Insert blank cassettes into both Wells. Be sure that both decks  
are rewound.  
6. Press the PLAY  
button of Well A or B to start recording.  
7. When the remaining time on the tape in the first Well is ap-  
proximately 3 minutes, the other well starts recording auto-  
matically.  
2. If you wish to use noise reduction, set the DOLBY NR switches  
accordingly.  
3. Reset the tape counters to 00.00by pressing the RESET  
8. If the auto rewind mode is switched on, the finished tape is  
rewound automatically to the beginning. If the auto rewind  
mode is off, reverse the finished tape manually to prepare  
for the next recording.  
buttons.  
4. Press the A+B REC button. This will set both Wells for record,  
and the REC lights will blink.  
5. Adjust the record level using the REC LEVEL control.  
9. To terminate the overlap series recording mode, press the  
6. Press the A+B button again to start the recording.  
OVERLAP REC button again.  
7. Press both STOP  
buttons to stop recording, or press the  
Note:  
A+B button to re-enter record-pause mode.  
If AUTO REW is activated during the "  
" mode or the con-  
Note:  
All input for parallel recording will come from Line Input A.  
tinuous loop is fed back to the first deck, the information re-  
corded will be erased and recorded over.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CASCADE OPERATION  
SYNCHRONOUS RECORDING  
Synchronous Recording is possible only when this unit is con-  
nected with a Marantz Professional product equipped with the  
Sync Recording function.  
Refer to Fig. 5  
CASCADE CONTINUOUS PLAYBACK  
The Synchronous Recording connection consists of a single RCA  
cable which runs to the RC-5 REMOTE input jack on the rear  
panel of the PMD520, from the REMOTE output jack on the rear  
panel of the Marantz source.  
1. Set the POWER button to ON.  
2. Connect the EXT output of the first unit into the EXT input of  
the second unit.  
Then connect the EXT output of the second deck into the  
next unit in the chain or back into the first unit.  
1. Set the POWER button to ON.  
3. Insert recorded cassettes into all wells.  
2. Insert blank cassettes into the appropriate Wells.  
4. If the tape has been encoded with Dolby NR, set the DOLBY  
3. If the tape has been encoded with Dolby NR, set the DOLBY  
NR switches accordingly.  
NR switches accordingly.  
5. Press the CONT buttons on all units. The CONT Indicator will  
4. press the REC  
button on the appropriate Wells of the unit.  
light.  
Check to see that REC-PAUSE mode is indicated.  
When recording two tapes in parallel, press the A+B button  
6. Press the PLAY  
button of Well A, of Unit #1.  
instead the REC  
5. Adjust the recording level with source playing.  
6. Press the PLAY button of the source player.  
button.  
7. When Well A of Unit #1 finishes, Well B of Unit #1 will start  
automatically.  
8. When Well B of Unit #1 finishes, Well A of Unit #2 will start  
automatically.  
9. To stop playback, press the CONT button, and STOP  
CASCADE OVERLAP SERIES RECORDING  
buttons on all units.  
Note:  
1. Connect the units as shown in Figure 6.  
Output from both Wells of each unit will be sent to LINE Out-  
put A on each unit. Line output B is not used on any unit.  
2. Insert blank cassettes in both Wells A and B of all the con-  
nected units.  
3. Press the CONT button of all the units so that their CONT  
indicator light up (the continuous mode is "  
").  
CASCADE CONTINUOUS RECORDING  
4. Press the OVERLAP REC buttons of the all the units.  
The OVERLAP REC indicators light up to indicate the over-  
lap series recording mode.  
1. Set the POWER button to ON.  
2. Connect the EXT output of the first unit into the EXT input of  
the second unit.  
5. Press the REC  
buttons of both Wells A and B of all the  
units to put all the wells in record-pause mode.  
Then connect the EXT output of the second deck into the  
next unit in the chain or back into the first unit.  
6. Adjust the REC LEVEL controls of Wells A and B in record-  
pause mode.  
3. Insert recorded cassettes into all wells.  
7. Press the PLAY  
button of Well A or B of unit #1 to start  
4. If the tape has been encoded with Dolby NR, set the DOLBY  
recording.  
