| Industrial 3-Port Fast Ethernet   Media Converter Switches   KSD-103-A series   KSD-103-B series   Installation Guide   DOC.081111   Download from Www.Somanuals.com. All Manuals Search And Download.   The information contained in this document is subject to change without prior notice. Copyright (C)   All Rights Reserved.   TRADEMARKS   Ethernet is a registered trademark of Xerox Corp.   FCC NOTICE   This device complies with Class B Part 15 the FCC Rules. Operation is subject to the following two   conditions: (1) This device may not cause harmful interference, and (2) this device must accept any   interference received including the interference that may cause.   CE NOTICE   Marking by the symbol indicates compliance of this equipment to the EMC directive of the European   Community. Such marking is indicative that this equipment meets or exceeds the following technical   standards:   EMC Class B   EN 50081-1/1992 :EN55022:1994/A1:1995/A2:1997 Class B   EN61000-3-2:2000   EN61000-3-3:1995/A1:2001   EN 55024:1998/A1:2001   IEC 61000-4-2:1995   IEC 61000-4-3:1995   IEC 61000-4-4:1995   IEC 61000-4-5:1995   IEC 61000-4-6:1996   IEC 61000-4-8:1993   IEC 61000-4-11:1994   3/20   Download from Www.Somanuals.com. All Manuals Search And Download.   Table of Contents   1. Introduction ................................................................................................................................5   2. Installation ................................................................................................................................10   3. Making LAN Connections........................................................................................................16   3.1 Making Copper Port (RJ-45) Connections...........................................................16   3.2 Making Fiber Connections...................................................................................16   5. Appendix...................................................................................................................................19   5.1 Model Definition...................................................................................................19   4/20   Download from Www.Somanuals.com. All Manuals Search And Download.   1. Introduction   The industrial rated KSD-103 Fast Ethernet switch series supports three switching-base segment   communications and benefit the following applications and make fiber deployment easier :   ꢀ Copper to fiber bridging converter   ꢀ Multimode fiber to single mode fiber bridging converter   ꢀ Fiber cable extender   ꢀ Cascaded fiber networking   Depending on the types of the network ports, two different model series are defined as follows:   Model   Copper Port (RJ-45)   2 ports   Fiber Port   1 port   KSD-103-A   KSD-103-B   1 port   2 ports   The switch also provide the following advantages:   Plug and Play   No configuration is required in using the switches. With the featured auto-negotiation function, the   switches can detect and configure the connection speed and duplex automatically for the copper ports.   The switches also provide auto MDI/MDI-X function, which can detect the connected cable and switch   the transmission wire pair and receiving pair automatically. This auto-crossover function can simplify   the type of network cables used.   Industrial Features   For industrial environment, the devices are designed with the following enhanced features exceeding   that of commercial Ethernet switches:   5/20   Download from Www.Somanuals.com. All Manuals Search And Download.   