INSTALLATION AND
OPERATING INSTRUCTIONS
52157
PSDS11b Lighted
Non-Programmable Thermostat
WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only.
Energizer® is a registered trademark of Eveready Battery Company, Inc.
DURACELL® is a registered trademark of The Procter & Gamble Company
Thank you for your confidence in our product. To obtain the best results from your investment, please read these
instructions and acquaint yourself with your purchase. Follow the installation procedures carefully, and save these
instructions for future reference. This will save you time and minimize the chance of damaging either the thermostat or
the systems that it controls.
SYSTEM COMPATIBILITY:
This thermostat can be used with most single-stage 24 volt: gas, oil or electric heating and cooling systems, single-stage
heat pumps, or gas Millivolt heating systems.
It cannot be used with: 3-wire zone valves, 120/240 volt heating elements, or multi-stage heat pumps. Ask your dealer
for other LUXPRO thermostats to control those systems.
THERMOSTAT FEATURES:
• 1-Stage Heat / 1-Stage Cool
• Electronic Accuracy
• Innovative SAVE Feature
• Gas / Elec Fan Option
• Battery Powered Only
• Large, Easy to Read Display
• F/C Selectable Temperature Display
• Adjustable Temperature Differential / Cycle Rate
• User Temperature Display Calibration
• 5/2 Minute Selectable Minimum Run/Off Time
• On-Screen Low Battery Indicator
• 3-Year Warranty
• Set Temperature Range 45°F (7°C) degrees to 90°F
(32°C) degrees
• Clean, Attractive Design
• LuxLight® Illuminated Display Screen
• Easy to Install
• No Leveling Required
1
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING TERMINAL CONNECTIONS:
1. When attaching the wires to the thermostat, please ensure that the bare wire ends are held ALL the way into the
terminal block while the screw is being tightened.
2. Securely tighten all of the electrical terminal screws, including any unused ones. Be careful not to over tighten the
screws, they only need to be snug.
** Complete heating and/or cooling system wiring can be found in the WIRE IDENTIFICATION AND WIRING
SCHEMATICS section of this instruction sheet. The schematics shown provide component information for brand
new installations or for unreferenced wires.
SYSTEM CONFIGURATION AND SETUP OPTIONS:
On the circuit board, there are hardware settings called “jumpers”. These settings can be changed from their default
values by removing its black cap and reinstalling the cap so that it is positioned
on only one (1) of the metal pins, and not both. A CLOSED jumper means the
black cap is on both of the metal pins, and an OPEN jumper means the cap is on
only one (1) metal pin.
CLOSE OPEN
JP1
JP2
JP3
Furnace
HP
5 MIN 2 MIN
HARDWARE RESET BUTTON: A change to ANY of the jumper settings will not be
recognized by the thermostat until the white HARDWARE RESET button on the
circuit board is pressed.
F
C
JP1 (SYSTEM): [CLOSED = Furnace, default] This setting is used for the majority of all heating
systems that are not heat pumps. Examples for this setting would be: natural gas furnace, hot
water baseboard heat, and oil heat. [OPEN = Heat Pump] Use this setting if you have a heat
pump unit (which looks just like an outside air conditioning unit, but is used for both cooing and
heating).
CLOSED
OPEN
JP2 (DELAY): [CLOSED = 5 Minutes, default] This setting changes the length of time that the
system must remain either on or off before it will switch to the alternate on or off state. The
main purpose of this setting is to provide equipment protection by preventing brief or undesirable
frequent on/off cycling. [OPEN = 2 Minutes] This can be used to decrease the minimum amount
of time that occurs between cycles, and may be desired for hot water radiator systems to reduce
overshoot.
JP3 (SCALE): [CLOSED = Fahrenheit, default] All temperature values are displayed in F˚ degrees.
[OPEN = Celsius] This setting displays all temperature values in C˚ degrees.
JP4 (FAN): This option is located separately from the first three settings shown above.
[CLOSED = Gas, default] This setting lets the heating system itself control the blower fan
automatically. Types of systems that would typically use the “Gas” fan setting would be: natural
gas furnace, propane furnace, and oil furnace.
