				INTRODUCTION   
					THANK YOU!...   
					for choosing the Manley 50 Watt Monoblock Amplifiers. Designed around the concept that less is   
					more, the Manley 50 Watt Monoblock Amplifiers use only the best available components, with the   
					shortest and cleanest signal path possible, and with the use of our own milling equipment we can   
					provide you with an amplifier that looks as good as it sounds. We have developed a magnetics   
					winding department right here at Manley Labs where we design and wind the audio transformers.   
					David Manley has invented a brand new winding technique for the output transformer which exactly   
					preserves equality in the push-pull halves of the output stage. This breakthrough has once again put   
					Manley Labs on the leading edge.   
					Thank you again, and please enjoy!   
					GENERAL NOTES   
					LOCATION & VENTILATION   
					The Manley 50 Watt Monoblock Amplifiers must be installed in a stable location with ample   
					ventilation. Allow a minimum of 2 inches of clearance on the top and sides of the amplifier, such   
					that a constant flow of air can flow throughout the ventilation openings. We also recommend that   
					the amplifier and preamplifier be placed at least 10 inches apart. Do not place amplifiers directly on   
					high pile carpet or any other surface that will block the ventilation vents.   
					WATER&MOISTURE   
					SERVICING   
					The user should not attempt to service the amplifier beyond that described in the owner's manual.   
					Refer all servicing other than biasing and tube replacement to Manley Laboratories   
					SPECIALNOTES   
					Tubes may become loose during transit. Straighten and press down each tube before plugging the   
					amplifier into the mains socket. Furthermore, NEVER touch the tubes after the amplifier has been   
					switched on, the tubes become very hot during operation and should only be handled after the power   
					has been turned off and the tubes have cooled.   
					WARNING!   
					! 
					TO PREVENT THE RISK OF ELECTRIC SHOCK   
					DO NOT OPEN THE CABINET   
					REFER SERVICING TO   
					QUALIFIED PERSONNEL   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				MAINS CONNECTIONS   
					Your amplifier has been factory set to the correct mains voltage for your country. The voltage   
					setting is marked on the serial badge, located on the rear panel. Check that this complies with your   
					local supply.   
					Export units for certain markets have a moulded mains plug fitted to comply with local requirements.   
					If your unit does not have a plug fitted the colored wires should be connected to the appropriate plug   
					terminals in accordance with the following code.   
					GREEN/YELLOW   
					BLUE   
					BROWN   
					EARTH   
					NEUTRAL   
					LIVE   
					terminal   
					terminal   
					terminal   
					As the colors of the wires in the mains lead may not correspond with the colored marking identifying   
					the terminals in your plug proceed as follows;   
					The wire which is colored GREEN/YELLOW must be connected to the terminal in the plug which is   
					marked by the letter E or by the safety earth symbol or colored GREEN or GREEN and YELLOW.   
					The wire which is colored BLUE must be connected to the terminal in the plug which is marked by   
					the letter N or colored BLACK.   
					The wire which is colored BROWN must be connected to the terminal in the plug which is marked   
					by the letter L or colored RED.   
					DO NOT CONNECT/SWITCH ON THE MAINS SUPPLY UNTIL ALL OTHER CONNEC-   
					TIONS HAVE BEEN MADE.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				CONNECTING YOUR AMPLIFIER   
					Setting up your amplifier is rather easy.   
					1. Connect all source components (turntable, CD, Tuner, Tape DAT, etc.) to your preamplifier.   
					2. Connect the interconnects from the output of the preamplifier or switching center to the   
					RCA input on the top rear of the amplifier.   
					3. Connect the hot or "+" speaker cable to the red binding post and the common or "-"   
					speaker cable to the black binding post (See diagram 2). Ensure that the other end of the   
					cable is connected correctly to the speaker. Tighten the binding posts by hand. If you   
					use a nut-driver (3/8") do not over-tighten the posts or you may breaak the connection   
					inside the amplifier.   
					4. Insure that the "mains" switch on the front panel is in the "off" or "0" position.   
					5. Turn on Preamplifier and any source components you plan to use.   
					6. Plug amplifier into wall outlet.   
					7. Turn on the amplifier and allow it to 'warm up' a minute or so before playing any audio   
					signal.   
					8. Turn up the volume and enjoy.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				BIAS PROCEDURES   
					The Manley 50 Watt Amplfier is a fixed bias system that requires very little attention. If you wish to   
					adjust or check the bias, complete the following steps. For this procedure you will need a multimeter   
					to read millivolts (less than 2 volt range) and a small flat screwdriver.   
