Details of LG Model Name(2002)  
3
4
5
6
7
8
9
1
2
-
Code  
1,2  
3
Type  
Code of Model  
Meaning  
Type of Airconditioner  
Chassis  
A~Z  
A~Z  
LS: LG Split Type Airconditioner  
Name of toll of Unit  
Ex. LS-R S R Chassis  
Cooling/Heating Capacity  
Ex. "09" 9,000Btu/h  
4,5  
6
Capacity(Btu/h)  
1~9  
1~9  
Electric Range  
Electric Standard  
1 115V/60Hz  
6 220~240V/50Hz  
2 220V/60Hz  
3 208~230V/60Hz  
5 200~220V/50Hz  
7 110V, 50/60Hz  
8 380~415V/50Hz  
9 380~415V/60Hz  
Basic  
Plasma Filter  
Auto Swing + Plasma Filter  
Telephone + LED Display  
A
0
1
2
3
4
5
6
7
8
7
Serial No.  
0~9  
A~Z  
B
C
D
E
F
G
H
J
Telephone + LCD Display  
Auto Swing + Plasma Filter + Telephone + LCD  
Low Ambient + Ambient/change  
Plasma Filter + Low Ambient + Ambient/change  
Internet  
Auto Swing + Plasma Filter + Oxygen Generator  
Auto Swing + Soft Start  
Auto Swing + Star Rating  
Auto Swing + Star Rating + Plasma Filter  
Auto Swing + Soft Start + Star Rating  
Auto Swing + Soft Start + Star Rating 4 + Plasma  
Auto Swing + Telephone + LCD  
Auto Swing + Telephone + LCD + Soft Start  
K
L
9
Z
Y
X
W
V
U
T
M
N
P
Q
R
S
HFC+AC HFC+DC  
8
Cooling/Heating  
A~Z  
UNIT  
R22  
HFC  
R22+AC INV.  
INV.  
INV.  
INDOOR  
BASIC  
OUTDOOR  
C/O  
C
H/P E/H+C/O E/H+H/P C/O  
H/P  
R
P
S
-
C/O  
V
H/P  
N
H/P  
H/P  
BASIC  
GOLD FIN  
GOLD FIN  
BASIC  
H
B
E
J
X
5
7
-
Y
6
8
-
F
M
Q
-
BASIC  
A
W
1
Y
T
U
PLASMA  
PLASMA  
GOLD FIN  
D
2
G
3
4
GOLD FIN  
K
L
-
-
-
-
9
LG/OEM Brand  
A~Z  
L: LG Brand  
G: 2nd LG Brand  
M: 1st OEM Brand  
N: 2nd OEM Brand  
-3-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Details of LG Model Name(2003)~  
1
2
-
3
4
5
6
7
8
9
10  
Code  
Type  
Code of Model  
Meaning  
L: Chang-won R22  
A: Chang-won R410A  
C: Chang-won R407C  
T: China  
1
Producing Center,  
Refrigerant  
A~Z  
N: India  
Z: Brazil  
D: Indonesia  
M: Mexico  
V: Vietnam  
S: Out Sourcing  
K: Turkey R22  
E: Turkey R410A  
H: Thailand  
2
3
Product Type  
A~Z  
A~Z  
S: Split Type Air Conditioner  
Cooling/Heating/Inverter  
C: Cooling only  
H: Heat pump  
V: AC Inverter C/O  
N: AC Inverter H/P  
Q: DC Inverter C/O  
W: DC Inverter H/P  
X: C/O + E/Heater  
Z: H/P + E/Heater  
4, 5  
6
Capacity  
0~9  
Cooling/Heating Capacity  
Ex. "09" 9,000 Btu/h  
Electric Range  
1~9  
A~Z  
1: 115V/60Hz,  
2: 220V/60Hz  
A: 220V, 50Hz, 3Phase  
B: 208~230V, 60Hz, 3Phase  
C: 575V, 50Hz, 3Phase  
D: 440~460, 60Hz, 3Phase  
E: 265V, 60Hz  
3: 208-230V/60Hz  
5: 200-220V/50Hz  
6: 220-240V/50Hz  
7: 110V, 50/60Hz  
8: 380-415V/50Hz  
9: 380-415V/60Hz  
F: 200V, 50/60Hz  
7
Chassis  
A~Z  
Name of Chassis of Unit  
Ex. LSP SP Chassis  
8
9
Look  
A~Z  
A~Z  
Look,  
Color (Artcool Model)  
Function  
Basic  
A
B
C
D
E
F
G
H
I
Basic+4Way  
Plasma Filter  
Plasma Filter+4 Way  
Tele+LCD  
Tele+LCD+Nano plasma+4Way  
Nano Plasma F+(A/changeove)+A/clean+Low A  
Nano Plasma F+(A/changeove)+A/clean+4way+Low A  
Tele+LED+4way  
Internet  
J
Plasma F+4Way+Oxy generator  
K
L
Nano Plasma F+(A/changeove)+A/clean  
Nano Plasma F+(A/changeove)+A/clean+4way  
Nano Plasma F+(A/changeove)+A/clean+PTC  
Nano Plasma F+(A/changeove)+Autoclean+4way+PTC  
Nano Plasma F+(A/changeove)+A/clean+4way+Low A+PTC  
Negative ION+A/Clean  
(Nano)Plasma+Negative ION+A/Clean  
4way+(Nano)Plasma F+Negative ION+Healthy dehumidification+A/Clean  
Nano Plasma F+4Way+(A/changeove)+A/clean+  
M
N
P
Q
R
S
T
U
10  
Serial No.  
1~9  
LG Model Development Serial No.  
* ARTCOOL COLOR  
R
W
B
Mirror  
White  
Blue  
D
M
C
Wood  
Metal  
Cherry  
-4-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functions  
Indoor Unit  
Operation ON/OFF by Remote controller  
Sensing the Room Temperature  
• Room temperature sensor. (THERMISTOR)  
Room temperature control  
• Maintains the room temperature in accordance with the Setting Temp.  
Starting Current Control  
• Indoor fan is delayed for 5 sec at the starting.  
Time Delay Safety Control  
• Restarting is inhibited for approx. 3 minutes.  
Indoor Fan Speed Control  
• High, Med, Low, CHAOS, JET COOL  
Operation indication Lamps (LED)  
--- Lights up in operation  
--- Lights up in Sleep Mode  
--- Lights up in Timer Mode  
--- Lights up in Defrost Mode (for Heating Model)  
OUTDOOR--- Lights up in compressor operation (for Cooling Model)  
PLASMA  
--- The function illustrates its dynamic mode  
by using a multiple lighting system.  
(
)
--- Linghts up in Telephone Control operation.  
PLASMA  
Soft Dry Operation Mode  
• The function will be operated while in any  
operation mode with selecting the function.  
• The function is to be stopped while it is  
operating with selecting the function.  
• Intermittent operation of fan at low speed.  
Sleep Mode Auto Control  
• The fan is switched to low(Cooling), med(Heating) speed.  
• The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.  
Defrost(Deice) control (Heating)  
• Both the indoor and outdoor fan stops dur-  
ing defrosting.  
Natural Air Control by CHAOS Logic  
• The fan is switched to intermittent or irregular operation  
Hot-start Control (Heating)  
The fan speed is automatically switched from high to low speed.  
• The indoor fan stops until the  
evaporator pipe temperature will be reached  
at 28°C.  
Airflow Direction Control  
• The louver can be set at the desired position or swing  
up and down automatically.  
-5-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control  
Operation ON/OFF  
Operation Mode Selection  
Cooling Operation Mode.(  
)
Auto Operation Mode.(  
)
(Cooling  
model only)  
(Heating  
model only)  
Healthy Dehumidification Operation Mode.  
(
)
Heating Operation Mode.(  
)
Fan Speed Selection  
(Low)  
(Med)  
(High)  
(CHAOS)  
Room, Temperature Display  
: (High:39°C  
Low:11°C)  
Temperature Setting  
LOW  
HIGH  
TEMPERATURE  
Down to 18°C  
Up to 30°C  
Down to 16°C  
Up to 30°C  
Cooling  
Heating  
JET COOL  
PLASMA(Optional)  
PLASMA  
Setting the Time or Timer  
Timer Selection  
ON  
OFF  
: OFF, ON, OFF  
ON  
Timer Setting  
SET  
Timer Cancel  
CANCEL  
: Cancel Sleep Mode, Timer ON or Timer OFF  
Sleep Operation  
: 1, 2, 3, 4, 5, 6, 7, Off Timer  
Airflow Direction Control  
Fan Operation Mode  
: Fan Operates without cooling or heating.  
Horizontal Airflow Direction Control Button(Optional)  
Reset  
-6-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control  
Operation ON/OFF  
Operation Mode Selection  
Cooling Operation Mode.(  
)
Auto Operation Mode.(  
)
(Cooling  
model only)  
(Heating  
model only)  
Healthy Dehumidification Operation Mode.  
(
)
Heating Operation Mode.(  
)
Fan Speed Selection  
(Low)  
(Med)  
(High)  
Room, Temperature Checking  
: (High:39°C  
Low:11°C)  
Temperature Setting  
LOW  
HIGH  
TEMPERATURE  
Down to 18°C  
Up to 30°C  
Down to 16°C  
Up to 30°C  
Cooling  
Heating  
JET COOL  
PLASMA(Optional)  
Setting the Time or Timer  
Timer Selection  
: OFF, ON, OFF  
ON  
ON  
OFF  
Timer Setting  
SET  
Timer Cancel  
CANCEL  
: Cancel Sleep Mode, Timer ON or Timer OFF  
Sleep Operation  
: 1, 2, 3, 4, 5, 6, 7, Off Timer  
Airflow Direction Control  
Air Circulation  
: Fan Operates without cooling or heating.  
Horizontal Airflow Direction Control Button(Optional)  
2nd F  
Reset  
-7-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product References  
LS-Q096BAG, LS-Q096ACG  
LS-Q096ACL, LS-Q096AAL  
LS-Q096ADG, LS-Q096ADL  
LS-Q096BDG, LS-Q096BDL  
LS-Q096AAG  
LS-Q096BBG, LS-Q096BEL  
LS-Q096AHG, LS-Q096ABL  
LS-Q096ABG, LS-Q096AEL  
LS-Q096ABM, LS-Q096AEM  
LS-Q096BEG  
LS-Q076BBG  
LS-Q082BAG/BAM  
LS-Q082AAL/ACG  
LS-Q082ACL/ACM  
LS-Q076BEL  
LS-Q076ABL  
LS-Q076ABG  
Model Name  
Unit  
LS-H096QNA0  
Item  
7,000  
7,300  
1.0  
9,000  
-
9,000  
9,300  
1.0  
8,000  
8,500  
Cooling Capacity  
Heating Capacity  
Moisture Removal  
Power Source  
Btu/h  
-
8,750  
1.0  
1.0  
1.0  
l/h  
1Ø, 220-240V, 50Hz 1Ø, 220-240V, 50Hz 1Ø, 220-240V, 50Hz  
1Ø, 220V, 60Hz  
1Ø, 220-240V, 50Hz  
Ø, V, Hz  
Indoor  
5.9  
20  
6
20  
36  
48  
900  
-
6
6
20  
36  
48  
650  
-
6
m3/min  
Air Circulation  
Noise Level  
Input  
Outdoor  
Indoor  
25  
25  
34  
36  
36  
dB (A)±3  
W
Outdoor  
48  
48  
48  
660  
640  
3.0  
2.9  
10.6  
3.3  
5
900  
870  
3.9  
3.8  
10  
950  
860  
4.2  
3.8  
8.9  
2.8  
8.4  
13.6  
Cooling  
Heating  
Cooling  
Heating  
Cooling  
4.0  
-
3.0  
-
Running  
Current  
E.E.R.  
C.O.P  
A
10  
-
10  
-
Btu/hW  
3.13  
5.7  
14.5  
Heating  
Indoor  
5.7  
14.5  
7.6  
18.7  
W
Motor Output  
Outdoor  
Indoor  
14  
Dimensions  
(W x H x D)  
824 x 260 x 155 824 x 260 x 155 824 x 260 x 155 824 x 260 x 155 824 x 260 x 155  
525 x 564 x 265 525 x 564 x 265 770 x 540 x 245 525 x 564 x 265 770 x 540 x 245  
mm  
Outdoor  
Indoor  
7
23  
7
23  
7
33  
7
23  
7
23  
kg  
g
Net. Weight  
Refrigerant  
Outdoor  
610(R22)  
O
530(R22)  
O
640(R22)  
O
630(R22)  
O
680(R22)  
O
Airflow Direction Control (Up & Down)  
L.C.D Wireless L.C.D Wireless L.C.D Wireless L.C.D Wireless L.C.D Wireless  
Remocon Type  
Liquid  
1/4" (6.35)  
3/8" (9.52)  
O
1/4" (6.35)  
3/8" (9.52)  
O
1/4" (6.35)  
3/8" (9.52)  
O
1/4" (6.35)  
3/8" (9.52)  
O
1/4" (6.35)  
3/8" (9.52)  
O
inch(mm)  
Service Valve  
Gas  
Sleeping Operation  
Drain Hose  
O
O
O
O
O
0.75mm2  
0.75mm2  
0.75mm2  
0.75mm2  
0.75mm2  
0.75mm2  
0.75mm2  
0.75mm2  
0.75mm2  
0.75mm2  
Connecting Cable  
Power Cord  
NOTE: Please refer to Label Quality on the product since this specification may be changed for improving  
performance  
-8-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LS-C096QLA0  
QNA0/QGL0  
Model Name  
Unit  
LS-C082QMA0/QNA0  
LS-H096QGL1  
Item  
9,000  
8,000  
9,000  
Cooling Capacity  
Heating Capacity  
Moisture Removal  
Power Source  
Btu/h  
-
-
9,300  
1.0  
1.0  
1.0  
l/h  
1Ø, 220-240V, 50Hz  
1Ø, 220V, 60Hz  
1Ø, 220-240V, 50Hz  
Ø, V, Hz  
Indoor  
6
6
6
m3/min  
Air Circulation  
Noise Level  
Input  
Outdoor  
Indoor  
20  
20  
25  
36  
36  
36  
dB (A)±3  
W
Outdoor  
48  
48  
48  
900  
650  
950  
Cooling  
Heating  
Cooling  
Heating  
Cooling  
-
-
860  
4.0  
3.0  
4.2  
Running  
Current  
E.E.R.  
C.O.P  
A
-
-
3.8  
10  
10  
9.5  
Btu/hW  
-
-
2.8  
Heating  
Indoor  
5.7  
7.6  
8.4  
W
Motor Output  
Outdoor  
Indoor  
14.5  
824 x 260 x 155  
525 x 564 x 265  
7
18.7  
824 x 260 x 155  
525 x 564 x 265  
7
13.6  
824 x 260 x 155  
770 x 540 x 245  
7
Dimensions  
(W x H x D)  
mm  
Outdoor  
Indoor  
kg  
g
Net. Weight  
Refrigerant  
Outdoor  
23  
23  
23  
530(R22)  
O
630(R22)  
O
680(R22)  
O
Airflow Direction Control (Up & Down)  
L.C.D Wireless  
1/4" (6.35)  
3/8" (9.52)  
O
L.C.D Wireless  
1/4" (6.35)  
3/8" (9.52)  
O
L.C.D Wireless  
1/4" (6.35)  
3/8" (9.52)  
O
Remocon Type  
Liquid  
inch(mm)  
Service Valve  
Gas  
Sleeping Operation  
Drain Hose  
O
O
O
0.75mm2  
0.75mm2  
0.75mm2  
0.75mm2  
0.75mm2  
0.75mm2  
Connecting Cable  
Power Cord  
NOTE: Please refer to Label Quality on the product since this specification may be changed for improving  
performance  
-9-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions  
(1) Indoor Unit  
H
D
W
Installation plate  
MODEL  
All Models  
DIM  
W
Unit  
mm  
824  
260  
155  
H
D
mm  
mm  
-10-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(2) Outdoor Unit  
L2  
W
L3  
Gas side  
(3-way valve)  
Liquid side  
(2-way valve)  
MODEL  
7k Heat Pump, 8k Cooling, 9k Cooling  
DIM  
W
unit  
mm  
mm  
mm  
mm  
mm  
mm  
mm  
mm  
564  
525  
265  
294  
66  
H
D
L1  
L2  
L3  
L4  
L5  
374  
17  
270  
-11-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(3) Outdoor Unit  
L2  
W
L3  
Gas side  
(3-way valve)  
Liquid side  
(2-way valve)  
MODEL  
unit  
9k Heat Pump  
DIM  
W
mm  
mm  
mm  
mm  
mm  
mm  
mm  
mm  
770  
540  
245  
285  
65  
H
D
L1  
L2  
L3  
L4  
L5  
518  
10  
100  
-12-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Refrigeration Cycle Diagram  
(1) Cooling Only Models  
INDOOR UNIT  
OUTDOOR UNIT  
LIQUID SIDE  
CAPILLARY TUBE  
HEAT  
HEAT  
EXCHANGE  
(EVAPORATOR)  
EXCHANGE  
(CONDENSER)  
GAS SIDE  
COMPRESSOR  
(2) Cooling & Heating Models  
INDOOR UNIT  
OUTDOOR UNIT  
CHECK VALVE  
(Heating Model only)  
LIQUID SIDE  
VALVE  
CAPILLARY TUBE  
HEAT  
HEAT  
EXCHANGE  
(EVAPORATOR)  
EXCHANGE  
(CONDENSER)  
GAS SIDE  
VALVE  
REVERSING  
VALVE  
ACCUMU  
LATOR  
(Heating Model Only)  
COOLING  
HEATING  
COMPRESSOR  
-13-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring Diagram  
(1) Indoor Unit  
1. LS-Q076ABL, LS-Q076BBG, LS-Q076BEL  
LS-Q096ABL, LS-Q096ABG, LS-Q066AHG  
LS-Q096AEL, LS-Q096BBG, LS-Q096ABM  
LS-Q096AEM, LS-H096QNA0, LS-Q096BEG  
2. LS-Q096AAG, LS-Q096AAL, LS-Q096ACG  
LS-Q096ADL, LS-Q096ADG, LS-Q096BAG  
LS-Q096BAG, LS-Q096BDG, LS-Q096BDL  
LS-Q082BAM, LS-C096QGL0, LS-C096QLA0,  
LS-C096QNA0, LS-H096QGL1  
3. LS-Q082BAG, LS-Q096ACL, LS-Q082AAL  
LS-Q082ACG, LS-Q082ACL, LS-Q082ACM  
LS-C082QMA0, LS-C082QNA0  
AC PWB ASM  
DC PWB ASM  
THERMISTOR  
AC PWB ASM.  
