KAC-PS501F
4-CHANNEL POWER AMPLIFIER
INSTRUCTION MANUAL
© B64-1444-00 (EM)
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Self-tapping screw
Cooling fan
Exhaust outlet
Air inlet
Installation board, etc.
(thickness : 15 mm or more)
• Since the power amplifier has no parts which require operation, it can be installed at a position
away from the driver’s seat without any hindrances.
As generally accepted positions for its installation, places such as inside the trunk, etc. can be
considered.
• Use the extension cables. (Optional.)
Length
0.5m
1m
2m
4m
5m
6m
Type
RCA cable
RCA cable (ø7mm)
RCA cable (ø12mm)
CA-2SL
CA-12SL CA-22SL
CA-52SL
CA-53WL
CA-3WL CA-13WL CA-23WL
CA-5W CA-15W CA-25W
CA-45W
CA-65W
2CAUTION
• Do not install the unit under the carpet. Otherwise heat build-up occurs and the unit may be
damaged.
• Install this unit in a location which allows heat to easily dissipate.
Once installed, do not place any object on top of the unit.
• The surface temperature of the amplifier will become hot during use. Install the amplifier in a
place where people, resins, and other substances that are sensitive to heat will not come into
contact with it.
• This unit has cooling fans to decrease the internal temperature. Be careful not to block the
cooling fan openings when installing the unit. Blocking these openings will inhibit the cooling of
the internal temperature and result in malfunction.
• When making a hole under a seat, inside the trunk, or somewhere else in the vehicle, check
that there is nothing hazardous on the opposite side such as a gasoline tank, brake pipe, or
wiring harness, and be careful not to cause scratches or other damage.
• Do not install near the dashboard, rear tray, or air bag safety parts.
• The installation to the vehicle should securely fasten the unit to a place in which it will not
obstruct driving. If the unit comes off due to a shock and hits a person or safety part, it may
cause injury or an accident.
• After installing the unit, check to make sure that electrical equipment such as the brake lamps,
turn signal lamps and windshield wipers operate normally.
English 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Controls
SPEAKER OUTPUT
A
B
LEFT
BRIDGED
RIGHT
FUSE(20A×4)
A
B
BATT.
GND
#
@
CONTROL
A
INPUT SENSITIVITY(V)
2
3
1
4
0.5
0.2
1
2 3
4
5
FREQ (Hz)
5
(MIN)(MAX)
OFF 25Hz
15Hz
HPF LPF
OFF
STEREO MONO AB
A
INFRASONIC
FILTER
OPERATION INPUT SELECT
MONO
CONTROL
CONTROL
A
B
L
L
INPUT SENSITIVITY(V)
2
INPUT SENSITIVITY(V)
2
P.CON EXT.AMP.CONT.
B.M.S.
$
%
80
GND
FREQ(Hz)
3
3
1
1
(REMOTE)
OPEN/ B.M.S.
4
4
R
0.5
0.5
FREQ (Hz)
0.2
(MIN)(MAX)
CLOSE
FREQ (Hz)
R
5
0.2
5
50
100
(MIN)(MAX)
OFF 25Hz
15Hz
HPF LPF
OFF
B.M.S.
(+6)
B.M.S.
HPF LPF
OFF
OFF 25Hz
15Hz
STEREO MONO AB
A
A
B
A
+
B
STEREO MONO
OPERATION
INFRASONIC
FILTER
OPERATION INPUT SELECT
LINE IN
LINE OUT
FILTER
INFRASONIC
*
6 7 8 9
0 !
This is a 4 channel amplifier including 2 stereo amplifiers in a body. One amplifier is referred to
as amplifier A and the other is amplifier B. This unit is compatible with a large variety of
systems by combining the switches and functions described in the following.
#1
#2
@
$
%
&
^
*
FREQ (Hz)
#
INPUT SENSITIVITY(V)
2
A
L
3
1
HPF LPF
OFF
OFF 25Hz
15Hz
STEREO MONO
OPERATION
A
B
4
0.5
0.2
FILTER
INFRASONIC
FREQ (Hz)
R
50
200
50
200
5
(MIN)(MAX)
LO PASS
HI PASS
B.M.S.
80
FREQ(Hz)
AB
A
(REMOTE)
OPEN/ B.M.S.