ꢀ ꢀ High and wide operating Temperature   Power input interface: Industrial screw terminal block and DC power jack for external   commercial power adapter as option   ꢀ ꢀ Screw panel and DIN rail mounting support for industrial enclosure   Industrial-rated Emission and Immunity performance   1.1 Features   ꢀ ꢀ ꢀ ꢀ ꢀ ꢀ ꢀ ꢀ ꢀ Provide 3 switching-base network segments   Auto MDI/MDI-X crossover function on the TP copper port   Support IEEE 802.3x flow control for full-duplex operation   Support Back-pressure flow control for half-duplex operation   Wide operating temperature range for temperature critical environment   Support DIN-rail mounting and panel mounting   Provide two power input types to meet more application needs   Accept wide power input voltage range for application flexibility   Industrial-rated Emission and Immunity performance   1.2 Product Panels   The following figure illustrates the faces of the switches:   KSD-103-A   6/20   Download from Www.Somanuals.com. All Manuals Search And Download.   KSD-103-B   1.3 Specifications   Copper Ports   Compliance   IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX   Shielded RJ-45 jacks   Connectors   Pin assignments   Configuration   Auto MDI/MDI-X detection   Auto-negotiation   Transmission rate   Duplex support   Network cable   10Mbps, 100Mbps   Full/Half duplex   Cat.5 UTP up to 100 meters   Fiber Ports   Connectors   ST, SC, VF-45, Bi-Directional SC (model dependent)   100Mbps, Full duplex   Configuration   Network cables   Eye safety   MMF 50/125 60/125μm, SMF 9/125μm   IEC 825 compliant   Far end fault support   Enabled   Switch Functions   MAC Addresses Table 1K entries   7/20   Download from Www.Somanuals.com. All Manuals Search And Download.   Forwarding & filtering Non-blocking, full wire speed   Switching technology Store and forward   Maximum packet length 1536 bytes max.   Flow control   IEEE 802.3x pause frame base for full duplex operation   Back pressure for half duplex operation   Protection design   Broadcast Storm   DC Power Interface   Interface   Screw-type terminal block   1. Two pairs for power wire cascading   2. One pair for alarm relay output   DC Jack (-D6.3mm/+D2.0mm)   Operating voltages   Power consumption   +7V ~ +50V(+5%)   KSD-103-A   2.1W max.@+7.5VDC input, 3.5W max.@+50VDC input   KSD-103-B   3.3W max.@+7.5VDC input, 4W max.@+50VDC input   DIP SW   KSD-103-A   SW1   Broadcast storm protection setting   SW2   Fiber port FX link down alarm setting   KSD-103-B   SW1   Broadcast storm protection setting   Fiber port FX1 link down alarm setting   Fiber port FX2 link down alarm setting   SW2   SW3   Mechanical   Dimension (base)   Weight   W 28mm x D 82mm x H 95mm   250g   Housing   Enclosed metal with no fan   DIN-rail mounting, Panel mounting   Mounting support   Environmental   o o Operating temperature -20 C ~ 70 C   o o Storage temperature   Relative humidity   -20 C ~ 85 C   5% ~ 90%   8/20   Download from Www.Somanuals.com. All Manuals Search And Download.   Certificate   FCC   Part 15 Class B   EMI EN50081-1 Class B   EMS EN55024   EN 60950   CE/EMC   CE/LVD Safety   EN 50081-1/1992 :   EN55022:1994/A1:1995/A2:1997   EN61000-3-2:2000   EN61000-3-3:1995/A1:2001   EN 55024:1998/A1:2001   IEC 61000-4-2:1995 ESD Test   IEC 61000-4-3:1995 RS Test   IEC 61000-4-4:1995 EFT/BURST Test   IEC 61000-4-5:1995 Surge Test   IEC 61000-4-6:1996 CS Test   IEC 61000-4-8:1993 Magnetic Field   IEC 61000-4-11:1994 Voltage Int. Dips   9/20   Download from Www.Somanuals.com. All Manuals Search And Download.   2. Installation   2.1 Unpacking   Check that the following components have been included:   ꢀ Information CD   ꢀ The device unit   ꢀ DIN-rail mounting bracket   If any item is found missing or damaged, please contact your local reseller for replacement.   The following are available optional accessories:   ꢀ Panel Mounting Bracket   The bracket is used for mounting the device on a panel surface.   