Intel® Blade Server Switch Module
SBCEFCSW Management and User’s
Guide
A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies & Products
Order Number C39671-003
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Handling electrostatic discharge-sensitive devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Regulatory specifications and disclaimers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Safety compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Electromagnetic compatibility notice (USA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Electromagnetic compatibility notices (International) . . . . . . . . . . . . . . . . . . . . . . . . . xii
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Notices used in this book. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Command line interface (CLI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Command syntax. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Config command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Fallback command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Passwd command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Set Log command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Set Port command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Show command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Show Config command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Show Perf command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Test command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Whoami command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Zoneset command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Zoning command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
3 Using the SAN Utility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Menu bar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Data window and tabs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Using the Topology window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Working with switch modules and links. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Topology data window tabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Using the Faceplate window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Opening the Faceplate window and pop-up menus . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Port views and status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Managing the fabric database. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Removing a fabric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Fabric status. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Active Zoneset Data window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Zoning a fabric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Zoning concepts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Using the Edit Zoning window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Creating a zone set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
Copying a zone to a zone set. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
iv
Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing a zone from all zone sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Managing aliases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Creating an alias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Removing an alias from all zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Fabric view port graphing application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Port Information Data window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Configured Zonesets Data window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Configuring alarms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
Exporting name server information to a file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Paging a switch module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Setting the date and time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Resetting a switch module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Configuring a switch module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Domain ID and Domain ID Lock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
Timeout values. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
IP configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Remote logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
Port graphing and Fabric View application. . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Port Information data window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Changing port administrative states. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Changing port speeds (external ports only) . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Contents
v
Download from Www.Somanuals.com. All Manuals Search And Download.
I/O stream guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Extending port credits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
4 Switch management utility functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
LED diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Heartbeat LED patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Internal firmware failure LED flash pattern. . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Switch module fault LED flash pattern . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Port testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
SNMP configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
SNMP trap configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Configuration backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
Reinitializing the configuration file system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Arranging and sizing port performance graphs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
A Mapping port locations and software numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
B Getting help and technical assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
C Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
vi
Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety and regulatory information
✏ NOTE
The service procedures are designed to help you isolate problems. They are written with the
assumption that you have model-specific training on all computers, or that you are familiar with the
computers, functions, terminology, and service information provided in this manual.
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
General Safety
Follow these rules to ensure general safety:
•
•
•
Observe good housekeeping in the area of the machines during and after maintenance.
Do not perform any action that causes hazards to the customer, or that makes the equipment unsafe.
Place removed covers and other parts in a safe place, away from all personnel, while you are servicing the
machine.
•
•
Keep your tool case away from walk areas so that other people will not trip over it.
Do not wear loose clothing that can be trapped in the moving parts of a machine. Ensure that your sleeves
are fastened or rolled up above your elbows. If your hair is long, fasten it.
•
•
•
•
•
Insert the ends of your necktie or scarf inside clothing or fasten it with a nonconductive clip,
approximately 8 centimeters (3 inches) from the end.
Do not wear jewelry, chains, metal-frame eyeglasses, or metal fasteners for your clothing. Remember:
Metal objects are good electrical conductors.
Wear safety glasses when you are: hammering, drilling soldering, cutting wire, attaching springs, using
solvents, or working in any other conditions that might be hazardous to your eyes.
After service, reinstall all safety shields, guards, labels, and ground wires. Replace any safety device that
is worn or defective.
Reinstall all covers correctly before returning the machine to the customer.
Electrical Safety
CAUTION:
Electrical current from power, telephone, and communication cables can be hazardous. To
avoid personal injury or equipment damage, disconnect the server system power cords,
telecommunication systems, networks, and modems before you open the server covers.
Important: Observe the following rules when working on electrical equipment:
•
•
Disconnect all power before performing a mechanical inspection.
Before you start to work on the machine, unplug the power cord. or power-off the wall box that supplies
power to the machine and to lock the wall box in the off position.
•
•
•
•
Regularly inspect and maintain your electrical hand tools for safe operational condition.
Do not use worn or broken tools and testers.
Never assume that power has been disconnected from a circuit. First, check that it has been powered-off.
Always look carefully for possible hazards in your work area. Examples of these hazards are moist floors,
nongrounded power extension cables, power surges, and missing safety grounds.
•
Do not touch live electrical circuits with the reflective surface of an inspection mirror. The surface is
conductive; such touching can cause personal injury and machine damage.
viii Intel Blade Server Switch Module SBCEFCSW Module Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Handling electrostatic discharge-sensitive devices
Any computer part containing transistors or integrated circuits (IC) should be considered sensitive to
electrostatic discharge (ESD). ESD damage can occur when there is a difference in charge between objects.
Protect against ESD damage by equalizing the charge so that the server, the part, the work mat, and the person
handling the part are all at the same charge.
✏ NOTE
Use product-specific ESD procedures when they exceed the requirements noted here.
Make sure that the ESD-protective devices you use have been certified (ISO 9000) as fully effective.
When handling ESD-sensitive parts:
•
•
•
•
Keep the parts in protective packages until they are inserted into the product.
Avoid contact with other people.
Wear a grounded wrist strap against your skin to eliminate static on your body.
Prevent the part from touching your clothing. Most clothing is insulative and retains a charge even when
you are wearing a wrist strap.
•
•
Use the black side of a grounded work mat to provide a static-free work surface. The mat is especially
useful when handling ESD-sensitive devices.
Select a grounding system, such as those in the following list, to provide protection that meets the specific
service requirement.
— Attach the ESD ground clip to any frame ground, ground braid, or green-wire ground.
— Use an ESD common ground or reference point when working on a double-insulated or battery-
operated system. You can use coax or connector-outside shells on these systems.
— Use the round ground-prong of the AC plug on AC-operated computers.
✏ NOTE
The use of a grounding system is desirable but not required to protect against ESD damage.
CAUTION:
If your system has a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can explode if not
properly used, handled, or disposed of. Do not:
•
•
•
•
Throw or immerse into water
Heat to more than 100×C (212×F)
Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
CAUTION:
When laser products (such as CD-ROMs, DVD-ROM drives, fiber optic devices, or
transmitters) are installed, note the following:
•
•
Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous
laser radiation. There are no serviceable parts inside the device.
Use of controls or adjustments or performance of procedures other than those specified herein might
result in hazardous radiation exposure.
ix
Download from Www.Somanuals.com. All Manuals Search And Download.
Danger: DANGER
Danger: Some laser products contain an embedded Class 3A or Class 3B laser diode. Note the
following:
Danger: Laser radiation when open. Do not stare into the beam, do not view directly with optical
instruments, and avoid direct exposure to the beam.
CAUTION:
Hazardous energy is present when the blade is connected to the power source. Always replace
the blade cover before installing the blade.
Regulatory specifications and disclaimers
Safety compliance
USA:
UL 60950 - 3rd Edition/CSA 22.2. No. 60950
Canada:
cUL certified - 3rd Edition/CSA 22.2. No. 60950- for Canada (product bears the single
cUL mark for U.S. and Canada)
Europe:
Low Voltage Directive, 73/23/EEC
UL/CB to EN60950 3rd Edition
UL/CB to IEC 60950 3rd Edition
International:
UL/CB - EN60 950 3rd Edition
UL/CB - EMKO-TSE (74-SEC) 207/94
Australia/New
Zealand:
CB Report to IEC 60950, 3rd Edition plus international deviations
x
Intel Blade Server Switch Module SBCEFCSW Module Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Electromagnetic compatibility (EMC)
USA:
FCC CFR 47 Part 2 and 15, Verified Class A Limit
Canada:
Europe:
IC ICES-003 Class A Limit
EMC Directive, 89/336/EEC
EN55022, Class A Limit, Radiated & Conducted Emissions
EN55024 ITE Specific Immunity Standard
EN61000-4-2 ESD Immunity (Level 2 Contact Discharge, Level 3 Air Discharge)
EN61000-4-3 Radiated Immunity (Level 2)
EN61000-4-4 Electrical Fast Transient (Level 2)
EN61000-4-5 AC Surge
EN61000-4-6 Conducted RF
EN61000-4-8 Power Frequency Magnetic Fields
EN61000-4-11 Voltage Dips and Interrupts
VCCI Class A ITE (CISPR 22, Class A Limit)
AS/NZS 3548, Class A Limit
Japan:
Australia/New
Zealand:
Taiwan:
BSMI Approval
Korea:
RRL Approval
Russia:
GOST Approval
CISPR 22, Class A Limit
International:
Electromagnetic compatibility notice (USA)
This equipment has been tested and found to comply with the limits for a Class A digital device, puruant to
Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference at
his own expense.
xi
Download from Www.Somanuals.com. All Manuals Search And Download.
Electromagnetic compatibility notices (International)
Europe (CE Declaration of Conformity): This product has been tested in accordance to, and complies with
the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with
the CE Mark to illustrate its compliance.
Japan EMC Compatibility:
English translation of the notice above: This is a Class A product based on the standard of the Voluntary
Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a
domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to
take corrective actions.
ICES-003 (Canada): Cet appareil numérique respecte les limites bruits radioélectriques applicables aux
appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: "Appareils Numériques",
NBM-003 édictée par le Ministre Canadian des Communications.
English translation of the notice above: This digital apparatus does not exceed the Class A limits for radio
noise emissions from digital apparatus set out in the interference-causing equipment standard entitled "Digital
Apparatus", ICES-003 of the Canadian Department of Communications.
BSMI (Taiwan): The BSMI Certification number and the following warning is located on the product safety
label which is located visibly on the external chassis.
RRL Korea:
xii Intel Blade Server Switch Module SBCEFCSW Module Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
English translation of the previous notice:
Device
User’s Information
Class A device
This device complies with RRL EMC and is operated
in commercial environment so that distributors or
users pay attention to this point.
If the product is sold or purchased improperly, please
exchange this product to what can be used at home.
Class B device
This device complies with RRL EMC and is operated
in a residential area so that it can be used at all other
location as well as residential area.
Remarks: Class A device - operated in a commercial area. Class B device - operated in a residential area.
xiii
Download from Www.Somanuals.com. All Manuals Search And Download.
xiv Intel Blade Server Switch Module SBCEFCSW Module Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
1 Introduction
You can manage and configure your Intel® Blade Server Switch Module SBCEFCSW through a Telnet
connection to the embedded command line interface (CLI) or by using the SAN Utility application. The SAN
Utility provides an intuitive graphical user interface (GUI) that you can use to configure multiple Fibre
Channel switch modules through other connected SAN devices from a single interface. The SAN Utility
application is referred to throughout this publication as the SAN Utility. The Fibre Channel Switch Module is
referred to throughout this publication as the switch module.
This User’s Guide provides instructions to:
•
•
•
Configure your switch module
Manage fabrics, ports, and switch modules
Use Telnet and the CLI to configure switch module parameters
You can manage the SBXL52 fabric through an Ethernet network using the SAN Utility or the CLI. The SAN
Utility is installed on a Microsoft* Windows* 2003, Advanced Server Version 2.1 and Red Hat* Linux*
Version 9.0.
The switch module has an embedded Telnet server through which a Telnet client can connect and manage the
switch module using the CLI. See Chapter <$elemparanumonlyCommand line interface (CLI),” on page 5 for
more information about Telnet and CLI commands.
SNMP provides monitoring and trap functions for the fabric. The switch module firmware supports SNMP
Versions 1, 2, and 3; the Fibre Alliance Management Information Base (FA-MIB) version 4.0; and the Fabric
Element Management Information Base (FE-MIB) RFC 2837. Traps are formatted using SNMP version 2.