TRIAC  
DC PWB ASM.  
AC PWB ASM.  
TRIAC  
DC PWB ASM.  
THERMISTOR  
THERMISTOR  
OR  
BK  
OR  
BK  
GN/YL  
GN/YL  
MOTOR  
MOTOR  
STEP  
STEP  
STEP  
MOTOR  
MOTOR  
MOTOR  
TRIAC  
CN-MOTOR  
CN-MOTOR  
OR  
BK  
BR  
YL  
BR  
YL  
MOTOR  
STEP  
STEP  
MOTOR  
MOTOR  
SH-CAPA  
SH-CAPA  
STEP  
MOTOR  
CN-MOTOR  
CN-TAB1  
BR YL  
SH-CAPA  
RD  
BK  
RD  
BK  
AIR  
AIR  
H.V.  
T/BOARD  
CN-TAB  
H.V.  
T/BOARD  
CN-TAB  
CLEAN  
(PLASMA)  
CLEAN  
(PLASMA)  
ASM.  
ASM.  
T-BLOCK  
T-BLOCK  
BK  
BK  
BK  
BK  
RD  
BK  
BK  
BK  
BK  
BK  
AIR  
FUSE  
250V T2A  
H.V.  
S/W1  
S/W2  
S/W1  
S/W2  
4
3
CLEAN  
4
3
ASM  
4
3
(
)
PLASMA  
FUSE  
250V T2A  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
BK  
RY-COMP  
FUSE  
250V T2A  
RY-COMP  
BK  
BK  
RY-COMP  
SAFETY S/W1  
SAFETY S/W2  
GN/YL  
BK  
BK  
CN-DISP  
CN-DISP  
GN/YL  
RY-4WAY  
T/BLOCK  
CN-DISP  
RY-FAN  
DISPLAY PWB ASM.  
DISPLAY PWB ASM.  
SW(FORCE)  
DISPLAY PWB ASM  
TO OUTDOOR UNIT  
TO OUTDOOR UNIT  
TO OUTDOOR UNIT  
P/No : 3854A20238J  
P/No : 3854A20238H  
INDOOR WIRING DIAGRAM  
INDOOR WIRING DIAGRAM  
INDOOR WIRING DIAGRAM  
3854A20142B  
(2) Outdoor Unit  
1. LS-Q076ABL, LS-Q076ABG,  
LS-Q076BBG  
LS-Q076BEL  
2. LS-Q096AAG, LS-Q096AAL,  
LS-Q096ACG, LS-Q096ADL,  
LS-Q096ADG, LS-Q096ACL  
LS-Q096BAG, LS-Q096BDG,  
LS-Q096BDL LS-Q082BAG,  
LS-Q096ABM, LS-Q082AAL  
LS-Q082BAM, LS-Q082ACG,  
LS-Q082ACL, LS-Q082ACM  
LS-C082QMA0, LS-C082QNA0  
LS-C096QCL0, LS-C096QLA0  
LS-C096QNA0, LS-H096QGL1  
3. LS-Q096ABL, LS-Q096AEL,  
LS-Q096ABG, LS-Q096AHG,  
LS-Q096BBG, LS-Q096BEL  
LS-Q096ABM, LS-Q096AEM,  
LS-Q096BEG  
4. LS-H096QNA0, LS-H096QNA0  
BL  
BL  
PTC  
GN/YL  
FAN  
MOTOR  
COMP  
CAPACITOR  
CAPACITOR  
H
C
F
H
C
F
RD  
COMP  
RD  
RD  
COMP  
RD  
BL  
BL  
R
C
S
R
S
R
S
CAPACITOR  
BL  
BL  
BK  
BL  
H
C
F
BL  
RD BL YL  
C
C
GN/YL  
GN/YL  
BR RD BL  
BR  
BR  
BK(RD)  
RD  
BL  
YL  
OLP  
OLP  
FAN  
MOTOR  
FAN  
MOTOR  
BR(YL)  
YL  
BR  
1
BK  
YL  
1
2
3
BR  
BL GN/YL BK(RD)  
YL  
BR BL GN/YL BK RD  
BR BL GN/YL  
TERMINAL  
BLOCK  
(
)
(
2
)
N
1 L  
3
4
PILLAR  
TERMINAL  
PILLAR  
TERMINAL  
(
)
(
)
(
)
(
)
1 L 2 N  
3
4
1 L 2 N  
BR  
BL GN/YL  
BK RD  
BR BL GN/YL  
BLACK  
BR BL GN/YL BK RD  
BLACK GRAY  
TO INDOOR UNIT  
TO INDOOR UNIT  
TO INDOOR UNIT  
OUTDOOR WIRING DIAGRAM  
OUTDOOR WIRING DIAGRAM  
OUTDOOR WIRING DIAGRAM  
3854A30077D  
3854AR2262E  
3854AR2262F  
-14-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation Details  
1. MAIN UNIT FUNCTION  
• DISPLAY  
1) C/O Model  
Operation Indicator  
ON while in appliance operation, OFF while in appliance pause.  
Flashing while in disconnection or short in Thermistor. (3 sec off / 0.5 sec on)  
Sleep Timer Indicator  
ON while in sleep timer mode, OFF when sleep timer cancel or appliance operation pause.  
Timer Indicator  
ON while in timer mode (on/off), OFF when timer mode is completed or canceled.  
Comp. Running Incidator  
While in appliance operation, ON while in outdoor unit compressor running, OFF while in compressor off.  
2) H/P Model  
Operation Indicator  
ON while in appliance operation, OFF while in appliance pause.  
Flashing while in disconnection or short in Thermistor. (3 sec off / 0.5 sec on)  
Sleep Timer Indicator  
ON while in sleep timer mode, OFF when sleep timer cancel or appliance operation pause.  
Timer Indicator  
ON while in timer mode (on/off), OFF when timer mode is completed or canceled.  
Defrost Indicator  
OFF except when hot start during heating mode operation or while in defrost control.  
Cooling Mode Operation  
When the intake air temperature reaches 0.5°C below the setting temp, the compressor and the outdoor fan  
stop.  
When it reaches 0.5°C above the setting temp, they start to operate again.  
Compressor ON Temp  
Compressor OFF Temp  
Setting Temp+0.5°C  
Setting Temp-0.5°C  
While in compressor running, operating with the airflow speed set by the remote control. While in compressor  
not running, operating with the low airflow speed regardless of the setting.  
Healthy Dehumidification Mode  
When the dehumidification operation input by the remote control is received, the intake air temperature is  
detected and the setting temp is automatically set according to the intake air temperature.  
26°C Intake Air Temp  
25°C  
24°C Intake Intake Air Temp<26°C  
18°C Intake Intake Air Temp<24°C  
Intake Air Temp<18°C  
Intake Air Temp-1°C  
Intake Air Temp-0.5°C  
18°C  
-15-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
While in compressor off, the indoor fan repeats low airflow speed and pause.  
While the intake air temp is between compressor on temp. and compressor off temp., 10-min dehumidifica-  
tion operation and 4-min compressor off repeat.  
Compressor ON Temp.  
Setting Temp+0.5°C  
Compressor OFF Temp. Setting Temp-0.5°C  
In 10-min dehumidification operation, the indoor fan operates with the low airflow speed.  
Heating Mode Operation  
When the intake air temp reaches +3°…above the setting temp, the compressor is turned off. When below  
the setting temp, the compressor is turned on.  
Compressor ON Temp.  
Setting Temp.  
Compressor OFF Temp. Setting Temp.+3°C  
While in compressor on, the indoor fan is off when the indoor pipe temp. is below 20°C, when above 28°C , it  
operates with the low or setting airflow speed. When the indoor pipe temp is between 20°C and 28°C, it oper-  
ates with Super-Low(while in sleep mode, with the medium airflow speed).  
While in compressor off, the indoor fan is off when the indoor pipe temp is below 33°C, when above 35°C , it  
operates with the low airflow speed.  
If overloaded while in heating mode operation, in order to prevent the compressor from OLP operation, the  
outdoor fan is turned on/off according to the indoor pipe temp.  
While in defrost control, both of the indoor and outdoor fans are turned off.  
Defrost Control  
While in heating mode operation in order to protect the evaporator pipe of the outdoor unit from freezing,  
reversed to cooling cycle to defrost the evaporator pipe of the outdoor unit.  
After 40 min heating mode operation, at 4 min interval, whether to carry out defrost control or not and the time  
of defrost control are determined according to the following conditions.  
1) While in heating mode operation, the maximum of the indoor pipe temperature is measured and it is com-  
pared with the present indoor pipe temperature to get the difference of the indoor pipe temperatures (=the  
maximum temperature of indoor pipe ? the present temperature of indoor pipe), according to which, whether  
to carry out defrost control or not is determined.  
2) According to the need of defrost control shown above and the elapsed time of heating mode operation at that  
moment, the defrost control time is determined.  
3) When the determined time of defrost control is below 7 min, heating mode operation continues without carry-  
ing out defrost control. According to the procedure stated above, the determination is made again. When the  
defrost control time is 7 min or longer, defrost control is then carried out.  
While in defrost control, the minimum temp of the indoor pipe is measured and it is compared with the present  
temp of the indoor pipe to get the difference of the indoor pipe temperatures (=the present temperature of the  
indoor pipe ? the minimum temperature of the indoor pipe). When the difference is 5°C or higher, defrost con-  
trol is completed and heating mode operation is carried out.  
While in defrost control, if the defrost time determined before the start of defrost control is completed, defrost  
control stops and heating mode operation is carried out regardless of the above condition.  
When the indoor pipe temp is 42°C or above, defrost control is not carried out even if the condition is one of  
the defrost conditions above.  
While in defrost control, the compressor is on and the indoor fan, the outdoor fan, and the 4 way valve are off.  
-16-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fuzzy Operation (C/O Model)  
According to the temperature set by Fuzzy rule, when the intake air temp is 0.5°C or more below the setting  
temp, the compressor is turned off. When 0.5°C or more above the setting temp, the compressor is turned on.  
Compressor ON Temp  
Compressor OFF Temp  
Setting Temp + 0.5°C  
Setting Temp + 0.5°C  
At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the  
intake air temp at that time.  
26°C Intake Air Temp  
25°C  
24°C Intake Air Temp < 26°C  
22°C Intake Air Temp < 24°C  
18°C Intake Air Temp < 22°C  
Intake Air Temp<18°C  
Intake Air Temp + 1°C  
Intake Air Temp + 0.5°C  
Intake Air Temp  
18°C  
When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the  
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature  
automatically according to the Fuzzy rule.  
While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the  
temperature.  
Fuzzy Operation (H/P Model)  
When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since  
the operation off, the operation mode is selected.  
When determining the operation mode, the compressor, the outdoor fan, and the 4 way valve are off and only  
the indoor fan is operated for 15 seconds. Then an operation mode is selected according to the intake air  
temp at that moment as follows.  
24°C Inatake Air Temp  
21°C Inatake Air Temp<24°C  
Inatake Air Temp<21°C  
Fuzzy Operation for Cooling  
Fuzzy Operation for Dehumidification  
Fuzzy Operation for Heating  
If any of the operation modes among cooling / dehumidification / heating mode operations is carried out for 10  
sec or longer before Fuzzy operation, the mode before Fuzzy operation is operated.  
1) Fuzzy Operation for Cooling  
According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5°C or more below  
the setting temp, the compressor is turned off. When 0.5°C or more above the setting temp, the compressor  
is turned on.  
Compressor ON Temp  
Compressor OFF Temp  
Setting Temp +0.5°C  
Setting Temp + 0.5°C  
At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the  
intake air temp at that time.  
26°CIntake Air Temp  
25°C  
24°CIntake Air Temp<26°C  
22°CIntake Air Temp<24°C  
18°CIntake Air Temp<22°C  
Intake Air Temp<18°C  
Intake Air Temp + 1°C  
Intake Air Temp + 0.5°C  
Intake Air Temp  
18°C  
When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the  
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature  
automatically according to the Fuzzy rule.  
While in Fuzzy operation, the airflow speed of the indoor fan is automatically selected according to the tem-  
perature.  
-17-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2) Fuzzy Operation for Dehumidification  
According to the setting temperature selected by Fuzzy rule, when the intake air temp is 0.5°C or more below  
the setting temp, the compressor is turned off. When 0.5°C or more above the setting temp, the compressor  
is turned on.  
Compressor ON Temp  
Compressor OFF Temp  
Setting Temp + 0.5°C  
Setting Temp+0.5°C  
At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the  
intake air temp at that time.  
26°C Intake Air Temp  
25°C  
24°C Intake Air Temp<26°C  
22°C Intake Air Temp<24°C  
18°C Intake Air Temp<22°C  
Intake Air Temp<18°C  
Intake Air Temp+1°C  
Intake Air Temp+0.5°C  
Intake Air Temp  
18°C  
When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the  
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature  
automatically according to the Fuzzy rule.  
While in Fuzzy operation, the airflow speed of the indoor fan repeats the low airflow speed or pause as in  
dehumidification operation.  
3) Fuzzy Operation for Heating  
According to the setting temperature selected by Fuzzy rule, when the intake air temp is 3°C or more above  
the setting temp, the compressor is turned off. When below the setting temp, the compressor is turned on.  
Compressor ON Temp  
Compressor OFF Temp  
Setting Temp  
Setting Temp + 3°C  
At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the  
intake air temp at that time.  
20°CIntake Air Temp  
Intake Air Temp<20°C  
Intake Air Temp + 0.5°C  
20°C  
When the Fuzzy key (Temperature Control key) is input after the initial setting temperature is selected, the  
Fuzzy key value and the intake air temperature at that time are compared to select the setting temperature  
automatically according to the Fuzzy rule.  
While in Fuzzy operation, the airflow speed of the indoor fan is set to the high or the medium according to the  
intake air temperature and the setting temperature.  
Airflow Speed Selection  
The airflow speed of the indoor fan is set to high, medium, low, or chaos (auto) by the input of the airflow  
speed selection key on the remote control.  
On-Timer Operation  
When the set time is reached after the time is input by the remote control, the appliance starts to operate.  
The timer LED is on when the on-timer is input. It is off when the time set by the timer is reached.  
If the appliance is operating at the time set by the timer, the operation continues.  
-18-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Off-Timer Operation  
When the set time is reached after the time is input by the remote control, the appliance stops operating.  
The timer LED is on when the off-timer is input. It is off when the time set by the timer is reached.  
If the appliance is on pause at the time set by the timer, the pause continues.  
Off-Timer On-Timer Operation  
When the set time is reached after the on/off time is input by the remote control, the on/off-timer operation is  
carried out according to the set time.  
Sleep Timer Operation  
When the sleep time is reached after <1,2,3,4,5,6,7,0(cancel) hr> is input by the remote control while in appli-  
ance operation, the operation of the appliance stops.  
While the appliance is on pause, the sleep timer mode cannot be input.  
While in cooling mode operation, 30 min later since the start of the sleep timer, the setting temperature  
increases by 1°C. After another 30 min elapse, it increases by 1°C again.  
When the sleep timer mode is input while in cooling cycle mode, the airflow speed of the indoor fan is set to the  
low.  
When the sleep timer mode is input while in heating cycle mode, the airflow speed of the indoor fan is set to  
the medium.  
Chaos Swing Mode  
By the Chaos Swing key input, the upper/lower vane automatically operates with the Chaos Swing or they are  
fixed to the desired direction.  
While in Chaos Swing mode, the angles of cooling and heating cycle operations are different.  
< Cooling Mode >  
< Heating Mode >  
CLOSED  
CLOSED  
7°  
7°  
OPEN  
OPEN  
Chaos Natural Wind Mode  
When the Chaos Natural Wind mode is selected and then operated, the high, medium, or low speed of the air-  
flow mode is operated for 2~15 sec. randomly by the Chaos Simulation.  
-19-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Jet Cool Mode Operation (C/O Model)  
If the Jet Cool key is input at any operation mode while in appliance operation, the Jet Cool mode operates.  
In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.  
In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18°C  
When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.  
When the Jet Cool key is input, the upper/lower vanes are reset to those of the initial cooling mode and then  
operated in order that the air outflow could reach further.  
Jet Cool Mode Operation (H/P Model)  
While in heating mode or Fuzzy operation, the Jet Cool key cannot be input. When it is input while in the other  
mode operation (cooling, dehumidification, ventilation), the Jet Cool mode is operated.  
In the Jet Cool mode, the indoor fan is operated at super-high speed for 30 min at cooling mode operation.  
In the Jet Cool mode operation, the room temperature is controlled to the setting temperature, 18°C.  
When the sleep timer mode is input while in the Jet Cool mode operation, the Jet Cool mode has the priority.  
When the Jet Cool key is input, the upper/lower vanes are reset to those of the initial cooling mode and then  
operated in order that the air outflow could reach further.  
Forced Operation  
Operation procedures when the remote control can't be used.  
The operation will be started if the power button is pressed.  
If you want to stop operation, re-press the button.  