ꢀ Commercial-rated AC power adapters:   - Rated input AC120V/60Hz, AC230V/50Hz, AC100V/50-60Hz, AC240V/50Hz   - Rated output DC7.5V 1A, DC7.5V 1.2A   ꢀ High temperature AC power adapters:   - Rated -10 oC ~ 60oC, AC100-240V/50-60Hz DC12V 1A for USA and Germany   The adapters are used for supplying DC power to the switch via DC power jack interface.   2.2 Safety Cautions   To reduce the risk of bodily injury, electrical shock, fire, and damage to the product, observe the   following precautions.   ꢀ ꢀ ꢀ ꢀ Do not service any product except as explained in your system documentation.   Opening or removing covers may expose you to electrical shock.   Only a trained service technician should service components inside these compartments.   If any of the following conditions occur, unplug the product from the electrical outlet and replace   the part or contact your trained service provider:   - The power cable, extension cable, or plug is damaged.   - An object has fallen into the product.   - The product has been exposed to water.   - The product has been dropped or damaged.   - The product does not operate correctly when you follow the operating instructions.   ꢀ ꢀ Do not push any objects into the openings of your system. Doing so can cause fire or electric shock   by shorting out interior components.   Operate the product only from the type of external power source indicated on the electrical ratings   10/20   Download from Www.Somanuals.com. All Manuals Search And Download.   label. If you are not sure of the type of power source required, consult your service provider or   local power company.   2.3 DIN-Rail Mounting   In the product package, a DIN-rail bracket is installed on the device for mounting the device in a   industrial DIN-rail enclosure.   The steps to mount the device onto a DIN rail are:   1. Install the mounting bracket onto the device unit as shown below:   2. Attach bracket to the lower edge of the DIN rail and push the unit upward a little bit until the   bracket can clamp on the upper edge of the DIN rail.   3. Clamp the unit to the DIN rail and make sure it is mounted securely.   4. Make sure that there are proper heat dissipation from and adequate ventilation around the device.   11/20   Download from Www.Somanuals.com. All Manuals Search And Download.   The final mechanical dimensions after installing DIN rail mounting bracket are:   2.4 Panel Mounting   The product is provided with an optional bracket for panel mounting. The bracket supports mounting   the device on a plane surface securely. The mounting steps are:   1. Install the mounting bracket on the device unit. Screw the bracket on the device unit.   2. Screw the device unit on a panel. Make sure that there are proper heat dissipation from and   adequate ventilation around the device. Do not place heavy objects on the device.   The screw locations and final dimension are shown below:   12/20   Download from Www.Somanuals.com. All Manuals Search And Download.   2.5 Applying Power   The power specifications of the device are:   Operating Voltage   +7 ~ +50VDC   Power Consumption   4W max. @+50VDC   Using Terminal Blocks   Either DC1 interface or DC2 interface can be used to receive DC power from an external power   system. Or, DC2 also can be used to deliver the power received on DC1 to next device in cascading   way.   DC1   DC1   DC2   DC2   +Vdc Positive (+) terminal   -Vdc Negative (-) terminal   +Vdc Positive (+) terminal   -Vdc Negative (-) terminal   Three 2P terminal plugs are provided together with the device. Two of the three plugs are used for   DC1 and DC2 interfaces respectively. The plug is shown below:   2 Power wires: 24 ~ 12AWG (IEC 0.5~2.5mm )   Install the power source wires with the plug properly. Screw the wire with plug securely. Then, plug in   DC1 contacts.   13/20   Download from Www.Somanuals.com. All Manuals Search And Download.   If cascading the power to next device is needed, install the power wires and plug for another switch.   