If you are an experienced user, you can use the Telnet CLI to perform the following tasks:
•
•
•
Manage the switch module from the SBCE management module interface to the Telnet client
Perform single switch management
Use advanced control commands
If you are a new user or if you need to manage multiple switch modules from a single interface, you can use
the SAN Utility GUI to perform the following tasks:
•
•
Manage your switch module from a remote client or network management workstation
Manage your multiswitch fabric
For information about installing the switch module and the SAN Utility, see the Intel® Blade Server Switch
Module SBCEFCSW Installation Guide that comes with the switch module.
Related publications
This User’s Guide describes how to use the SAN Utility application. It also describes how to start the Telnet
CLI and lists the CLI commands and their usage. In addition to this User’s Guide, the following related
documentation is provided with your switch module:
•
Intel® Blade Server Switch Module SBCEFCSW Management and User’s Guide
This publication is provided in Portable Document Format (PDF) on the Intel® Blade Server Switch
Module SBCEFCSW Reource CD. It describes how to use the SAN Utility application, describes how to
start the Telnet CLI, and lists the CLI commands and their usage.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
•
Intel® Blade Server Chassis SBFCM Installation and User’s Guide
This publication is provided in Portable Document Format (PDF) on the Resource CD. It contains
information about:
— Installing and configuring the expansion card
— Updating the BIOS and device drivers of the expansion card
•
Intel® Blade Server Compute Switch Module SBCEFCSW and FC Expansion Card SBFCM Hardware
Maintenance Manual and Troubleshooting Guide
This publication is provided in PDF on the Resource CD. It contains information to help you solve
problems yourself, or to provide information to a service technician.
•
QLogic® SAN Solutions Guide
This publication is provided in PDF on the Resource CD. It provides a user-oriented discussion of how
Fibre Channel options are used to provide different SAN storage solutions for various application
requirements. This document also provides an overview and description for backup and restore, business
continuance and high availability, and storage consolidation and data sharing solutions.
•
QLogic® Switch Interoperability Guide
This publication is provided in PDF on the Resource CD. It provides detailed Fibre Channel switch
configuration data and step-by-step configuration procedures for integrating the SBCE unit into other
vendor switch fabrics. Each vendor configuration includes:
— An initial integration checklist
— Configuration limitations
— Supported switch and firmware versions
— Specific management application operations
— A successful-integration checklist.
•
QLogic® SAN Interoperability Guide
This publication is provided in PDF on the Resource CD. It is a key resource for SAN planning and
implementation. It provides interoperability matrices that let you identify at a glance the certified SAN
products, solutions, and services that best suit your needs.
•
•
•
•
QLogic® SAN Configuration Guide: CLARiiON Storage
This publication is provided in PDF on the Resource CD. It is a comprehensive guide for those interested
in deploying QLogic and CLARiion Storage solutions.
QLogic® SAN Configuration Guide: LSI Storage
This publication is provided in PDF on the Resource CD. It is a comprehensive guide for those interested
in deploying QLogic and LSI Storage solutions.
QLogic® SAN Configuration Guide: XIOtech Storage
This publication is provided in PDF on the Resource CD. It is a comprehensive guide for those interested
in deploying QLogic and XIOtech Storage solutions.
Intel® Server Boards and Server Chassis Safety Information
This multilingual publication is provided in PDF on the Resource CD. It contains translated versions of
the caution and danger statements that appear in the documentation.
2
Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Notices used in this book
The following notices are used in this book:
•
•
Notes: These notices provide important tips, guidance, or advice.
Important: These notices provide information or advice that might help you avoid inconvenient or
problem situations.
•
Attention: These notices indicate potential damage to programs, devices, or data. An attention notice is
placed just before the instruction or situation in which damage could occur.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2 Command line interface (CLI)
Your switch module contains an embedded Telnet server. This server enables a Telnet client to establish a
Telnet session with the switch module to retrieve information or to configure parameters using the CLI. You
can use the CLI to perform a variety of fabric and switch management tasks through an Ethernet connection to
your SBCE unit.
You can access the Telnet interface in two ways:
•
•
In the SBCE management module Web interface
In a command-line window on a connected network management workstation
Important: Before you configure your switch module, be sure that the management modules in your SBCE
unit are properly configured. In addition, to access and manage your switch module from an external
environment, you might need to enable certain features, such as the external ports and external management
over all ports. See the applicable Installation and User’s Guide publications on the Resource CD for more
information. For more detailed information about configuring your switch module, see the Intel® Blade Server
Swtich Module SBCEFCSW Installation Guide on the Resource CD.
Logging on to a switch
To log on to a switch using Telnet, complete the following steps:
1. Open a command-line window on the network management workstation, type one of the following
commands, and press Enter.
For switch module bay 3:
telnet 192.168.70.129
For switch module bay 4:
telnet 192.168.70.130
A command prompt window opens.
2. At the Login prompt, type the initial default user ID, USERID. At the Password prompt, type the initial
default password, PASSW0RD(the sixth character is a zero, not the letter O). The user ID and password
are case sensitive.
This user account provides full access to the switch and its configuration. After planning your fabric
management needs and creating your own user accounts, consider changing the password for this account. See
“Commands” on page 6 for more information about authority levels. See the “User command” on page 62 for
information about creating user accounts.
✏ NOTE
The switch module supports a combined maximum of 15 logins. This includes the SAN Utility in-
band and out-of-band logins, Telnet out-of-band logins, and SNMP out-of-band logins. A maximum
of 10 SAN Utility logins are accepted. Additional logins will be refused.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Command syntax
The command syntax is as follows:
command
keyword
keyword [value]
keyword [value1] [value2]
The command is followed by one or more keywords. Consider the following rules and conventions:
•
•
Commands and keywords are lowercase and case sensitive.
Required keyword values are shown in standard font: [value]. Optional values are shown in italics:
[value].
•
The underlined portion of each keyword indicates the abbreviated form that can be used. For example the
Delete keyword can be abbreviated Del.
Commands
The command set provides for User and Admin authority levels.
•
•
User authority grants viewing access to the fabric and switches using the Show command and other read-
only commands.
Admin authority includes the User authority and grants permission to use the Admin command. The
Admin Start command opens an admin session, which provides access to the commands that change
switch and fabric configurations. See the “Admin command” on page 8.
✏ NOTE
Admin authority is enforced only if fabric security is enabled on the switch. By default, fabric
about setting fabric security.
The commands and their page numbers are listed by authority level in the followin table. The following Admin
session commands have some keywords that are available with User authority:
Alias
Config
Date
Set
User
Zone
Zoneset
Zoning
6
Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1. Commands listed by authority level
User authority commands
Admin authority command
(page 8)
Help
(page 15)
(page 17)
(page 21)
(page 22)
(page 42)
(page 49)
(page 52)
(page 54)
(page 56)
(page 61)
(page 64)
Admin
History
Ps
Admin session commands
Alias
(page 9)
Quit
Config
Date
(page 11)
(page 13)
(page 14)
(page 18)
(page 19)
(page 20)
(page 23)
(page 27)
(page 29)
(page 35)
(page 37)
(page 39)
(page 58)
(page 59)
(page 62)
(page 65)
(page 68)
(page 69)
Show
Show Config
Show Log
Show Perf
Show Setup
Uptime
Whoami
Fallback
Image
Lip
Passwd
Reset
Set
Set Config
Set Log
Set Port
Set Setup
Shutdown
Test
User
Zone
Zoneset
Zoning
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Admin command
Opens and closes an admin session. The admin session provides commands that change the fabric and switch
configurations. Only one admin session can be open on the switch at any time. An inactive admin session will
time out after a period of time that can be changed using the Set Setup System command. See the “Set Setup
Authority
Admin
Syntax
admin
start
end
cancel
Keywords
start
Opens the admin session.
end
Closes the admin session. The Logout, Shutdown, and Reset Switch commands will also end an
admin session.
cancel
Terminates an admin session opened by another user. Use this keyword with care because it
terminates the admin session without warning the other user and without saving pending changes.
Notes
Closing a Telnet window during an admin session does not release the session. In this case, you must either
wait for the admin session to time out, or use the Admin Cancel command.
Examples
The following example shows how to open and close an admin session.
FCSM: user1> admin start
FCSM: (admin) user1>
.
.
.
FCSM (admin) : user1> admin end
FCSM: user1>
8
Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Alias command
Creates a named set of ports. Aliases make it easier to assign a set of ports to many zones. An alias cannot have
a zone or another alias as a member.
Authority
Admin
Syntax
alias
add [alias] [members]
copy [alias_source] [alias_destination]
create [alias]
delete [alias]
list
members [alias]
remove [alias] [members]
rename [alias_old] [alias_new]
Keywords
add [alias] [members]
Specifies one or more ports given by [members] to add to the alias named [alias]. An alias can have a
maximum of 2000 members. [members] can have one of the following formats:
•
Domain ID and port number pair (domain ID, port number). Domain IDs and port numbers are in
decimal format. Ports are numbered beginning with 0.
•
•
6-character hexadecimal device Fibre Channel address (hex)
16-character hexadecimal port worldwide name (PWWN) with the format
xx:xx:xx:xx:xx:xx:xx:xx.
The application verifies that the [alias] format is correct but does not validate that such a port exists.
copy [alias_source] [alias_destination]
Creates a new alias named [alias_destination] and copies the membership into it from the alias given
by [alias_source].
create [alias]
Creates an alias with the name given by [alias]. An alias name must begin with a letter and be no
longer than 64 characters. Valid characters are 0-9, A-Z, a-z, &, _, and -. The zoning database
supports a maximum of 256 aliases.
delete alias
Deletes the specified alias given by [alias] from the zoning database. If the alias is a member of the
active zone set, the alias will not be removed from the active zone set until the active zone set is
deactivated.
list
Displays a list of all aliases. This keyword is valid for User authority and does not require a zoning
edit session or an admin session.
members [alias]
Displays all members of the alias given by [alias]. This keyword is available with User authority and
does not require a zoning edit session or an admin session.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
remove [alias] [members]
Removes the ports given by [members] from the alias given by [alias]. [members] can have one of the
following formats:
•
Domain ID and port number pair (domain ID, port number). Domain IDs and port numbers are in
decimal format. Ports are numbered beginning with 0.
•
•
6-character hexadecimal device Fibre Channel address (hex)
16-character hexadecimal port worldwide name (PWWN) for the device with the format
xx:xx:xx:xx:xx:xx:xx:xx.
rename [alias_old] [alias_new]
Renames the alias given by [alias_old] to the alias given by [alias_new].
10 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Config command
Manages the Fibre Channel configurations on a switch. For information about setting the port and switch
configurations, see the “Set Config command” on page 29.
Authority
Admin for all keywords except List
Syntax
config
activate [config]
backup
cancel
copy [config_source] [config_destination]
delete [config]
edit [config]
list
restore
save [config]
Keywords
activate [config]
Activates the configuration given by [config]. If the configuration is omitted, the currently active
configuration is used. Only one configuration can be active at a time.
backup
Creates a file named configdata, which contains the configuration information. To download this
file, open a File Transfer Protocol (FTP) session, log in with account name of imagesand password
of images, and type get configdata.
cancel
Terminates the current configuration edit session without saving changes.
copy [config_source] [config_destination]
Copies the configuration given by [config_source] to the configuration given by [config_destination].
The switch supports up to 10 configurations, including the default configuration.
delete [config]
Deletes the specified configuration file where [config] is the file name.
edit [config]
Opens an edit session for the configuration given by [config]. If the configuration name is omitted,
the currently active configuration is used.
list
Displays a list of all available configurations. This keyword is available with User authority.
restore
Restores configuration settings to an out-of-band switch from a backup file named configdata,
which must be first uploaded on the switch using FTP. Create the backup file using the Config
Backup command. Use FTP to load the backup file on a switch, and then enter the Config Restore
command.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
save [config]
Saves changes made during a configuration edit session in the configuration given by [config]. If the
configuration name value is omitted, the configuration you chose for the Config Edit command is
used.
Notes
If you edit the active configuration, changes will be suspended until you reactivate the configuration or activate
another configuration.