NR switches accordingly.  
8. When the remaining time on the tape in the first well becomes  
about 3 minutes, the other well starts recording automati-  
cally.  
5. Press the CONT buttons on all units. The CONT Indicator will  
light.  
6. Press the REC  
buttons on both Wells of each unit. Check  
9. Similarly, when the remaining time on the tape in the second  
well of unit #1 is approximately 3 minutes, Well A of unit #2  
starts recording automatically.  
to see that every Well indicates REC-PAUSE mode.  
7. Adjust the recording level of each Well.  
8. Press the PLAY  
button on Well A of Unit #1.  
10. If the auto rewind mode is switched on, the finished tape is  
rewound automatically to the beginning. If the auto rewind  
mode is off, reverse the finished tape manually to prepare for  
the next recording.  
9. When Well A of Unit #1 finishes, Well B of Unit #1 will start  
automatically.  
10. When Well B of Unit #1 finishes, Well A of Unit #2 will start  
automatically.  
11. To terminate the overlap series recording mode, press the  
OVERLAP REC button again.  
11. To stop Recording , press the CONT button, and STOP  
buttons on all units.  
12. To terminate the continuous mode, press the CONT button  
twice.  
Note:  
Input to both Wells of each unit will be received from Line  
Input A on each unit. Line Input B is not used on any unit.  
Note:  
If AUTO REW is activated during the "  
" mode or the con-  
tinuous loop is fed back to the first deck, the information re-  
corded will be erased and recorded over.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Error Message  
OTHER OPERATIONS  
If a problem occurs during the AUTOMATIC BIAS routine,  
an Error message will appear on the display. Please refer  
to the following table.  
Caution:  
¡ If you must stop playback or recording in the middle of a tape,  
be sure to press the STOP  
button first, then turn the power  
off. If the power is turned off in the middle of an operation, the  
cassette tape remains loaded, and it may be impossible to  
eject. In such a case, turn the power on, enter PLAY mode,  
Err No.  
Err 1  
Err 2  
Err 3  
Err 4  
Err 5  
Meaning  
Tape End Error  
Internal Oscillator Error  
Bias setting Error  
REC EQ Adjust Error  
Total Adjust Error  
then press STOP  
button, and then eject the tape.  
¡ The same caution as above applies in cases of power failure.  
To prevent damage, never attempt to force the removal of a  
cassette while the power is off.  
Errors 2-5 are probably the result of a bad tape. Please rerun  
the AUTO BIAS program with a different tape.  
ERASURE OF TAPE  
When a program source is recorded onto a tape, the previously  
recorded sound is erased automatically, and replaced with the  
new recording. If you wish to erase a tape without recording,  
set the REC LEVEL control to the minimum (0) position or re-  
move the input source, and let the tape travel in the REC mode.  
TAPE STOP ALARM  
When either Well A or B reaches the end of a tape, the PMD520  
generates a buzzer sound to indicate it.  
AUTO TAPE SELECTOR  
AUTO COUNTER RESET  
This unit is equipped with auto tape selector which automati-  
cally sets the bias and equalizer level using the detection holes  
provided in the cassette shell. The bias and equalizer level is  
automatically set according to the type of cassette as follows.  
(See Figure 7)  
When a cassette is removed from a cassette holder and an-  
other tape is inserted, the tape counter is reset automatically to  
"00:00".  
¡ Normal tapes  
¡ High tapes  
¡ Metal tapes  
EQ ; 120 µS , Bias ; Low  
EQ ; 70 µS , Bias ; High  
EQ ; 70 µS , Bias ; Metal  
TO PROTECT VALUABLE RECORDINGS  
In the record mode, information previously recorded on the tape  
will automatically be erased. To prevent this from happening,  
use a small screwdriver to break out one or both safety tabs  
(See Figure 8). It is possible to restore the recording capability  
of either side of the cassette by covering the opening with clear  
adhesive tape (See Figure 9).  