B
INPUT SENSITIVITY(V)
2
INPUT SELECT
L
CLOSE
3
50
100
1
STEREO MONO
OPERATION
OFF 25Hz
15Hz
HPF LPF
OFF
4
0.5
0.2
(MIN)(MAX)
B.M.S.
(+6)
B.M.S.
INFRASONIC
5
FILTER
50
200
50
200
R
LO PASS
HI PASS
#1 When FILTER is set to LPF, the sound is monaural (L+R).
Block diagram
#2 When INFRASONIC is set to 15Hz or 25Hz, the sound is monaural (L+R).
* Note that if OPERATION is set to MONO, Lch is still monaural.
The speakers to be connected should
1 Fuse (20 A × 4)
2 Battery terminal
3 Ground terminal
have an impedance of 4Ω or greater.
When multiple speakers are to be
connected, ensure that the combined
impedance is 4Ω or greater.
4 Amplifier A speaker output
2CAUTION
terminals
The rated input of the speakers should be
no less than the maximum output of the
amplifier. Otherwise malfunction may
result.
5 Amplifier B speaker output
terminals
❖SPEAKER OUTPUT terminals
• Stereo Connections:
6 RCA cable ground lead terminal
7 Amplifier A LINE IN terminal
8 Amplifier B LINE IN terminal
When you wish to use the unit as a stereo
amplifier, stereo connections are used.
The speakers to be connected should
have an impedance of 2Ω or greater.
When multiple speakers are to be
connected, ensure that the combined
impedance is 2Ω or greater for each
channel.
9 LINE OUT terminal
These jacks output respectively the signals
input to amplifiers A and B. They always
output the stereo signals regardless of the
position of the OPERATION switch.
• Bridged Connections:
When you wish to use the unit as a high-
output monaural amplifier, bridged
connections are used. (Make connections
to the LEFT channel (+) and the RIGHT
channel (-) SPEAKER OUTPUT terminals.)
0 Power control terminal
! EXT.AMP.CONT. (external
amplifier control) terminal
This controls the B.M.S. (See P.6).
4 English
Download from Www.Somanuals.com. All Manuals Search And Download.
&
FILTER
FREQUENCY
CONTROL
B
A
INPUT SENSITIVITY(V)
2
B.M.S.
80
FREQ(Hz)
3
1
(REMOTE)
OPEN/ B.M.S.
COOLING FAN
4
AIR
0.5
FREQ (Hz)
0.2
INDUCTION
50
200
50
200
CLOSE
OPERATION/PROTECTION
5
50
100
LO PASS
HI PASS
(MIN)(MAX)
4
/
3
/
2
CHANNEL POWER AMPLIFIER
OPEN/CLOSE
B
FILTER
FREQUENCY
B.M.S.
(+6)
B.M.S.
HPF LPF
OFF
OFF 25Hz
15Hz
STEREO MONO
OPERATION
LOW VOLTAGE
50
200
50
200
FILTER
INFRASONIC
LO PASS
HI PASS
B
B.M.S.
50
200
50
200
50
200
50
200
LO PASS
HI PASS
LO PASS
HI PASS
^
@ INPUT SELECTOR switch
% FILTER switch
This switch selects the input method of the
This switch allows to apply high-pass or
low-pass filtering to the speaker outputs.
signals to be amplified by amplifiers A and
B.
• A B position:
Amplifies both of the signals input to
amplifiers A and B.
• HPF (High-Pass Filter) position:
The filter outputs the band of higher
frequencies than the frequency set with the
HPF FREQUENCY control.
• A position:
Amplifies only signal input amplifier A with
both amplifiers A and B.
• OFF position:
The entire bandwidth is output without
filtering.
• LPF (Low-Pass Filter) position:
The filter outputs the band of lower
frequencies than the frequency set with the
LPF FREQUENCY control.
The speaker output is automatically turned
monaural (L+R) and the bass boost function
is activated.
# INPUT SENSITIVITY control
Adjust this control according to the pre-out
level of the centre unit connected to this
amplifier.
The sensitivities of amplifiers A and B can
be adjusted independently regardless of the
position of the input selector switch.
^ HPF FREQUENCY control
Sets the cutoff frequency when the FILTER
switch is set to HPF.
NOTE
Refer to “Specifications” on the centre
unit’s instruction manual about the pre-out
level.
& LPF FREQUENCY control
Sets the cutoff frequency when the FILTER
switch is set to LPF.