Examples
The following shows an example of how to open and close a Config Edit session.
FCSM: user1> admin start
FCSM (admin) : user1> config edit
.
.
.
FCSM (admin-config) : user1> config cancel
Configuration mode will be canceled.Please confirm (y/n): [n] y
FCSM (admin) : user1> admin end
12 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Date command
Displays or sets the blade server date and time. To set the date and time, you must provide the information
string in this format: MMDDhhmmCCYY, where MM = month, DD = day, hh = hour, mm = minute, CC =
century, and YY = year. You must reset the switch for the new date to take effect.
Authority
Admin to change the date; user to display the date.
Syntax
date
[MMDDhhmmCCYY]
Keywords
[MMDDhhmmCCYY]
Specifies the date – this requires an admin session. If you omit [MMDDhhmmCCYY], the current date
is displayed – this is available with User authority.
Examples
The following is an example of the Date command.
FCSM: user1> date
Thu Sep 26 07:51:24 2002
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Fallback command
Loads the fallback version of the firmware from switch memory. The switch stores two versions of the
firmware. This command alternately activates the two versions.
Authority
Admin
Syntax
fallback
Notes
•
The Show Switch command displays the available firmware versions and the currently active version.
After running the Fallback command, reset the switch for the firmware to be in effect.
•
Examples
The following is an example of the Fallback command.
FCSM: user1> admin start
FCSM (admin) : user1> fallback
Reverting to previous software image. Please confirm (y/n): [n] y
FCSM: user1> admin end
FCSM: user1>
14 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Help command
Displays a brief description of the specified command and its keywords.
Authority
User
Syntax
help
[command]
[keyword]
Keywords
[command]
A command name. If you omit this value, all available commands from which to choose are
displayed.
[keyword]
A keyword associated with the command named by [command]. If you omit this value, available
keywords for the specified command are displayed.
all
Displays a list of all available commands (including command variations).
Examples
The following is an example of the Help Set command.
FCSM: user1> help set
set SET_OPTIONS
There are many attributes that can be set.
Type help with one of the following to get more information:
set alarm
set beacon
set blade
set config blade
set config port
set config ports
set config switch
set config threshold
set config zoning
set log
set pagebreak
set port
set setup snmp
set setup system
set switch
15
Download from Www.Somanuals.com. All Manuals Search And Download.
The following is an example of the Help Set Beacon command.
FCSM: user1> help set beacon
set beacon On | Off
This command allows the lights on the front of the switch to flash.
The On option will start and the Off option will stop the flashing.
16 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
History command
Displays a numbered list of the previously entered commands from which you can re-execute selected
commands.
Authority
User
Syntax
history
Notes
Use the History command to provide context for the ! command.
•
•
•
•
Enter ![command] to re-enter the most recent execution of that command.
Enter ![line number] to re-execute the corresponding command from the History display
Enter ![partial command string] to re-execute a command that matches the command string.
Enter !! to re-execute the most recent command.
Examples
The following is an example of the History command.
FCSM: user1> history
1 show switch
2 date
3 help set
4 history
FCSM: user1> !2
date
Thu Sep 26 11:03:07 2002
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Image command
Manages and installs switch firmware.
Authority
Admin
Syntax
image
cleanup
fetch [account_name] [ip_address] [file_source] [file_destination]
list
unpack [file]
Keywords
cleanup
Removes all firmware image files from the switch. All firmware image files are removed
automatically each time the switch is reset.
fetch [account_name] [ip_address] [file_source] [file_destination]
Retrieves image file given by [file_source] and stores it on the switch with the file name given by
[file_destination]. The image file is retrieved from the device with the IP address given by
[Ip_address] and an account name given by [account_name]. If an account name needs a password to
access the device, you are prompted for it.
list
Displays the list of image files that reside on the switch.
unpack [file]
Installs the firmware file given by [file]. After unpacking the file, a message appears confirming
successful unpacking. The switch must be reset for the new firmware to take effect.
18 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Lip command (for external ports only)
Reinitializes the specified loop port.
Authority
Admin
Syntax
lip
[port_number]
Keywords
[port_number]
The number of the port to be reinitialized.
Examples
The following is an example of the Lip command.
FCSM (admin) : user1> lip 2
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Passwd command
Changes the password for a user account.
Authority
Admin to change the password for another account; user to change your own.
Syntax
passwd
[account_name]
Keywords
[account_name]
The user account name. You must open an admin session to change the password for an account name
other than your own. If you omit [account_name], you are prompted to change the password for the
current account name.
Examples
The following is an example of the Passwd command.
FCSM (admin) : user1> passwd user2
Press 'q' and the ENTER key to abort this command.
account OLD password
:
account NEW password (4-20 chars) :
please confirm account NEW password:
password has been changed.
✏ NOTE
20 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Ps command
Displays current blade server process information.
Authority
User
Syntax
ps
Examples
The following is an example of the Ps command.
FCSM: user1> ps
PID PPID %CPU
TIME
ELAPSED COMMAND
341 329 0.0 00:00:00 2-00:58:29 cns
342 329 0.0 00:00:02 2-00:58:29 ens
343 329 0.0 00:00:27 2-00:58:29 dlog
344 329 1.3 00:40:39 2-00:58:29 ds
345 329 1.4 00:41:38 2-00:58:29 mgmtApp
346 329 0.0 00:00:06 2-00:58:29 fc2
347 329 0.5 00:16:35 2-00:58:29 nserver
348 329 0.4 00:12:20 2-00:58:29 mserver
349 329 3.6 01:47:29 2-00:58:29 util
350 329 0.0 00:00:36 2-00:58:29 snmpservicepath
351 329 0.5 00:15:24 2-00:58:29 eport
352 329 0.0 00:00:05 2-00:58:29 PortApp
361 329 0.0 00:00:08 2-00:58:28 port_mon
362 329 0.2 00:07:14 2-00:58:28 zoning
363 329 0.0 00:00:00 2-00:58:28 diagApp
385 329 0.0 00:00:02 2-00:58:18 snmpd
386 329 0.0 00:00:00 2-00:58:18 snmpmain
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Reset command
Resets the switch and port configuration parameters.
Authority
Admin
Syntax
reset
config [config_name]
factory
port [port_number]
snmp
switch (default)
system
zoning
Keywords
config [config_name]
Resets the configuration given by [config_name] to the factory default values for switch, port, alarm
threshold, and zoning configuration. This keyword clears all zoning definitions. If [config_name]
does not exist on the switch, a configuration with that name is created. If you omit [config_name], the
active configuration is reset. You must activate the configuration or reset the switch for the changes to
take effect. See Table 2 on page 24 through Table 4 on page 25
factory
Resets switch, alarm threshold, port, SNMP, zoning configuration, and blade server configuration
settings to the factory default values. The switch configuration is activated automatically. See Table 2
on page 24 through Table 6 on page 26.
port [port_number]
Reinitializes the port given by [port_number]. Ports are numbered beginning with 0. For more
information, see Table 37 on page 131.
snmp
Resets the SNMP configuration settings to the factory default values. See Table 5 on page 26 for
SNMP configuration default values.
switch
system
Reinitializes the switch. This is the default. This command also closes the Telnet session.
Resets the blade server configuration settings to the factory default values. See Table 6 on page 26 for
configuration default values.
zoning
Clears the zoning database and deactivates the active zone set. The zoning configuration values
remain unchanged.
Notes
The following tables specify the various factory default settings.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 2. Switch configuration defaults
Parameter
Admin State
Default
Online
True
True
1
Broadcast Enabled
Inband Enable
Domain ID
Domain ID Lock
Symbolic Name
R_T_TOV
False
Fibre Channel Switch Module
100
R_A_TOV
10000
E_D_TOV
2000
FS_TOV
5000
DS_TOV
5000
Principal Priority
System Description
Configuration Last Saved By
Configuration Last Saved On
254
Fibre Channel Switch Module
Initial
Initial
Table 3. Port configuration defaults
Parameter
Admin State
Link Speed
Port Type
External port (0,15) default
Internal port (1-14) default
Online
Online
Auto
2 Gbps
GL
F
TL_Port Mode
ISL Security
Symbolic Name
ALFairness
ARB_FF
TLTargetMode
TLTargetMode
Any
Any
Port0 or Port15
Port1 – Port14
False
False
0
False
False
0
InteropCredit
ExtCredit
0
0
FanEnable
True
False
True
10
True
False
True
10
LCFEnable
MFSEnable
MFS_TOV
MSEnable
True
True
24 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 3. Port configuration defaults (continued)
Parameter External port (0,15) default
Internal port (1-14) default
False
NoClose
False
False
False
False
IOStreamGuard
VIEnable
False
False
False
CheckAlps
Table 4. Threshold configuration defaults
Parameter
Default
ThresholdMonitoringEnabled
True
CRCErrorsMonitoringEnabled
RisingTrigger
True
25
1
FallingTrigger
SampleWindow
10
DecodeErrorsMonitoringEnabled
RisingTrigger
True
200
0
FallingTrigger
SampleWindow
10
ISLMonitoringEnabled
RisingTrigger
True
2
FallingTrigger
0
SampleWindow
10
LoginMonitoringEnabled
RisingTrigger
True
5
FallingTrigger
1
SampleWindow
10
LogoutMonitoringEnabled
RisingTrigger
True
5
FallingTrigger
1
SampleWindow
10
LOSMonitoringEnabled
RisingTrigger
True
100
5
FallingTrigger
SampleWindow
10
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 5. SNMP configuration defaults
Parameter
Contact
Default
Undefined
Undefined
Undefined
10.0.0.1
0.0.0.0
Location
Description
Trap [1] Address
Trap [2-5] Address
Trap [1-5] Port
Trap [1-5] Severity
Trap [1-5] Enabled
ObjectID
162
Warning
False
1.3.6.1.4.1.1663.1.1.1.1.16
False
AuthFailureTrap
Table 6. System configuration defaults
Parameter
Default
Ethernet Network IP Address
Switch module bay 3: 192.168.70.129
Switch module bay 4: 192.168.70.130
Ethernet Network IP Mask
Ethernet Gateway Address
Ethernet Network Discovery
Admin Timeout
255.255.255.0
10.90.90.254
Static
30 minutes
False
Security Enabled
Local Log Enabled
True
Remote Log Enabled
Remote Log Host IP Address
False
10.0.0.254
26 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Set command
Sets a variety of port and switch parameters.
Authority
Admin for all keywords except Alarm Clear, Beacon, and Pagebreak which are available with User authority.
Syntax
set
alarm clear
beacon [state]
config [option]
log [option]
pagebreak [state]
port [option]
setup [option]
switch [state]
Keywords
alarm clear
Clears the alarm log. This keyword is available with User authority.
beacon [state]
Enables or disables the flashing of the Port Logged-in LEDs according to [state]. This keyword is
available with User authority. [state] can be one of the following:
On
Enables the flashing beacon.
Off
Disables the flashing beacon.
config [option]
Sets port, switch, alarm threshold, and zoning configuration parameters. See the “Set Config
log [option]
Specifies the type of entries to be entered in the event log. See the “Set Log command” on page 35.
pagebreak [state]
Specifies how much information is displayed on the screen at a time according to the value given by
[state]. This keyword is available with User authority. [state] can be one of the following:
On
Limits the display of information to 20 lines at a time.
Off
Allows continuous display of information without a break.
port [option]
Sets port state and speed for the specified port temporarily until the next switch reset or new
configuration activation. See the “Set Port command” on page 37.
setup [option]
Changes SNMP and blade server configuration settings. See the “Set Setup command” on page 39.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
switch [state]
Temporarily changes the administrative state for all ports on the switch to the state given by [state].
The previous Set Config Switch settings are restored after a switch reset or a reactivation of a switch
configuration. [state] can be one of the following:
Online
Places all ports online
Offline
Places all ports offline.