Heat pump Model  
Cooling Model  
Room Temp. 24°C 21°C Room Temp. < 24°C Room Temp. < 21°C  
Operating mode  
Indoor FAN Speed  
Setting Temperature  
Cooling  
High  
Cooling  
Healthy Dehumidification  
Heating  
High  
High  
High  
22°C  
22°C  
23°C  
24°C  
While in forced operation, the key input by the remote control has no effect and the buzzer sounds 10 times to  
indicate the forced operation.  
Test operation  
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room tem-  
perature and resets in 18±1 minutes.  
During test operation, if remote controller signal is received, the unit operates as remote controller sets.  
If you want to use this operation, open the front panel upward and Press the power button let it be pressed for  
about 3 seconds.  
If you want to stop the operation, re-press the button.  
Auto restart  
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate  
procedures automatically to the previous operating conditions.  
Air Cleaner Operation  
When an air cleaner function is selected during Air Conditioner operation  
- Plasma air cleaner function will be operated while in any operation mode with selecting the function.  
- The function is to be stopped while it is operating with selecting the function.  
When an air cleaner function is selected during operation off  
- The function will be only operated.  
When inlet grille of air conditioner is opened during plasma operation, High Voltage Generator(H.V.B) is to be  
stopped. When inlet grille of air conditioner is closed during plasma operation, High Voltage Generator(H.V.B)  
will be operated again.  
-20-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote Control Operation Mode  
When the remote control is selected by the slide switch on the main unit, the appliance operates according to  
the input by the remote control.  
Protection of the evaporator pipe from frosting  
If the indoor pipe temp is below 0°C in 7 min. after the compressor operates without any pause while in cool-  
ing cycle operation mode, the compressor and the outdoor fan are turned off in order to protect the indoor  
evaporator pipe from frosting.  
When the indoor pipe temp is 7°C or higher after 3 min. pause of the compressor, the compressor and the  
outdoor fan is turned on according to the condition of the room temperature.  
Buzzer Sounding Operation  
When the appliance-operation key is input by the remote control, the short "beep-beep-" sounds.  
When the appliance-pause key is input by the remote control, the long "beep" sounds.  
When a key is input by the remote control while the slide switch on the main unit of the appliance is on the  
forced operation position, the error sound "beep-beep-beep-beep-beep-" is made 10 times to indicate that the  
remote control signal cannot be received.  
-21-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Display Function  
1. Heating Model  
2. Cooling Model  
Operation Indicator  
Operation Indicator  
Cooling, Soft Dry, Fan, Heating  
Cooling, Soft Dry, Fan  
Sleep Timer Indicator  
Sleep Timer Indicator  
Sleep Mode  
Sleep Mode  
Timer Indicator  
Timer Indicator  
Timer Mode  
Timer Mode  
Compressor Indicator  
OUTDOOR  
PLASMA  
Defrost Indicator  
Hot-start, Defrost  
PLASMA Indicator  
PLASMA Indicator  
PLASMA  
PLASMA Mode  
PLASMA Mode  
Self-diagnosis Function  
Error  
Code  
Error Display LED  
(Indoor body operation LED)  
Error contents  
SVC check point  
Indoor room temperature  
(once)  
thermistor open/short  
Indoor pipe temperature  
thermistor open/short.  
Indoor Thermistor  
assembly check  
1
3sec  
3sec  
3sec  
-22-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
1. Installation of indoor, Outdoor unit  
Select a place so that the warm air and noise from the  
air conditioner do not disturb neighbors.  
1) Selection of the best location  
1. Indoor unit  
More than 10 cm  
More than 10 cm  
Do not have any heat or steam near the unit.  
Select a place where there are no obstacles in front of  
the unit.  
Make sure that condensation drainage can be conve-  
niently routed away.  
Do not install near a doorway.  
Ensure that the space around the left and right of the  
unit is more than "A". The unit should be installed as  
high on the wall as possible, allowing a minimum of  
"B" from ceiling.  
More than 70 cm  
2) Piping length and elevation  
Use a stud finder to locate studs to prevent unneces-  
sary damage to the wall.  
Standard Max.  
Max.  
Additional  
Pipe Size  
Capacity  
(Btu/h)  
Length Elevation Length Refrigerant  
GAS  
LIQUID  
(m)  
B (m)  
A (m)  
(g/m)  
3/8"(Ø9.52)  
1/2"(Ø12.7)  
1/2"(Ø12.7)  
1/4"(Ø6.35)  
1/4"(Ø6.35)  
1/4"(Ø6.35)  
4 or 7.5  
4 or 7.5  
4 or 7.5  
4 or 7.5  
4 or 7.5  
7.5  
7
15  
15  
30  
30  
30  
30  
30  
20  
20  
20  
20  
30  
30  
50  
More than "B"  
7k~14k  
7
15  
15  
15  
15  
15  
More than "A"  
18k~28k  
30k~38k  
5/8"(Ø15.88) 1/4"(Ø6.35)  
5/8"(Ø15.88) 3/8"(Ø9.52)  
5/8"(Ø15.88) 3/8"(Ø9.52)  
3/4"(Ø19.05) 3/8"(Ø9.52)  
7.5  
Indoor unit  
Outdoor unit  
More than 2.3m  
More than "B"  
A
A
CAUTION  
Indoor unit  
B
Outdoor unit  
B
Install the indoor unit on the wall where the height  
from the floors more than 2.3 meters.  
Clearance(cm)  
Grade  
I
A
B
5
12  
Outdoor unit  
7K~28K  
30K~38K  
10  
30  
A
Oil trap  
2. Outdoor unit  
Indoor unit  
If an awning is built over the unit to prevent direct sun-  
light or rain exposure, make sure that heat radiation  
from the condenser is not restricted.  
B
Ensure that the space around the back and sides is  
more than 10cm. The front of the unit should have  
more than 70cm of space.  
Do not place animals and plants in the path of the  
warm air.  
If case more than 5m  
CAUTION  
Capacity is based on standard length and maximum  
allowance length is on the basis of reliability.  
Oil trap should be installed every 5~7 meters.  
Take the air conditioner weight into account and select  
a place where noise and vibration are minimum.  
-23-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3) How to fix installation plate  
4) Drill a hole in the wall  
The wall you select should be strong and solid enough  
to prevent vibration  
Drill the piping hole with a ø70mm hole core drill. Drill  
the piping hole at either the right or the left with the  
hole slightly slanted to the outdoor side.  
1. Mount the installation plate on the wall with four  
type A screws. If mounting the unit on a concrete  
wall, use anchor bolts.  
WALL  
Mount the installation plate horizontally by aligning  
the centerline using a level.  
Indoor  
Outdoor  
Installation Plate  
Type "A" screw  
2. Measure the wall and mark the centerline. It is  
also important to use caution concerning the  
location of the installation plate-routing of the  
wiring to power outlets is through the walls typi-  
cally. Drilling the hole through the wall for piping  
connections must be done safely.  
C
Installation plate  
A
Ø70mm  
Ø70mm  
Left rear piping  
Right rear piping  
Distance (mm)  
CHASSIS  
(Grade)  
A
90  
45  
75  
0
B
C
80  
80  
80  
20  
210  
D
20  
20  
12  
40  
0
SJ  
SL, SK  
SQ  
20  
40  
12  
40  
0
SR  
ST  
105  
Installation plate  
C
E
A
Ø70mm  
Right rear piping  
Left rear piping  
Distance (mm)  
CHASSIS  
(Grade)  
A
B
C
-
D
E
SM  
SN  
180  
180  
115  
115  
115  
115  
50  
-
195  
-24-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Flaring Work and Connection of Piping  
4. Flaring work  
1) Flaring work  
Firmly hold copper pipe in a die in the dimension  
shown in the table above.  
Main cause for refrigerant leakage is due to defect in  
the flaring work. Carry out correct flaring work using the  
following procedure.  
Handle  
Yoke  
1. Cut the pipes and the cable.  
Bar  
Bar  
Use the piping kit accessory or pipes purchased locally.  
Measure the distance between the indoor and the  
outdoor unit.  
Cone  
Cut the pipes a little longer than the measured  
distance.  
Cut the cable 1.5m longer than the pipe length.  
Copper pipe  
Clamp handle  
Red arrow mark  
Carry out flaring work using flaring tool as shown  
below.  
Copper  
pipe  
Slanted Uneven Rough  
90°  
Outside diameter  
mm  
inch  
1/4  
3/8  
1/2  
5/8  
3/4  
mm  
0~0.5  
0~0.5  
0~0.5  
0~1.0  
1.0~1.3  
Ø6.35  
Ø9.52  
Ø12.7  
Ø15.88  
Ø19.05  
2. Burr removal  
Completely remove all burrs from the cut cross sec-  
tion of pipe/tube.  
Put the end of the copper tube/pipe in a downward  
direction as you remove burrs in order to avoid drop-  
ping burrs into the tubing.  
5. Check  
Compare the flared work with figure below.  
If flare is noted to be defective, cut off the flared sec-  
tion and re-flare it.  
Pipe  
Reamer  
Smooth all round  
Inside is shiny without scratches  
Point down  
= Improper flaring =  
3. Putting nut on  
Remove flare nuts attached to indoor and outdoor  
unit, then put them on pipe/tube having completed  
burr removal.  
Inclined Surface Cracked Uneven  
damaged  
thickness  
Even length  
all round  
(not possible to put them on after flaring work)  
Flare nut  
Copper tube  
-25-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Tape the tubing, drain hose, and the connecting  
cable. Be sure that the drain hose is located at the  
lowest side of the bundle. Locating at the upper  
side can cause drain pan to overflow inside the  
unit.  
2) Connection of piping Indoor  
Preparing the indoor unit's piping and drain hose for  
installation through the wall.  
Remove the plastic tubing retainer(see illustration  
below) and pull the tubing and drain hose away from  
chassis.  
Replace the plastic tubing holder in the original posi-  
tion.  
Loop  
Gas side  
Connecting  
piping  
cable  
Liquid side  
piping  
Tubing holder  
Drain hose  
CAUTION  
NOTE: If the drain hose is routed inside the room,  
insulate the hose with an insulation material* so that  
dripping from "sweating"(condensation) will not damage  
furniture or floors.  
When install, make sure  
that the remaining parts  
must be removed clearly  
so as not to damage the  
piping and drain hose,  
especially power cord  
and connecting cable.  
*Foamed polyethylene or equivalent is recommended.  
4. Indoor unit installation  
Hook the indoor unit onto the upper portion of the  
installation plate.(Engage the two hooks of the rear  
top of the indoor unit with the upper edge of the instal-  
lation plate.) Ensure that the hooks are properly seat-  
ed on the installation plate by moving it left and right.  
For right rear piping  
1. Route the indoor tubing and the drain hose in the  
direction of rear right.  
Connecting  
cable  
Drain hose  
Press the lower left and right sides of the unit against  
the installation plate until the hooks engage into their  
slots(clicking sound).  
4. Connecting the pipings to the indoor unit and drain  
hose to drain pipe.  
Drain hose  
Align the center of the pipes and sufficiently tighten  
the flare nut by hand.  
2. Insert the connecting cable into the indoor unit  
from the outdoor unit through the piping hole.  
Do not connect the cable to the indoor unit.  
Make a small loop with the cable for easy  
connection later.  
Indoor unit tubing  
Flare nut Pipes  
-26-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tighten the flare nut with a wrench.  
Wrap the area which accommodates the rear piping  
housing section with vinyl tape.  
Open-end wrench (fixed)  
Indoor  
unit pipe  
Connection  
pipe  
Flare nut  
Vinyl tape  
(wide)  
Wrap with vinyl tape  
Connection pipe  
Wrench  
Connecting cable  
Indoor unit tubing  
Outside diameter  
Torque  
Pipe  
.
mm  
inch  
1/4  
3/8  
1/2  
5/8  
3/4  
kg m  
Ø6.35  
Ø9.52  
Ø12.7  
Ø15.88  
Ø19.05  
1.8  
4.2  
5.5  
6.6  
6.6  
Vinyl tape(narrow)  
Bundle the piping and drain hose together by wrap-  
ping them with vinyl tape for enough to cover where  
they fit into the rear piping housing section.  
When extending the drain hose at the indoor unit,  
Wrap with vinyl tape  
Pipe  
install the drain pipe.  
Drain pipe  
Vinyl tape(wide)  
Drain hose  
Indoor unit drain hose  
For left rear piping  
Vinyl tape(narrow)  
Adhesive  
1. Route the indoor tubing and the drain hose to the  
required piping hole position.  
5. Wrap the insulation material around the connecting  
portion.  
Overlap the connection pipe insulation material and  
the indoor unit pipe insulation material. Bind them  
together with vinyl tape so that there is no gap.  
Plastic bands  
Insulation material  
2. Insert the piping, drain hose, and the connecting  
cable into the piping hole.  
Connecting cable  
Drain pipe  
-27-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Insert the connecting cable into the indoor unit.  
Don't connect the cable to the indoor unit.  
Make a small loop with the cable for easy connection  
later.  
Outside diameter  
mm  
Torque  
.
inch  
1/4  
3/8  
1/2  
5/8  
3/4  
kg m  
Ø6.35  
Ø9.52  
1.8  
4.2  
5.5  
6.6  
6.6  
Ø12.7  
4. Tape the drain hose and the connecting cable.  
Connecting cable  
Ø15.88  
Ø19.05  
When extending the drain hose at the indoor unit,  
install the drain pipe.  
Drain hose  
Indoor unit drain hose  
5. Indoor unit installation  
Hang the indoor unit from the hooks at the top of the  
installation plate.  
Vinyl tape (narrow)  
Adhesive  
Insert the spacer etc. between the indoor unit and the  
installation plate and separate the bottom of the  
indoor unit from the wall.  
7. Wrap the insulation material around the con-  
necting portion.  
Overlap the connection pipe heat insulation and the  
indoor unit pipe heat insulation material. Bind them  
together with vinyl tape so that there is no gap.  
Indoor unit  
Spacer  
Plastic bands  
Insulation material  
Installation plate  
8cm  
6. Connecting the pipings to the indoor unit and the  
drain hose to drain pipe.  
Wrap the area which accommodates the rear piping  
Align the center of the pipes and sufficiently tighten  
the flare nut by hand.  
housing section with vinyl tape.  
Indoor  
unit piping  
Connection  
pipe  
Vinyl tape  
(wide)  
Wrap with vinyl tape  
Pipe  
Indoor unit tubing  
Flare nut Pipes  
Tighten the flare nut with a wrench.  
Open-end wrench (fixed)  
Vinyl tape(narrow)  
Connecting cable  
Flare nut  
Connection pipe  
Wrench  
Indoor unit tubing  
-28-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bundle the piping and drain hose together by wrap-  
ping them with cloth tape over the range within which  
they fit into the rear piping housing section.  
3) Connection of the pipes-Outdoor  
1. Align the center of the pipings and sufficiently  
tighten the flare nut by hand.  
Pipe  
Drain hose  
Vinyl tape(narrow)  
Wrap with  
vinyl tape(wide)  
8. Reroute the pipings and the drain hose across the  
back of the chassis.  
2. Finally, tighten the flare nut with torque wrench  
until the wrench clicks.  
When tightening the flare nut with torque wrench,  
ensure the direction for tightening follows the arrow on  
the wrench.  
Outside diameter  
Torque  
.
mm  
inch  
1/4  
3/8  
1/2  
5/8  
3/4  
kg m  
Piping for  
passage through  
piping hole  
Ø6.35  
Ø9.52  
1.8  
4.2  
5.5  
6.6  
6.6  
Ø12.7  
9. Set the pipings and the drain hose to the back of  
the chassis with the tubing holder.  
Ø15.88  
Ø19.05  
Hook the edge of tubing holder to tap on chassis and  
push the bottom of tubing holder to be engaged at the  
bottom of chassis.  
Outdoor unit  
Gas side piping  
(Bigger diameter)  
Liquid side  
piping  
(Smaller  
diameter)  
Tubing holder  
Torque wrench  
LS-Q096ABL  
10. Indoor unit installation  
Remove the spacer.  
Ensure that the hooks are properly seated on the  
installation plate by moving it left and right.  
Gas side piping  
(Bigger Dia.)  
Outdoor unit  
Connecting  
cable  
Liquid side piping  
(Smaller Dia.)  
Torque wrench  
Drain hose  
Press the lower left and right sides of the unit against  
the installation plate until the hooks engage into their  
slots(clicking sound).  
LS-Q096AAL  
-29-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Connecting The Cable Between Indoor Unit and Outdoor Unit  
1) Connect the cable to the Indoor unit.  
Connect the cable to the indoor unit by connecting the wires to the terminals on the control board in  
dividually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and  
the terminal No. are the same as those of the indoor unit.)  
The earth wire should be longer than the common wires.  
CAUTION  
When installing, refer to the circuit diagram on the  
Control Box of Indoor Unit.  
When installing, refer to the wiring diagram on the  
Control Cover Inside Outdoor Unit.  
The power cord connected to the "A" unit should be  
complied with the following specifications  
(Type "B" approved by HAR or SAA).  
CAUTION  
The above circuit diagram is subject to change with-  
(mm2)  
NORMAL  
CROSS  
-SECTIONAL  
AREA  
Grade  
24k~28k 30k, 32k 36k, 38k  
out notice.  
5k~9K 12k~14k  
18k  
1.5  
Be sure to connect wires according to the wiring dia-  
0.75  
1.0  
2.5  
2.5  
5.5  
gram.  
Unit(A)  
Indoor  
Indoor  
Indoor  
Indoor  
Outdoor Outdoor  
Connect the wires firmly, so that not to be pulled out  
easily.  
Cable Type(B) H05VV-F H05VV-F H05VV-F H05VV-F H05RN-F H05RN-F  
Connect the wires according to color codes by refer-  
ring the wiring diagram.  
