MGE UPS SYSTEMS  
Pulsar EXtreme C UPS  
700/1000/1500 VA  
Yo u r n e t w o r k ’s  
p o w e r p ro tec t io n  
li nk  
Maximum security for  
your servers, PBXs and  
network equipment ...  
in minimum space.  
Like a climber who snaps on a  
"biner" for a safe ascension, you  
can count on Pulsar EXtreme C  
to protect you no matter what.  
Pulsar EXtreme C offers the best  
in power protection plus the "C"  
for compact design.  
High performance  
and reliability  
High availability  
Advanced communications  
Ease of use  
Flexibility and scalability  
W
Download from Www.Somanuals.com. All Manuals Search And Download.  
A complete range  
Pulsar EXtreme C UPSs have been  
designed to meet the needs of modern  
equipment, including network, intranet  
and internet servers, internetworking  
devices, computer and telecom (PBX)  
centres, medical equipment and sensitive  
industrial processes.  
Pulsar EXtreme C is available in both  
tower and rack versions with power  
ratings from 700 to 1500 VA.  
Which model to choose ?  
Protected applications  
100-line PABX (300 VA)  
1 UNIX server (650 VA)  
Best choices  
Pulsar EXtreme 700C + 3 Pulsar EXB 700C  
Pulsar EXtreme 700C  
Pulsar EXtreme 1000C + Pulsar EXB 1000C  
Pulsar EXtreme 1500C  
Pulsar EXtreme 1500C + Pulsar EXB 1500C  
Pulsar EXtreme 1500C + 2 Pulsar EXB 1500C  
Pulsar EXtreme 1500C + 3 Pulsar EXB 1500C  
Backup time  
2 hours  
7 minutes  
50 minutes  
6 minutes  
25 minutes  
40 minutes  
80 minutes  
6 Internet servers/1U rack (1500 VA)  
High performance LAN Switch (1500 VA)  
High performance and reliability  
High availability  
Pulsar EXtreme C provides power protection and extends battery life to increase  
system reliability.  
Pulsar EXtreme C UPSs guarantee a high level of  
availability, equal to 99.999% or higher.  
On-line double conversion  
technology  
Pulsar EXtreme C UPSs use double  
conversion (on-line) technology, the only  
way to overcome all power problems.  
The battery is used only as a backup source.  
High-performance battery  
charger  
The Pulsar EXtreme battery charger:  
Cold start on battery power  
This function ensures trouble-free start-up  
of your applications even during a utility  
power outage.  
• reduces battery recharge time (80%  
backup time recovered in two hours);  
Automatic bypass  
• increases the service life of the battery  
by taking into account manufacturer  
parameters and battery aging;  
In the event of an overload or UPS fault,  
Pulsar EXtreme C automatically transfers  
the load to utility AC power.  
Automatic bypass  
Bypass mode  
On-line mode  
• protects the battery against damage  
caused by deep discharge;  
Filter  
Filter  
Battery  
High-availability pack  
• avoids disturbances on the distribution  
system by correcting the power factor;  
A Pulsar STS source transfer switch  
combined with two Pulsar EXtreme C UPSs  
provides effective power redundancy.  
Whatever the disturbances on the distribution system, the  
waveform is regenerated via the AC to DC then DC to AC  
conversion process.  
• avoids propagating faults on the  
distribution system (backfeed  
protection).  
Wide input-voltage range  
Pulsar EXtreme C UPSs have a very wide  
input-voltage range from 120 to 276 V,  
optimized to improve compatibility with  
engine generator sets and reduce the  
number of transfers to battery power.  
The batteries are used only for the most  
serious incidents, maximizing available  
backup time and extending battery life.  