Diagnostics
Prepares all ports for testing.
28 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Config command
Sets port, switch, alarm threshold, and zoning configuration parameters.
Authority
Admin authority and a Config Edit session. See the “Config command” on page 11 for information about
starting a Config Edit session.
Syntax
set config
port [port_number]
ports [port_number]
switch
threshold
zoning
Keywords
port [port number]
Initiates an editing session in which to change configuration parameters for the port number given by
[port_number]. If you omit [port_number], the SBCE unit begins with port 0 and proceeds in order
through port 15. For each parameter, enter a new value or press the Enter key to accept the current
value shown in brackets. Type qto cancel the configuration for one port, or qqto cancel the
configuration for all ports. Table 7 describes the port parameters.
✏ NOTE
For external ports (0,15), all port parameters apply. For internal ports, only the port state
setting is configurable. For information about port numbering and mapping, see Table 37 on
ports [port number]
Initiates an editing session in which to change configuration parameters for all ports based on the
configuration for the port given by [port_number]. If you omit [port_number], port 0 is used. For each
parameter, enter a new value or press the Enter key to accept the current value shown in brackets.
Type qto cancel the configuration. Table 7 describes the port parameters. For external ports (0,15),
all parameters apply. For internal ports (1 through 14) only AdminState applies.
Table 7. Set Config port parameters
Parameter
AdminState
Description
Port administrative state: online, offline, diagnostics, or down.
1 Gbps or 2 Gbps
LinkSpeed
PortType
Type of port
TLPortMode
Initiates the configuration of external ports attributes. Indicates whether using
initiator or target devices on the loop. If you specify [port_number], the display will
present attributes for that port only; otherwise, all attributes for all ports will be
available for configuration.
ISLSecurity
E_Port security. Determines which switches a port will establish a link with.
•
•
•
Any - Will link with any switch.
Ours - Will link only to another Fibre Channel switch module.
None - The port will not establish an ISL link.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 7. Set Config port parameters (continued)
Parameter
Description
SymbolicPortName
ALFairness
ARB_FF
Descriptive name
Default is switch that has priority
Use ARB_FF instead of idles on loop FCAL option
Number of buffer-to-buffer credits per port. 0 means the default (12) is unchanged.
Extended credit port
InteropCredit
ExtCredit
FANEnable
Fabric Address Notification. If enabled, notifies logged-in NL_Ports of the FL_Port
address, port name, and node name.
LCFEnable
MFSEnable
MFS_TOV
MSEnable
NoClose
Link control frame preference, R_CTL = 0xC
Multi-frame sequence bundling
MFS limit for camp on
Management Server enable on this port
Do not close unless another device arbitrates
Enables or disables the suppression of RSCN messages
Not applicable
I/O Stream Guard
VIEnable
CheckAlps
Close before sending frames to new target
switch
Initiates an editing session in which to change switch configuration settings. Each parameter is
displayed, one line at a time and prompts you for a value. For each parameter, type a new value or
press the Enter key to accept the current value shown in brackets. Type qto cancel the configuration.
Table 8. Set Config switch parameters
Parameter
AdminState
Description
Switch administrative state: online, offline, or diagnostics.
Enables (True) or disables (False) forwarding if broadcasting frames.
Enables (True) or disables (False) the ability to manage the switch over an ISL.
Default domain ID setting.
Broadcast Enable
InbandEnabled
DefaultDomainID
DomainIDLock
SymbolicName
R_T_TOV
Prevents (True) or allows (False) dynamic reassignment of the domain ID.
Descriptive name
Receiver Transmitter Timeout Value. Specifies the number of milliseconds a port
is to wait to receive a response from another port. The default is 100.
R_A_TOV
Resource Allocation Timeout Value. The number of milliseconds the switch waits
to allow two ports to allocate enough resources to establish a link. The default is
10000.
E_D_TOV
FS_TOV
Error Detect Timeout Value. The number of milliseconds a port is to wait for errors
to clear. The default is 2000 msec.
Fabric Stability Timeout Value. The default is 5000 msec.
30 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 8. Set Config switch parameters (continued)
Parameter
Description
DS_TOV
Distributed Services Timeout Value (Management Server, Name Server). The
default is 5000 msec.
PrincipalPriority
ConfigDescription
The priority used in the FC-SW-2 principal switch selection algorithm. 1 is high,
255 is low.
The name for the configuration. The default is undefined.
threshold
Initiates a configuration session by which to generate and log alarms for selected events. Each event,
its thresholds, and sampling interval is displayed, one line at a time and you are prompted for a value.
For each parameter, enter a new value or press the Enter key to accept the current value shown in
brackets. These parameters must be saved in a configuration and activated before they will take effect.
See the “Config command” on page 11 for information about saving and activating a configuration.
Table 9 describes the Set Config threshold parameters.
Table 9. Set Config threshold parameters
Parameter
Description
Threshold Monitoring Enabled
Master enable/disable parameter for all events. Enables (True) or
disables (False) the generation of all enabled event alarms.
CRCErrorsMonitoringEnabled
DecodeErrorsMonitoringEnabled
ISLMonitoringEnabled
LoginMonitoringEnabled
LogoutMonitoringEnabled
LOSMonitoringEnabled
The event type enable/disable parameter. Enables (True) or disables
(False) the generation of alarms for each of the following events:
•
•
•
•
•
•
CRC errors
Decode errors
ISL connection count
Login errors
Logout errors
Loss-of-signal errors
Rising Trigger
The event count above which an event is logged. Once the count
exceeds the rising threshold, one alarm is logged. The switch will not
generate another alarm for that event until the count falls below the
falling threshold and rises again above the rising threshold.
Falling Trigger
The event count above which an event becomes eligible for logging in
the alarm log.
Sample Window
The period of time in seconds in which to count events.
zoning
Initiates an editing session in which to change switch zoning attributes. Each parameter is displayed,
one line at a time, and you are prompted for a value. For each parameter, enter a new value or press
the Enter key to accept the current value shown in brackets.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 10. Set Config zoning parameters
Parameter
Description
AutoSave
Determines whether zoning changes will be saved to flash (nonvolatile) memory
(On) or to RAM (volatile) (Off). The default is On.
Default
Determines communication among ports/devices in the absence of an active zone
set. “All” enables all ports/devices to communicate with one another. “None”
prohibits communication among ports/devices.
Examples
The following is an example of the Set Config Port command.
FCSM: user1> admin start
FCSM (admin) : user1> config edit
FCSM (admin-config) : user1> set config port 0
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Configuring Port Number: 0
------------------------
AdminState
LinkSpeed
PortType
(1=Online, 2=Offline, 3=Diagnostics, 4=Down) [Online
]
]
]
(1=1Gb/s, 2=2Gb/s, 3=Auto)
(TL / GL / G / F / FL / Donor)
(1=TLTargetMode, 2=TLInitiatorMode)
[Auto
[GL
TLPortMode
[TLTargetMode]
ISLSecurity (Any / Ours / None)
SymPortName (string, max=32 chars)
[Any
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
[Port0
[False
[False
[0
ALFairness
ARB_FF
(True / False)
(True / False)
InteropCredit (decimal value, 0-255)
ExtCredit
FANEnable
LCFEnable
MFSEnable
MFS_TOV
(dec value, increments of 11, non-loop only) [0
(True / False)
(True / False)
(True / False)
(decimal value, 10-20480 msec)
(True / False)
(True / False)
[True
[False
[True
[10
[True
[False
[Disabled
[False
[False
MSEnable
NoClose
IOStreamGuard (Enable / Disable)
VIEnable
CheckAlps
(True / False)
(True / False)
Finished configuring attributes.
This configuration must be saved (see config save command) and
activated (see config activate command) before it can take effect.
To discard this configuration use the config cancel command.
The following is an example of the Set Config Switch command.
32 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
FCSM: user1> admin start
FCSM (admin) : user1> config edit
FCSM (admin-config) : user1> set config switch
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
AdminState
BroadcastEnabled (True / False)
InbandEnabled (True / False)
DefaultDomainID (decimal value, 1-239)
(1=Online, 2=Offline, 3=Diagnostics) [Online]
[True]
[True]
[1]
DomainIDLock
SymbolicName
Module]
(True / False)
(string,max=32 chars)
[False]
[Fibre Channel Switch
R_T_TOV
R_A_TOV
E_D_TOV
FS_TOV
DS_TOV
(decimal value, 1-1000 msec)
(decimal value, 100-100000 msec)
(decimal value, 10-20000 msec)
(decimal value, 100-100000 msec)
(decimal value, 100-100000 msec)
[100]
[10000]
[2000]
[5000]
[5000]
PrincipalPriority (decimal value, 1-255)
ConfigDescription (string, max=64 chars)
Module]
Finished configuring attributes.
[254]
[Fibre Channel Switch
This configuration must be saved (see config save command) and
activated (see config activate command) before it can take effect.
To discard this configuration use the config cancel command.
The following is an example of the Set Config Threshold command.
FCSM (admin-config) : user1> set config threshold
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
ThresholdMonitoringEnabled
(True / False)
[False]
CRCErrorsMonitoringEnabled
RisingTrigger
(True / False)
(decimal value, 1-1000)
(decimal value, 0-1000)
[False]
[25 ]
FallingTrigger
[1
]
SampleWindow
(decimal value, 1-1000 sec) [10 ]
DecodeErrorsMonitoringEnabled
RisingTrigger
(True / False)
(decimal value, 1-1000)
(decimal value, 0-1000)
[True ]
[200 ]
FallingTrigger
[0
]
SampleWindow
(decimal value, 1-1000 sec) [10 ]
ISLMonitoringEnabled
RisingTrigger
(True / False)
(decimal value, 1-1000)
(decimal value, 0-1000)
[True ]
[2
[0
]
]
FallingTrigger
SampleWindow
(decimal value, 1-1000 sec) [10 ]
33
Download from Www.Somanuals.com. All Manuals Search And Download.
LoginMonitoringEnabled
RisingTrigger
(True / False)
(decimal value, 1-1000)
(decimal value, 0-1000)
[True ]
[5
[1
]
]
FallingTrigger
SampleWindow
(decimal value, 1-1000 sec) [10 ]
LogoutMonitoringEnabled
RisingTrigger
(True / False)
(decimal value, 1-1000)
(decimal value, 0-1000)
[True ]
[5
[1
]
]
FallingTrigger
SampleWindow
(decimal value, 1-1000 sec) [10 ]
LOSMonitoringEnabled
RisingTrigger
(True / False)
(decimal value, 1-1000)
(decimal value, 0-1000)
[True ]
[100 ]
FallingTrigger
SampleWindow
[5
]
(decimal value, 1-1000 sec) [10 ]
The following is an example of the Set Config Zoning command.
FCSM: user1> admin start
FCSM (admin) : user1> config edit
FCSM (admin-config) : user1> set config zoning
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
AutoSave
Default
(True / False) [True]
(All / None) [All ]
Finished configuring attributes.
This configuration must be saved (see config save command) and
activated (see config activate command) before it can take effect.
To discard this configuration use the config cancel command.
34 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Log command
Specifies the type of entries to be entered in the event log. The log is a storage file contained on the switch.
The log can hold a maximum of 200 entries. When the log becomes full, the entries are replaced, starting with
the oldest entry, to produce a list of the last 200 events which occurred. Log entries are created for ports,
components, and event severity levels.
Authority
Admin
Syntax
set log
archive
clear
component [list]
level [level]
port [port_list]
restore
save
start (default)
stop
Keywords
archive
Archives the log entries to a file on the switch named logfile that can be downloaded from the switch
using FTP. To download the log file, open an FTP session, log in with an account name of images
and password of images, and type get logfile.
clear
Clears all log entries.
component [list]
Specifies one or more components to monitor for events. Use spaces to delimit values in the list. Use
one or more of the following values:
All
Monitors all components. To maintain optimal switch performance, do not use this setting with
the Level keyword set to Info.