The power connecting cable connected to the indoor  
and outdoor unit should be complied with the following  
specifications  
(Type "B" approved by HAR or SAA).  
CAUTION  
If a power plug is not to be used, provide a circuit breaker  
between power source and the unit as shown below.  
Main power source  
NORMAL  
CROSS-SECTIONAL  
(mm2)  
AREA 0.75mm2  
NORMAL  
CROSS  
-SECTIONAL  
AREA  
Grade  
Circuit Breaker  
Use a circuit  
breaker or time  
delay fuse.  
Air  
5k~9k 12k~14k  
18k  
24k~28k  
2.5  
Conditioner  
0.75  
1.0  
1.5  
Cable Type(B) H07RN-F H07RN-F H07RN-F H07RN-F  
(mm2)  
Grade  
NORMAL CROSS  
-SECTIONAL AREA  
30k, 32k  
0.75  
36k, 38k  
0.75  
Cable Type(B) H07RN-F H07RN-F  
-30-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2) Connect the cable to the outdoor unit  
Outdoor unit  
Terminal block  
(Pillar terminal)  
1. Remove the control cover from the unit by loos-  
ening the screw.  
Connecting  
cable  
Connect the wires to the terminals on the control  
board individually.  
Holder for  
connecting  
cable  
Over  
5mm  
2. Secure the cable onto the control board with the  
cord clamp.  
Cover control  
3. Refix the control cover to the original position  
with the screw.  
LS-Q096AAL  
4. Use a recognized circuit breaker "A"  
between the power source and the unit.  
A disconnecting device to adequately disconnect  
all supply lines must be fitted.  
Outdoor unit  
Terminal block  
(Pillar terminal)  
Over 5mm  
Holder for  
power supply  
cord  
Grade  
Circuit  
Breaker  
(A)  
7k~14k  
18k  
24k~28k 30k, 32k 36k, 38k  
Cover control  
15  
20  
30 30 40  
Connecting cable  
LS-Q096ABL  
CAUTION  
After the confirmation of the above conditions, prepare the wiring as follows:  
1) Never fail to have an individual power circuit specifically for the air conditioner. As for the method of  
wiring, be guided by the circuit diagram posted on the inside of control cover.  
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from  
vibrations to which the unit is subjected during the course of transportation. Check them and make  
sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.)  
3) Specification of power source.  
4) Confirm that electrical capacity is sufficient.  
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on  
the name plate.  
6) Confirm that the cable thickness is as specified in the power source specification.  
(Particularly note the relation between cable length and thickness. (Refer to page 30))  
7) Always install an earth leakage circuit breaker in a wet or moist area.  
8) The following would be caused by voltage drop.  
Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the normal  
function of the overload.  
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and have an  
air gap contact separation of at least 3mm in each active(phase) conductors.  
-31-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Checking the Drainage and Forming the Pipings  
1) Checking the drainage  
2) Form the piping  
1. To remove the front panel from the indoor unit.  
Set the air direction louvers up-and-down to the posi-  
tion(horizontally) by hand.  
1. Form the piping by wrapping the connecting por-  
tion of the indoor unit with insulation material and  
secure it with two kinds of vinyl tapes.  
Remove the securing screws that retain the front pan-  
el. Pull the lower left and right sides of the grille  
toward you and lift it off.  
If you want to connect an additional drain hose, the  
end of the drain outlet should be routed above the  
ground. Secure the drain hose appropriately.  
2. In cases where the outdoor unit is installed below  
the indoor unit perform the following.  
Tape the piping, drain hose and connecting cable from  
down to up.  
Secure the tapped piping along the exterior wall using  
saddle or equivalent.  
Pull the right and  
the left side.  
Seal small openings  
around pipings with a  
gum type sealer.  
2. To check the drainage.  
Pour a glass of water on the evaporator.  
Ensure the water flows through the drain hose of the  
indoor unit without any leakage and goes out the drain  
exit.  
Taping  
Taping  
Drain hose  
Drain  
hose  
Pipings  
Pipings  
Connecting  
cable  
Connecting  
cable  
LS-Q096AAL LS-Q096ABL  
Trap is required to prevent water  
from entering into electrical parts.  
3. In cases where the Outdoor unit is installed above  
the Indoor unit perform the following.  
Tape the piping and connecting cable from down to up.  
Secure the taped piping along the exterior wall. Form  
a trap to prevent water entering the room.  
3. Drain piping  
The drain hose should point downward for easy drain  
Fix the piping onto the wall by saddle or equivalent.  
flow.  
Seal a small opening  
around the pipings  
with gum type sealer.  
Downward slope  
Trap  
Do not make drain piping.  
Accumulated  
Do not raise  
drain water  
Tip of drain hose  
dipped in water  
Air  
Less than  
50mm gap  
Trap  
Water  
leakage  
Water  
leakage  
Water  
leakage  
Waving  
Ditch  
-32-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Test Running  
1. Check that all tubing and wiring have been properly  
connected.  
Intake temperature  
2. Check that the gas and liquid side service valves are  
fully open.  
Discharge air  
1. Prepare remote control  
1. Remove the battery cover  
by pulling it according to the  
arrow direction.  
Discharge  
temperature  
2. Insert new batteries making  
sure that the (+) and () of  
battery are installed correctly.  
3. Reattach the cover by  
pushing it back into position.  
4. For reference; the gas side pressure of optimum con-  
dition is as below.(Cooling)  
Outside ambient  
TEMP.  
The pressure of the gas side  
service valve.  
Refrigerant  
R-22  
35°C (95°F)  
4~5kg/cm2G(56.8~71.0 P.S.I.G.)  
NOTE:  
Use 2 AAA(1.5volt) batteries. Do not use recharge-  
able batteries.  
Remove the batteries from the remote control if the  
system is not going to be used for a long time.  
NOTE: If the actual pressure is higher than shown, the  
system is most likely over-charged, and charge  
should be removed. If the actual pressure are  
lower than shown, the system is most likely  
undercharged, and charge should be added.  
The air conditioner is now ready for use.  
2. Settlement of outdoor unit  
Anchor the outdoor unit with a bolt and nut(ø10mm)  
tightly and horizontally on a concrete or rigid mount.  
When installing on the wall, roof or rooftop, anchor the  
mounting base securely with a nail or wire assuming  
the influence of wind and earthquake.  
PUMP DOWN  
This is performed when the unit is to be relocated  
or the refrigerant circuit is serviced.  
In the case when the vibration of the unit is conveyed  
to the hose, secure the unit with an anti-vibration  
bushing.  
Pump Down means collecting all refrigerant in the  
outdoor unit without loss in refrigerant gas.  
CAUTION:  
Be sure to perform Pump Down procedure with the  
unit cooling mode.  
Bolt  
Pump Down Procedure  
1. Connect a low-pressure gauge manifold hose to  
the charge port on the gas side service valve.  
2. Open the gas side service valve halfway and purge  
the air from the manifold hose using the refrigerant  
gas.  
Tubing connection  
3. Evaluation of the performance  
Operate unit for 15~20 minutes, then check the system  
refrigerant charge:  
3. Close the liquid side service valve(all the way in).  
4. Turn on the unit's operating switch and start the  
cooling operation.  
1. Measure the pressure of the gas side service valve.  
2. Measure the temperature of the intake and discharge  
of air.  
3. Ensure the difference between the intake tempera-  
ture and the discharge is more than 8°C(46°F) (Cool-  
ing) or (Heating).  
5. When the low-pressure gauge reading becomes 1  
to 0.5kg/cm2 G(14.2 to 7.1 P.S.I.G.), fully close the  
gas side valve stem and then quickly turn off the  
unit. At that time, Pump Down has been completed  
and all refrigerant gas will have been collected in  
the outdoor unit.  
-33-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
Name and Function-Remote Control  
The remote control transmits the signals to the system.  
START/STOP BUTTON  
Operation starts when this button is pressed and stops  
when the button is pressed again.  
1
Remote Control  
OPERATION MODE SELECTION BUTTON  
Used to select the operation mode.  
2
3
4
Signal transmitter  
ROOM TEMPERATURE SETTING BUTTONS  
Used to select the room temperature.  
INDOOR FAN SPEED SELECTOR  
Used to select fan speed in four steps  
low, medium, high and CHAOS.  
JET COOL  
5
6
Used to start or stop the speed  
cooling. (Speed cooling operates  
super high fan speed in cooling mode.)  
5
4
6
1
CHAOS SWING BUTTON  
Used to stop or start louver movement and set the  
desired up/down airflow direction.  
3
ON  
OFF  
7
8
9
2
10  
11  
12  
13  
ON/OFF TIMER BUTTONS  
Used to set the time of starting and stopping operation.  
7
8
SET  
CANCEL  
TIME SETTING BUTTONS  
Used to adjust the time.  
PLASMA  
TIMER SET/CANCEL BUTTONS  
Used to set the timer when the desired time is obtained  
and to cancel the Timer operation.  
15  
14  
9
SLEEP MODE AUTO BUTTON  
Used to set Sleep Mode Auto operation.  
Flip-up door  
(opened)  
10  
11  
AIR CIRCULATION BUTTON  
Used to circulate the room air without cooling or heat-  
ing.  
Operation Mode  
ROOM TEMPERATURE CHECKING BUTTON  
Used to check the room temperature.  
Cooling Operation  
12  
PLASMA(OPTION)  
Used to start or stop the plasma-purification function.  
Auto Operation  
13  
14  
15  
Healthy Dehumidification Operation  
RESET BUTTON  
Used prior to resetting time or after replacing batteries.  
Heating Operation  
HORIZONTAL AIRFLOW DIRECTION CONTROL BUT-  
TON (NOT ON ALL MODELS)  
Cooling Model( ), Heat Pump Model(  
)
Used to set the desired horizontal airflow direction.  
-34-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Name and Function-Remote Control  
The remote control transmits the signals to the system.  
START/STOP BUTTON  
Operation starts when this button is pressed and stops  
when the button is pressed again.  
1
Remote Control  
OPERATION MODE SELECTION BUTTON  
Used to select the operation mode.  
2
3
4
Signal transmitter  
ROOM TEMPERATURE SETTING BUTTONS  
Used to select the room temperature.  
INDOOR FAN SPEED SELECTOR  
Used to select fan speed in four steps low, medium, high  
and CHAOS.  
JET COOL  
5
6
Used to start or stop the speed cooling. (Speed cooling  
operates super high fan speed in cooling mode.)  
5
6
1
CHAOS SWING BUTTON  
Used to stop or start louver movement and set the desired  
up/down airflow direction.  
3
ON/OFF TIMER BUTTONS  
Used to set the time of starting and stopping operation.  
4
7
8
9
10  
9
2
7
CANCEL  
SET  
TIME SETTING BUTTONS  
Used to adjust the time.  
ON  
OFF  
11  
8
12  
TIMER SET/CANCEL BUTTON  
Used to set the timer when the desired time is obtained  
and to cancel the Timer operation.  
13  
14  
16  
15  
SLEEP MODE AUTO BUTTON  
Used to set Sleep Mode Auto operation.  
10  
11  
AIR CIRCULATION BUTTON  
Used to circulate the room air without cooling or heating.  
Flip-up door  
(opened)  
ROOM TEMPERATURE CHECKING BUTTON  
Used to check the room temperature.  
12  
13  
14  
Operation Mode  
PLASMA(OPTIONAL)  
Used to start or stop the plasma-purification function.  
Cooling Operation  
HORIZONTAL AIRFLOW DIRECTION CONTROL  
BUTTON (NOT ON ALL MODELS)  
Auto Operation  
Used to set the desired horizontal airflow direction.  
Healthy Dehumidification Operation  
RESET BUTTON  
Used prior to resetting time or after replacing batteries.  
15  
16  
Heating Operation  
2nd F Button  
Used prior to using modes printed in blue at the bottom of  
buttons.  
Cooling Model( ), Heat Pump Model(  
)
-35-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disassembly of the parts (Indoor unit)  
Warning :  
Disconnect the unit from power supply before making  
any checks.  
Be sure the power switch is set to “OFF”.  
To remove the Grille from the Chassis.  
• Set the up-and-down air discharge louver to open  
position (horizontally) by finger pressure.  
• Remove the securing screws.  
To remove the Grille, pull the lower left and right  
side of the grille toward you (slightly tilted) and lift it  
straight upward.  
Display  
P.C.B  
Conductor  
1. Before removing the control box, be sure to  
take out the wire screwed at the other end.  
Sensor  
Conductor  
Motor  
Conductor  
Step Motor  
Conductor  
Earth  
Conductor  
Earth  
Conductor  
-36-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. To remove the Control Box.  
Remove securing screws.  
Pull the control box out from the chassis careful-  
ly.  
Caution label  
3. To remove the Discharge Grille.  
Unhook the discharge grille and pull the dis-  
charge grille out from the chassis carefully.  
4. To remove the Evaporator.  
Remove 3 screws securing the evaporator(at the  
left 2EA in the Eva Holder, at the right 1EA).  
Caution label  
When repair, do not damage the Caution  
label.  
-37-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Unhook the tab on the right inside of the chassis  
at the same time, slightly pull the evaporator  
toward you until the tab is clear of the slot.  
5. To remove the Motor Cover  
Remove 2 securing screw.  
Pull the motor cover out from the chassis  
carefully.  
Motor cover  
6. To remove the Cross-Flow Fan  
Loosen the screw securing the cross-flow fan to  
the fan motor (do not remove).  
Lift up the right side of the cross-flow fan and the  
fan motor, separate the fan motor from the  
cross-flow fan.  
Remove the left end of the cross-flow fan from  
the self-aligning bearing.  
-38-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-way, 3-way Valve  
2-way Valve (Liquid Side)  
3-way Valve (Gas Side)  
Valve cap  
Hexagonal wrench (4mm)  
Open position  
Closed position  
Flare nut  
Flare nut  
Open position  
Closed position  
Pin  
To  
To  
piping  
piping  
Service  
port cap  
Service  
port  
connection  
connection  
To outdoor unit  
To outdoor unit  
Works  
Shaft position  
Shaft position  
Service port  
Closed  
(with valve cap)  
Closed  
(with valve cap)  
Closed  
(with cap)  
Shipping  
Air purging  
Open  
Closed  
Open  
1.  
(Installation)  
(counter-clockwise)  
(clockwise)  
(push-pin or with  
vacumm pump)  
Open  
(with valve cap)  
Open  
(with valve cap)  
Closed  
(with cap)  
Operation  
Closed  
(clockwise)  
Open  
Open  
Pumping down  
(Transfering)  
(counter-clockwise) (connected manifold  
gauge)  
2.  
3.  
4.  
Open  
Open  
Open  
Open  
(with charging  
cylinder)  
Evacuation  
(Servicing)  
Open  
Open  
(with charging  
cylinder)  
Gas charging  
(Servicing)  
Open  
Pressure check  
(Servicing)  
(with charging cylinder)  
Open  
Open  
Open  
Open  
5.  
6.  
Open  
Gas releasing  
(Servicing)  
(with charging cylinder)  
-39-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Air purging  
Required tools : hexagonal wrench, adjustable  
wrench, torque wrenches, wrench to  
hold the joints, and gas leak detec-  
tor.  
The air in the indoor unit and in the piping must be  
purged. If air remains in the refrigeration pipes, it will  
affect the compressor, reduce to cooling capacity, and  
could lead to a malfunction.  
The additional gas for air purging has been charged  
in the outdoor unit.  
However, if the flare connections have not be done  
correctly and there gas leaks, a gas cylinder and the  
charge set will be needed.  
Liquid side  
Indoor unit  
Open  
Outdoor unit  
2-way  
valve  
Gas side  
Clsed  
3-way  
valve  
Service port nut:  
Be sure, using a torque wrench to tighten the service port nut (after using the service port), so that it prevents the  
gas leakage from the refrigeration cycle.  
*
CAUTION : Do not leak the gas in the air during Air purging.  
Procedure  
(6) Set the 3-way valve to the back seat.  
(1) Recheck the piping connections.  
(7) Mount the valve stem nuts to the 2-way and 3-  
way valves.  
(2) Open the valve stem of the 2-way valve coun-  
terclockwise approximately 90°, wait 10 sec-  
onds, and then set it to closed position.  
Be sure to use a hexagonal wrench to operate  
the valve stem.  
(8) Check for gas leakage.  
At this time, especially check for gas leakage  
from the 2-way and 3-way valves stem nuts,  
and from the service port nut.  
(3) Check for gas leakage.  
Check the flare connections for gas leakage.  
Caution  
(4) Purge the air from the system.  
If gas leakage are discovered in step (3) above,  
take the following mesures :  
Set the 2-way valve to the open position and  
remove the cap from the 3-way valves service  
port.  
Using the hexagonal wrench to press the valve  
core pin, discharge for three seconds and then  
wait for one minute. Repeat this three times.  
If the gas leaks stop when the piping connections  
are tightened further, continue working from step (4).  
If the gas leaks do not stop when the connections  
are retightened, repair the location of the leak, dis-  
charge all of the gas through the service port, and  
then recharge with the specified amount of gas  
from a gas cylinder.  
(5) Use torque wrench to tighten the service port  
nut to a torque of 1.8kg.cm.  
-40-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Pumping down  
Liquid side  
2-Way  
Indoor unit  
Outdoor unit  
Open  
valve  
Gas side  
Closed  
3-Way  
valve  
Lo  
CLOSE  
CLOSE  
Purge the air  
Procedure  
(6) Operate the air conditioner at the cooling  
cycle and stop it when the gauge indicates  
1kg/cm2g.  
(1) Confirm that both the 2-way and 3-way valves  
are set to the open position.  
Remove the valve stem caps and confirm that  
the valve stems are in the raised position.  
Be sure to use a hexagonal wrench to operate  
the valve stems.  
(7) Immediately set the 3-way valve to the closed  
position.  
Do this quickly so that the gauge ends up indi-  
cating 3 to 5kg/cm2g.  