GAS
[OPEN = Elec] This setting runs the system’s blower fan when heat is called for, and is required
for systems that do not control their own fan while in HEAT mode. Heat pump systems, and units
with an electric heating element typically require this setting.
ELECT
3
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS:
HEAT / OFF / COOL, SYSTEM MODE SWITCH: Set this switch to HEAT to control your heating system, and COOL to control
your cooling system. The OFF position will disable both the heating and cooling units.
AUTO / ON, FAN SWITCH: When this switch is in AUTO, the blower fan (if present in your system) will automatically cycle
on and off by itself when heating or cooling is running. When in the ON position, the blower fan will run constantly with
or without a demand for heating or cooling, even in OFF mode.
UP AND DOWN BUTTONS: While in HEAT or COOL mode, you can use the UP and DOWN buttons to raise or lower the set
temperature. When the thermostat is powered up for the first time, it will use the default set temperatures of 68°F
(20°C) for Heat mode and 72°F (22°C) for Cool mode. NOTE: when you adjust the temperature using UP and DOWN
buttons, the change occurs immediately and you do not have to press the SAVE button to accept the changes.
SAVE BUTTON: Reducing the amount of heating and cooling energy you use will directly save you money. The SAVE
feature allows you to use just one button press to easily decrease the current set temperature by 5F (3°C) degrees while
in Heat mode (or raise the set temperature by 5°F (3°C) degrees while in Cool mode). When you leave the house, simply
press the SAVE button one time to put the thermostat into Save mode, and the word “SAVE” will be shown on the screen.
When you return home, press the SAVE button again to cancel the Save mode and return back to the previous set
temperature that you were using originally.
After Save mode has been started, you can adjust the energy-saving set temperature by using the UP and DOWN buttons
in either direction. Just like above, one more press on the SAVE button will cancel the Save mode and return back to the
original set temperature that was used prior to starting Save mode.
LCD DISPLAY BACKLIGHT: The display screen has a light that will assist viewing at nighttime, or in low lighting areas.
When any front panel button is pressed, the screen will light up for approximately 10 seconds. Any button presses that
occur while the backlight is on, will reset the 10 second timer, causing the screen to remain illuminated for an additional
10 seconds.
STATIC NOTICE: This thermostat is protected against normal minor static electric discharges, however to minimize the
risk of damaging the unit in extremely dry weather, please touch a grounded metal object before touching your
thermostat.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
ADVANCED FEATURES:
TEMPERATURE SWING: The amount of temperature variation between load-on and load-off is changed by adjusting the
swing setting. The default value for this thermostat is #4, and the adjustment range is from #1 to #9. A smaller swing
number makes the temperature control more precise and constant, and increases the number of cycles per hour. A larger
swing number will produce a greater variation between load-on and load-off events, and decreases the number of cycles
per hour.
To adjust the Swing setting: Set the thermostat to OFF mode using the System Mode switch, and hold down the SAVE
button for at least 5 seconds. When the screen changes to a single digit, this is the current Swing setting value and it
can be adjusted using the UP or DOWN buttons. The thermostat will return back to the normal Run mode screen if no
buttons are pressed for 4 seconds.
TEMPERATURE CALIBRATION: This thermostat is accurately calibrated at the factory, and in most cases alteration to this
setting should not be required. The Calibration feature allows you to manually offset the room temperature measurement
by as much as plus or minus 5°F (3°C) degrees from its original value. 0°F (0°C) is the default setting.
To adjust the Calibration setting: Set the thermostat to OFF mode using the System Mode switch, press both the UP and
DOWN together for at least 2 seconds. When the screen changes to a single digit, this is the current Calibration setting
value and it can be adjusted using the UP or DOWN buttons. The thermostat will return back to the normal Run mode
screen if no buttons are pressed for 4 seconds.
BATTERY REPLACEMENT:
This thermostat is powered by two “AA” Alkaline batteries. The batteries should be replaced AT LEAST once per year (or
sooner, if the “LOW BAT” battery symbol appears in the display screen). When the LO BAT symbol is shown, the
temperature digits will also display the word “Lo”. The batteries are located on the back of the circuit board, and can be
accessed by pulling the front portion of the thermostat straight outwards and removing it from the wall. When installing
new batteries, we recommend using only brand new Energizer® or DURACELL®, “AA” size alkaline batteries. Please
observe the polarity markings shown in the battery compartment to ensure proper installation. When finished, line up the
front of the thermostat to the base, and firmly press together.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL SUPPORT:
If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction
manual. If you require assistance, please contact our Technical Assistance department at 856-234-8803 during regular
business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday through Friday. You can also receive
the most common technical questions, and also permits you to email your questions to our technical support staff at your
convenience.