AUTOMATIC BIAS ADJUST  
With this feature, the microcomputer built into the PMD520 ad-  
justs the bias and record gain automatically so that the charac-  
teristics of the tape in use can be exhibited fully. (Refer to page  
15 for more information)  
1. Insert the cassette in the cassette holder of the well to be  
subjected to bias setting.  
ENHANCED REMOTE CONTROL OPERATIONS  
SIMULTANEOUS (PARALLEL) RECORDING  
2. While holding down the REC  
button Press the REC MUTE  
button.  
Check to insure that both wells are in REC PAUSE mode after  
pressing the A+B REC button on the front of the unit. The unit  
will start recording when either a PLAY or A+B command from  
the remote controller has been received. During the REC mode,  
the unit can be placed into a REC PAUSE mode by sending a  
PAUSE, A+B, or REC command from the remote controller and  
started again by a PLAY or A+B command from the remote  
3. Ab will appear on the display followed by a number that will  
count down until the adjustment is complete.  
4. If an Error occurs during this process, please refer to the  
next section.  
5. When the bias has been set, the BIAS RESET indicator lights  
up.  
controller. Pressing the STOP  
button on the front of the unit  
6. To reset the bias to the factory setting, press the BIAS RE-  
SET button. The indicator is extinguished and the factory-  
set bias is recalled.  
or sending a STOP command from the remote controller will  
cancel this operation.  
7. To return to the set bias, press the BIAS RESET button so the  
indicator lights up.  
8. To change the bias setting, start the adjustment from the be-  
ginning.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HIGH SPEED DUPLICATION  
DUPLICATION SYNCHRONIZATION  
1. Insert the master tape in Well A of unit #1.  
Refer to Fig. 6  
CONNECTION  
2. Insert the blank cassettes in both Wells A and B of units #2  
and after.  
1. Connect the WRC220 * to the RC-5 IN jack of unit #1.  
3. Press the TAPE SPEED HIGH buttons of all the units so that  
2. Connect the RC-5 OUT jack of unit #1 with the RC-5 IN jack  
of unit #2.  
the HIGH indicators of all the units light up.  
4. DOLBY NR is automatically switched off for high speed du-  
plication. See Note 1 below.  
3. Connect the RC-5 OUT jack of unit #2 with the RC-5 IN jack  
of unit #3.  
5. Press the A+B button of the WRC220. All the slave units en-  
4. Up to 100 units can be connected in the same way as de-  
scribed above.  
ter record-pause mode.  
6. Set the REC LEVEL controls of the slave units to the center  
click positions. See Note 2 below.  
5. Connect the DECK A OUTPUT jacks of unit #1 with the DECK  
A INPUT jacks of unit #2.  
7. Press the TAPE A button of the WRC220. This button should  
be pressed only once and need not be pressed even when  
duplication is performed later.  
6. Connect the LOOP THROUGH A OUT jacks of unit #2 with  
the DECK A INPUT jacks of unit #3.  
Press the PLAY  
button of the WRC220. The master tape  
7. Similarly, connect the LOOP THROUGH OUT and DECK A  
INPUT jacks of other units up to unit #100.  
in Well A of unit #1 starts to be played and both Wells A and  
B of the units #2 and after start recording.  
8. Set the INPUT SELECT switches of units #2 and after to A.  
* WRC220 is sold separately.  
8. To stop duplication, press the STOP button of the WRC220.  
Notes  
Observe the following notes when dubbing a Dolby NR encoded  
master tape at high speed.  
NORMAL SPEED DUPLICATION  
1) Dolby NR has a special dynamic characteristic (with respect  
to the time axis) by responding to the frequency and level  
and can process signals correctly only in real time. However,  
as the high speed duplication alters the relationship between  
the audio signals and time considerably, the Dolby NR is  
switched automatically off in the high speed duplication mode.  
If the source was recorded with Dolby NR, the copies will be  
recorded with the same Dolby NR.  
1. Insert the blank cassettes in both Wells A and B of all units.  
2. Press the TAPE SPEED NORM buttons of all the units so  
that the NORMAL indicators of all the units light up.  
3. Set the DOLBY NR switches to the desired setting on all the  
units to record the tapes with noise reduction.  