Pulsar EXtreme Rack  
"preferred" source  
Certified compliance with  
CE and UL standards  
Pulsar EXtreme Rack  
"alternate" source  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Characteristics  
Pulsar EXtreme  
700 C  
1000 C  
1500 C  
General  
Power (Pn)  
700 VA / 490 W  
1000 VA / 700 W  
1500 VA / 1050 W  
Input-voltage range  
Frequency range  
120/140/160 to 276 volts without using battery power (1)  
50/60 Hz (auto-selection)  
Power factor (THDI)  
Sinusoïdal output voltage  
Harmonic distortion  
Efficiency  
Crest factor  
Short circuit current (A)  
Overload capacity (Online mode)  
>0.95 (< 5%)  
200/208/220/230/240 Volts  
<4% on linear load, <6% on non-linear load  
85%  
3:1  
25  
87%  
3:1  
29  
88%  
3:1  
29  
110% permanent, 130% 12s, >130% 1.5s  
Batteries  
Backup time  
100% Pn  
50% Pn  
14  
47  
82  
124  
100% Pn  
50% Pn  
17  
59  
93  
136  
100% Pn  
50% Pn  
19  
79  
119  
168  
Standard  
7
24  
41  
53  
7
27  
47  
64  
6
24  
43  
62  
Pulsar EXtreme C + 1 Pulsar EXB  
Pulsar EXtreme C + 2 Pulsar EXB  
Pulsar EXtreme C + 3 Pulsar EXB  
Automatic battery test  
Yes, at regular intervals without risk of interrupting protected applications  
Communicatio  
n
USB port  
yes  
yes  
yes  
yes  
yes  
yes  
RS232 port  
Optional cards  
SNMP card  
status information card  
Environment  
Acoustic noise  
40 dBA  
<
Operating temperature  
0 to 40°C  
Standards and certifications  
Performance  
EN 50091-3/IEC 62040-3  
EN 50091-1, EN 60950 (RD/), IEC 60950  
EN 50091-2/IEC 62040-2, EN 55022/B, FCC 47 part 15 - Subpart B - Class A,  
IEC 61000-4-2/-3/-4/-5/-6/-8/-11, IEC 61000-3-2/-3  
CE,TÜV/GS, UL, cUL, C-Tick  
Safety  
EMC  
Marking and certifications  
Design and manufacture  
(HxWxD in mm)  
ISO 9001  
(Kg)  
and Weight  
Dimensions  
UPS (electronics + battery)  
Tower  
Rack  
Tower/Rack  
Tower/Rack  
Tower/Rack  
235.5x145x400  
88(2U)x482.6x430  
10/14  
235.5x145x400  
88(2U)x482.6x430  
12/16  
235.5x145x505  
88(2U)x482.6x493  
15/20  
Electronics module  
Battery module Pulsar EXB  
CLA module (without batteries)  
11.5/17  
15/21  
21/27.5  
8.5/11.5  
2 years, extendable by contract  
Warranty  
(1) values for operation at 50%, 66% and 100% rated output  
Catalog numbers  
Format  
UPS  
Warranty + for UPS  
Pulsar EXB  
Warranty + for Pulsar EXB  
Pulsar EXtreme 1500 transformer  
Pulsar EXtreme 1500 CLA  
Warranty + for Pulsar CLA  
EXtreme 700 C  
EXtreme 1000 C  
EXtreme 1500 C  
Tower  
Rack  
66351  
66813  
66354  
66813  
Tower  
66346  
66818  
66349  
66813  
Rack  
66352  
66818  
66355  
66813  
Tower  
66347  
66818  
66350  
66813  
66357  
66359  
66818  
Rack  
66345  
66813  
66348  
66813  
66353  
66818  
66356  
66813  
66358  
66818  
RS232 and USB communications ports  
slot for a communication  
card  
alarm and battery level indicators  
press and hold to display percent load  
lamp test or buzzer off  
forced transfer to and from bypass  
status of programmable outlets 1 and 2  
operation on bypass, in ON-LINE mode  
or on battery  
automatic recognition of  
battery extension modules  
ON/OFF  
2 programmable outlets  
connectors for Pulsar EXB battery  
extension modules  
AC input connector  
MGE UPS SYSTEMS  
140, avenue Jean Kuntzmann  
ZIRST - Montbonnot Saint Martin  
38334 St Ismier Cedex - France  
Tel : (33) (0)4 76 18 30 00  
MGE0384UKO  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Laser Computer Accessories PW DD100W User Manual
Lenovo Laptop 3000 Y410 User Manual
Lenovo Tablet Y460 User Manual
Lexmark Printer Z54 User Manual
LG Electronics Cell Phone Voyager User Manual
LG Electronics Printer 42LS5700 User Manual
LG Electronics Refrigerator LDF9810BB User Manual
Makita Impact Driver 6932FDWDE User Manual
Maytag Dishwasher DWC8330 User Manual
Melissa Microwave Oven 653 115 User Manual