					1.   
					Looking at the front section of the top plate of the amplifier, you can see 4 red tip jacks and 1   
					black tip jack. To measure the current draw of each output tube place the positive probe (red) into   
					the red tip jack for the tube you wish to measure and the negative probe (black) in the black   
					(GROUND) tip jack and set the meter to read 'millivolts'.   
					2.   
					Each of the four (4) output tubes can have its own bias adjusted by altering its own bias   
					adjust pot. The numbering sequence for the 4 output tubes runs from left to right, as do the   
					corresponding tip jacks (measurement points). The bias adjust pots are located on the top side of   
					the amplifier, therefore it will be NOT be necessary to remove the bottom cover to changing the   
					bias. They also read left to right.   
					3.   
					The first step to setting the bias is to turn on the amplifier and insure that there is zero signal   
					input. Also, leave your loadspeakers connected as these provide an ideal load on the output. Never   
					operate your amplifiers without a suitable load or speakers attatched. It is recommended that you   
					leave the amplifier on long enough to ensure that the tubes have reached their stable current draw.   
					5.   
					Set your meter to read VOLTS DC. You will be measuring less than 1 volt so set your meter   
					for a low range if it is not an autoranging meter. Place the probes in the first red tip jack (negative   
					probes remains in the black tip jack for whole biasing procedure) and adjust the first bias trim pot   
					located on the left side top deck of the amplifier until you measure approx. 200 mVDC (0.2VDC).   
					Since you are measuring across a 10 ohm cathode resistor, this would correspond to a 20 mA bias   
					current.   
					6.   
					If you are unable to bring the bias voltage down to 200 mV on any tube then we recommend   
					that the tube be carefully watched or replaced.   
					7.   
					Follow step five with the remaining tubes. Once they are all set, your amplifier should be in   
					perfectoperation.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				OPERATIONAL NOTES   
					SWITCHINGON   
					The power switch is located on the lower left hand corner of the front panel. Push the top of the   
					rocker switch (1) to turn on the amplifier and the bottom of the rocker to turn off the amplifier. The   
					LED on the right side of the front panel will illuminate indicating that the amplifier is operating. Do   
					not turn on and off the amplifier in rapid succession.   
					RUNNING   
					It is not recommended that you leave your amplifier permanently switched on. This only wastes   
					electricity and tube life. Your amplifier has solid state rectification and reaches peak operating   
					condition in approximately 30 minutes.   
					TUBELIFE   
					As with all tubes, their quality degrades with age. This is due to cathode emission, a natural process   
					found in all tubes. We recommend that you have your amplifier checked every 3-4 years, depending   
					on usage, sometimes the amplifier will require re-tubing after this time has elapsed, although we   
					have many cases of extreme long life recorded-- 40,000 hours and still counting!.   
					SPECIAL NOTE   
					The Manley 50 Watt Monoblocks are equipped with a voltage change-over switch located under the   
					bottom cover. Insure that this switch is set at 110 if your mains voltage is 100,110,120, or 127   
					Volts. Set this switch to 220 if your mains voltage is 220, 227, or 240 Volts.   
					Changing the light bulb:   
					The lamp which back-lights the Manley insert on the faceplate is a fuse-lamp style lamp. Should it   
					burn out, turn off and unplug the amplifer from the mains first. Then remove the bottom cover.   
					Carefully pry out the old lamp from its clips and replace with one of the same type. Although it   
					looks like a fuse, it is really a light bulb!! Don't put a fuse in there!!   
					The fuse lamp is 1 1/4" x 1/4" 8Volts, 300mA.   
					Fuses:   
					Always replace with same type and rating. Should the B+ fuse blow (the fuse nearer to the output   
					binding posts) this usually indicates a tube has blown. One should visually inspect the pcb to look   
					for any burnt resistors a blown tube may have taken out. Also a good test is to measure the resistance   
					of each catode resistor. This is done in a similar fashion to checking the bias, except do this test with   
					the amplifier turned OFF, and set your meter for Ohms. Each cathode resistor should measure 10   
					ohms.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SPECIFICATIONS   
					Vacuum Tubes:   
					4 x EL84, 1 x 12AT7WA, 1 x 6414   
					53 Watts   
					Output Power   
					Frequency Response, +/- .5 dB   
					Input Sensitivity   
					20 Hz - 20 KHz   
					460 mV   
					Input Impedance   
					100 KOhm   
					Load Impedance   
					S/N Ratio @350W   
					5 Ohm. Factory preset for 5 Ohm   
					-80 dB   
					Power Consumption   
					Mains Fuse   
					100 Watts   
					168 Watts   
					Quiescent   
					Full Power   
					100, 110, 120V   
					220, 240 V   
					3 A (Slo-Blo)   
					2 A (Slo-Blo)   
					Dimensions   
					Weight   
					W=11, D=8, H=4.5 inches   
					11 lbs   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				WARRANTY   
					All Manley Laboratories equipment is covered by a limited warranty against defects in materials   
					andworkmanshipforaperiodof90daysfromdateofpurchasetotheoriginalpurchaseronly.A   
					furtheroptionallimited5yearwarrantyisavailabletotheoriginalpurchaseruponproper   
					registrationofownershipwithin30daysofdateoffirstpurchase.   