(2) Operate the unit for 10 to 15 minutes.  
(8) Disconnect the charge set, and mount the 2-  
way and 3-way valves stem nuts and the ser-  
vice port nut.  
(3) Stop operation and wait for 3 minutes, then  
connect the charge set to the service port of  
the 3-way valve.  
Use torque wrench to tighten the service port  
nut to a torque of 1.8 kg.m.  
Connect the charge hose with the push pin to  
the service port.  
Be sure to check for gas leakage.  
(4) Air purging of the charge hose.  
Open the low-pressure valve on the charge set  
slightly to air purge from the charge hose.  
(5) Set the 2-way valve to the closed position.  
-41-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1) Re-air purging  
(Re-installation)  
Liquid side  
2-Way  
Indoor unit  
Closed  
Outdoor unit  
valve  
Gas side  
Closed  
3-Way  
valve  
Gas cylinder  
Lo  
R22  
OPEN  
CLOSE  
Procedure  
(6) Disconnect the charge set and the gas cylin-  
der, and set the 2-way and 3-way valves to the  
(1) Confirm that both the 2-way valve and the 3-  
way valve are set to the closed position.  
open position.  
Be sure to use a hexagonal wrench to operate  
(2) Connect the charge set and a gas cylinder to  
the service port of the 3-way valve.  
the valve stems.  
Leave the valve on the gas cylinder closed.  
(7) Mount the valve stem nuts and the service  
port nut.  
(3) Air purging.  
Use torque wrench to tighten the service port  
nut to a torque of 1.8 kg.m.  
Be sure to check for gas leakage.  
Open the valves on the gas cylinder and the  
charge set. Purge the air by loosening the flare  
nut on the 2-way valve approximately 45° for 3  
seconds then closing it for 1 minute; repeat 3  
times.  
*
CAUTION:  
Do not leak the gas in the air during Air Purg-  
ing.  
After purging the air, use a torque wrench to  
tighten the flare nut on the 2-way valve.  
(4) Check for gas leakage.  
Check the flare connections for gas leakage.  
(5) Discharge the refrigerant.  
Close the valve on the gas cylinder and dis-  
charge the refrigerant until the gauge indicates  
3 to 5 kg/cm2g.  
-42-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2) Balance refrigerant of the 2-way, 3-way valves  
(Gas leakage)  
Liquid side  
Indoor unit  
Outdoor unit  
2-Way  
valve  
Open  
Gas side  
3-Way  
valve  
Open  
Lo  
OPEN  
CLOSE  
(3) Open the valve (Lo side) on the charge set  
and discharge the refrigerant until the gauge  
indicates 0 kg/cm2G.  
Procedure  
(1) Confirm that both the 2-way and 3-way valves  
are set to the back seat.  
If there is no air in the refrigerant cycle (the  
pressure when the air conditioner is not run-  
ning is higher than 1 kg/cm2G), discharge the  
refrigerant until the gauge indicates 0.5 to 1  
kg/cm2G. if this is the case, it will not be neces-  
sary to apply a evacuatin.  
Discharge the refrigerant gradually; if it is dis-  
charged too suddenly, the refrigeration oil will  
also be discharged.  
(2) Connect the charge set to the 3-way valves  
port.  
Leave the valve on the charge set closed.  
Connect the charge hose with the push pin to  
the service port.  
-43-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Evacuation  
(All amount of refrigerant leaked)  
Liquid side  
Indoor unit  
Outdoor unit  
2-Way  
valve  
Open  
Gas side  
3-Way  
valve  
Open  
Vacuum pump  
Lo  
OPEN  
CLOSE  
(4) Disconnect the charge hose from the vacuum  
pump.  
Procedure  
(1) Connect the vacuum pump to the charge sets  
Vacuum pump oil.  
center hose  
If the vacuum pump oil becomes dirty or  
depleted, replenish as needed.  
(2) Evacuation for approximately one hour.  
Confirm that the gauge needle has moved  
toward -76 cmHg (vacuum of 4 mmHg or less).  
(3) Close the valve (Lo side) on the charge set,  
turn off the vacuum pump, and confirm that  
the gauge needle does not move (approxima-  
tely 5 minutes after turning off the vacuum  
pump).  
-44-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Gas Charging  
(After Evacuation)  
Liquid side  
2-Way  
Indoor unit  
Outdoor unit  
Open  
valve  
Gas side  
Open  
3-Way  
valve  
Check valve  
Charging  
cylinder  
Lo  
(1)  
OPEN  
CLOSE  
Procedure  
\
(1) Connect the charge hose to the charging  
cylinder.  
This is different from previous procedures.  
Because you are charging with liquid refrigerant  
from the gas side, absolutely do not attempt to  
charge with larger amounts of liquid refrigerant  
while operating the air conditioner.  
Connect the charge hose which you dis-con-  
nected from the vacuum pump to the valve at  
the bottom of the cylinder.  
If you are using a gas cylinder, also use a scale  
and revers the cylinder so that the system can  
be charged with liquid.  
(4) Immediately disconnect the charge hose from  
the 3-way valves service port.  
(2) Purge the air from the charge hose.  
Open the valve at the bottom of the cylinder  
and press the check valve on the charge set to  
purge the air. (Be careful of the liquid refriger-  
ant). The procedure is the same if using a gas  
cylinder.  
Stopping partway will allow the gas to be dis-  
charged.  
If the system has been charged with liquid  
refrigerant while operating the air conditioner  
turn off the air conditioner before disconnecting  
the hose.  
(3) Open the valve (Lo side on the charge set and  
charge the system with liquid refrigerant.  
If the system can not be charged with the spec-  
ified amount of refrigerant, it can be charged  
with a little at a time (approximately 150g each  
time) while operating the air conditioner in the  
cooling cycle; however, one time is not suffi-  
cient, wait approximately 1 minute and then  
repeat the procedure (pumping down-pin).  
(5) Mount the valve stem nuts and the service  
port nut.  
Use torque wrench to tighten the service port  
nut to a torque of 1.8 kg.m.  
Be sure to check for gas leakage.  
-45-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cycle Troubleshooting Guide  
Trouble analysis  
1. Check temperature difference between intake and discharge air and operating current.  
Temp. difference : approx. 0°C  
All amount of refrigerant leaked  
out. Check refrigeration cycle.  
Current  
: less than 80% of  
rated current  
Temp. Difference  
Operating Current  
Refrigerant leakege  
Clog of refrigeration cycle  
Defective compressor  
Temp. difference : approx. 8°C  
Current : less than 80% of  
rated current  
Temp. difference : less than 8°C  
Excessive amount of refrigerant  
Current  
: over the reated  
current  
Normal  
Temp. difference : over 8°C  
Notice :  
Temperature difference between intake and discharge air depends on room air humidity. When the room air  
humidity is relativery higher, temperature difference is smaller. When the room air humidity is relatively lower tem-  
perature difference is larger.  
2. Check temperature and pressure of refrigeration cycle.  
Suction pressure  
(Compared with  
the normal value)  
Temperature  
(Compared with  
the normal valve)  
Cause of Trouble  
Description  
Defective compressor  
Defective 4-way reverse valve  
Current is low.  
High  
Higher  
Excessive amount of  
refrigerant  
High pressure does not quickly  
rise at the beginning of  
operation.  
Normal  
Insufficient amount of  
refrigerant (Leakage)  
Clogging  
Current is low.  
Current is low.  
Lower  
Higher  
Notice :  
1. The suction pressure is usually 4.5~6.0 kg/cm2G(Cooling) at normal condition.  
2. The temperature can be measured by attaching the thermometer to the low pressure tubing and wrap it with  
putty.  
-46-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electronic Parts Troubleshooting Guide  
1. Product does not operate at all.  
(* Refer to Electronic Control Device drawing and Schematic diagram.)  
Turn off Main Power  
(After 10 seconds)  
Turn on Main Power  
Does "beeping" sound is made from the Indoor Unit?  
YES  
NO  
Primarily, the operating condition of Micom is OK.  
Check the voltage of power(About AC 220V, 60Hz)  
(About AC 220/240V, 50Hz)  
Main power's voltage  
Voltage applied to the unit  
Connecting method of Indoor/Outdoor connecting  
cable  
Check PWB Assembly  
- Fuse  
Check each load(Indoor/Outdoor Fan Motor, Com-  
pressor, Stepping Motor) and contacting  
condition of related connector  
- Pattern damage  
- Varistor(ZNR01J)  
Check the connection housing for contacting  
Connector related to CN-TAB1, RY-COMP NO.3  
Connector related to CN-MOTOR  
Connector contacting of Outdoor Fan/Compressor  
Display PWB Assembly Check  
Main PCB Board Operation Check  
Content  
Remedy  
Items  
SMPS Transformer  
(Indoor unit)  
±
- Input Voltage  
- Output Voltage(ZD02D)  
- About AC220V/240V 10% - Check the power voltage  
- About DC12V  
Replace Trans  
+
IC04D(7805) Output  
(Indoor/Outdoor unit)  
DC 5V  
Replace IC04D  
Replace faulty parts  
IC01A(KIA7036, Reset IC)  
X01(8MHz)  
Voltage of Micom No. 2,  
(DC +4.5V over) and Soldering condition.  
-47-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. The product is not operate with the remote control.  
Turn on Main Power  
While the compressor has been stopped, the compressor does not  
operate owing to the delaying function for 3 minutes after stopped.  
When the compressor stopped Indoor Fan is driven by a low speed.  
At this point the wind speed is not controlled by the remote controller.  
(When operated in the Sleeping Mode, the wind speed is set to the  
low speed by force.)  
Caused by other parts except the remote control  
Cause by the remote control  
When the mark(  
battery.  
) is displayed in LCD screen, replace  
Check the contact of CN-DISP1 connector.  
Check the connecting circuit between the remote controller  
MICOM (No. ) - R17(2) - IR LED - TR - R16(2.2K).  
Check Display PWB Assembly  
- Voltage between CN DISP1  
+
-
: DC 5V  
Check point  
2
-
Check the connecting circuit between CN-DISP1  
43  
R01L(5.1K) - C01L(680pF) - MICOM PIN  
Check Receiver Assembly  
-48-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Compressor/Outdoor Fan are unable to drive.  
Turn on Main Power  
Operate "Cooling Mode( )" by setting the desired temperature of the  
remote controller is less than one of the indoor temperature by 1°C at least.  
When in Air Circulation Mode, Compressor/Outdoor Fan is stopped.  
Check the sensor for indoor temperature is attached as close as to be  
effected by the temperature of Heat Exchanger(EVA).  
When the sensor circuit for indoor temperature and connector are in bad  
connection or are not engaged, Compressor/Outdoor Fan is stopped.  
Check the related circuit of RY-FAN.  
Check the indoor temperature sensor is disconnected or not(About 10k/ at 25°C).  
Check Relay(RY - COMP) for driving compressor.  
When the power(About AC220V/240V) is applied to the connecting wire  
terminal support transferred to compressor, PWB Assembly is normal.  
Check the circuit related to the relay.  
Check point  
Between Micom(No.  
62) and GND  
COMP ON  
COMP OFF  
DC5V  
DC0V  
Between IC01M(No. 14)  
and GND  
Below DC 1V  
(app)  
About DC12V  
Turn off Main Power  
Check the electrical wiring diagram of outdoor side.  
Check the abnormal condition for the component of Compressor/Out-  
door Fan Motor.  
Check the "open" or "short" of conmecting wires between indoor and  
outdoor.  
-49-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. When indoor Fan does not operate.  
Turn off Main power  
Check the connection of CN-MOTOR  
Check the Fan Motor  
Check the Fuse(AC250V/T2A)  
Check the related circuit of indoor Fan Motor.  
The pin NO 58 of Micom, and the part for driving TRIAC(the input and  
output signal of IC01M, PIN NO 7, 10)  
Check the pattern  
Check the TRIAC  
- TRIAC Open: Indoor Fan Motor never operate  
- TRIAC short: Indoor Fan Motor always operates in case of ON or OFF.  
Turn ON Main Power  
Check the TRIAC high speed operation by remote control.  
(The Indoor Fan Motor is connected)  
The voltage of PIN NO 1(orange) and 3(yellow) of CN-MOTOR.  
About AC 180V over  
About AC 50V over  
TRIAC Check  
TRIAC is not damaged  
-50-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. When Vertical Louver does not operate.  
Confirm that the Vertical Louver is normally geared with the shaft of  
Stepping Motor.  
If the regular torque is detected when rotating the Vertical Louver with  
hands  
Normal  
Check the connecting condition of CN-U/D Connector  
Check the soldering condition(on PWB) of CN-U/D Connector  
Check the operating circuit of the Vertical Louver  
+
Confirm that there is DC 12V between pin (RED) of CN-U/D and  
GND.  
Confirm that there is a soldering short at following terminals.  
60 61 62  
63  
- Between  
- Between  
- Between  
,
,
,
,
,
,
and  
and  
and  
of MICOM  
of IC01M  
of IC01M  
If there are no problems after above checks  
Confirm the assembly conditions that are catching and interfering parts  
in the rotation radial of the Vertical Louver  
-51-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. When Heating does not operate  
Turn ON Main Power  
Operate Heating Mode( )by setting the desired temperature of the  
remote control is higher than one of the indoor temperature by 2°C at  
least.  
In heating Mode, the indoor fan operates in case the pipe temperature  
is higher than 28°C.  
Check the connector of intake and pipe sensor(thermistors)  
Check the related circuit of RY-4WAY  
Check the indoor room temperature is disconnected or not (about  
10K/at 25°C).  
Check the indoor pipe temperature is disconnected or not (about  
5K/at 25°C).  
Check the DC voltage on the PWB ASSEMBLY  
The details of check are as followings  
Comp Relay.  
Outdoor fan Relay  
Check point  
Comp ON  
DC 5V  
Comp OFF  
DC 0V  
Check point  
Fan ON  
DC 5V  
Fan OFF  
DC 0V  
Between Micom  
(NO.59) and GND  
Between Micom  
(NO.53) and GND  
Between IC01M  
(NO.11) and GND  
Between IC02M  
(NO.12) and GND  
Below DC 1V  
About DC  
12V  
Below DC 1V About DC 12V  
4 way Relay  
Check point  
4 way ON  
DC 5V  
4 way OFF  
DC 0V  
Between Micom  
(NO.51) and GND  
Between IC02M  
(NO.11) and GND  
Below DC 1V About DC 12V  
-52-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Turn off Main Power  
Check the electrical wiring diagram of outdoor side.  
Check the abnormal condition for the component of Compressor/Out-  
door Fan Motor, 4 way.  
Check the "open" or "short" of connecting wires between indoor and  
outdoor.  
-53-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electronic Control Device  
(1) MAIN P.W.B ASSEMBLY (AC PART)  
TOP VIEW  
BOTTOM VIEW  
(1) MAIN P.W.B ASM (AC)  
COOLING MODEL  
HEAT PUMP MODEL  
-54-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(2) MAIN P.W.B ASSEMBLY (DC PART)  
TOP VIEW  
BOTTOM VIEW  
TOP VIEW  
BOTTOM VIEW  
-55-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOP VIEW  
BOTTOM VIEW  
6871A 20164  
6871A 20216  
6871A 20217  
6871A 20218  
6871A 20219  
6871A 20220  
-56-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(3) DISPLAY ASSEMBLY  
6871A20194  
TOP VIEW  
BOTTOM VIEW  
6871A30009  
TOP VIEW  
BOTTOM VIEW  
6871A20227  
TOP VIEW  
BOTTOM VIEW  
-57-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6871A20390  
TOP VIEW  
K
BOTTOM VIEW  
6871A20391  
TOP VIEW  
C01A  
88SEG  
BOTTOM VIEW  
C01A  
-58-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Schematic Diagram  
-59-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cooling Model  
LED TYPE  
-60-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cooling Model  
HVB TYPE(PLASMA)  
-61-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Pump Model  
LED TYPE  
4 W A Y  
F A N  
-62-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Pump Model  
HVB TYPE  
4 W A Y  
F A N  
-63-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Exploded View and Replacement Parts List  
1. Indoor Unit  
135312  
152313  
135314  
152302  
733010  
131410  
359011  
267110  
342800  
159830  
135311  
159901  
268712  
346810  
35211B  
352150  
249951  
135516  
263230  
354212  
249951  
TYPE B  
TYPE A  
268714-2  
268714-1  
146811-2  
146811-1  
264110  
268714-1  
264110  
266090  
268714-2  
266090  
W0CZZ  
263232  
263230  
W6640  
-64-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Indoor)  
PART No.  
LOCATION No.  