$ OPERATION switch
The amplification methods of the signals
input to amplifiers A and B can be selected
independently according to the setting of
this switch.
* INFRASONIC FILTER switch
When this switch is set to 15 Hz or 25 Hz,
frequencies below the setting value will be
cut. This serves to get rid of unwanted
vibrations that do not result in sound and
improves the speakers’ ability to reproduce
sound. Note that the speaker output will
automatically be set for monaural (L+R)
sound.
• STEREO position:
The amplifier can be used as a stereo
amplifier.
• MONO (Lch) position:
Amplifies the signal input from the left side
only. Set to this position and make bridged
connections to use as a high-power
monaural amplifier. (The input right signal is
not output.)
English 5
Download from Www.Somanuals.com. All Manuals Search And Download.
B.M.S. (Bass Management System)
2
1
B.M.S.
80
FREQ(Hz)
(REMOTE)
OPEN/ B.M.S.
CLOSE
50
100
B.M.S.
(+6)
COOLING FAN
AIR
INDUCTION
B.M.S.
OPERATION/PROTECTION
4
/
3
/
2
CHANNEL POWER AMPLIFIER
OPEN/CLOSE
FILTER
FREQUENCY
A
LOW VOLTAGE
OPERATION/PROTECTION
50
200
50
200
LO PASS
HI PASS
B
B.M.S.
50
200
50
200
3
LO PASS
HI PASS
OPEN/CLOSE
LOW VOLTAGE
B.M.S. indicator
B.M.S.
■ If the unit is not going to be operated from the outside:
1 B.M.S. switch
NOTE
This boosts the bass, focusing mainly on
the frequency setting determined using the
B.M.S. FREQUENCY control.
The bass boost applies only to the B
amplifier.
• (REMOTE) OPEN/CLOSE or
(REMOTE) B.M.S. position:
When the switch is in this position, the
bass is not boosted.
• If the slide panel meets an obstacle whilst
sliding, the slide operation will be halted. If
this happens, remove the obstacle and then
press the OPEN/CLOSE button again.
• If the centre unit power is switched OFF, or
the vehicle engine is switched OFF, whilst
the slide panel is open, the slide panel will
then close automatically. The next time the
power is turned ON or the vehicle engine is
turned ON, the slide panel will return to its
original open state.
Bass boost
Flat (OFF)
Operations using the
OPEN/CLOSE button
Slide panel
• If the B.M.S. switch setting is changed to
(REMOTE), the slide panel will close in
preparation for remote operation, even if the
EXT.AMP.CONT. terminal is not connected.
• B.M.S. (+6) position:
When the switch is in this position, the
bass is boosted by 6dB.
2CAUTION
The B.M.S. indicator glows.
Take care not to allow your finger or any other
object to be trapped by the slide panel whilst
it is sliding.
Bass boost
+6dB (ON)
Operations using the
OPEN/CLOSE button
Slide panel
2 B.M.S. FREQUENCY control
When the B.M.S. switch is set to the
B.M.S. (+6) position, this control can be
used to adjust the central frequency that
you want to emphasise.
3 OPEN/CLOSE button
Each time you press this button, the slide
panel either opens or closes.
6 English
Download from Www.Somanuals.com. All Manuals Search And Download.
■ If the unit is going to be operated from the centre unit:
The amount of bass boost and the opening/closing of the slide panel can be controlled from
the centre unit. Additionally, up to 3 power amplifiers can be set at the same time.
NOTE
Kenwood centre units released in 1999 or later having an “EXT.AMP.CONT.” cable operate
this unit. Instructions on how to operate the centre unit will be found in the instruction manual
supplied with the centre unit.
1 B.M.S. switch
2 B.M.S. FREQUENCY control
This control allows you to use the B.M.S. to
adjust the central frequency that you want
to emphasise.
This switch is used to select the range of
control operations that can be carried out
from the centre unit.
The bass boost only applies to the B
amplifier.
When the bass boost is switched ON, the
B.M.S. indicator glows.
• (REMOTE) OPEN/CLOSE position:
When the switch is in this position, only the
opening/closing of the slide panel can be
controlled from the centre unit; the bass
cannot be boosted.
3 OPEN/CLOSE button
• When the B.M.S. switch is in the B.M.S.
(+6) position, the slide panel will open or
close each time the button is pressed.
• When the B.M.S. switch is set to the
(REMOTE) position, the centre unit will
control the slide panel.