Blade
Not applicable
Chassis
Not applicable
Eport
Monitors all E_Ports.
Mgmtserver
Monitors management server status.
Nameserver
Monitors name server status.
None
Monitors none of the component events.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Other
Monitors other miscellaneous events.
Port
Monitors all port events.
Switch
Monitors switch management events.
Zoning
Monitors zoning conflict events.
level [level]
Specifies the severity level given by [level] to use in monitoring events for the specified components
or ports. [level] can be one of the following values:
Critical
Monitors critical events.
Warn
Monitors warning events.
Info
Monitors informational events. To maintain optimal switch performance, do not use this setting
with the Component keyword set to All.
None
Monitors none of the severity levels.
port [port_list]
Specifies one or more ports to monitor for events. Use one of the following values:
[port_list]
Specifies port or ports to monitor. Use spaces to delimit values in the list. Ports are numbered
beginning with 0.
All
Specifies all ports.
None
Disables monitoring on all ports.
restore
save
Returns the port, component, and level settings to the default values.
Saves the log settings for the component, level, and port. These settings remain in effect after a switch
reset. The log settings can be viewed using the Show Log Settings command. To export log entries to
a file, use the Set Log Archive command.
start
stop
Starts the logging of events based on the Port, Component, and Level keywords assigned to the
current configuration. The logging continues until you enter the Set Log Stop command.
Stops logging of events.
✏ NOTE
To maintain optimal switch performance, do not set the Component keyword to All and the
Level keyword to Info at the same time.
36 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Port command
Sets port state and speed for the specified port temporarily until the next switch reset or new configuration
activation. This command also clears port counters. For information about port numbering and mapping, see
✏ NOTE
For external ports (0,15), all port parameters apply. For internal ports, only the port state setting is
configurable.
Authority
Admin
Syntax
set port [port_number]
bypass [alpa] (for external ports only)
clear
enable [alpa] (for external ports only)
speed [transmission_speed]
state [state]
Keywords
[port_number]
Specifies the port. Ports are numbered beginning with 0. For information about port numbering and
mapping, see Table 37 on page 131.
bypass [alpa]
Sends a Loop Port Bypass (LPB) to a specific Arbitrated Loop Physical Address (ALPA) or to all
ALPAs on the arbitrated loop. [alpa] can be a specific ALPA or the keyword ALL to choose all
ALPAs.
clear
Clears the counters on the specified port.
enable [alpa]
Sends a Loop Port Enable (LPE) to all ALPAs on the arbitrated loop. [alpa] can be a specific ALPA
or the keyword ALL to choose all ALPAs.
speed [transmission_speed]
Specifies the transmission speed for the specified port. Use one of the following port speed values:
1Gbps
One gigabit per second.
2Gbps
Two gigabits per second.
Auto
The port speed is automatically detected.
state [state]
Specifies the administrative state for the specified port. Use one of the following port state values:
Online
Places the port online.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Offline
Places the port offline.
Diagnostics
Prepares the port for testing.
Down
Disables the port.
38 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Setup command
Changes SNMP and blade server configuration settings. The switch maintains one SNMP configuration and
one configuration.
Authority
Admin
Syntax
set setup
snmp
system
Keywords
snmp
Prompts you, line-by-line, to change SNMP configuration settings. Table 11 describes the SNMP
fields. For each parameter, enter a new value or press the Enter key to accept the current value shown
in brackets.
Table 11. SNMP configuration settings
Entry
Description
Contact
Location
Specifies the name of the person to be contacted to respond to trap events.
The default is Undefined.
Specifies the name of the switch location. The default is Undefined.
Specifies the IP address to which SNMP traps are sent.
Specifies the port for which SNMP traps are sent.
Trap [1-5] Address
Trap [1-5] Port
Trap [1-5] Severity
Specifies the severity level to use when monitoring trap events. The default is
Warning.
Trap [1-5] Enabled
ReadCommunity
Specifies whether traps (event information) are enabled or disabled (default).
Read Community Authentication. A write-only field; the value on the switch
and the SNMP management server must be the same.
WriteCommunity
TrapCommunity
AuthFailureTrap
Write Community Authentication. A write-only field; the value on the switch
and the SNMP management server must be the same.
Trap Community Authentication. A write-only field; the value on the switch and
the SNMP management server must be the same.
Specifies the IP address where a notification is sent in the event of an
authentication failure.
system
Prompts you, line-by-line, to change blade server configuration settings. Table 12 on page 40
describes the system configuration fields. For each parameter, enter a new value or press the Enter
key to accept the current value shown in brackets.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 12. System configuration settings
Entry
Description
Eth0NetworkAddress
Eth0NetworkMask
Ethernet Internet protocol (IP) address
Ethernet subnet mask address for the Ethernet port.
Ethernet IP address gateway
Eth0GatewayIPAddress
Eth0NetworkDiscovery
Ethernet boot method (1 - Static).
Note: BootP, DHCP, and RARP do not apply
AdminTimeout
Specifies the amount of time in minutes the switch waits before terminating an
idle Admin session. Zero (0) disables the time out threshold. The default is 30;
the maximum is 1440.
Security Enabled
Enables or disables the enforcement of account names and passwords.
Remote Log Enabled
Whether remote logging is enabled or disabled. If enabled, log information is
saved to a remote host that supports the syslog protocol.
RemoteLogHost IP Address The IP address of the host that will receive the remote log information if
remote logging is enabled.
✏ NOTE
The two components of security are user authentication and fabric security. The user must be
authenticated before gaining access to a switch. If an invalid account name/password combination is
entered, that user can not access the switch, and thus cannot gain access to the fabric. If security is
enabled (True) and a valid account name/password combination is entered, that user can access the
switch but can not execute any command that exceeds their authority (privileges) level. If security is
disabled (False) and a valid account name/password combination is entered, that user has access to all
switches in the fabric and can execute all commands (both user and admin), regardless of their
authority (privileges) level.
Examples
The following is an example of the Set Setup SNMP command.
FCSM: user1> admin start
FCSM (admin) : user1> set setup snmp
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Trap Severity Options
---------------------
unknown, emergency, alert, critical, error, warning, notify, info, debug, mark
Contact
Location
Trap1Address
Trap1Port
Trap1Severity
Trap1Enabled
(string, max=32 chars)
(string, max=32 chars)
(dot-notated IP Address)
(decimal value)
(see allowed options above) [warning
(True / False) [False
[<sysContact undefined> ]
[<sysLocation undefined>]
[10.0.0.1
[162
]
]
]
]
40 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Trap2Address
Trap2Port
Trap2Severity
Trap2Enabled
Trap3Address
Trap3Port
Trap3Severity
Trap3Enabled
Trap4Address
Trap4Port
Trap4Severity
Trap4Enabled
Trap5Address
Trap5Port
Trap5Severity
Trap5Enabled
ReadCommunity
WriteCommunity
TrapCommunity
AuthFailureTrap
(dot-notated IP Address)
(decimal value)
(see allowed options above) [warning
(True / False)
(dot-notated IP Address)
(decimal value)
(see allowed options above) [warning
(True / False)
(dot-notated IP Address)
(decimal value)
(see allowed options above) [warning
(True / False)
(dot-notated IP Address)
(decimal value)
(see allowed options above) [warning
(True / False)
(string, max=32 chars)
(string, max=32 chars)
(string, max=32 chars)
(True / False)
[0.0.0.0
[162
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
]
[False
[0.0.0.0
[162
[False
[0.0.0.0
[162
[False
[0.0.0.0
[162
[False
[public
[private
[public
[False
Do you want to save and activate this snmp setup? (y/n): [n]
The following is an example of the Set Setup System command.
FCSM: user1> admin start
FCSM (admin) : user1> set setup system
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Eth0NetworkAddress
Eth0NetworkMask
Eth0GatewayAddress
(dot-notated IP Address)
(dot-notated IP Address)
(dot-notated IP Address)
[10.90.10.93 ]
[255.255.252.0]
[10.20.8.254 ]
Eth0NetworkDiscovery (1=Static, 2=Bootp, 3=Dhcp, 4=Rarp) [Static
]
]
]
]
]
AdminTimeout
(dec value 0-1440 minutes, 0=never) [30
SecurityEnabled
LocalLogEnabled
RemoteLogEnabled
(True / False)
(True / False)
(True / False)
[False
[True
[False
RemoteLogHostAddress (dot-notated IP Address)
[10.0.0.254 ]
Do you want to save and activate this system setup? (y/n): [n]
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Show command
Displays fabric, switch, and port operational information.
Authority
User
Syntax
show
about
alarm
broadcast
chassis
config [option]
domains
donor
fabric
interface
log [option]
lsdb
mem [count]
ns [option]
pagebreak
perf [option]
port [port_number]
post log
setup [option]
steering [domain_id]
support
switch
topology
users
version
Keywords
about
Displays an introductory set of information about operational attributes of the switch. This keyword
is equivalent to the Version keyword.
alarm
Displays the last 200 alarm entries.
broadcast
Displays the broadcast tree information and all ports that are currently transmitting and receiving
broadcast frames.
chassis
Not applicable
42 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
config [option]
Displays switch and port configuration attributes. For more information, see the “Show Config
domains
Displays a list of each domain and its worldwide name in the fabric.
Displays list of current donor configuration for all ports.
donor
fabric
Displays list of each domain, fabric ID, worldwide name, node IP address, port IP address, and
symbolic name in the fabric.
interface
Displays the status of the active network interfaces.
log [option]
Displays log entries. See the “Show Log command” on page 52.
lsdb
mem [count]
Displays Link State database information.
Displays information about memory activity for the number of seconds given by [count]. If you omit
[count], the value 1 is used. Displayed memory values are in units of 1 KB.
✏ NOTE
This keyword will display memory activity updates until [count] is reached; it cannot be
interrupted. Therefore, avoid using large values for [count].
ns [option]
Displays name server information for the specified [option]. If you omit [option], name server
information for the local domain ID is displayed. [option] can have the following values:
all
Displays name server information for all switches and ports.
[domain_id]
Displays name server information for the switch given by [domain_id]. [domain_id] is a switch
domain ID.
[port_id]
Displays name server information for the port given by [port_id]. [port_id] is a port Fibre
Channel address.
pagebreak
Displays the current pagebreak setting. The pagebreak setting limits the display of information to 20
lines (On) or allows the continuous display of information without a break (Off).
perf [option]
Displays performance information for all ports. See the “Show Perf command” on page 54.
port [port_number]
Displays operational information for the port given by [port_number]. Ports are numbered beginning
with 0. If the port number is omitted, information is displayed for all ports. Table 13 on page 44
describes the port parameters. For information about port numbering and mapping, see Table 37 on
✏ NOTE
For external ports (0,15), all parameters apply. For internal ports (1 through 14) only
AdminState applies.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 13. Show Port parameters
Entry
Description
AIinit
Incremented each time the port begins AL initialization.
Number of times the port entered initialization and the initialization failed.
Number of class x frames received by this port.
Number of class x frames sent by this port.
AIinitError
ClassXFramesIn
ClassXFramesOut
ClassXWordsIn
ClassXWordsOut
DecodeError
EpConnects
FBusy
Number of class x words received by this port.
Number of class x words sent by this port.
Decoding error detected.
Number of times an E_Port connects through ISL negotiation.
Number of times the switch sent a F_BSY because Class 2 frame could not be
delivered within ED_TOV time. Number of class 2 and class 3 fabric busy
(F_BSY) frames generated by this port in response to incoming frames. This
usually indicates a busy condition on the fabric or N_port that is preventing
delivery of this frame.
Flowerrors
Received a frame when there were no available credits.
Number of frames from devices that were rejected.
Invalid CRC detected.