Then, use DC2 contacts.   Note: Only up to four device units can be cascaded to receive power from one main power input   source.   Using DC Power Jack   DC Jack Connector: D 6.3mm   D 2.0mm   AC Power Adapters: Optional power adapters are available for purchasing.   Connect power adapter DC plug to the DC power jack of the converter before connecting to the AC   outlet. Connect the power adapter to the AC outlet.   Note: Before you begin the installation, check the AC voltage of your area. The AC power adapter that   is used to supply the DC power for the unit should have the AC voltage matching the   commercial power voltage in your area.   2.6 Failure Alarm Relay Output   The device provides a relay output to report failure events to a remote alarm monitoring system. The   replay output is provided with two contacts labeled PF+ and PF- in the terminal block interface.   14/20   Download from Www.Somanuals.com. All Manuals Search And Download.   Use the provided 2P terminal plug for signal wiring and plug into the PF+/- contacts.   Relay Output   Indication   Normal PF+ and PF- contacts shorted   Alarm PF+ and PF- contacts open   Alarm Events:   ꢀ Input power failure   ꢀ Specific fiber port link down (To specify the fiber ports, use the DIP SW located on bottom.)   KSD-103-A   SW1   SW2   ON Enable broadcast storm protection   OFF Disable broadcast storm protection   ON Enable FX port link down alarm   OFF Disable FX port link alarm   KSD-103-B   SW1   SW2   SW3   ON Enable broadcast storm protection   OFF Disable broadcast storm protection   ON Enable FX1 port link down alarm   OFF Disable FX1 port link alarm   ON Enable FX2 port link down alarm   OFF Disable FX2 port link alarm   Note: Be sure the voltage applied on PF+/- contacts is within the specification of 30VDC/1A max. or   120VAC/0.5A max.   15/20   Download from Www.Somanuals.com. All Manuals Search And Download.   3. Making LAN Connections   3.1 Making Copper Port (RJ-45) Connections   The copper ports support the following connection types and distances:   Network Cables   10BASE-T:   2-pair UTP Cat. 3,4,5 , EIA/TIA-568B 100-ohm   100BASE-TX: 2-pair / 4-pair UTP Cat. 5, EIA/TIA-568B 100-ohm   Link distance: Up to 100 meters   Auto MDI/MDI-X Function   This function allows the port to auto-detect the twisted-pair signals and adapts itself to form a valid   MDI to MDI-X connection with the remote connected device automatically. No matter a straight   through cable or crossover cable connected, the ports can sense the receiving pair automatically and   configure self to match the rule for MDI to MDI-X connection. It simplifies the cable installation by   using only straight-through cables.   Auto-negotiation Function   The ports are featured with auto-negotiation function and full capability to support connection to any   Ethernet devices. The port performs a negotiation process for the speed and duplex configuration with   the connected device automatically when each time a link is being established. If the connected device   is also auto-negotiation capable, both devices will come out the best configuration after negotiation   process. If the connected device is incapable in auto-negotiation, the switch will sense the speed and   use half duplex for the connection.   3.2 Making Fiber Connections   The fiber ports operate on 100Mbps and full duplex. For different fiber connections, several alternative   models can be selected for different fiber connections. The following figure illustrates a connection   example between two SC fiber ports:   A variety of fiber options and the associated optical specifications are provided as listed in   Appendix-1.   Network Cables   Multimode (MMF) - 50/125, 62.5/125   Single mode (SMF) - 9/125   16/20   Download from Www.Somanuals.com. All Manuals Search And Download.   