If you want to adjust the control inside the
slide panel, you can open/close the slide
panel temporarily by pressing the
OPEN/CLOSE button.
AMP
BASS
Flat
AMP
BASS
+6
AMP
BASS
+12
Centre unit
setting status
NOTE
Bass boost
Slide panel
Flat (OFF)
• If the slide panel meets an obstacle whilst
sliding, the slide operation will be halted. If
this happens, remove the obstacle and then
press the OPEN/CLOSE button again.
• When the B.M.S. is in the (REMOTE)
position, and control operations are carried
out on the centre unit, the slide panel will
return to the status set on the centre unit
even if it is opened/closed using the
OPEN/CLOSE button.
• If the centre unit power is switched OFF, or
the vehicle engine is turned OFF, when the
slide panel is open, the slide panel will
automatically close.
When the power is turned back ON, or
when the vehicle engine is turned ON, the
slide panel will carry out an action
depending on the setting status of the
B.M.S. switch, as follows.
*If the B.M.S. switch is in the (REMOTE)
position, the slide panel will obey the
setting on the centre unit.
CLOSE
OPEN
• (REMOTE) B.M.S. position:
When the switch is in this position, any of
the three bass boost settings — FLAT,
+6dB and +12dB — can be selected from
the centre unit. If "+6 dB" or "+12 dB" is
selected, the slide panel will open.
AMP
BASS
Flat
AMP
BASS
+6
AMP
BASS
+12
+12dB
(ON)
Centre unit
setting status
Flat
+6dB
(ON)
Bass boost
Slide panel
(OFF)
CLOSE
OPEN
• B.M.S. (+6) position:
When the switch is in this position, the
bass is boosted by 6dB, regardless of any
operation carried out from the centre unit.
AMP
BASS
Flat
AMP
BASS
+6
AMP
BASS
+12
Centre unit
setting status
*If the B.M.S. switch is in the B.M.S. (+6)
position, the slide panel will return to its
original open state.
Bass boost
Slide panel
+6dB (ON)
Operations using the
OPEN/CLOSE button
2CAUTION
Take care not to allow your finger or any other
object to be trapped by the slide panel whilst
it is sliding.
English 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Indicator
1
2
COOLING FAN
COOLING FAN
3
OPERATION/PROTECTION
OPERATION/PROTECTION
POWER
4
/
3
/
2
CHANNEL POWER AMPLIFIER
OPEN/CLOSE
LOW VOLTAGE
I
OPEN/CLOSE
B.M.S.
4
5
LOW VOLTAGE
B.M.S.
■ PROTECTION function
1 POWER indicator
This unit incorporates a protection function
which protects the main unit and speakers
from troubles. The unit stops to function
when the protection function is activated.
This indicator glows when the unit's power
is turned ON.
2 COOLING FAN indicator
When the unit's internal temperature rises,
the side fan is activated. If the internal
temperature rises even further, the slide
panel opens automatically, and the cooling
fan on the top is activated.
• When the
OPERATION/PROTECTION indicator
blinks:
• A speaker cable may be short-circuited.
• A speaker output may be in contact with
the ground.
Whilst the top cooling fan is in operation,
the COOLING FAN indicator blinks.
• The temperature of the internal parts may
be higher than 120°C (248°F)
• The fuse of this unit may be blown.
• The unit may be malfunctioning and
sending DC signal to the speaker output.
3 OPERATION/PROTECTION
indicator
This indicator glows when the power
comes ON normally.
If the PROTECTION function is activated,
the indicator blinks or goes out.
• When the POWER indicator and the
OPERATION/PROTECTION function
both go out:
4 LOW VOLTAGE indicator
This indicator glows when the power
voltage falls below 11V (volts).
• The fuse of this unit may be blown.
• When the LOW VOLTAGE indicator
If the power supply voltage returns to full
after a voltage drop, this indicator will blink
to alert the user that a voltage drop has
occurred.
The number of blinks indicates the number
of times the voltage has dropped (up to a
maximum of 10).
glows or blinks:
• Is the battery exhausted?
• The car battery has a small capacity.
• If the battery cable is too thin or too long,
it will not be able to supply enough
power.
• Is the battery cable deteriorated?
5 B.M.S. indicator
This indicator glows when the bass boost is
turned ON using the B.M.S. (See P.6).