4. Press the A+B button on the WRC220. All the slave units en-  
ter record-pause mode.  
2) The difference in signal levels between the duplicated tape  
and source master tape should be no more than 1 dB ; if the  
PMD520 is used as the source. The PMD520 has been de-  
signed so that the difference in level between these tapes is  
within the standard when the REC LEVEL control is set to  
the center click position.  
5. Play the source adjust the REC LEVEL controls of the slave  
units so that the red segments of their level meters light only  
at peaks in the music.  
6. Press the A+B button on the WRC220. All units will start re-  
cording.  
7. To stop duplication, press the A+B button on the WRC220.  
3) Do not connect a tone control or equalizer components for  
these components may affect the duplication characteristics.  
Note:  
4) During High Speed Operation the factory bias setting is used.  
Observe the following notes when dubbing a Dolby NR encoded  
master tape at normal speed.  
QMS (QUICK MUSIC SEARCH)  
1) The difference in signal levels between the duplicated tape  
and source master tape should be no more than 1 dB ; if the  
PMD520 is used as the source. The PMD520 has been de-  
signed so that the difference in level between these tapes is  
within the standard when the REC LEVEL control is set to  
the center click position.  
The QMS is available only via a remote control when the well is  
in stop or play mode.  
1. From the remote control unit, select the well (Well A or B).  
2. Using the numeric keys of the remote control unit, input the  
number of music programs to be skipped (up to 15).  
2) If the master tape was recorded with Dolby NR and the slaves  
are to have the same Dolby NR, set Dolby NR off for both the  
master and the slave.  
3. The input number is shown as "P-  
4. Press the FF or REW button of the remote control  
unit to start the QMS operation.  
" on the display.  
5. The unit winds tape at a high speed while detecting blanks  
between music programs, and enters pause mode when the  
set number of blank space have been detected.  
6. Press the PLAY  
button to start playback.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Medium-frequency gain  
The internal oscillator outputs a 3 kHz signal in the range of  
AUTO BIAS & EQ SYSTEM  
4
dB. This signal is recorded and played to adjust the recording  
gain at around 3 kHz so that the playback output becomes the  
standard level as shown by B in Figure 3.  
System Operation Description  
This system sets the recording bias, recording gain, medium-  
frequency gain, high-frequency gain and high-frequency peak  
automatically so that the characteristics of the tape in use can  
be exhibited fully.  
Figure 3  
C
30  
D/A output from the microcomputer  
A
B
20  
10  
0
As shown in Figure 1, the microcomputer adjusts each of the  
bias, gain, medium-frequency gain, high-frequency gain and  
high-frequency peak levels to one of 64 steps every 100 msec.  
by using a 6-bit digital-to-analog converter.  
-10  
400Hz  
3kHz  
12.5kHz  
20 30 50  
100  
200 300 500  
1k  
2k 3k 5k  
10k  
20k  
Frequency (Hz)  
Figure 1  
High-frequency gain  
The internal oscillator outputs a 12.5 kHz signal in the range of  
3 dB. This signal is recorded and played to adjust the record-  
ing gain at around 12.5 kHz so that the playback output be-  
comes the standard level as shown by C in Figure 3.  
The following conditions should be met so that the adjustment  
can be started.  
64 Step  
¡ A cassette tape with unbroken erasure protect tabs should  
100msec  
be loaded.  
¡ The mechanism should be in stop mode.  
¡ The tape speed should be set to normal. (The adjustment is  
Time  
not available with the high speed.)  
Bias setting  
To start the adjustment, press the REC MUTE while pressing  
The recording bias is set as shown below according to the char-  
acteristics of the record head.  
Set frequency: 6.3 kHz  
Set bias point: As shown in Figure 2, the bias point is set so that  
the output level is lower by -5 dB (Normal or High tape) or -2.5  
dB (Metal tape) than the peak point. This setting is the optimum  
point for utilizing the tape performance (MOL, third-order dis-  
tortion) available from the record head in use.  
the REC  
button.  
Ab will appear on the display followed by a number that will  
count down until the adjustment is complete.  