FReject
InvalidCRC
InvalidDestAddr
LIP ALPD ALPS
LIPF7ALPS
Invalid destination address detected.
Number of F7, AL_PS LIPs, or AL_PD (vendor specific) resets, performed.
This LIP is used to reinitialize the loop. An L_port, identified by AL_PS, may
have noticed a performance degradation and is trying to restore the loop.
LIPF8ALPS
LIPF7F7
This LIP denotes a loop failure detected by the L_port identified by AL_PS.
A loop initialization primitive frame used to acquire a valid AL_PA.
LIPF8F7
A loop initialization primitive frame used to indicate that a loop failure has been
detected at the receiver.
Link Failures
Number of optical link failures detected by this port. A link failure is a loss of
synchronization for a period of time greater than the value of R_T_TOV or by
loss of signal while not in the offline state. A loss of signal causes the switch to
attempt to re-establish the link. If the link is not re-established by the time
specified by R_T_TOV, a link failure is counted. A link reset is performed after
a link failure.
Login
Time when user logged in.
Logout
Time when user logged out.
LoopTimeouts
LossOfSync
A 2-second timeout as specified by FC-AL-2.
Number of synchronization losses (>100 ms) detected by this port. A loss of
synchronization is detected by receipt of an invalid transmission word.
PrimSeqErrors
RxLinkResets
Primitive sequence errors detected.
Number of link reset primatives received from an attached device.
44 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 13. Show Port parameters (continued)
Entry
Description
RxOfflineSeq
Number of offline sequences received. An OLS is issued for link initialization, a
Receive & Recognize Not_Operational (NOS) state, or to enter the offline
state.
TotalErrors
Total number of errors detected.
TotalLIPsRecvd
TotalLinkResets
TotalOfflineSeq
TotalRxFrames
TotalRxWords
TotalTxFrames
TotalTxWords
TxLinkResets
TxOfflineSeq
TxWait
Number of loop initialization primitive frames received by this port.
Total number of link reset primatives.
Total number of Offline Sequences issued by this port.
Total number of frames received by this port.
Total number of words received by this port.
Total number of frames issued by this port.
Total number of words issued by this port.
Number of Link Resets issued by this port.
Total number of Offline Sequences issued by this port.
Time waiting to transmit when blocked with no credit. Measured in FC Word
times.
post log
Displays the POST log which contains results from the POST.
setup [option]
steering [domain_id]
Displays the routes that data takes to the switch given by [domain_id]. If you omit [domain_id], the
system displays routes for all switches in the fabric.
support
Executes a series of commands that display a complete description of the switch, its configuration,
and operation. The display can be captured from the screen and used for diagnosing problems. This
keyword is intended for use at the request of your authorized maintenance provider. The following
commands are executed:
•
Date
•
•
•
•
•
•
Alias List
Config List
Date
History
Ps
Show (About, Alarm, Backtrace, Chassis, Config Port, Config Switch, Dev, Dev Settings,
Domains, Donor, Fabric, Log, Log Settings, Lsdb, Mem, Ns, Perf, Port, Setup Mfg, Setup Snmp,
Setup System, Steering, Switch, Topology, Users)
•
•
Uptime
User Accounts
45
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
•
Whoami
Zoneset (Active, List)
Zoning (History, Limits, List)
switch
Displays switch operational information.
topology
Displays all connected devices.
users
Displays a list of logged-in users. This is equivalent to the User List command.
version
Displays an introductory set of information about operational attributes of the switch. This keyword
is equivalent to the About keyword.
Examples
The following is an example of the Show Setup SNMP command.
FCSM: user1> show setup snmp
SNMP Information
----------------
Contact
<sysContact undefined>
Location
<sysLocation undefined>
Description
Trap1Address
Trap1Port
Fibre Channel Switch Module
10.0.0.1
162
Trap1Severity
Trap1Enabled
Trap2Address
Trap2Port
warning
False
0.0.0.0
162
Trap2Severity
Trap2Enabled
Trap3Address
Trap3Port
warning
False
0.0.0.0
162
Trap3Severity
Trap3Enabled
Trap4Address
Trap4Port
warning
False
0.0.0.0
162
Trap4Severity
Trap4Enabled
Trap5Address
Trap5Port
warning
False
0.0.0.0
162
Trap5Severity
Trap5Enabled
ObjectID
warning
False
1.3.6.1.4.1.1663.1.1.1.1.16
False
AuthFailureTrap
46 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
The following is an example of the Show Topology command.
FCSM: user1> show topology
Unique ID Key
-------------
A = ALPA, D = Domain ID, P = Port ID
Loc
Port
----
Local
Type PortWWN
---- -------
Rem Remote
Type NodeWWN
---- -------
Unique
ID
------
Ext:15 E
20:0f:00:c0:dd:00:90:fb E
10:00:00:c0:dd:00:90:d74 (0x4) D
The following is an example of the Show Topology (for Port #15) command.
FCSM: user1> show topology 15
Local Link Information
----------------------
Port
Ext2:15
PortID
PortWWN
020f00
20:0f:00:c0:dd:00:90:fb
PortType E
Remote Link Information
-----------------------
Remote Switch
PortNumber 10
DomainID
NodeWWN
PortType
04
10:00:00:c0:dd:00:90:d7
E
Description Switch
IPAddress 10.0.0.3
The following is an example of the Show Port command.
FCSM: user1> show port 0
Port Number: 0
------------
AdminState
AsicNumber
AsicPort
Online
0
0
GL
Passed
Connected
NotApplicable
2Gb/s
Active
LoggedIn
12
PortID
PortWWN
640000
20:00:00:c0:dd:00:91:03
E
FTRJ-8519-3-2.5
X1
100-M5-SN-I
FINISAR CORP.
00659000
Port0
RunningType
SFPPartNumber
SFPRevision
SFPType
SFPVendor
SFPVendorID
SymbolicName
SyncStatus
ConfigType
DiagStatus
EpConnState
EpIsoReason
LinkSpeed
LinkState
LoginStatus
MaxCredit
SyncAcquired
XmitterEnabled True
OperationalState Online
ALInit
ALInitError
11
1
FlowErrors
FReject
0
0
PrimSeqErrors 0
RxLinkResets
0
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Class2FramesIn 0
Class2FramesOut 0
Class2WordsIn 0
Class2WordsOut 0
Class3FramesIn 0
Class3FramesOut 0
InvalidCRC
InvalidDestAddr 0
LIP_AL_PD_AL_PS 0
LIP_F7_AL_PS
LIP_F7_F7
LIP_F8_AL_PS
LIP_F8_F7
LinkFailures
Login
0
RxOfflineSeq
TotalErrors
TotalLIPsRecvd 15
TotalLinkResets 0
TotalOfflineSeq 0
TotalRxFrames 0
TotalRxWords
TotalTxFrames 0
TotalTxWords
TxLinkResets
TxOfflineSeq
TxWaits
0
1
0
15
0
0
0
7
6
0
1
Class3Toss
0
0
Class3WordsIn 0
Class3WordsOut 0
0
0
0
0
DecodeErrors
EpConnects
FBusy
0
7
0
Logout
LoopTimeouts
LossOfSync
The following is an example of the Show Switch command.
FCSM: user1> show switch
Switch Information
------------------
SymbolicName
SwitchWWN
SwitchType
Fibre Channel Switch Module
10:00:00:c0:dd:00:91:03
generic
PROMVersion
CreditPool
V1.4.0.1-0 (Thu Sep 12 17:46:41 2002)
0
DomainID
1 (0x1)
010000
128
Critical
16
FirstPortAddress
FlashSize - MBytes
LogLevel
MaxPorts
NumberOfResets
ReasonForLastReset
14
NormalReset
SWImageVersion (1) - build date V1.4.0.18-3 (Thu Sep 19 03:55:16 2002)
SWImageVersion (2) - build date V1.4.0.19-1 (Fri Sep 20 03:56:20 2002)
ActiveConfiguration
ActiveSWImage
default
2
AdminState
Online
False
False
Online
True
AdminModeActive
BeaconOnStatus
OperationalState
PrincipalSwitchRole
BoardTemp (1) - Degrees Celsius 50
BoardTemp (2) - Degrees Celsius 50
SwitchDiagnosticsStatus
SwitchTemperatureStatus
Passed
Normal
48 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Show Config command
Display port, switch, alarm threshold, and zoning attributes for the current configuration.
Authority
User
Syntax
show config
port [port_number]
switch
threshold
zoning
Keywords
port [port_number]
Displays configuration parameters for the port number given by [port_number]. Ports are numbered
beginning with 0. If the port value is omitted, all ports are specified.
✏ NOTE
For external ports (0,15), all parameters apply. For internal ports (1 through 14) only
AdminState applies. For information about port numbering and mapping, see Table 37 on
switch
Displays configuration parameters for the switch.
threshold
Displays alarm threshold parameters for the switch.
zoning
Displays zoning configuration parameters for the switch.
Examples
The following is an example of the Show Config Port command.
FCSM: user1> show config port 15
Configuration Name: lei
-------------------
Port Number: 15
------------
AdminState
LinkSpeed
PortType
Online
Auto
GL
TLPortMode
ISLSecurity
SymbolicName
ALFairness
ARB_FF
InteropCredit
ExtCredit
FANEnable
LCFEnable
MFSEnable
TLTargetMode
Any
Port15
False
False
0
0
True
False
True
49
Download from Www.Somanuals.com. All Manuals Search And Download.
MFS_TOV
10
MSEnable
NoClose
IOStreamGuard
VIEnable
CheckAlps
True
False
Disabled
False
False
The following is an example of the Show Config Switch command.
FCSM: user1> show config switch
Configuration Name: lei
-------------------
Switch Configuration Information
--------------------------------
AdminState
Online
BroadcastEnabled
InbandEnabled
DomainID
True
True
1 (0x1)
DomainIDLock
SymbolicName
R_T_TOV
False
Fibre Channel Switch Module
100
R_A_TOV
10000
E_D_TOV
2000
FS_TOV
5000
DS_TOV
5000
PrincipalPriority
ConfigDescription
ConfigLastSavedBy
ConfigLastSavedOn
254
Fibre Channel Switch Module
Initial
Initial
The following is an example of the Show Config Threshold command.
FCSM: user1> show config threshold
Configuration Name: default
-------------------
Threshold Configuration Information
-----------------------------------
ThresholdMonitoringEnabled
CRCErrorsMonitoringEnabled
RisingTrigger
True
True
25
FallingTrigger
1
SampleWindow
10
DecodeErrorsMonitoringEnabled True
RisingTrigger
FallingTrigger
SampleWindow
200
0
10
True
2
ISLMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
LoginMonitoringEnabled
RisingTrigger
0
10
True
5
50 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
FallingTrigger
SampleWindow
LogoutMonitoringEnabled
RisingTrigger
1
10
True
5
FallingTrigger
SampleWindow
LOSMonitoringEnabled
RisingTrigger
1
10
True
100
5
FallingTrigger
SampleWindow
10
The following is an example of the Show Config Zoning command.
FCSM: user1> show config zoning
Configuration Name: default
-------------------
Zoning Configuration Information
--------------------------------
AutoSave
Default
True
All
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Show Log command
Displays the contents of the log or the parameters used to create entries in the log. The log contains a
maximum of 200 entries. When the log reaches its entry capacity, subsequent entries overwrite the existing
entries, beginning with the oldest.
Authority
User
Syntax
show log
component
level
options
port
settings
Keywords
component
Displays the components currently being monitored for events.
level
Displays the event severity level needed to create an entry in the log. If the severity level occurs on a
port or on a component which is not defined, no entry is made in the log.
options
Displays the options used to set the component and log level attributes.
port
Displays the ports being monitored for events. If an event occurs which is of the defined level and on
a defined component, but not on a defined port, no entry is made in the log.
settings
Displays the current settings for component, level and port. This command is equivalent to executing
the following commands separately: Show Log Component, Show Log Level, and Show Log Port.