NOTE
If indicators 2 to 5 light up in succession or
blink in unison, the system is in DEMO mode.
If this happens, cancel DEMO mode by
pressing the OPEN/CLOSE button.
8 English
Download from Www.Somanuals.com. All Manuals Search And Download.
Connection
■ Power cable connection
2WARNING
To prevent fire caused by a short in the wiring, connect a fusible link or breaker nearby the battery’s
positive terminal.
Wiring
• If a buzzing noise is heard from the speakers when the engine is running, connect a line noise filter
(optional) to each of the battery cable.
• Do not allow the cable to directly contact the edge of the iron plate by using Grommets.
• Connect the ground cable to a metal part of the car chassis that acts as an electrical ground
passing electricity to the battery‘s negative - terminal. Do not turn the power on if the ground
cable is not connected.
• Please be sure to install a protective fuse in the power cable, near the battery. Use a fuse which
has a capacity about 10A higher than the capacity of the fuse in the unit.
• For the power cable and the earth cable, use (flame-resistant) power wiring cables for in-car use.
For the power cable, use a power wiring cable with a current capacity about 10A higher than the
capacity of the protective fuse (about 20A higher than the capacity of the fuse in the unit).
• When more than one power amplifier are going to be used, use a power supply wiring cable and
protective fuse of greater current-handling capacity than the total maximum current drawn by each
amplifier.
Example: One Power Amplifier Is Used
Fuse capacity
Protective Fuse
Cross-sectional Area of Wiring
Cable (AWG)
10 mm (AWG 8) or greater × 1
2
90 A × 1 [30 A × 3]
80 A
30 A
30 A
30 A
90 A
30 A 30 A 30 A
SPEAKER OUTPUT
A
LEFT
BRIDGED
RIGHT
B
FUSE(20A×4)
A
B
BATT.
GND
Lead terminal *
Terminal cover
Power terminal
Battery cable *
Ground cable *
Lead terminal *
Protective
Fuse
Battery
* : Commercially available parts
Power terminal
Pass battery and ground cables through supplied terminal cover and connect to respective
terminals. After completing connections, fasten terminal cover over terminal bracket.
English 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Connection
■ RCA cable connection
B Left input
A Left input
D
N
G
MON
CONTROL
CONTROL
A
B
L
L
INPUT SENSITIVITY(V)
2
INPUT SENSITIVITY(V)
2
P.CON EXT.AMP.CONT.
B.M.S.
80
GND
FREQ(Hz)
3
3
1
1
(REMOTE)
OPEN/ B.M.S.
4
4
R
0.5
0.5
FREQ (Hz)
0.2
(MIN)(MAX)
CLOSE
FREQ (Hz)
R
5
0.2
5
50
100
(MIN)(MAX)
OFF 25Hz
15Hz
HPF LPF
OFF
B.M.S.
(+6)
B.M.S.
HPF LPF
OFF
OFF 25Hz
15Hz
STEREO MONO AB
B
A
+
B
STEREO MONO
OPERATION
INFRASONIC
FILTER
OPERATION INPUT SELECT
LINE N
NE OUT
FILTER
INFRASONIC
RCA cable ground terminal
B Right input
A Right input
Power control cable
RCA cable *
(To Power control terminal)
Front output
Rear output
CENTRE UNIT
(Cassette receiver,
CD receiver, etc.)
* : Commercially available parts
RCA cable ground terminal
When using an RCA cable with a ground lead attached, connect the ground lead to this
terminal.
2CAUTION
Do not use this terminal for power source grounding. This unit will be damaged if the power
source grounding cable is connected to this terminal.
■ Speaker Selection
• The rated input power of the speakers that are going to be connected should be greater than
the maximum output power (in Watts) of the amplifier. Use of speakers having input power
ratings that are less than the output power of the amplifier will cause smoke to be emitted as
well as damage.
• The impedance of the speakers that are going to be connected should be 2Ω or greater (for
stereo connections), or 4Ω or greater (for bridged connections). When more than one set of
speakers are going to be used, calculate the combined impedance of the speakers and then
connect suitable speakers to the amplifier.
Examples:
Stereo Connections (4Ω)
Bridged Connections (4Ω)
200 W or greater
600 W or greater
200W
(2Ω)
100W
(8Ω)
100W
(8Ω)
200W
200W
200W
(4Ω)
200W
(4Ω)
(4Ω)
(4Ω)
200W
(2Ω)
4 Ω
4 Ω
4 Ω
Maximum output of
the amplifier
Combined
impedance
Rated input power and
impedance of the speakers
10 English
Download from Www.Somanuals.com. All Manuals Search And Download.