Pressing the STOP  
If an Error occurs please refer to page 13.  
After the adjustment, the tape is rewind automatically to the point  
where the adjustment was started.  
button during adjustment cancels it.  
The AUTO BIAS indicator lights up after the adjustment.  
The AUTO BIAS and EQ system uses 3 memory areas for  
the normal, High and Metal tapes.  
The BIAS RESET buttons will return to the standard charac-  
Figure 2  
teristics for the normal, High and Metal tapes.  
Peak point  
The data obtained by the adjustment is held in the EEPROM  
even after the unit is turned off.  
-5dB (NORMAL)  
In case the adjustment fails, "Err" (error) is displayed on the  
counter for 15 seconds, then the factory-set data is recalled.  
In case the adjustment is canceled in the middle or the unit  
is turned off during the adjustment, all data adjusted until  
then are invalidated.  
The tape is not rewound in case an adjustment error occurs  
BIAS level  
BIAS point  
or the adjustment is canceled in the middle.  
When the data obtained by the adjustment is held in memory  
and the BIAS RESET indicator is lit, the adjusted setting is  
recalled at the moment a tape is loaded.  
Recording gain setting  
An internal oscillator outputs a 400 Hz signal in the range of  
5
dB. This signal is recorded and played to adjust the recording  
gain so that the output level becomes the standard level. This  
adjustment is not performed at a specific frequency but varies  
only the gain, regardless of the frequency, as shown by A in  
Figure 3.  
To use the factory-set data, press the BIAS RESET button  
so that the indicator is off.  
Performing this adjustment overwrites the previously stored  
adjustment data.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARE AND MAINTENANCE  
REPAIRS  
Only the most competent and qualified technicians should be  
allowed to service your unit. Marantz and its factory trained  
warranty station personnel have the knowledge and special  
equipment needed for repair and calibration of this precision  
instrument.  
This section describes the care and maintenance tasks that  
must be performed to optimize the operation of your Marantz  
equipment.  
In the event of difficulty, call the toll-free telephone number listed  
on the face of the warranty to obtain the name address of the  
Marantz Authorized Service Center nearest you. In many cases,  
the dealer where you purchased your Marantz unit may be  
equipped to provide service. Please include the model, serial  
number of your unit together with a copy of your purchase re-  
ceipt and a full description of what you feel is abnormal in its  
behavior.  
MAINTENANCE  
HEAD CLEANING  
If the heads are not cleaned for a long period, dirt or dust may  
be deposited on the heads and capstans, causing degraded  
high-frequency characteristics, volume drop, or degraded re-  
cording and erasure performances.  
To prevent this, clean the heads, etc., periodically as follows.  
1. Turn the power off.  
TROUBLESHOOTING  
2. As shown in Figure 10, clean the parts which come in con-  
tact with tape, including the heads, capstans, tape guides,  
pinch wheels, etc., with a cotton swab soaked in head clean-  
ing solution or denatured alchohol.  
Should faults occur, it is in many cases not necessary to consult  
your dealer or technical service department. On the basis of  
the following checks you will be able to rectify a number of faults  
yourself without difficulty.  
If the fault cannot be remedied after the following check, please  
consult your dealer or nearest Marantz service agent.  
HEAD DEMAGNETIZATION  
The tape does not travel.  
When a magnetized metallic objects (such as a screwdriver tip,  
etc.) comes in contact with a head or capstan, or when the deck  
has been used for a long period of time, the head may be  
magnetized and noise may be generated. If the head is extremely  
magnetized, the high frequencies in recorded tapes could even  
be erased due to it. To prevent this, demagnetize the heads and  
capstans periodically (every 20 hours of use) using a  
commercially-available head demagnetizer. (For the operation,  
please refer to the instruction manual supplied with your head  
demagnetizer.)  
1. Check that the power cord is plugged properly.  
2. Check that the POWER switch is set to ON.  
3. Check that the tape is rewound.  
The tape travels, but no sound is output.  
1. Check that the cassette tape is recorded.  
2. Check that the mixer, amplifiers and speakers are connected  
and functioning properly.  