DESCRIPTION  
REMARKS  
LS-Q076ABL  
3141A20006A  
3531A10127A  
3531A20101B  
3531A20100B  
3551A20050H  
4681A20055A  
5230A10005A  
5231AR2412T  
-
LS-Q076BBG  
LS-Q076BEL  
3141A20006A  
3531A10127E  
3531A20101E  
3531A20100C  
3551A20050H  
4681A20055A  
5230A10005A  
5231A30001C  
5983A10009D  
5990A10005A  
131410  
135311  
135312  
135314  
135516  
146811  
152302  
152313  
159830  
159901  
CHASSIS ASSEMBLY  
3141A20006B  
3531A10127E  
3531A20103B  
3531A20102D  
3551A20050H  
4681A20055A  
5230A10005A  
5231A30001C  
5983A10009B  
5990A10005A  
R
R
R
R
R
R
R
R
R
R
GRILLE ASSEMBLY, DISCHARGE(INDOOR)  
GRILLE ASSEMBLY, FRONT(INDOOR)  
GRILLE ASSEMBLY, INLET SUB  
COVER ASSEMBLY, MOTOR  
MOTOR ASSEMBLY, STEP  
FILTER(MECH), A/C  
FILTER ASSEMBLY, DEODORIZER  
AIR CLEANER ASSEMBLY  
VANE, HORIZONTAL  
5990A10005A  
4995A20199R  
(4995A20257J)  
4995A20199T  
4995A20257K)  
4995A20199T  
4995A20257K)  
249951  
263230  
264110  
266090  
267110  
CONTROL BOX ASSEMBLY, INDOOR  
THERMISTOR ASSEMBLY  
POWER CORD ASSEMBLY  
H.V ASSEMBLY  
R
R
R
R
R
6323A20004A  
6323A20004A  
6323A20004A  
6411A20013D  
(6411A20026D)  
6411A20013D  
(6411A20026D)  
6411A20013D  
(6411A20026D)  
-
6609A10003J  
6609A10003J  
6711A20010B  
(6711A20067G)  
REMOTE CONTROLLER ASSEMBLY  
6711A20010F  
6711A20010F  
6871A20194A  
(6871A20194F)  
6871A20227D  
(6871A20227G)  
6871A20227D  
(6871A20227G)  
268712  
268714-1  
268714-2  
PWB(PCB) ASSEMBLY, DISPLAY  
PWB(PCB) ASSEMBLY, MAIN(AC)  
PWB(PCB) ASSEMBLY, MAIN(DC)  
R
R
R
6871A20163A  
(6871A20272J)  
6871A20163A  
(6871A20272J)  
6871A20163A  
(6871A20272J)  
6871A20218Q  
(6871A20310B)  
6871A20225L  
(6871A20310C)  
6871A20225L  
(6871A20310C)  
342800  
346810  
352150  
354211  
359011  
35211B  
733010  
W0CZZ  
W6640  
BEARING  
4280A20004A  
4681A20062D  
5251AR2575F  
5421A10025C  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062D  
5251AR2575F  
5421A10025C  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062D  
5251AR2575F  
5421A10025G  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
R
R
R
R
R
R
R
R
R
MOTOR ASSEMBLY, INDOOR  
HOSE ASSEMBLY, DRAIN  
EVAPORATOR ASSEMBLY, BENDING  
FAN ASSEMBLY, CROSS FLOW  
TUBE ASSEMBLY, TUBING  
PLATE ASSEMBLY, INSTALL  
CAPACITOR, DRAWING  
PWB(PCB) ASSEMBLY, MAIN(AC)  
6871A20283A  
6871A20283A  
6871A20283A  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
1) TYPE A : ~2002  
2) TYPE B : 2003~  
-65-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Indoor)  
PART No.  
LOCATION  
No.  
DESCRIPTION  
REMARKS  
LS-Q096ABL LS-Q096BBG LS-Q096BEL LS-Q096AEM LS-Q096BEG  
131410 CHASSIS ASSEMBLY  
3141A20006A  
3141A20006B  
3531A10127E  
3531A20103B  
3531A20102D  
3551A20050H  
4681A20055A  
5230A10005A  
5231A30001C  
5983A10009B  
5990A10005A  
4995A20199J  
3141A20006A  
3531A10127E  
3531A20101E  
3531A20100C  
3551A20050H  
4681A20055A  
5230A10005A  
5231A30001C  
5983A10009D  
5990A10005A  
4995A20199J  
3141A20006A  
3531A10232J  
3531A10167C  
3531A20142A  
3551A20050H  
4681A20055A  
5230A10005A  
-
3141A20006A  
3531A10127R  
3531A10225E  
3531A20102X  
3551A20050H  
4681A20055A  
5230A10005A  
5231A30001C  
5983A10009B  
5990A10005A  
R
R
R
R
R
R
R
R
R
R
135311 GRILLE ASSEMBLY, DISCHARGE(INDOOR) 3531A10127A  
135312 GRILLE ASSEMBLY, FRONT(INDOOR)  
135314 GRILLE ASSEMBLY, INLET SUB  
135516 COVER ASSEMBLY, MOTOR  
146811 MOTOR ASSEMBLY, STEP  
152302 FILTER(MECH), A/C  
3531A20101B  
3531A20100B  
3551A20050H  
4681A20055A  
5230A10005A  
5231AR2412T  
-
152313 FILTER ASSEMBLY, DEODORIZER  
159830 AIR CLEANER ASSEMBLY  
159901 VANE, HORIZONTAL  
-
5990A10005A  
5990A10005A  
4995A20199H  
(4995A20257B)  
249951 CONTROL BOX ASSEMBLY, INDOOR  
263230 THERMISTOR ASSEMBLY  
264110 POWER CORD ASSEMBLY  
266090 H.V ASSEMBLY  
4995A20257G  
6323A20004K  
6411A20026E  
-
4995A20257S  
6323A20004K  
6411A20026E  
6609A10003N  
6711A20083G  
R
R
R
R
R
(4995A20257D) (4995A20257D)  
6323A20004A  
6323A20004A  
6411A20013D  
(6411A20026D) (6411A20026D)  
6323A20004A  
6411A20013D  
6411A20013D  
(6411A20026D)  
-
6609A10003J  
6609A10003J  
6711A20010B  
(6711A20067G)  
6711A20010F  
6711A20010F  
267110 REMOTE CONTROLLER ASSEMBLY  
6711A20012M  
(6711A20067J) (6711A20067J)  
6871A20227D 6871A20227D  
(6871A20227G) (6871A20227G)  
6871A20163A 6871A20163A  
(6871A20272A) (6871A20272A)  
6871A20225N 6871A20225N  
(6871A20310J) (6871A20310J)  
6871A20194A  
(6871A20194F)  
268712 PWB(PCB) ASSEMBLY, DISPLAY  
268714-1 PWB(PCB) ASSEMBLY, MAIN(AC)  
268714-2 PWB(PCB) ASSEMBLY, MAIN(DC)  
6871A20390C  
6871A20272A  
6871A20310G  
6871A20227G  
6871A20272A  
6871A20310J  
R
R
R
6871A20163A  
(6871A20272A)  
6871A20218H  
(6871A20310G)  
342800 BEARING  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025B  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025B  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025E  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025E  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5211AR7066P  
5251AR2575F  
5421A10025E  
5901A20007B  
3301A10003A  
3H01487A  
R
R
R
R
R
R
R
R
R
346810 MOTOR ASSEMBLY, INDOOR  
352150 HOSE ASSEMBLY, DRAIN  
354212 EVAPORATOR ASSEMBLY, BENDING  
359011 FAN ASSEMBLY, CROSS FLOW  
35211B TUBE ASSEMBLY, TUBING  
733010 PLATE ASSEMBLY, INSTALL  
W0CZZ CAPACITOR, DRAWING  
W6640 PWB(PCB) ASSEMBLY, MAIN(AC)  
6871A20283A  
6871A20283A  
6871A20283A  
6871A20283A  
6871A20283A  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
1) TYPE A : ~2002  
2) TYPE B : 2003~  
-66-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Indoor)  
PART No.  
LOCATION  
No.  
DESCRIPTION  
REMARKS  
LS-Q096AHG LS-Q096ACG LS-Q096BAG LS-Q096ACL LS-Q096AAG  
131410 CHASSIS ASSEMBLY  
3141A20006B  
3141A20006B  
3531A10127H  
3531A20103A  
3531A20102A  
3551A20050E  
4681A20055A  
5230A10005A  
-
3141A20006B  
3531A10127H  
3531A20103J  
3531A20102J  
3551A20050E  
4681A20055A  
5230A10005A  
5231A30001C  
5983A10009B  
5990A10005A  
4995A20199Z  
3141A20006B  
3531A10127H  
3531A20101K  
3531A20100H  
3551A20050E  
4681A20055A  
5230A10005A  
5231AR2412T  
-
3141A20006A  
3531A10127P  
3531A20103U  
3531A20102A  
3551A20050E  
4681A20055A  
5230A10005A  
-
R
R
R
R
R
R
R
R
R
R
135311 GRILLE ASSEMBLY, DISCHARGE(INDOOR) 3531A10127H  
135312 GRILLE ASSEMBLY, FRONT(INDOOR)  
135314 GRILLE ASSEMBLY, INLET SUB  
135516 COVER ASSEMBLY, MOTOR  
146811 MOTOR ASSEMBLY, STEP  
152302 FILTER(MECH), A/C  
3531A20103H  
3531A20102H  
3551A20050H  
4681A20055A  
5230A10005A  
-
152313 FILTER ASSEMBLY, DEODORIZER  
159830 AIR CLEANER ASSEMBLY  
159901 VANE, HORIZONTAL  
-
-
-
5990A10005A  
5990A10005A  
5990A10005A  
5990A10005A  
4995A20199H  
(4995A20257B)  
4995A20199A  
(4995A20257A) (4995A20257C)  
249951 CONTROL BOX ASSEMBLY, INDOOR  
263230 THERMISTOR ASSEMBLY  
264110 POWER CORD ASSEMBLY  
266090 H.V ASSEMBLY  
4995A20232A  
4995A20257A  
R
6323A20004A  
6323A20004A  
6411A20013D  
(6411A20026D) (6411A20026D)  
6323A20004A  
6411A20013D  
6323A20004A  
6411A20013D  
6323A20004L  
6411A20026D  
R
R
6411A20013D  
(6411A20026D)  
-
-
6609A10003J  
6609A10003J  
6711A20010A  
-
R
R
6711A20010B  
(6711A20067G)  
6711A20010A  
6711A20010E  
267110 REMOTE CONTROLLER ASSEMBLY  
6711A20067E  
(6711A20067E) (6711A20067H)  
6871A20194A 6871A20227D  
(6871A20390C) (6871A20227G)  
6871A20163B 6871A20163B  
(6871A20272K) (6871A20272K)  
6871A20218A 6871A20225P  
(6871A20310E) (6871A20310H)  
6871A20194A  
(6871A20390C)  
268712 PWB(PCB) ASSEMBLY, DISPLAY  
268714-1 PWB(PCB) ASSEMBLY, MAIN(AC)  
268714-2 PWB(PCB) ASSEMBLY, MAIN(DC)  
6871A20390A  
6871A20163B  
6871A20218A  
6871A20294F  
R
R
R
6871A20163A  
(6871A20272A)  
6871A20272B  
(6871A20283B)  
6871A20218H  
(6871A20310G)  
6871A20310E  
342800 BEARING  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025B  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025B  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025B  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025B  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025A  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
R
R
R
R
R
R
R
R
R
R
346810 MOTOR ASSEMBLY, INDOOR  
352150 HOSE ASSEMBLY, DRAIN  
354211 EVAPORATOR ASSEMBLY, BENDING  
359011 FAN ASSEMBLY, CROSS FLOW  
35211B TUBE ASSEMBLY, TUBING  
733010 PLATE ASSEMBLY, INSTALL  
W0CZZ CAPACITOR, DRAWING  
263232 CABLE, FLAT  
-
-
-
6850A90001C  
-
-
W6640 PWB(PCB) ASSEMBLY, MAIN(AC)  
6871A20283B  
6871A20283B  
6871A20283B  
6871A20283B  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
1) TYPE A : ~2002  
2) TYPE B : 2003~  
-67-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Indoor)  
PART No.  
LOCATION  
No.  
DESCRIPTION  
REMARKS  
LS-Q096ABG LS-Q076ABG LS-Q082BAG LS-Q082BDL LS-N096QNA0  
131410 CHASSIS ASSEMBLY  
3141A20006A  
3141A20006A  
3531A10127A  
3531A20101B  
3531A20100B  
3551A20050H  
4681A20055A  
5230A10005A  
5231AR2412T  
-
3141A20006A  
3531A10127E  
3531A20103J  
3531A20102J  
3551A20050E  
4681A20055A  
5230A10005A  
5231A30001C  
5983A10009B  
5990A10005A  
3141A20006A  
3531A10127A  
3531A20101T  
3531A20100R  
3551A20050E  
4681A20055A  
5230A10005A  
5231A30001C  
5983A10009B  
5990A10005A  
3141A20006A  
3531A10127P  
3531A10194K  
3531A20153K  
3551A20050H  
4681A20055A  
5230A10005C  
-
R
R
R
R
R
R
R
R
R
R
135311 GRILLE ASSEMBLY, DISCHARGE(INDOOR) 3531A10127A  
135312 GRILLE ASSEMBLY, FRONT(INDOOR)  
135314 GRILLE ASSEMBLY, INLET SUB  
135516 COVER ASSEMBLY, MOTOR  
146811 MOTOR ASSEMBLY, STEP  
152302 FILTER(MECH), A/C  
3531A20101B  
3531A20100B  
3551A20050H  
4681A20055A  
5230A10005A  
5231AR2412T  
-
152313 FILTER ASSEMBLY, DEODORIZER  
159830 AIR CLEANER ASSEMBLY  
159901 VANE, HORIZONTAL  
-
5990A10005A  
5990A10005A  
5990A10005A  
4995A20199H  
(4995A20257B)  
4995A20199R  
(4995A20257J)  
249951 CONTROL BOX ASSEMBLY, INDOOR  
263230 THERMISTOR ASSEMBLY  
264110 POWER CORD ASSEMBLY  
266090 H.V ASSEMBLY  
4995A20199W  
6323A20004A  
6411A20013D  
6609A10003J  
6711A20010E  
4995A20199L  
6323A20004A  
6411A20013D  
6609A10003J  
6711A20010E  
4995A20257T  
6323A20004K  
6411A20026E  
-
R
R
R
R
R
6323A20004A  
6323A20004A  
6411A20013D  
(6411A20026D)  
6411A20013D  
(6411A20026D)  
-
-
6711A20010B  
(6711A20067G)  
6711A20010B  
(6711A20067G)  
267110 REMOTE CONTROLLER ASSEMBLY  
6711A20028B  
6871A20194A  
(6871A20194F)  
6871A20194A  
(6871A20194F)  
268712 PWB(PCB) ASSEMBLY, DISPLAY  
268714-1 PWB(PCB) ASSEMBLY, MAIN(AC)  
268714-2 PWB(PCB) ASSEMBLY, MAIN(DC)  
6871A20391C  
6871A20163B  
6871A20235A  
6871A20391C  
6871A20163B  
6871A20225P  
6871A20194F  
6871A20272R  
6871A20310G  
R
R
R
6871A20163A  
(6871A20272A)  
6871A20163A  
(6871A20272J)  
6871A20218H  
(6871A20310G)  
6871A20218Q  
(6871A20310B)  
342800 BEARING  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025B  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062D  
5251AR2575F  
5421A10025C  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062E  
5251AR2575F  
5421A10025A  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025F  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5211AR7066P  
5251AR2575F  
5421A10025B  
5901A20007B  
3301A10003A  
3H01487A  
R
R
R
R
R
R
R
R
R
R
346810 MOTOR ASSEMBLY, INDOOR  
352150 HOSE ASSEMBLY, DRAIN  
354211 EVAPORATOR ASSEMBLY, FINAL  
359011 FAN ASSEMBLY, CROSS FLOW  
35211B TUBE ASSEMBLY, TUBING  
733010 PLATE ASSEMBLY, INSTALL  
W0CZZ CAPACITOR, DRAWING  
263232 CABLE, FALT  
6850A90001C  
6871A20283A  
6850A90001C  
6871A20283A  
6850A90001C  
-
6850A90001C  
-
-
W6640 PWB(PCB) ASSEMBLY, MAIN(AC)  
6871A20283A  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
1) TYPE A : ~2002  
2) TYPE B : 2003~  
-68-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Indoor)  
PART No.  
LOCATION  
DESCRIPTION  
REMARKS  
No.  
LS-Q096AEL LS-Q096ADG LS-Q096ADL LS-Q096BDG LS-Q096ABM  
131410 CHASSIS ASSEMBLY  
3141A20006A  
3141A20006B  
3531A10127A  
3531A20103A  
3531A20102A  
3551A20050E  
4681A20055A  
5230A10005A  
-
3141A20006A  
3531A10127A  
3531A20101A  
3531A20100A  
3551A20050E  
4681A20055A  
5230A10005A  
-
3141A20006B  
3531A10127E  
3531A20103J  
3531A20102J  
3551A20050E  
4681A20055A  
5230A10005A  
5231A30001C  
5983A10009B  
5990A10005A  
4995A20199L  
3141A20006B  
3531A10127P  
3531A10167F  
3531A20142D  
3551A20050H  
4681A20055A  
5230A10005A  
-
R
R
R
R
R
R
R
R
R
R
135311 GRILLE ASSEMBLY,DISCHARGE(INDOOR) 3531A10127A  
135312 GRILLE ASSEMBLY,FRONT(INDOOR)  
135314 GRILLE ASSEMBLY,INLET SUB  
135516 COVER ASSEMBLY,MOTOR  
146811 MOTOR ASSEMBLY,STEP  
152302 FILTER(MECH),A/C  
3531A20101B  
3531A20100B  
3551A20050H  
4681A20055A  
5230A10005A  
-
152313 FILTER ASSEMBLY,DEODORIZER  
159830 AIR CLEANER ASSEMBLY  
159901 VANE,HORIZONTAL  
-
-
-
-
5990A10005A  
5990A10005A  
5990A10005A  
5990A10005A  
4995A20232C  
4995A20199A  
4995A20232B  
249951 CONTROL BOX ASSEMBLY,INDOOR  
263230 THERMISTOR ASSEMBLY  
264110 POWER CORD ASSEMBLY  
266090 H.V ASSEMBLY  
4995A20257B  
6323A20004K  
6411A20026D  
-
R
R
R
R
R
(4995A20257G) (4995A20257A) (4995A20257A) (4995A20257C)  
6323A20004A  
6411A20013T  
6323A20004A  
6411A20013D  
6323A20004C  
6411A20013T  
6323A20004C  
6411A20013D  
(6411A20026E) (6411A20026D) (6411A20026D) (6411A20026D)  
-
-
-
6609A10003J  
6711A20010E  
6871A20227D  
6711A20028B  
(6711A20067S)  
267110 REMOTE CONTROLLER ASSEMBLY  
6711A20010A  
6871A20194A  
6711A20028A  
6871A20194A  
6711A20010B  
6871A20194A  
268712 PWB(PCB) ASSEMBLY,DISPLAY  
268714-1 PWB(PCB) ASSEMBLY,MAIN(AC)  
268714-2 PWB(PCB) ASSEMBLY,MAIN(DC)  
6871A20194F  
6871A20272A  
6871A20310G  
R
R
R
(6871A20390C) (6871A20390C) (6871A20390C) (6871A20391G)  
6871A20163A  
(6871A20272A) (6871A20272K) (6871A20272K)  
6871A20218H 6871A20218A 6871A20218A  
6871A20163B  
6871A20163B  
6871A20163B  
(6871A20272K)  
6871A20225P  
(6871A20310G) (6871A20310E) (6871A20310E) (6871A20310H)  
342800 BEARING  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025E  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025F  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025F  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025F  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
4280A20004A  
4681A20062A  
5251AR2575F  
5421A10025B  
5901A20007B  
5211AR7066P  
3301A10003A  
3828A20243C  
3H01487A  
R
R
R
R
R
R
R
R
R
R
346810 MOTOR ASSEMBLY,INDOOR  
352150 HOSE ASSEMBLY,DRAIN  
354211 EVAPORATOR ASSEMBLY,BENDING  
359011 FAN ASSEMBLY,CROSS FLOW  
35211B TUBE ASSEMBLY,TUBING  
733010 PLATE ASSEMBLY,INSTALL  
W0CZZ CAPACITOR,DRAWING  
263232 CABLE,FLAT  
-
-
-
6850A90001C  
6871A20283B  
W6640 PWB(PCB) ASSEMBLY, MAIN(AC)  
6871A20283A  
6871A20283B  
6871A20283B  
6871A20283A  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
1) TYPE A : ~2002  
2) TYPE B : 2003~  
-69-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Indoor)  
PART No.  