LIMITED WARRANTY:
If this unit fails because of defects in materials or workmanship within three years of the date of original purchase, LUX
will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow
installation instructions. Implied warranties are limited in duration to three years from the date of original purchase.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
Please return malfunctioning or defective units to the location from which the purchase was made, along with proof of
purchase. Please refer to “TECHNICAL ASSISTANCE” before returning thermostat. Purchaser assumes all risks and
liability for incidental and consequential damage resulting from installation and use of this unit. Some states do not
allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty
gives you specific legal rights and you may also have other rights, which vary from state to state. Applicable in the
U.S.A. and Canada only.
MERCURY WARNING AND RECYCLING NOTICE:
Mercury is considered to be a hazardous material. If this product is replacing a thermostat that contains mercury in a
sealed tube, contact your local waste management authority for instructions regarding recycling and proper disposal. It
may be unlawful in your state to place it in the trash.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING DIAGRAM NOTES:
1. The BOLD lines are what you should be connecting to the terminals on this new thermostat.
2. The DASHED lines are optional depending upon your system type.
3. In many cases, the thin lines shown as “SYSTEM COMMON” will not be visible at the thermostat
location, they are located with your heating and cooling equipment.
4. For Heat Pumps, use the “B” or “O” wire, NOT BOTH. Typically neither are used in a conventional
system.
5. If “Y” and “C” wires are both present, then “C” is a common wire.
6. If you have a “B” wire in your system which is used as a common wire, connecting it to the “B”
terminal on this thermostat may damage your system and/or the thermostat.
2, 3, 4 WIRES
1
HEATING ONLY (INCLUDING MILLIVOLT)
(2-WIRE HEAT USE “RH” & “W”)
Factory RH-RC Jumper Wire Installed
O
B
Y
W
RH
RC
G
W
R
G
F
RH
V
W1
4
FAN WIRE
MAY NOT BE
PRESENT IN
C
X
ALL SYSTEMS
COMMON
24V
POWER
HEATER
FAN
BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
3, 4 WIRES
2
1-STAGE, COOLING ONLY
Factory RH-RC Jumper Wire Installed
O
B
Y
W
RH
RC
G
Y
R
G
F
RC
V
Y1
6
C
X
COMMON
AIR
24V
POWER
FAN
CONDITIONER
BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
7
Download from Www.Somanuals.com. All Manuals Search And Download.
4, 5 WIRES
3
CONVENTIONAL (NON HEAT PUMP)
1-STAGE HEATING AND 1-STAGE COOLING
Factory RH-RC Jumper Wire Installed
O
B
Y
W
RH
RC
G
Y
W
R
G
F
RH
V
Y1
6
W1
4
C
X
COMMON
AIR
24V
POWER
HEATER
FAN
CONDITIONER
BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
4, 5 WIRES
SINGLE-STAGE HEAT PUMP SYSTEM
WITH NO AUX OR EMERGENCY HEAT
4
** Use “O” or “B”
Terminals, Never Both
ADD Y-W Jumper Wire
Factory RH-RC Jumper Wire
O
B
Y
W
RH
RC
G
O
B
Y
R
G
RC
V
Y1
6
F
C
X
COMMON
REVERSING
VALVE
HEAT
PUMP
24V
POWER
FAN
BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
5, 6 WIRES
5
1-STAGE HEATING AND 1-STAGE COOLING
WITH TWO SEPARATE 24V TRANSFORMERS
Factory RH-RC Jumper Wire REMOVED
O
B
Y
W
RH
RC
G
Y
W
RH
RC
G
Y1
6
W1
4
R
V
R
V
F
C
X
COMMON
AIR
CONDITIONER
24V HEAT
POWER
24V COOL
POWER
HEATER
FAN
BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
8