Tape will not record.  
1. Check that the protection tabs of cassette tape are not broken.  
2. Check that the recording level is set properly.  
Caution:  
Be sure to turn the power of the cassette deck off before  
using a head demagnetizer.  
Sound is distorted.  
1. Check that the recording level is not too high.  
2. Check that the head is not dirty.  
CLEANING OF EQUIPMENT EXTERNAL SURFACES  
Sound is unstable.  
The exterior finish of your unit will last indefinitely with proper  
care and cleaning. Never use scouring pads, steel wool, scour-  
ing powders or harsh chemical agents (e.g., lye solution), al-  
cohol, thinners, benzine, insecticide or other volatile substances  
as these will mar the finish of the equipment. Likewise, never  
use cloths containing chemical substances. If the equipment  
gets dirty, wipe the external surfaces with a soft, lint -free cloth.  
If the equipment becomes heavily soiled:  
1. Check that the head is not dirty.  
2. Check that the pinch wheels (capstans) are not dirty.  
3. Check that the tape is wound regularly.  
Noise is noticeable.  
1. Check that the head is not dirty.  
2. Check that the head is not magnetized.  
3. Check that the DOLBY NR switch is set properly according  
dilute some washing up liquid in water, in a ratio of one part  
to the tape.  
detergent to six parts water  
Hum interferes with the sound.  
dip a soft, lint free cloth in the solution and wring the cloth  
1. Check that cords are connected properly.  
out until it is damp  
2. Check that there is not any source of magnetism (TV, motor,  
transformer, etc.) placed near the unit ?  
wipe the equipment with the damp cloth  
3. When this unit and amplifier are stacked, hum noise is some-  
times generated depending on the amplifier model. In such  
a case, place the components in positions where interfer-  
ence does not occur.  
dry the equipment by wiping it with a dry cloth  
NOTICE  
The tape counters are only approximate measurements of  
minutes and seconds and are not intended for timing-critical  
applications.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RC-5 Command Table  
TECHNICAL SPECIFICATIONS  
Command  
RC-5 Code  
1800  
0
Track System........................................... 4 Track, 2 Channel  
Head System  
1
1801  
2
1802  
Rec Play Head ........................................Hard Permalloy  
Erase Head ........................................... Dual Gap Ferrite  
Approx Head Life .................................................. 1000H  
Recording/Erasure System ........................ AC 105 kHz Bias  
Motor System  
3
1803  
4
1804  
5
1805  
6
1806  
7
1807  
Capstan ................................ DC Servo Controlled Motor  
Reel .................................................................. DC Motor  
Overall S/N, NR off, ”A” weighted  
8
1808  
9
1809  
Next  
1832  
Normal ..................................................................... 57dB  
High ......................................................................... 58dB  
Metal........................................................................ 58dB  
Overall S/N, Dolby C NR, ”A” weighted  
Previous  
1833  
Monitor Select  
Recording Pause  
Record Blank  
Mechanism A  
Mechanism B  
Pause  
1838  
1840  
1842  
Normal ..................................................................... 74dB  
High ......................................................................... 75dB  
Metal........................................................................ 75dB  
Frequency Response, Rec/Play, NR off  
1844  
1846  
1848  
Auto Rewind  
Play  
185000  
1853  
Normal ......................................................... 40Hz–16kHz  
High ............................................................. 40Hz–17kHz  
Metal............................................................ 40Hz–18kHz  
Dolby NR effect, B/C , S/N improvement,  
Normal Speed  
High Speed  
Stop  
185311  
185312  
1854  
CCIR/ARM weighted .................................. B 8dB, C 17dB  
Output  
Wind  
1852  
Rewind  
1850  
Line....................................................................... 540mV  
Phone ..................................................................... 50mV  
Output Impedance  
Record  
1855  
Auto Bias  
A+B Synchronous Recording  
Connect  
185509  
185510  
1856  
Line............................................................................47  
Phone ...................................................................... 120Ω  
Input Sensitivity  
Disconnect  
1857  
Line....................................................................... 100mV  
Input Impedance  
Line........................................................................ 100kΩ  
Fine Speed Control ........................................................ 3%  
Wow & Flutter  
W RMS................................................... 0.07% (Jis WTD)  
Power Supply  
Power Requirement .................................. 120V AC 60Hz  
Power Consumption ............................................... 0.25A  
Dimensions  
Width ................................................ 19 inches (483mm)  
Height .......................................... 5 3/16 inches (132mm)  
Depth........................................... 13 3/8 inches (340mm)  
Net Weight ..................................................... 15.4 lbs. (7kg)  
Specifications subject to change without prior notice.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 4  
R
MODEL NO. PMD520  
AC120V 60Hz 0.25A  
LOOP  
MADE IN JAPAN  
THROUGH  
DECK  
LINE  
B
DECK  
LINE  
A
REMOTE  
RC-5 EXT  
A
OUT  
IN  
OUT  
IN  
OUT  
L
L
L
IN  
CONTROL  
I
/
O
INPUT  
MPX  
FILTER  
ON OFF  
SELECT  
A.  