■ Speakers cable connection
(Stereo Connections)
Front Left speaker
Front Right speaker
Lead terminal *
A Right output
A Left output
SPEAKER OUTPUT
A
LEFT
BRIGED
RIGHT
FUSE(20A×4)
A
B
BATT.
GND
Speaker output terminals
BRIDGED
B Right output
B Left output
A
B
L
R
Rear Right speaker
Rear Left speaker
(Bridged Connections)
Speaker (Bridged)
Lead terminal *
A Bridged output
SPEAKER OUTPUT
A
LEFT
BRIDGED
RIGHT
B
FUSE(20A×4)
A
BATT.
GND
B
Speaker output terminals
BRIDGED
B Bridged output
A
B
L
R
Speaker (Bridged)
* : Commercially available parts
English 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Connection
■ Control terminal
Attach the connection terminal to a commercially available wiring cable for in-car use, and
connect it to the unit.
NOTE
An EXT.AMP.CONT. terminal can only be attached if Kenwood centre unit is a model released in
1999 or latter, and has an “EXT.AMP.CONT.” cable. Using the external amp control, up to 3
power amplifiers can be operated simultaneously (although this may not be possible, depending
on the type of wiring cable used, and its length).
Power control lead terminal
External amplifier control terminal
MONO
CONTROL
CONTROL
A
B
L
L
INPUT SENSITIVITY(V)
2
INPUT SENSITIVITY(V)
2
P.CON EXT.AM.CONT.
B.M.S.
80
GND
FREQ(Hz)
3
3
1
1
(REMOTE)
OPEN/ B.M.S.
4
4
R
0.5
0.5
FREQ (Hz)
0.2
(MIN)(MAX)
CLOSE
FREQ (Hz)
R
5
0.2
5
50
100
(MIN)(MAX)
OFF 25Hz
15Hz
HPF LPF
OFF
B.M.S.
(+6)
B.M.S.
HPF LPF
OFF
OFF 25Hz
15Hz
STEREO MONO AB
A
A
B
A
+
B
STEREO MONO
OPEATION
INFRASONIC
FILTER
OPERATION INPUT SELECT
LINE IN
LINE OUT
FILTER
INFRASONIC
.
T
N
O
C
.
Power control cable
(Blue/ White)
P
M
A
.
T
X
E
N
O
C
.
P
CENTRE UNIT
(Cassette receiver,
CD receiver, etc.)
P.CONT.
EXT.AMP.
CONT.
Lead terminal *
Extension cable *
External amplifier control
cable (Pink / Black)
* : Commercially available parts
System examples
■ Full-range 4-channel + Subwoofer system
FILTER
FREQUENCY
HPF LPF
OFF
L
STEREO MONO
OPERATION
L
Front
A
A
FILTER
R
INPUT SENSITIVITY(V)
2
3
speaker
FREQ (Hz)
R
CENTRE UNIT
Switch setting
CONTROL
A
1
50
200
50
200
LO PASS
HI PASS
4
OFF 25Hz
15Hz
L
0.5
0.2
5
INFRASONIC
(MIN)(MAX)
B
L
R
Rear
speaker
AB
A
HPF LPF
OFF
R
INPUT SELECT
B.M.S.
80
L
STEREO MONO
OPERATION
LINE
OUT
FREQ(Hz)
(REMOTE)
B
FILTER
R
INPUT SENSITIVITY(V)
2
3
OPEN/ B.M.S.
CLOSE
FREQ (Hz)
50
100
1
L
CONTROL
50
200
50
200
B
4
OFF 25Hz
15Hz
LO PASS
HI PASS
B.M.S.
(+6)
B.M.S.
0.5
0.2
Subwoofer
(High pass)
5
R
INFRASONIC
(MIN)(MAX)
Amplifier
■ High-pass + Subwoofer system
FILTER
FREQUENCY
HPF LPF
OFF
STEREO MONO
OPERATION
L
A
L
FILTER
A
B
INPUT SENSITIVITY(V)
2
R
FREQ (Hz)
CENTRE UNIT
Switch setting
3
R
CONTROL
A
1
50
200
50
200
LO PASS
HI PASS
4
OFF 25Hz
15Hz
0.5
0.2
L
5
INFRASONIC
(MIN)(MAX)
R
Subwoofer
(L + R)
(Bridged)
AB
A
HPF LPF
OFF
B.M.S.