3.3 LED Indication   KSD-103-A   KSD-103-B   LED   Function   State   ON   Interpretation   PWR   Power status   The power is supplied to the device.   The power is not supplied to the device.   Port link is established. (No traffic)   Port link is up and there is traffic.   Port link is down.   OFF   UTPx   FXx   Copper port link status ON   BLINK   OFF   Fiber port link status   ON   Port link is established. (No traffic)   Port link is up and there is traffic.   Port link is down.   BLINK   OFF   Note: UTPx = UTP UTP1 UTP, FXx = FX FX1 FX2   17/20   Download from Www.Somanuals.com. All Manuals Search And Download.   4. Applications   4.1 Application in Industrial Networks   The following figure illustrates an application example in an industrial network. Four devices are   cascaded by fiber cables.   4.2 Copper to Fiber Bridging Media Converter Application   4.3 Bridging Multimode to Single Mode Fiber Converter Application   18/20   Download from Www.Somanuals.com. All Manuals Search And Download.   5. Appendix   5.1 Model Definition   KSD-103-A   Model Ext. FX Connector   Cable   MMF   MMF   MMF   SMF   SMF   SMF   SMF   SMF   SMF   SMF   Ref. Distance Operating Temperature   -T   -C   Duplex ST   Duplex SC   Duplex SC   Duplex SC   Duplex SC   Duplex SC   Duplex SC   Duplex SC   BiDi SC   2km   2km   -10 ~ 70oC   -10 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -C1   2km   -SA2   -SL2   -SL3   -SL4   -SL6   -W3515   -W5315   20km   20km   30km   40km   60km   15 ~ 20km   15 ~ 20km   BiDi SC   KSD-103-B   Model Ext. FX Ports   FX2 Connector   Duplex ST   Duplex SC   Duplex SC   Duplex SC   Duplex SC   Duplex SC   Duplex SC   Duplex SC   BiDi SC   Cable   MMF   MMF   MMF   SMF   SMF   SMF   SMF   SMF   SMF   SMF   MMF   SMF   Ref. Distance Operating Temperature   -T   -C   FX1, FX2   FX1, FX2   FX1, FX2   FX1, FX2   FX1, FX2   FX1, FX2   FX1, FX2   FX1, FX2   FX1, FX2   FX1, FX2   FX1   2km   2km   -10 ~ 70oC   -10 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -20 ~ 70oC   -C1   2km   -SA2   -SL2   -SL3   -SL4   -SL6   -W3515   -W5315   20km   20km   30km   40km   60km   15 ~ 20km   15 ~ 20km   2km   BiDi SC   Duplex SC   Duplex SC   -C1Sl2   FX2   20km   19/20   Download from Www.Somanuals.com. All Manuals Search And Download.   5.2 Optical Specifications   KSD-103-A   Model Ext.   -T   FX Port   FX   Wavelength   1310nm   1310nm   1310nm   1310nm   1310nm   1310nm   1310nm   1310nm   1310nm   1550nm   TX Power   -19 ~ -14dBm   -19 ~ -14dBm   -20 ~ -14dBm   -15 ~ -8dBm   -15 ~ -8dBm   -15 ~ -8dBm   -5 ~ 0dBm   Sensitivity RX Max. Power   -31dBm   -31dBm   -31dBm   -31dBm   -30dBm   -34dBm   -34dBm   -35dBm   -31dBm   -31dBm   -14dBm   -14dBm   0dBm   -7dBm   0dBm   0dBm   0dBm   0dBm   0dBm   0dBm   -C   FX   -C1   FX   -SA2   -SL2   FX   FX   -SL3   FX   -SL4   FX   -SL6   FX   -5 ~ 0dBm   -W3515   -W5315   FX   -14 ~ -8dBm   -14 ~ -8dBm   FX   KSD-103-B   Model Ext. FX Ports   Wavelength   1310nm   1310nm   1310nm   1310nm   1310nm   1310nm   1310nm   1310nm   1310nm   1550nm   1550nm   1310nm   1310nm   1310nm   TX Power   -19 ~ -14dBm   -19 ~ -14dBm   -20 ~ -14dBm   -15 ~ -8dBm   -15 ~ -8dBm   -15 ~ -8dBm   -5 ~ 0dBm   Sensitivity RX Max. Power   -T   FX1, FX2   FX1, FX2   FX1, FX2   FX1, FX2   FX1, FX2   FX1, FX2   FX1, FX2   FX1, FX2   FX1   -31dBm   -31dBm   -31dBm   -31dBm   -30dBm   -34dBm   -34dBm   -35dBm   -31dBm   -31dBm   -31dBm   -31dBm   -31dBm   -30dBm   -14dBm   -14dBm   0dBm   -7dBm   0dBm   0dBm   0dBm   0dBm   0dBm   0dBm   0dBm   0dBm   0dBm   0dBm   -C   -C1   -SA2   -SL2   -SL3   -SL4   -SL6   -5 ~ 0dBm   -14 ~ -8dBm   -14 ~ -8dBm   -14 ~ -8dBm   -14 ~ -8dBm   -20 ~ -14dBm   -15 ~ -8dBm   -W3515   -W5315   -C1Sl2   FX2   FX1   FX2   FX1   FX2   20/20   Download from Www.Somanuals.com. All Manuals Search And Download.   |