B
A
R
R
R
OUT  
A
D B  
C
G E F  
H
I
q
w
FULLY INDEPENDENT DOUBLE CASETTE DECK PMD520  
DOLBY B–C NR HX PRO  
L
L
-20 15 10  
6
3
0
3
+6dB  
-20 15 10  
6
3
0
3
+6dB  
R
R
POWER  
DOLBY NR  
OFFBC  
DOLBY NR  
OFFBC  
TAPE TIME  
CONT  
RESET  
A+B  
RESET  
TAPE TIME  
AUTO  
REW  
TAPE SPEED  
HIGH  
OVERLAP  
REC  
A+B  
NORM  
A
B
OFF  
RECPLAY  
OFF  
RECPLAY  
BIAS  
RESET  
BIAS  
RESET  
MONITOR  
MONITOR  
HP SELECT  
3HEAD  
3HEAD  
DC SERVO CONTROLLED MOTOR AUTO TAPE SELECTOR  
DC SERVO CONTROLLED MOTOR  
/
AUTO TAPE SELECTOR  
/
TIMER  
TIMER  
5
5
4
0
6
4
0
6
STOP  
PLAY  
REC MUTE  
REC  
STOP  
PLAY  
REC MUTE  
REC  
3
1
7
3
1
7
9
FINE SPEED  
BALANCE  
HP LEVEL  
PHONES  
2
8
2
8
9
10  
10  
AUTO BIAS  
AUTO BIAS  
REC LEVEL  
REC/PLAY  
REC/PLAY  
! ! !  
e
!
!
!
e
a
b
L
L
-20 15 10  
6
3
0
3
+6dB  
-20 15 10  
6
3
0
3
+6dB  
R
R
r !  
2
DOLBY NR  
OFFBC  
DOLBY NR  
OFFBC  
DOLBY NR  
OFFBC  
DOLBY NR  
OFFBC  
TAPE TIME  
CONT  
RESET  
A+B  
RESET  
TAPE TIME  
TAPE TIME  
CONT  
RESET  
A+B  
RESET  
TAPE TIME  
e
c
d
AUTO  
REW  
TAPE SPEED  
HIGH  
OVERLAP  
REC  
i
o
AUTO  
REW  
TAPE SPEED  
HIGH  
g
f
OVERLAP  
REC  
y
NORM  
NORM  
t
u
OFF  
RECPLAY  
OFF  
RECPLAY  
BIAS  
RESET  
BIAS  
RESET  
OFF  
RECPLAY  
OFF  
RECPLAY  
BIAS  
RESET  
BIAS  
RESET  
MONITOR  
MONITOR  
MONITOR  
MONITOR  
TIMER  
TIMER  
TIMER  
TIMER  
! ! !  
h i  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CASCADE OPERATION  
Figure 5  
IN 1  
IN 2  
IN 3  
OUT  
MIC  
MIXER  
R
MODEL NO. PMD520  
AC120V 60Hz 0.25A  
LOOP  
MADE IN JAPAN  
THROUGH  
DECK  
LINE  
IN  
B
DECK  
LINE  
IN  
A
REMOTE  
RC-5  
A
OUT  
OUT  
OUT  
EXT  
EXT  
EXT  
L
L
L
IN  
CONTROL  
I
I
I
/
/
/
O
INPUT  
MPX  
SELECT  
FILTER  
ON OFF  
A.  