80
INPUT SELECT
STEREO MONO
OPERATION
FREQ(Hz)
L
B
LINE
OUT
FILTER
(REMOTE)
OPEN/ B.M.S.
INPUT SENSITIVITY(V)
2
R
CLOSE
FREQ (Hz)
50
100
3
1
CONTROL
50
200
50
200
B
4
B.M.S.
(+6)
B.M.S.
OFF 25Hz
15Hz
LO PASS
HI PASS
0.5
0.2
5
INFRASONIC
(MIN)(MAX)
12 English
Download from Www.Somanuals.com. All Manuals Search And Download.
System examples
■ High-power 2-channel system
FILTER
FREQUENCY
HPF LPF
OFF
STEREO MONO
OPERATION
Left
A
L
L
FILTER
A
B
INPUT SENSITIVITY(V)
2
speaker
R
FREQ (Hz)
CENTRE UNIT
Switch setting
3
CONTROL
A
1
50
200
50
200
LO PASS
HI PASS
4
OFF 25Hz
15Hz
0.5
0.2
R
L
5
INFRASONIC
(MIN)(MAX)
Right
speaker
R
AB
A
HPF LPF
OFF
B.M.S.
80
INPUT SELECT
STEREO MONO
OPERATION
FREQ(Hz)
L
B
LINE
OUT
FILTER
(REMOTE)
OPEN/ B.M.S.
INPUT SENSITIVITY(V)
2
R
CLOSE
FREQ (Hz)
50
100
3
1
CONTROL
50
200
50
200
B
4
B.M.S.
(+6)
B.M.S.
OFF 25Hz
15Hz
LO PASS
HI PASS
0.5
0.2
5
INFRASONIC
(MIN)(MAX)
■ Tri-mode
C
C
L
L
FILTER
FREQUENCY
HPF LPF
OFF
STEREO MONO
OPERATION
L
L
A
FILTER
A
B
R
INPUT SENSITIVITY(V)
2
3
FREQ (Hz)
R
CENTRE UNIT
Switch setting
CONTROL
A
1
50
200
50
200
LO PASS
HI PASS
4
OFF 25Hz
15Hz
0.5
0.2
L
5
INFRASONIC
(MIN)(MAX)
R
L
AB
A
HPF LPF
OFF
B.M.S.
80
INPUT SELECT
STEREO MONO
OPERATION
L
FREQ(Hz)
LINE
OUT
B
FILTER
R
(REMOTE)
OPEN/ B.M.S.
R
INPUT SENSITIVITY(V)
2
3
CLOSE
FREQ (Hz)
50
100
1
CONTROL
50
200
50
200
B
4
B.M.S.
(+6)
B.M.S.
OFF 25Hz
15Hz
LO PASS
HI PASS
0.5
0.2
Subwoofer
(L + R) (Bridged)
(High pass)
5
INFRASONIC
(MIN)(MAX)
●Principle of Tri-mode
Method of frequency band division using a coil and capacitor•••in case of 6dB/oct. slope
Coil (L): Passes low frequencies and blocks high
Crossover Frequency
frequencies. (Low pass)
0 dB
-3 dB
Capacitor (C): Passes high frequencies and blocks low
frequencies. (High pass)
L
C
159000
C=
L=
(µF)
fc x R
159 x R
fc
fc=Cut of Frequency (Hz)
R=Speaker Impedance (Ω)
Frequency
(mH)
●Example:
When it is required to set a crossover frequency of 120 Hz using speakers with an
impedance of 4 ohms.
Prepare commercially-available coil and capacitor with the closest ratings to the results
calculated from the formula above. The capacitor rating should be as close as possible to 331.25
(µF) and the coil rating should be as close as possible to 5.3 (mH).
2CAUTION
• If you wish to bridge-connect a speaker, the speaker impedance must be no less than 4 ohms.
Connecting a speaker with an impedance lower than 4 ohms may damage the unit.
• Be sure to connect capacitors to speakers to which high frequencies will be passed. Failure to
do so will result in a drop of the combined impedance with the subwoofer.
• Ensure that the withstand voltage and current ratings of the capacitors (C) and coils (L) are
sufficient.