LOCATION  
DESCRIPTION  
REMARKS  
No.  
LS-Q082BAM LS-Q082AAL LS-Q082ACG LS-Q082ACL LS-Q082ACM  
131410 CHASSIS ASSEMBLY  
3141A20006B  
3141A20006B  
3531A10127A  
3531A20101R  
3531A20100P  
3551A20050E  
4681A20055A  
5230A10005A  
-
3141A20006A  
3531A10127A  
3531A20103G  
3531A20102G  
3551A20050E  
4681A20055A  
5230A10005A  
5231AR2412T  
-
3141A20006A  
3531A10127A  
3531A20101K  
3531A20100H  
3551A20050E  
4681A20055A  
5230A10005A  
5231AR2412T  
-
3141A20006A  
3531A10127A  
3531A10167H  
3531A20142F  
3551A20050E  
4681A20055A  
5230A10005A  
5231AR2412T  
-
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
135311 GRILLE ASSEMBLY,DISCHARGE(INDOOR) 3531A10127R  
135312 GRILLE ASSEMBLY,FRONT(INDOOR)  
135314 GRILLE ASSEMBLY,INLET SUB  
135516 COVER ASSEMBLY,MOTOR  
146811 MOTOR ASSEMBLY,STEP  
152302 FILTER(MECH),A/C  
3531A10167G  
3531A20142E  
3551A20050E  
4681A20055A  
5230A10005A  
5231A30001C  
5983A10009C  
5990A10005A  
4995A20257N  
6323A20004L  
6411A20015H  
6711A20069B  
6871A20391G  
6871A20272K  
6871A20310D  
4280A20004A  
4681A20062E  
5251AR2575F  
5421A10025A  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
152313 FILTER ASSEMBLY,DEODORIZER  
159830 AIR CLEANER ASSEMBLY  
159901 VANE,HORIZONTAL  
-
5990A10005A  
4995A20232N  
6323A20004C  
6411A20015B  
6711A20069A  
6871A20390A  
6871A20163B  
6871A20218V  
4280A20004A  
4681A20062E  
5251AR2575F  
5211AR7066P  
5421A10025A  
5901A20007B  
3301A10003A  
3H01487A  
5990A10005A  
4995A20232R  
6323A20004C  
3H03671F  
5990A10005A  
4995A20232R  
6323A20004C  
3H03671F  
5990A10005A  
4995A20232R  
6323A20004C  
3H03671F  
249951 CONTROL BOX ASSEMBLY,INDOOR  
263230 THERMISTOR ASSEMBLY  
264110 POWER CORD ASSEMBLY  
267110 REMOTE CONTROLLER ASSEMBLY  
268712 PWB(PCB) ASSEMBLY,DISPLAY  
268714-1 PWB(PCB) ASSEMBLY,MAIN(AC)  
268714-2 PWB(PCB) ASSEMBLY,MAIN(DC)  
342800 BEARING  
6711A20067V  
6871A20390A  
6871A20163B  
6871A20218V  
4280A20004A  
4681A20062E  
5251AR2575F  
5421A10025A  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
6711A20067V  
6871A20390A  
6871A20163B  
6871A20218V  
4280A20004A  
4681A20062E  
5251AR2575F  
5421A10025A  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
6711A20067V  
6871A20390A  
6871A20163B  
6871A20218V  
4280A20004A  
4681A20062E  
5251AR2575F  
5421A10025A  
5901A20007B  
5211AR7066P  
3301A10003A  
3H01487A  
346810 MOTOR ASSEMBLY,INDOOR  
352150 HOSE ASSEMBLY,DRAIN  
354211 EVAPORATOR ASSEMBLY,FINAL  
359011 FAN ASSEMBLY,CROSS FLOW  
35211B TUBE ASSEMBLY,TUBING  
733010 PLATE ASSEMBLY,INSTALL  
W0CZZ CAPACITOR,DRAWING  
W6640 PWB(PCB) ASSEMBLY, MAIN(AC)  
6871A20283B  
-
-
-
-
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
-70-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Indoor)  
PART No.  
LOCATION  
No.  
DESCRIPTION  
REMARKS  
LS-C082QMA0  
LS-C082QNA0  
LS-C096QGL0  
131410  
135311  
135312  
135314  
135516  
146811  
152302  
152313  
159830  
159901  
249951  
263230  
264110  
266090  
267110  
268712  
CHASSIS ASSEMBLY  
3141A20006A  
3531A10232B  
3531A21013A  
-
3141A20006A  
3531A10232B  
3531A21021A  
-
3141A20006A  
3531A10232B  
3531A21013A  
-
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
GRILLE ASSEMBLY,DISCHARGE(INDOOR)  
GRILLE ASSEMBLY,FRONT(INDOOR)  
GRILLE ASSEMBLY,INLET SUB  
COVER ASSEMBLY,MOTOR  
MOTOR ASSEMBLY,STEP  
3551A20099F  
4681A20055A  
5230A10005A  
5231A20032E  
-
3551A20099F  
4681A20055A  
5230A10005A  
5231A20032E  
-
3551A20099F  
4681A20055A  
5230A10005A  
5231A20032E  
-
FILTER(MECH),A/C  
FILTER ASSEMBLY,DEODORIZER  
AIR CLEANER ASSEMBLY  
VANE,HORIZONTAL  
5990A10005A  
4995A20232R  
6323A20004C  
3H03671F  
5990A10005A  
4995A20232R  
6323A20004C  
3H03671F  
5990A10005A  
4995A20232R  
6323A20004C  
3H03671F  
CONTROL BOX ASSEMBLY,INDOOR  
THERMISTOR ASSEMBLY  
POWER CORD ASSEMBLY  
H.V ASSEMBLY  
-
-
-
REMOTE CONTROLLER ASSEMBLY  
PWB(PCB) ASSEMBLY,DISPLAY  
6711A20067V  
6871A20390A  
6871A20163B  
6871A20218V  
4280A20004A  
4681A20062E  
5211A21046H  
5251AR2575F  
5421A10038A  
5901A20007E  
3301A10003A  
3H01487A  
6711A20067V  
6871A20390A  
6871A20163B  
6871A20218V  
4280A20004A  
4681A20062E  
5211A21046H  
5251AR2575F  
5421A10038A  
5901A20007E  
3301A10003A  
3H01487A  
6711A20067V  
6871A20390A  
6871A20163B  
6871A20218V  
4280A20004A  
4681A20062E  
5211A21046H  
5251AR2575F  
5421A10038A  
5901A20007E  
3301A10003A  
3H01487A  
268714-1 PWB(PCB) ASSEMBLY,MAIN(AC)  
268714-2 PWB(PCB) ASSEMBLY,MAIN(DC)  
342800  
346810  
35211B  
352150  
354211  
359011  
733010  
W0CZZ  
263232  
W6640  
BEARING  
MOTOR ASSEMBLY,INDOOR  
TUBE ASSEMBLY,TUBING  
HOSE ASSEMBLY,DRAIN  
EVAPORATOR ASSEMBLY,FINAL  
FAN ASSEMBLY,CROSS FLOW  
PLATE ASSEMBLY,INSTALL  
CAPACITOR,DRAWING  
CABLE,FLAT  
-
-
-
PWB(PCB) ASSEMBLY,SUB  
6871A20283B  
6871A20283B  
6871A20283B  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
-71-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Indoor)  
PART No.  
LOCATION  
No.  
DESCRIPTION  
REMARKS  
LS-C096QLA0  
LS-C096QNA0  
LS-H096QGL1  
131410  
135311  
135312  
135314  
135516  
146811  
152302  
152313  
159830  
159901  
249951  
263230  
264110  
266090  
267110  
268712  
CHASSIS ASSEMBLY  
3141A20006A  
3531A10127P  
3531A21014E  
-
3141A20006C  
3531A10127X  
3531A21021B  
-
3141A20006A  
3531A10127R  
3531A20103B  
3531A20102D  
3551A20050H  
4681A20055A  
5230A10005A  
5231A20032C  
5983A10009V  
5990A10005A  
4995A20257U  
6323A20004K  
6411A20026D  
6609A10003N  
6711A20077L  
6871A20227G  
6871A20272A  
6871A20310M  
4280A20004A  
4681A20062L  
5211A21046H  
5251AR2575F  
5421A10038G  
5901A20007E  
3301A10003A  
3H01487A  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
GRILLE ASSEMBLY,DISCHARGE(INDOOR)  
GRILLE ASSEMBLY,FRONT(INDOOR)  
GRILLE ASSEMBLY,INLET SUB  
COVER ASSEMBLY,MOTOR  
MOTOR ASSEMBLY,STEP  
3551A20050E  
4681A20055A  
5230A10005A  
5231A20032E  
-
3551A20050E  
4681A20055A  
5230A10005A  
5231A20032E  
-
FILTER(MECH),A/C  
FILTER ASSEMBLY,DEODORIZER  
AIR CLEANER ASSEMBLY  
VANE,HORIZONTAL  
5990A10005A  
4995A20424B  
6323A20004L  
6411A20043C  
-
5990A10005A  
4995A20424B  
6323A20004L  
6411A20043C  
-
CONTROL BOX ASSEMBLY,INDOOR  
THERMISTOR ASSEMBLY  
POWER CORD ASSEMBLY  
H.V ASSEMBLY  
REMOTE CONTROLLER ASSEMBLY  
PWB(PCB) ASSEMBLY,DISPLAY  
6711A20067E  
6871A20194F  
6871A20272K  
6871A20310E  
4280A20004A  
4681A20062L  
5211A21046H  
5251AR2575F  
5421A10038A  
5901A20007E  
3301A10003A  
3H01487A  
6711A20067E  
6871A20194F  
6871A20272K  
6871A20310E  
4280A20004A  
4681A20062L  
5211A21046H  
5251AR2575F  
5421A10038A  
5901A20007E  
3301A10003A  
3H01487A  
268714-1 PWB(PCB) ASSEMBLY,MAIN(AC)  
268714-2 PWB(PCB) ASSEMBLY,MAIN(DC)  
342800  
346810  
35211B  
352150  
354211  
359011  
733010  
W0CZZ  
263232  
W6640  
BEARING  
MOTOR ASSEMBLY,INDOOR  
TUBE ASSEMBLY,TUBING  
HOSE ASSEMBLY,DRAIN  
EVAPORATOR ASSEMBLY,FINAL  
FAN ASSEMBLY,CROSS FLOW  
PLATE ASSEMBLY,INSTALL  
CAPACITOR,DRAWING  
CABLE,FLAT  
-
-
-
PWB(PCB) ASSEMBLY,SUB  
6871A20283B  
6871A20283B  
6871A20283A  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
-72-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Outdoor unit  
437210  
552111  
552102  
437212  
554031  
435511  
559010  
546810  
W0CZZ  
649950  
552116  
567502  
554160  
550140  
552202  
561410  
552203-1  
552203-2  
430410  
-73-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Outdoor)  
PART No.  
LOCATION No.  
DESCRIPTION  
REMARKS  
LS-Q076ABL LS-Q076BBG LS-Q076BEL LS-Q076ABG  
437210  
546810  
430410  
435511  
437212  
550140  
552102  
552111  
552116  
552202  
552203-1  
552203-2  
554031  
554160  
559010  
561410  
567502  
649950  
W0CZZ  
GRILLE ASSEMBLY, FRONT(OUTDOOR)  
MOTOR ASSEMBLY, OUTDOOR  
BASE ASSEMBLY, WELD[OUTDOOR]  
COVER ASSEMBLY, CONTROL(OUTDOOR)  
PANEL ASSEMBLY, REAR(OUTDOOR)  
ISOLATOR, COMP  
3531AR2512R 3531AR2512R 3531AR2512R 3531AR2512R  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
4681A20004F  
4681A20004F  
4681A20004F  
4681A20004F  
3041AR2415K 3041AR2415K 3041AR2415K 3041AR2415K  
4994AR3492B 4994AR3492B 4994AR3492B 4994AR3492B  
3530AR0058C 3530AR0058C 3530AR0058C 3530AR0058C  
4H00982E  
5210A30151L  
5211A30082S  
4H00982E  
5210A30151L  
5211A30082S  
4H00982E  
5210A30151L  
5211A30082S  
4H00982E  
5210A30151L  
5211A30082S  
TUBE, CAPILLARY BEND  
TUBE ASSEMBLY, CAPILLARY  
TUBE ASSEMBLY, REVERSING  
VALVE, REVERSING  
5211A30095C 5211A30095C 5211A30095C 5211A30095C  
5220AR3084A 5220AR3084A 5220AR3084A 5220AR3084A  
VALVE, SERVICE  
2H02479F  
2A00393M  
2H02479F  
2A00393M  
2H02479F  
2A00393M  
2H02479F  
2A00393M  
VALVE, SERVICE  
CONDENSER ASSEMBLY, BENT  
COMPRESSOR SET  
5403AR2475L 5403AR2475L 5403AR2475L 5403AR2475L  
2520UKYP2CA 2520UKYP2CA 2520UKYP2CA 2520UKYP2CA  
5900AR1266A 5900AR1266A 5900AR1266A 5900AR1266A  
FAN ASSEMBLY, PROPELLER  
COIL ASSEMBLY, REVERSING VALVE  
O.L.P  
3A02028G  
6750U-L014A  
4995A20031A  
3A02028G  
6750U-L014A  
4995A20031A  
3A02028G  
6750U-L014A  
4995A20031A  
3A02028G  
6750U-L014A  
4995A20031A  
CONTROL BOX ASSEMBLY, OUTDOOR  
CAPACITOR, DRAWING  
6120AR2194H 6120AR2194H 6120AR2194H 6120AR2194H  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
-74-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Outdoor unit  
437210  
437212  
554031  
435301  
435511  
546810  
552102-2  
559010  
649950  
552201  
552111  
552102-1 552116  
552202  
W0CZZ  
567502  
561410  
554160  
447910  
550140  
552203-1  
430410  
552203-2  
-75-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Outdoor)  
PART No.  
LOCATION  
DESCRIPTION  
REMARKS  
No.  
LS-Q096ACG LS-Q096BAG LS-Q096ACL LS-Q082BAG LS-Q096ABM LS-H096QNA0  
430410 BASE ASSEMBLY, WELD[OUTDOOR]  
435301 GRILLE, DISCHARGE  
3041AR2415K 3041AR2415K 3041AR2415K 3041AR2415E 3041A20008K 3041A20016A  
3530A20006B 3530A20006B 3530A20006B 3530A20006B 3530A20006B 3530A10059D  
R
R
R
R
R
R
R
R
435511 COVER ASSEMBLY, CONTROL(OUTDOOR) 4994AR3492B 4994AR3492B 4994AR3492B 4994AR3492B 3551A30023E 3551A30023Q  
437210 PANEL ASSEMBLY, FRONT(OUTDOOR)  
437212 PANEL ASSEMBLY, REAR(OUTDOOR)  
447910 BARRIER ASSEMBLY, OUTDOOR  
546810 MOTOR ASSEMBLY, OUTDOOR  
550140 ISOLATOR, COMP  
3531AR2512R 3531AR2512R 3531AR2512R 3531AR2512R 3721A20027A 3721A20060B  
3530AR0058B 3530AR0058B 3530AR0058B 3530AR0058B 3721A20026B 3721A20059A  
-
-
-
-
-
4971A30002B  
4681A20004F 4681A20004F 4681A20004F 4681A20068A 4681A20004J 4791A20011A  
4H00982E  
4H00982E  
4H00982E  
4H00982E  
4H00982E 4681A20004F  
5210A21341A  
4H00982E  
552102-1 TUBE, CAPILLARY BEND  
5424AR3582H 5424AR3582H 5424AR3582H 5424AR3582C  
R
5424AR7208M  
552102-2 TUBE,CAPILLARY BEND  
552111 TUBE ASSEMBLY, CAPILLARY  
552116 TUBE ASSEMBLY, REVERSING  
552201 VALVE, CHECK  
-
-
-
-
-
5210A20595F  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
5211A30275D 5211A30275D 5211A30275D 5211A30337A 5211A20117E 5211A20133Z  
-
-
-
-
5211A20116C 5211A21027B  
3H01552F  
5220AR3084A 5220AR3084E  
-
-
-
-
-
552202 VALVE, REVERSING  
-
-
-
-
552203-1 VALVE, SERVICE  
2H02479F  
2A00393U  
2H02479F  
2A00393U  
2H02479F  
2A00393U  
2H02479F  
2A00393U  
2H02479H  
2A00393U  
2H02479N  
2A00393Z  
552203-2 VALVE, SERVICE  
554031 CONDENSER ASSEMBLY, BENT  
554160 COMPRESSOR SET  
5403AR2870F 5403AR2870M 5403AR2870F 5403AR2870P 5403A20028H 5403A20059B  
5416A20013L 5416A20013L 5416A20013L 5416A20013J 5416A20013C 5417A20012H  
5900AR1266A 5900AR1266A 5900AR1266A 5900AR1266A 5901A10004A 5900AR1266A  
559010 FAN ASSEMBLY, PROPELLER  
561410 COIL ASSEMBLY, REVERSING VALVE  
567502 O.L.P  
-
-
-
-
3A02028Y  
3A02028Y  
6750A30001C 6750A30001C 6750A30001C 6750A30001C 6750A30001C 6750A30001C  
4995AR2566B 4995AR2566B 4995AR2566B 4995AR2566E 4995A20083F 4995A10032J  
649950 CONTROL BOX ASSEMBLY, OUTDOOR  
W0CZZ CAPACITOR, DRAWING  
2H01451P  
2H01451P  
2H01451P  
2H01451P  
2H01451P  
2H01451P  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
-76-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Outdoor)  
PART No.  