B
A
R
R
R
OUT  
R
MODEL NO. PMD520  
AC120V 60Hz 0.25A  
LOOP  
THROUGH  
OUT  
MADE IN JAPAN  
DECK  
LINE  
IN  
B
DECK  
LINE  
IN  
A
REMOTE  
RC-5  
A
OUT  
OUT  
L
L
L
IN  
CONTROL  
O
INPUT  
MPX  
FILTER  
ON OFF  
SELECT  
A.  
B
A
R
R
R
OUT  
R
MODEL NO. PMD520  
AC120V 60Hz 0.25A  
LOOP  
THROUGH  
OUT  
MADE IN JAPAN  
DECK  
LINE  
IN  
B
DECK  
LINE  
IN  
A
REMOTE  
RC-5  
A
OUT  
OUT  
L
L
L
IN  
CONTROL  
O
INPUT  
MPX  
FILTER  
ON OFF  
SELECT  
A.  
B
A
R
R
R
OUT  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DUPLICATION SYNCHRONIZATION  
WRC220  
Figure 6  
TAPE A  
TAPE B  
CD  
AUTO  
CD  
A
B
TAPE A  
TAPE B  
CD  
AUTO  
REW  
PREV  
REW  
FF  
NEXT  
BIAS  
1×  
2×  
PLAY  
STOP  
NORMAL  
SPEED  
HIGH  
SPEED  
RECORD  
A+B  
RECORD  
RECORD  
MUTE  
AUTO  
BIAS  
UNIT #1  
UNIT #2  
UNIT #3  
R
MODEL NO. PMD520  
AC120V 60Hz 0.25A  
LOOP  
MADE IN JAPAN  
THROUGH  
DECK  
LINE  
IN  
B
DECK  
LINE  
IN  
A
REMOTE  
RC-5  
A
OUT  
OUT  
OUT  
EXT  
EXT  
EXT  
L
L
L
IN  
CONTROL  
I
I
I
/
/
/
O
INPUT  
MPX  
SELECT  
FILTER  
ON OFF  
A.  
B
A
R
R
R
OUT  
R
MODEL NO. PMD520  
AC120V 60Hz 0.25A  
LOOP  
THROUGH  
OUT  
MADE IN JAPAN  
DECK  
LINE  
IN  
B
DECK  
LINE  
IN  
A
REMOTE  
RC-5  
A
OUT  
OUT  
L
L
L
IN  
CONTROL  
O
INPUT  
MPX  
FILTER  
ON OFF  
SELECT  
A.  
B
A
R
R
R
OUT  
R
MODEL NO. PMD520  
AC120V 60Hz 0.25A  
MADE IN JAPAN  
DECK  
LINE  
IN  
B
DECK  
LINE  
IN  
A
REMOTE  
RC-5  
OUT  
OUT  
L
L
L
IN  
CONTROL  
O
INPUT  
MPX  
FILTER  
ON OFF  
SELECT  
A.  
B
A
R
R
R
OUT  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Metal tape  
detection hole  
High tape  
detection hole  
Figure 7  
Figure 8  
Figure 9  
Be sure to close the casette holder cover when the  
unit is not to be used for a long period of time.  
Figure 10  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Land Pride Lawn Mower RBT45108 User Manual
Lenovo Personal Computer 0958B2U User Manual
Lexmark Photo Printer P915 User Manual
LG Electronics Cell Phone C900B User Manual
LG Electronics Cell Phone VX5500 User Manual
Magnavox CRT Television 27TP83 C101 User Manual
Magnavox Flat Panel Television 42MF521D User Manual
Master Bilt Refrigerator ATMC 124DSS User Manual
Memorex MP3 Player MPD8846 User Manual
Metra Electronics eBook Reader 99 7424 User Manual