English 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting Guide
What might appear to be a malfunction in your unit may just be the result of slight
misoperation or miswiring. Before calling service, first check the following table for possible
problems.
PROBLEM
POSSIBLE CAUSE
SOLUTION
No sound.
(No sound from one side.)
• Input (or output) cables are
disconnected.
• Connect the input (or output)
cables.
• Protection circuit may be
activated.
• Check connections by referring
to "Indicator".
• The fuse may be blown because • Replace the fuse with a new
the volume was too high.
fuse and use a lower volume.
The output level is too
small (or too large).
The input sensitivity adjusting
control is not set to the correct
position.
Adjust the control correctly
referring to “Controls”.
The sound quality is bad.
(The sound is distorted.)
• The speakers cable are
connected with wrong + / -
polarity.
• Connect them properly checking
the + / - of the terminals and
cables well.
• A speaker cable is pinched by a • Connect the speaker cable again
screw in the car body.
so that it is not pinched by
anything.
• The switches may be set
improperly.
• Set switches properly by
referring to "System examples".
If the slide panel moves of • The system is in DEMO mode.
its own accord.
• Cancel DEMO mode by pressing
the OPEN/CLOSE button.
• Check the B.M.S. and operate
the slide panel remotely or
manually.
• The slide panel has gone into
remote operation mode.
The external amplifier
controller (B.M.S.) will not
work.
• The B.M.S. switch is set to
"B.M.S. (+6)".
• The external amplifier control
cable has come loose.
• The B.M.S. switch is set to
"(REMOTE)".
• Check that the external amplifier
control cable is properly
connected.
14 English
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Specifications subject to change without notice.
Audio Section
Max Power Output (4 Ω)
4 Channel Mode ........................................................................................................150 W × 4
3 Channel Mode....................................................................................150 W × 2 + 600 W × 1
2 Channel Mode ........................................................................................................600 W × 2
Rated Power Output (4 Ω) (+B = 12.0 V)
4 Channel Mode ........................................................50 W × 4 (20 Hz ~ 20 kHz, 0.05 % THD)
3 Channel Mode....................50 W × 2 (1 kHz, 0.05 % THD) + 200 W × 1 (1 kHz, 0.5 % THD)
2 Channel Mode ........................................................................200 W × 2 (1 kHz, 0.5 % THD)
Rated Power Output (2 Ω) (+B = 12.0 V)
4 Channel Mode ........................................................................100 W × 4 (1 kHz, 0.5 % THD)
Rated Power Output (4 Ω) (+B = 14.4 V)
4 Channel Mode....................................................................75 W × 4 (DIN45324, +B=14.4 V)
3 Channel Mode....................75 W × 2 (1 kHz, 0.05 % THD) + 300 W × 1 (1 kHz, 0.5 % THD)
2 Channel Mode ........................................................................300 W × 2 (1 kHz, 0.5 % THD)
Rated Power Output (2 Ω) (+B = 14.4 V)
4 Channel Mode ........................................................................150 W × 4 (1 kHz, 0.5 % THD)
Frequency Response (+0, –3 dB)..............................................................................5 Hz ~ 50 kHz
#
Total Harmonic Distortion (Rated power) ................................................................0.01 % (1 kHz)
Signal to Noise Ratio............................................................................................................110 dB
Sensitivity (rated output) (MAX) ..............................................................................................0.2 V
Sensitivity (rated output) (MIN) ..............................................................................................5.0 V
Input Impedance....................................................................................................................10 kΩ
Damping Factor........................................................................................................More than 200
Low Pass Filter Frequency (24 dB/oct.)........................................................50 ~ 200 Hz (Variable)
High Pass Filter Frequency (12 dB/oct.) ......................................................50 ~ 200 Hz (Variable)
Infrasonic Filter Frequency (24 dB/oct.) ..........................................................................15 / 25 Hz
# Sensitivity = Mini. , Through LPF (30 kHz)
General
Operating Voltage ..............................................................................12.0 V (11 ~ 16 V allowable)
Current Consumption (4 Ω, +B = 12.0 V, 10% THD) ..............................................................42 A
Dimensions (W × H × D) ..................................................................................272 × 64 × 380 mm
Weight ..................................................................................................................................7.1 kg
English 15
Download from Www.Somanuals.com. All Manuals Search And Download.
|