Examples
The following is an example of the Show Log Component command.
FCSM: user1> show log component
Current setting(s) for log component: NameServer
The following is an example of the Show Log Level command.
FCSM: user1> show log level
Current settings for log
------------------------
level
Critical
52 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
The following is an example of the Show Log Options command.
FCSM: user1> show log options
Allowed options for '
level': Critical,Warn,Info,None
Allowed options for 'component':
All,None,NameServer,MgmtServer,Zoning,Switch,Chassis,Blade,Port,Eport,Snmp,Other
Current setting(s) for log port: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
The following is an example of the Show Log command.
[327][Wed Jan 25 09:36:54.860 1989][I][Eport:0xdd00b8b6.304.4 Port: 0/8][Eport
State = E_A0_GET_DOMAIN_ID]
[328][Wed Jan 25 09:36:54.860 1989][I][Eport:0xdd00b8b6.304.4 Port: 0/8][FSPF
PortUp state=0]
[329][Wed Jan 25 09:36:54.861 1989][I][Eport:0xdd00b8b6.304.4 Port: 0/8][Send ing
init hello]
[330][Wed Jan 25 09:36:54.861 1989][I][Eport:0xdd00b8b6.304.4 Port: 0/8][Proc
essing EFP, oxid= 0x8]
[331][Wed Jan 25 09:36:54.861 1989][I][Eport:0xdd00b8b6.304.4 Port: 0/8][Eport
State = E_A2_IDLE]
[332][Wed Jan 25 09:36:54.861 1989][I][Eport:0xdd00b8b6.304.4 Port: 0/8][EFP, WWN=
0x100000c0dd00b845, len= 0x30]
[333][Wed Jan 25 09:36:54.864 1989][I][Eport:0xdd00b8b6.304.4 Port: 0/8][Sending
LSU oxid= 0xc: type= 1]
[334][Wed Jan 25 09:36:54.864 1989][I][Eport:0xdd00b8b6.304.4 Port: 0/8][Send Zone
Merge Request]
[335][Wed Jan 25 09:36:54.865 1989][I][Eport:0xdd00b8b6.304.4 Port: 0/8][LSDB Xchg
timer set]
[336][Wed Jan 25 09:36:54.865 1989][I][Eport:0xdd00b8b6.304.4 Port: 0/8][Setting
attribute Oper.UserPort.0.8.EpConnState Connected]
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Show Perf command
Displays port performance in frames per second and bytes per second. If you omit the keyword, the command
displays data transmitted (out), data received (in), and total data transmitted and received in frames per second
and bytes per second.
Authority
User
Syntax
show perf
byte
inbyte
outbyte [port_number]
frame [port_number]
inframe [port_number]
outframe [port_number]
errors [port_number]
Keywords
byte
Displays continuous performance data in total bytes per second transmitted and received for all ports.
Type qand press the Enter key to stop the display.
inbyte
Displays continuous performance data in bytes per second received for all ports. Type qand press the
Enter key to stop the display.
outbyte [port_number]
Displays continuous performance data in bytes per second transmitted for all ports. Type qand press
the Enter key to stop the display.
frame [port_number]
Displays continuous performance data in total frames per second transmitted and received for all
ports. Type qand press the Enter key to stop the display.
inframe [port_number]
Displays continuous performance data in frames per second received for all ports. Type qand press
the Enter key to stop the display.
outframe [port_number]
Displays continuous performance data in frames per second transmitted for all ports. Type qand
press the Enter key to stop the display.
errors [port_number]
Displays continuous error counts for all ports. Type qand press the Enter key to stop the display.
54 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Examples
The following is an example of the Show Perf command.
FCSM: user1>: show perf
Bytes/s
(in)
-------
Bytes/s
(out)
-------
0
0
Bytes/s
(total)
-------
0
Frames/s Frames/s Frames/s
(in) (out) (total)
-------- -------- --------
Port
----
Ext1:0 0
Ext2:15 0
0
0
0
0
0
0
0
Bay1
Bay2
Bay3
Bay4
Bay5
Bay6
Bay7
Bay8
Bay9
Bay10 0
Bay11 0
Bay12 0
Bay13 0
Bay14 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Show Setup command
Displays the current SNMP and system settings.
Authority
User
Syntax
show setup
mfg
snmp
system
Keywords
mfg
Displays manufacturing information about the switch.
snmp
Displays the current SNMP settings.
Displays the current system settings.
system
Examples
The following is an example of the Show Setup Mfg command.
FCSM: user1> show setup mfg
Manufacturing Information
-------------------------
BoardSerialNumber
BrandName
P9
BuildDate
Unknown
ChassisPartNumber
ChassisSerialNumber
MACAddress
PlanarPartNumber
SwitchSymbolicName
SwitchWWN
Unknown
P9
00:c0:dd:00:91:02
Unknown
Fibre Channel Switch Module
10:00:00:c0:dd:00:91:03
Fibre Channel Switch Module
1.3.6.1.4.1.1663.1.1.1.1.16
SystemDescription
SystemObjectID
56 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
The following is an example of the Show Setup Snmp command.
FCSM: user1> show setup snmp
SNMP Information
----------------
Contact
<sysContact undefined>
Location
<sysLocation undefined>
Description
Trap1Address
Trap1Port
Fibre Channel Switch Module
10.0.0.254
162
Trap1Severity
Trap1Enabled
Trap2Address
Trap2Port
warning
False
0.0.0.0
162
Trap2Severity
Trap2Enabled
Trap3Address
Trap3Port
warning
False
0.0.0.0
162
Trap3Severity
Trap3Enabled
Trap4Address
Trap4Port
warning
False
0.0.0.0
162
Trap4Severity
Trap4Enabled
Trap5Address
Trap5Port
warning
False
0.0.0.0
162
Trap5Severity
Trap5Enabled
ObjectID
warning
False
1.3.6.1.4.1.1663.1.1.1.1.16
False
AuthFailureTrap
The following is an example of the Show Setup System command.
FCSM: user1> show setup system
System Information
------------------
Eth0NetworkAddress
Eth0NetworkMask
Eth0GatewayAddress
Eth0NetworkDiscovery
AdminTimeout
10.20.8.188
255.255.252.0
10.20.8.254
Static
30
SecurityEnabled
False
LocalLogEnabled
True
RemoteLogEnabled
RemoteLogHostAddress
False
10.0.0.254
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Shutdown command
Terminates all data transfers on the switch at convenient points and closes the Telnet session. Always power
cycle the switch after entering this command.
Authority
Admin
Syntax
shutdown
✏ NOTE
Always use this command to effect an orderly shutdown before removing power from the switch.
Failure to do so could damage the flash memory and the switch configuration.
58 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Test command
Tests switch module ports using internal (SerDes level), external small form-factor pluggable (SFP), and
online loopback tests. Internal and external tests require that the switch module port be placed in diagnostic
mode. See the “Set Port command” on page 37 for information about changing the port administrative state.
While the test is running, the remaining ports on the switch remain fully operational. See “Port testing” on
page 124 for more information.
Authority
Admin
Syntax
test
port [port_number] [test_type]
cancel
status
Keywords
port [port_number] [test_type]
Tests the port given by [port_number] using the test given by [test_type]. If you omit [test_type],
Internal is used. [test_type] can have the following values:
Internal (for internal and external ports)
Tests the SerDes. This is the default. The port must be in diagnostics mode to perform this test.
External (for external ports only)
Tests both the SerDes and SFP. The port must be in diagnostics mode to perform this test, and a
loopback plug must be installed in the SFP.
Online (for internal and external ports)
Tests one online port.
cancel
status
Cancels the online test in progress.
Displays the status of a test in progress, or if there is no test in progress, the status of the test that was
executed last.
Examples
To run Internal (SerDes) or External (SFP) port tests, complete the following steps:
1. To start an admin session, type the following command:
admin start
2. Place the port in Diagnostics mode by typing the following command (x = port number):
set port x state diagnostics
3. Insert the loopback plug into the SFP on the selected port (for external port test only).
59
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Choose one of the two types of port loopback tests to run:
•
To run an internal loopback test, type the following command:
test x internal
•
To run an external loopback test, type the following command. A loopback plug must be installed for
this test to pass.
test x external
✏ NOTE
The external loopback test can be performed only on external switch module ports.
After the test type has been chosen and the command executed, a message on the screen will appear
detailing the test results.
5. After the test is run, put the port back into online state by typing the following command (x = port
number):
set port x state online
6. To verify the port is back online, type the following command. The contents of the AdminState field
should be Online.
show port x
The online node-to-node test can test only one port at a time, and that port must be online and connected to an
external device or a blade server Fibre Channel expansion card. To run the online node-to-node test, complete
the following steps:
1. To start an admin session, type the following command:
admin start
2. To run the online node-to-node test, type the following command:
test x online
A series of test parameters are displayed on the screen.
3. Press the Enter key to accept each default parameter value, or type a new value for each parameter and
press the Enter key. The TestLength parameter is the number of frames sent, the FrameSize (256 byte
maximum in some cases) parameter is the number of bytes in each frame, and the DataPattern parameter
is the pattern in the payload. Before running the test, make sure that the device attached to the port can
handle the test parameters.
FCSM (admin) : user1> test x online
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the default value. If
you wish to terminate this process before reaching the end of the list press
'q'
or 'Q' and the ENTER key to do so.
TestLength
FrameSize
(decimal value, 1-4294967295) [100
(decimal value, 36-2148) [256
]
]
DataPattern (32-bit hex value or 'Default') [Default]
StopOnError (True/False)
[False ]
Do you want to start the test? (y/n) [n]
4. After all parameter values are defined, press the Y key to start the test.
60 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Uptime command
Displays the elapsed time since the switch was last reset and reset method.
Authority
User
Syntax
uptime
Examples
The following is an example of the Uptime command.
FCSM: user1> uptime
Elapsed up time : 0 day(s), 2 hour(s), 28 min(s), 44 sec(s)
Reason last reset: NormalReset
61
Download from Www.Somanuals.com. All Manuals Search And Download.
User command
Administers or displays user accounts.
Authority
Admin. The List keyword is available with User authority.
Syntax
user
accounts
add
delete [account_name]
list
Keywords
accounts
Displays all user accounts that exist on the switch.
add
Add a user account to the switch. After this command is executed, the administrator will be prompted
for the information needed to establish the user account. A switch can have a maximum of 15 user
accounts. Account names are limited to 15 characters; passwords are limited to 31 characters.
delete [account_name]
Deletes the account name given by [account_name] from the switch.
list
Displays the list of users currently logged in and their session numbers. Provides the same function as
the Show Users command. This keyword is valid for User authority and does not require an admin
session.
Examples
The following is an example of the User Accounts command.
FCSM (admin) : user1> user accounts
Current list of user accounts
-----------------------------
images
admin
USERID
(admin authority = False)
(admin authority = True)
(admin authority = True)
The following is an example of the User Add command.
FCSM (admin) : user1> user add
Press 'q' and the ENTER key to abort this command.
account name (1-15 chars)
: user3
account password (4-20 chars) :
please confirm account password:
should this account have admin authority? (y/n) [n] : y
OK to add user account 'user3' with admin authority?
Please confirm (y/n): [n] y
62 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
The following is an example of the User Delete command.
FCSM (admin) : user1> user del user3
The user account will be deleted. Please confirm (y/n): [n] y
The following is an example of the User List command.
FCSM (admin) : user1> user list
Current list of users logged in
-------------------------------
admin@OB-session1 - in admin mode
admin@OB-session2
user1@OB-session3
63
Download from Www.Somanuals.com. All Manuals Search And Download.
Whoami command
CommandDisplays the account name, session number, and switch domain ID for the Telnet session.
Authority
User
Syntax
whoami
Examples
The following is an example of the Whoami command.
