		 ACCESSORY KIT INSTALLATION MANUAL   
					ELECTRIC HEATER ACCESSORY – ECL SERIES   
					FOR USE WITH MODELS: AHX61D4PH21 AND AHX61D4P121   
					GENERAL INFORMATION   
					INSTALLATION   
					1. Refer to Table 1 for appropriate kit.   
					2. Check kit for physical damage, do not install damaged kit.   
					3. Remove the upper access panel from air handler.   
					ELECTRICAL SHOCK HAZARD   
					4. Unplug the Mate-n-Lock connector (Refer to Figure 3) and   
					Remove block-off plate or existing heater kit from air han-   
					dler by removing 6 screws. See Figure. 2.   
					Installation or repairs made by unqualified persons can result   
					in hazards to you and others. Installation must conform with   
					local building codes or, in the absence of local codes, with   
					National Electrical Code ANSI/NFPA 70-current edition and   
					Fire Codes, NFPA 90A and 90B.   
					5. Slide the heater kit into the slot and secure element plate to   
					divider deck with the 6 previously removed screws.   
					The information contained in this manual is intended for use   
					by a qualified service technician familiar with safety proce-   
					dures and equipped with the proper tools and test instru-   
					ments.   
					Shut OFF electric power at unit disconnect and/or service   
					panel before beginning the following procedures.   
					Failure to carefully read and follow all instructions in this man-   
					ual can result in malfunction, property damage, personal   
					injury, and/or death.   
					6. Insert power leads into the circuit breaker lugs or terminal   
					block and tighten. See Figure. 3.   
					7. Connect ground wire to ground lug. See Figure. 3.   
					8. Plug in the Mate-N-Lock connector.   
					9. Break out appropriate number of circuit breaker openings   
					on the access panel of the air handler.   
					10. Mark an X in the appropriate box on the indoor unit data   
					plate for the particular heater installed.   
					Verify edges of foil faced insulation are not in contact with any   
					exposed electrical connections.   
					A means of strain relief and conductor protection must be pro-   
					vided at the supply wire entrance into cabinet.   
					Use copper conductors only.   
					This instruction covers the physical installation of the following   
					electric heaters with AHX61 single piece air handlers. These   
					electric heat accessories are used for applications of cooling   
					with electric heat and heat pump with electric heat. Refer to unit   
					instructions for electrical specifications.   
					TABLE 1: Kits Available   
					FIGURE 2:   
					Kit Part #   
					S1-ECL05   
					S1-ECL10   
					S1-ECL15   
					Description   
					5KW Heat Strip w/ Circuit Breaker   
					10KW Heat Strip w/ Circuit Breaker   
					15KW Heat Strip w/ Circuit Breaker   
					S1-ECL20   
					S1-ECL25   
					S1-ECL30   
					20KW Heat Strip w/ Circuit Breaker   
					25KW Heat Strip w/ Circuit Breaker   
					30KW Heat Strip w/ Circuit Breaker   
					FIGURE 3:   
					FIGURE 1:   
					Subject to change without notice. Published in U.S.A.   
					Copyright © 2010 by Johnson Controls, Inc. All rights reserved.   