LOCATION  
DESCRIPTION  
REMARKS  
No.  
LS-Q096ABL LS-Q096BBG LS-Q096BEL LS-Q096AHG LS-Q096ABG LS-Q096AEM  
3041A20008K 3041A20008K 3041A20008K 3041A20008K 3041A20008K 3041A20008K  
430410 BASE ASSEMBLY, OUTDOOR  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
435511 COVER ASSEMBLY, CONTROL(OUTDOOR) 3551A30023E 3551A30023E 3551A30023E 3551A30023E 3551A30023E 3551A30023E  
437210 PANEL ASSEMBLY, FRONT(OUTDOOR)  
437212 PANEL ASSEMBLY, REAR(OUTDOOR)  
447910 BARRIER ASSEMBLY, OUTDOOR  
546810 MOTOR ASSEMBLY, OUTDOOR  
550140 ISOLATOR, COMP  
3721A20027A 3721A20027A 3721A20027A 3721A20027A 3721A20027A 3721A20027A  
3721A20026B 3721A20026B 3721A20026B 3721A20026B 3721A20026B 3721A20026B  
4791A30002B 4791A30002B 4791A30002B 4791A30002B 4791A30002B 4791A30002B  
4681A20004J 4681A20004J 4681A20004J 4681A20004J 4681A20004J 4681A20004J  
4H00982E  
4H00982E  
4H00982E  
4H00982E  
4H00982E  
4H00982E  
552111 TUBE ASSEMBLY, CAPILLARY  
552116 TUBE ASSEMBLY, REVERSING  
552201 VALVE, CHECK  
5211A20117C 5211A20117C 5211A20117C 5211A20117C 5211A20117C 5211A20117E  
5211A20116A 5211A20116A 5211A20116A 5211A20116A 5211A20116A 5211A20116C  
3H01552F  
3H01552F  
3H01552F  
3H01552F  
3H01552F  
3H01552F  
552202 VALVE, REVERSING  
5220AR3084A 5220AR3084A 5220AR3084A 5220AR3084A 5220AR3084A 5220AR3084A  
552203-1 VALVE, SERVICE  
2H02479H  
2H02479H  
2H02479H  
2H02479H  
2H02479H  
2H02479H  
2A00393U  
552203-2 VALVE, SERVICE  
2A00393U  
2A00393U  
2A00393U  
2A00393U  
2A00393U  
552102-1 TUBE,CAPILLARY BEND  
552102-2 TUBE,CAPILLARY BEND  
554031 CONDENSER ASSEMBLY, BENT  
554160 COMPRESSOR  
-
-
-
-
-
-
-
-
-
-
5210A21341A  
5424AR7208M  
5403A20028H 5403A20028H 5403A20028H 5403A20028B 5403A20028B 5403A20028H  
5416A20013C 5416A20013C 5416A20013C 5416A20013C 5416A20013C 5416A20013C  
5901A10004A 5901A10004A 5901A10004A 5901A10004A 5901A10004A 5901A10004A  
559010 FAN ASSEMBLY, PROPELLER  
561410 COIL ASSEMBLY, REVERSING VALVE  
567502 O.L.P  
3A02028Y  
-
3A02028Y  
-
3A02028Y  
-
3A02028Y  
-
3A02028Y  
-
3A02028Y  
6750A30001C  
649950 CONTROL BOX ASSEMBLY, OUTDOOR  
W0CZZ CAPACITOR, DRAWING  
435301 GRILLE, DISCHARGE  
4995A20083F 4995A20083F 4995A20083F 4995A20083F 4995A20083F 4995A20083F  
2H01451P 2H01451P 2H01451P 2H01451P 2H01451P 2H01451P  
3530A20006B 3530A20006B 3530A20006B 3530A20006B 3530A20006B 3530A20006B  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
-77-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Outdoor)  
PART No.  
LOCATION  
DESCRIPTION  
REMARKS  
No.  
LS-Q096BDG  
LS-Q096BDL  
3041A20008K 3041AR2415K 3041AR2415K 3041AR2415K 3041AR2415K 3041A20008K  
LS-Q096AEL LS-Q096ADG LS-Q096ADL  
LS-Q096AAG LS-Q096BEG  
430410  
435301  
435301  
435511  
437210  
437212  
447910  
546810  
550140  
BASE ASSEMBLY,OUTDOOR  
GRILLE,DISCHARGE  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
-
-
-
-
-
-
3530A20006B  
-
GRILLE,DISCHARGE  
3530A20006B 3530A20006B 3530A20006B 3530A20006B  
COVER ASSEMBLY,CONTROL(OUTDOOR)  
PANEL ASSEMBLY,FRONT(OUTDOOR)  
PANEL ASSEMBLY,REAR(OUTDOOR)  
BARRIER ASSEMBLY,OUTDOOR  
MOTOR ASSEMBLY,OUTDOOR  
ISOLATOR,COMP  
3551A30023E 4994AR3492B 4994AR3492B 4994AR3492B 4994AR3492B 3551A30023E  
3721A20027A 3531AR2512R 3531AR2512R 3531AR2512R 4994AR3492B 3721A20027A  
3721A20026B 3530AR0058B 3530AR0058B 3530AR0058B 3530AR0058B 3721A20026B  
-
-
-
-
-
4791A30002B  
4681A20004J 4681A20004F 4681A20004F 4681A20004F 4681A20004F 4681A20004J  
4H00982E 4H00982E 4H00982E 4H00982E 4H00982E 4H00982E  
5210A21341A 5424AR3582H 5424AR3582H 5424AR3582H 5424AR3582H 5210A21341A  
5424AR7208M 5424AR7208M  
5211A20117C 5211A30275D 5211A30275D 5211A30275D 5211A30275D 5211A20117E  
552102-1 TUBE,CAPILLARY BEND  
552102-1 TUBE,CAPILLARY BEND  
-
-
-
-
552111  
552116  
552201  
552202  
TUBE ASSEMBLY,CAPILLARY  
TUBE ASSEMBLY,REVERSING  
VALVE,CHECK  
5211A20116A  
3H01552F  
-
-
-
-
5211A20116C  
3H01552F  
-
-
-
-
VALVE,REVERSING  
5220AR3084A  
2H02479H  
-
-
-
-
5220AR3084A  
2H02479H  
552203-1 VALVE,SERVICE  
552203-2 VALVE,SERVICE  
2H02479F  
2A00393U  
2H02479F  
2A00393U  
2H02479F  
2A00393U  
2H02479F  
2A00393U  
2A00393U  
2A00393U  
554031  
554160  
559010  
561410  
567502  
649950  
CONDENSER ASSY,BENT  
5403A20028H 5403AR2870M 5403AR2870M 5403AR2870M 5403AR2870M 5403A20028H  
5416A20013C 5416A20013L 5416A20013L 5416A20013L 5416A20013L 5416A20013C  
5901A10004A 5900AR1266A 5900AR1266A 5900AR1266A 5900AR1266A 5901A10004A  
COMPRESSOR  
FAN ASSEMBLY,PROPELLER  
COIL ASSEMBLY,REVERSING VALVE  
O.L.P  
3A02028Y  
-
-
-
-
3A02028Y  
6750A30001C 6750A30001C 6750A30001C 6750A30001C 6750A30001C 6750A30001C  
4995A20083F 4995AR2566F 4995AR2566F 4995AR2566F 4995AR2566F 4995A20083F  
CONTROL BOX ASSEMBLY,OUTDOOR  
W0CZZ CAPACITOR,DRAWING  
2H01451P  
2H01451P  
2H01451P  
2H01451P  
2H01451P  
2H01451P  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
-78-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Outdoor)  
PART No.  
LOCATION  
DESCRIPTION  
REMARKS  
No.  
LS-Q082BAM LS-Q082AAL LS-Q082ACG LS-Q082ACL LS-Q082ACM  
430410 BASE ASSY,WELD[OUTDOOR]  
3041AR2415E  
3041AR2415E  
4994AR3492B  
3531AR2512R  
3530AR0058B  
4681A20068A  
4H00982E  
3041AR2415E  
4994AR3492B  
3531AR2512R  
3530AR0058B  
4681A20068A  
4H00982E  
3041AR2415E  
4994AR3492B  
3531AR2512R  
3530AR0058B  
4681A20068A  
4H00982E  
3041AR2415E  
4994AR3492B  
3531AR2512R  
3530AR0058B  
4681A20068A  
4H00982E  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
435511 COVER ASSEMBLY,CONTROL(OUTDOOR) 4994AR3492B  
437210 GRILLE ASSEMBLY,FRONT(OUTDOOR)  
437212 PANEL ASSEMBLY,REAR(OUTDOOR)  
546810 MOTOR ASSEMBLY,OUTDOOR  
550140 ISOLATOR,COMP  
3531AR2512R  
3530AR0058B  
4681A20068A  
4H00982E  
552102-1 TUBE,CAPILLARY BEND  
552102-2 TUBE,CAPILLARY BEND  
552111 TUBE ASSY,CAPILLARY  
552203-1 VALVE,SERVICE  
5424AR3582C  
-
5424AR3582C  
-
5424AR3582C  
-
5424AR3582C  
-
5424AR3582C  
-
5211A30337A  
2H02479F  
5211A30337A  
2H02479F  
5211A30337A  
2H02479F  
5211A30337A  
2H02479F  
5211A30337A  
2H02479F  
552203-2 VALVE,SERVICE  
2A00393U  
2A00393U  
2A00393U  
2A00393U  
2A00393U  
554031 CONDENSER ASSEMBLY,BENT  
554160 COMPRESSOR  
5403AR2870P  
5416A20013J  
5900AR1266A  
6750A30001D  
4995AR2566E  
6120AR2194G  
5403AR2870P  
5416A20013J  
5900AR1266A  
6750A30001D  
4995AR2566E  
6120AR2194G  
5403AR2870H  
5416A20013J  
5900AR1266A  
6750A30001D  
4995AR2566E  
6120AR2194G  
5403AR2870H  
5416A20013J  
5900AR1266A  
6750A30001D  
4995AR2566E  
6120AR2194G  
5403AR2870H  
5416A20013J  
5900AR1266A  
6750A30001D  
4995AR2566E  
6120AR2194G  
559010 FAN ASSEMBLY,PROPELLER  
567502 O.L.P  
649950 CONTROL BOX ASSEMBLY,OUTDOOR  
W0CZZ CAPACITOR,DRAWING  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
-79-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Outdoor)  
PART No.  
LOCATION  
No.  
DESCRIPTION  
REMARKS  
LS-C082QMA0  
LS-C082QNAO  
LS-C096QGL0  
430410  
435301  
435511  
437210  
437212  
546810  
550140  
552102  
BASE ASSY,WELD[OUTDOOR]  
GRILLE,DISCHARGE  
3041AR2415E  
-
3041AR2415E  
-
3041AR2415K  
-
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
COVER ASSEMBLY,CONTROL(OUTDOOR)  
GRILLE ASSEMBLY,FRONT(OUTDOOR)  
PANEL ASSEMBLY,REAR(OUTDOOR)  
MOTOR ASSEMBLY,OUTDOOR  
ISOLATOR,COMP  
4994AR3492B  
3531AR2512R  
3530AR0058B  
4681A20068K  
4H00982E  
5424AR3582C  
-
4994AR3492B  
3531AR2512R  
3530AR0058B  
4681A20068K  
4H00982E  
5424AR3582C  
-
4994AR3492B  
3531AR2512R  
3530AR0058B  
4681A20004F  
4H00982E  
5424AR3582H  
-
TUBE,CAPILLARY BEND  
552102-1 TUBE,CAPILLARY BEND  
552102-2 TUBE,CAPILLARY BEND  
-
-
-
552111  
552116  
552201  
552202  
TUBE ASSY,CAPILLARY  
TUBE ASSY,REVERSING  
VALVE,CHECK  
5211A30337A  
-
5211A30337A  
-
5211A30275D  
-
-
-
-
VALVE,REVERSING  
-
-
-
552203-1 VALVE,SERVICE  
552203-2 VALVE,SERVICE  
2H02479F  
2A00393U  
5403AR2870H  
5416A20013J  
5900AR1266A  
-
2H02479F  
2A00393U  
5403AR2870H  
5416A20013J  
5900AR1266A  
-
2H02479F  
2A00393U  
5403AR2870M  
5416A20013L  
5900AR1266A  
-
554031  
554160  
559010  
561410  
567502  
649950  
W0CZZ  
CONDENSER ASSEMBLY,BENT  
COMPRESSOR  
FAN ASSEMBLY,PROPELLER  
COIL ASSY,REVERSING VALVE  
O.L.P  
6750A30001D  
4995AR2566N  
6120AR2194G  
6750A30001D  
4995AR2566N  
6120AR2194G  
6750A30001C  
4995AR2566F  
2H01451P  
CONTROL BOX ASSEMBLY,OUTDOOR  
CAPACITOR,DRAWING  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
-80-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List(Outdoor)  
PART No.  
LOCATION  
No.  
DESCRIPTION  
REMARKS  
LS-C096QLA0  
LS-C096QNA0  
LS-H096QGL1  
430410 BASE ASSY,WELD[OUTDOOR]  
435301 GRILLE,DISCHARGE  
3041AR2415K  
-
3041AR2415K  
-
3041A20016A  
3530A10059G  
3551A30023Q  
3720A10171A  
3720A10172A  
4681A20121A  
4H00982E  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
435511 COVER ASSEMBLY,CONTROL(OUTDOOR)  
437210 GRILLE ASSEMBLY,FRONT(OUTDOOR)  
437212 PANEL ASSEMBLY,REAR(OUTDOOR)  
546810 MOTOR ASSEMBLY,OUTDOOR  
550140 ISOLATOR,COMP  
4994AR3492B  
3531AR2512R  
3530AR0058B  
4681A20004F  
4H00982E  
5424AR3582H  
-
4994AR3492B  
3531AR2512R  
3530AR0058B  
4681A20004F  
4H00982E  
5424AR3582H  
-
552102 TUBE,CAPILLARY BEND  
552102-1 TUBE,CAPILLARY BEND  
552102-2 TUBE,CAPILLARY BEND  
552111 TUBE ASSY,CAPILLARY  
552116 TUBE ASSY,REVERSING  
552201 VALVE,CHECK  
5210A20595F  
-
-
-
-
5211A30275D  
-
5211A30275D  
-
5211A20133Z  
5211A21027B  
-
-
-
552202 VALVE,REVERSING  
-
-
5220AR3084E  
2H02479P  
552203-1 VALVE,SERVICE  
2H02479F  
2A00393U  
5403AR2870M  
5416A20013L  
5900AR1266A  
-
2H02479F  
2A00393U  
5403AR2870M  
5416A20013L  
5900AR1266A  
-
552203-2 VALVE,SERVICE  
5220A20040A  
5403A20059F  
5416A20013L  
5900AR1266A  
3A02028Y  
554031 CONDENSER ASSEMBLY,BENT  
554160 COMPRESSOR  
559010 FAN ASSEMBLY,PROPELLER  
561410 COIL ASSY,REVERSING VALVE  
567502 O.L.P  
6750A30001C  
4995AR2566F  
2H01451P  
6750A30001C  
4995AR2566F  
2H01451P  
6750A30001C  
4995A10032J  
2H01451P  
649950 CONTROL BOX ASSEMBLY,OUTDOOR  
W0CZZ CAPACITOR,DRAWING  
NOTE) Please ensure GCSC since these parts may be changed depending upon the buyer's request.  
*
(GCSC WEBSITE http://biz.LGservice.com)  
-81-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
April, 2004  
P/No.: 3828A20178A  
Printed in Korea  
Download from Www.Somanuals.com. All Manuals Search And Download.  

LG Electronics Air Conditioner W081CA SG2 User Manual
Life Fitness Bicycle Upright and Recumbent Bike User Manual
Lightwave Communications Switch USB Wizard User Manual
Linn Speaker Linn Melodik User Manual
Mackie Home Theater Server HDR 24 96 User Manual
Magnavox Water Heater MPC250 User Manual
Makita Battery Charger DC1414 MJ User Manual
Maxtor DVR SC324 User Manual
Maytag Washer MAV5000 User Manual
Merco Savory TV Mount PDC 2418 User Manual