					Properregistrationismadebyfillingoutandreturningtothefactorythewarrantycardattachedto   
					this general warranty statement, along with a copy of the original sales receipt as proof of the   
					originaldateofpurchase. Only1cardisissuedwitheachunit, andtheserialnumberisalready   
					recordedonit.   
					Ifthewarrantyregistrationcardhasalreadybeenremovedthenthisisnotanewunit, andis   
					therefore not warranted by the factory. If you believe this to be a new unit then please contact the   
					factorywiththedetailsofpurchase.   
					Thiswarrantyisprovidedbythedealerwheretheunitwaspurchased,andbyManleyLaboratories,   
					Inc. Underthetermsofthewarrantydefectivepartswillberepairedorreplacedwithoutcharge,   
					exceptingthecostoftubes.Nowarrantyisofferedontubes,unless:   
					1. A Manley Laboratories preamplifier is used with a Manley Laboratories amplifier.   
					2. The warranty registration card is filled out.   
					In such a case a 6 month warranty on tubes is available with the correct recording of the serial   
					numberofthepreamplifieronyourwarrantyregistrationcard.   
					IfaManleyLaboratories productfailstomeettheabovewarranty,thenthepurchaser'ssole   
					remedyshallbetoreturntheproducttoManleyLaboratories, wherethedefectwillberepaired   
					without charge for parts and labor. The product will then be returned via prepaid, insured   
					freight, method and carrier to be determined solely by Manley Laboratories. All returns to the   
					factory must be in the original packing, (new packing will be supplied for no charge if needed),   
					accompanied by a written description of the defect, and must be shipped to Manley   
					Laboratories via insured freight at the customer's own expense. Charges for unauthorized   
					service and transportation costs are not reimbursable under this warranty, and all warrantees,   
					express or implied, become null and void where the product has been damaged by misuse,   
					accident, neglect, modification, tampering or unauthorized alteration by anyone other than   
					Manley Laboratories.   
					Thewarrantorassumesnoliabilityforpropertydamageoranyotherincidentalorconsequental   
					damagewhatsoeverwhichmayresultfromfailureofthisproduct.Anyandallwarranteesof   
					merchantabilityandfitnessimpliedbylawarelimitedtothedurationoftheexpressedwarranty.   
					AllwarranteesapplyonlytoManleyLaboratoriesproductspurchasedandusedintheUSA.   
					Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts, sotheabove   
					limitations may not apply to you. Some states do not allow the exclusion or limitation of incidental   
					orconsequentialdamges,sotheaboveexclusionmaynotapplytoyou.   
					Thiswarrantygivesyouspecificlegalrightsandyoumayalsohaveotherrightswhichvaryfrom   
					state to state.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				WARRANTYREGISTRATION   
					We ask that you please fill out this registration form and send the bottom half to:   
					MANLEY LABORATORIES   
					REGISTRATION DEPARTMENT   
					13880 MAGNOLIA AVE.   
					CHINO CA, 91710   
					Registration entitles you to product support, full warranty benefits, and notice of product   
					enhancements and upgrades. You MUST complete and return the following to validate your   
					warranty and registration. Thank you again for choosing Manley Laboratories.   
					MODEL ____________________ SERIAL No. ______________________   
					PURCHASE DATE ______________ SUPPLIER ______________________   
					--------------------------------------------------------------------------------------------------------   
					PLEASE DETACH THIS PORTION AND SEND IT TO MANLEY LABORATORIES   
					MODEL ____________________   
					SERIAL No. ______________________   
					PURCHASE DATE ______________ SUPPLIER _______________________   
					NAME OF OWNER _______________________________________________   
					ADDRESS ______________________________________________________   
					CITY, STATE, ZIP________________________________________________   
					TELEPHONE NUMBER ___________________________________________   
					Serial #'s of Associated Manley Laboratories Equipment ___________________   