FCSM: user1> whoami
User name
: admin@OB-session3
Switch name
: Fibre Channel Switch Module
Switch domain ID: 100 (0x64)
64 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Zone command
Manages zones and zone membership on a switch. The Zone command defines members (ports and devices)
for a single switch. Zones are members of zone sets.
Authority
Admin authority and a Zoning Edit session. See the “list” on page 69 for information about starting a Zoning
Edit session. The List, Members, and Zonesets keywords are available with User authority and do not require a
Zoning Edit session.
Syntax
zone
add [zone] [members]
copy [zone_source] [zone_destination]
create [zone]
delete [zone]
list
members [zone]
remove [zone] [members]
rename [zone_old] [zone_new]
type [zone] [zone_type]
zonesets [zone]
Keywords
add [zone] [members]
Specifies one or more ports given by [members] to add to the zone named [zone]. A zone can have a
maximum of 256 members. [members] can have one of the following formats:
•
Domain ID and port number pair (domain ID, port number). Domain IDs and port numbers are in
decimal format. Ports are numbered beginning with 0.
•
•
6-character hexadecimal device Fibre Channel address (hex)
16-character hexadecimal port worldwide name (PWWN) with the format
xx:xx:xx:xx:xx:xx:xx:xx.
•
Alias name
The application verifies that the [zone] format is correct, but does not validate that such a port exists.
copy [zone_source] [zone_destination]
Creates a new zone named [zone_destination] and copies the membership into it from the zone given
by [zone_source].
create [zone]
Creates a zone with the name given by [zone]. An zone name must begin with a letter and be no
longer than 64 characters. Valid characters are 0-9, A-Z, a-z, &, _, and -. The zoning database
supports a maximum of 256 zones.
delete [zone]
Deletes the specified zone given by [zone] from the zoning database. If the zone is a member of the
active zone set, the zone will not be removed from the active zone set until the active zone set is
deactivated.
65
Download from Www.Somanuals.com. All Manuals Search And Download.
list
Displays a list of all zones and the zone sets of which they are members. This keyword is valid for
User authority and does not require a zoning edit session.
members [zone]
Displays all members of the zone given by [zone]. This keyword is available with User authority and
does not require a Zoning Edit session.
remove [zone] [members]
Removes the ports given by [members] from the zone given by [zone]. [members] can have one of the
following formats:
•
Domain ID and port number pair (Domain ID, Port Number). Domain IDs and port numbers are
in decimal. Ports are numbered beginning with 0.
•
•
6-character hexadecimal device Fibre Channel address (hex)
16-character hexadecimal port worldwide name (PWWN) with the format
xx:xx:xx:xx:xx:xx:xx:xx.
•
Alias name
rename [zone_old] [zone_new]
Renames the zone given by [zone_old] to the zone given by [zone_new].
type [zone] [zone_type]
Specifies the zone type given by [zone_type] to be assigned to the zone name given by [zone]. If you
omit the [zone_type], the system displays the zone type for the zone given by [zone]. [zone_type] can
be one of the following:
soft
Name server zone
hardacl
Access control list hard zone
hardvpf
Virtual private fabric hard zone
zonesets [zone]
Displays all zone sets of which the zone given by [zone] is a member. This keyword is available with
User authority and does not require a Zoning Edit session.
Examples
The following is an example of the Zone List command.
FCSM: user1> zone list
Zone
ZoneSet
-------------------
wwn_b0241f
zone_set_1
wwn_23bd31
wwn_221416
wwn_2215c3
zone_set_1
zone_set_1
zone_set_1
66 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
wwn_0160ed
wwn_c001b0
wwn_401248
wwn_02402f
wwn_22412f
zone_set_1
zone_set_1
zone_set_1
zone_set_1
zone_set_1
The following is an example of the Zone Members command.
FCSM: user1> zone members wwn_b0241f
Current List of Members for Zone: wwn_b0241f
---------------------------------
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
21:00:00:e0:8b:02:41:2f
The following is an example of the Zone Zonesets command.
FCSM: user1> zone zonesets zone1
Current List of ZoneSets for Zone: wwn_b0241f
----------------------------------
zone_set_1
67
Download from Www.Somanuals.com. All Manuals Search And Download.
Zoneset command
Manages zone sets and zone set membership across the fabric.
Authority
Admin authority and a Zoning Edit session. See the “list” on page 69 for information about starting a Zoning
Edit session. The Active, List, Zones keywords are available with User authority. You must close the Zoning
Edit session before using the Activate and Deactivate keywords.
Syntax
zoneset
activate [zone_set]
active
add [zone_set] [zone_list]
copy [zone_set_source] [zone_set_destination]
create [zone_set]
deactivate
delete [zone_set]
list
remove [zone_set] [zone_list]
rename [zone_set_old] [zone_set_new]
zones [zone_set]
Keywords
activate [zone_set]
Activates the zone set given by [zone_set]. This keyword deactivates the active zone set. Close the
Zoning Edit session before using this keyword.
active
Displays the name of the active zone set. This keyword is available with User authority and does not
require a Zoning Edit session.
add [zone_set] [zone_list]
Adds a list of zones and aliases given by [zone_list] to the zone set given by [zone_set]. Zone and
alias names are delimited by spaces in [zone_list]. This keyword requires a Zoning Edit session.
copy [zone_set_source] [zone_set_destination]
Creates a new zone set named [zone_set_destination] and copies into it the membership from the
zone set given by [zone_set_source]. This keyword requires a Zoning Edit session.
create [zone_set]
Creates the zone set with the name given by [zone_set]. A zone set name must begin with a letter and
be no longer than 64 characters. Valid characters are 0-9, A-Z, a-z, &, _, and -. This keyword requires
a Zoning Edit session. The zoning database supports a maximum of 256 zone sets.
deactivate
Deactivates the active zone set. Close the Zoning Edit session before using this keyword.
delete [zone_set]
Deletes the zone set given by [zone_set]. If the specified zone set is active, the command is suspended
until the zone set is deactivated. This keyword requires a Zoning Edit session.
68 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
list
Displays a list of all zone sets. This keyword is available with User authority and does not require a
Zoning Edit session.
remove [zone_set] [zone_list]
Removes a list of zones and aliases given by [zone_list] from the zone set given by [zone_set]. Zone
and alias names are delimited by spaces in [zone_list]. If [zone_set] is the active zone set, the zone
will not be removed until the zone set has been deactivated. This keyword requires a Zoning Edit
session.
rename [zone_set_old] [zone_set_new]
Renames the zone set given by [zone_set_old] to the name given by [zone_set_new]. You can rename
the active zone set. This keyword requires a Zoning Edit session.
zones [zone_set]
Displays all zones that are members of the zone set given by [zone_set]. This keyword is available
with User authority and does not need a Zoning Edit session.
Notes
•
A zone set must be active for its definitions to be applied to the fabric.
Only one zone set can be active at one time.
•
•
A zone can be a member of more than one zone set.
Examples
The following is an example of the Zoneset Active command.
FCSM: user1> zoneset active
The active ZoneSet is: Beta
The following is an example of the Zoneset List command.
FCSM: user1> zoneset list
Current List of ZoneSets
------------------------
alpha
beta
The following is an example of the Zoneset Zones command.
FCSM: user1> zoneset zones ssss
Current List of Zones for ZoneSet: ssss
----------------------------------
zone1
zone2
zone3
69
Download from Www.Somanuals.com. All Manuals Search And Download.
Zoning command
Opens a Zoning Edit session in which to create and manage zone sets and zones. See the “Zone command” on
Authority
Admin. The List keyword is available with User authority.
Syntax
zoning
active
cancel
clear
edit
history
limits
list
restore
save
Keywords
active
Displays membership information for the active zone set including member zones and zone members.
cancel
Closes the current Zoning Edit session. Any unsaved changes are lost.
clear
Clears all inactive zone sets from the volatile edit copy of the zoning database. This keyword does not
affect the nonvolatile zoning database. However, if you enter the Zoning Clear command followed by
the Zoning Save command, the nonvolatile zoning database will be cleared from the switch. The
preferred method for clearing the zoning database from the switch is the Reset Zoning command.
edit
Opens a Zoning Edit session.
history
Displays a history of zoning modifications including the following:
•
•
•
Time of the most recent zone set activation or deactivation and the user who performed it
Time of the most recent modifications to the zoning database and the user who made them.
Checksum for the zoning database.
limits
Displays the maximum limits imposed on the zoning database for the number of zone sets, zones,
aliases, members per zone, members per alias, and total members.
list
Lists all fabric zoning definitions. This keyword is available with User authority.
restore
Reverts the changes to the zoning database that have been made during the current Zoning Edit
session since the last Zoning Save command was entered.
70 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
save
Saves changes made during the current Zoning Edit session. The system will inform you that the zone
set must be activated to implement any changes. This does not apply if you entered the Zoning Clear
command during the Zoning Edit session.
Examples
The following is an example of the Zoning Edit command.
FCSM: user1> admin start
FCSM (admin) : user1> zoning edit
FCSM (admin-zoning) : user1>
.
.
FCSM (admin-zoning) : user1> zoning cancel
Zoning edit mode will be canceled. Please confirm (y/n): [n] y
FCSM (admin) : user1> admin end
The following is an example of the Zoning List command.
FCSM: user1> zoning list
Active ZoneSet Information
ZoneSet
Zone
ZoneMember
--------------------------------
wwn
wwn_b0241f
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
21:00:00:e0:8b:02:41:2f
wwn_23bd31
wwn_221416
wwn_2215c3
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
10:00:00:00:c9:23:bd:31
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
10:00:00:00:c9:22:14:16
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
10:00:00:00:c9:22:15:c3
Configured Zoning Information
ZoneSet
Zone
ZoneMember
--------------------------------
71
Download from Www.Somanuals.com. All Manuals Search And Download.
wwn
wwn_b0241f
wwn_23bd31
wwn_221416
wwn_2215c3
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
21:00:00:e0:8b:02:41:2f
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
10:00:00:00:c9:23:bd:31
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
10:00:00:00:c9:22:14:16
50:06:04:82:bf:d2:18:c2
50:06:04:82:bf:d2:18:d2
10:00:00:00:c9:22:15:c3
72 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3 Using the SAN Utility
You can use the SAN Utility application to access and configure switch modules. For information about
installing, uninstalling, and starting the SAN Utility application, see the Fibre Channel Switch Module
Installation Guide. The SAN Utility application can be installed on a SBXL52 blade server or an external
network management workstation configured with one of the operating systems described in the Fibre
Channel Switch Installation Guide.
To manage your switch modules and fabrics, the SAN Utility application provides two basic windows:
Topology and Faceplate. The SAN Utility user interface, its elements, and the tasks that you can perform from
the Faceplate window and Topology window are described in this chapter.
Important: Before you configure your switch module, be sure that the management modules in your SBCE
unit are properly configured. In addition, to access and manage your switch module from an external
environment, you might need to enable certain features, such as the external ports and external management
over all ports. See the applicable SBCE Unit Installation and User’s Guide publications on the Resource CD
for more information.
SAN Utility user interface
The Topology window and Faceplate window share the following common elements:
•
•
•
•
•
•
Menu bar
Toolbar
Fabric tree
Graphic window
Data window and tabs
Working Status indicator
The Topology window displays all of the switch modules that are enabled and the connections between switch
modules and other Fibre Channel devices, as shown in Figure 1 on page 74.
73
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 1. Topology window
The Faceplate window displays the front of a single switch module and its active ports, as shown in Figure 2.
Figure 2. Faceplate window
74 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu bar
The menu bar is displayed at the top of the Faceplate window and the Topology window. Depending on which
window is open, the menu bar has similar menu selections. Figure 3 shows menu items that are available in the
Topology window. In the Faceplate window, menu items shown with a gray background are available.
Figure 3. Menu bar selection examples
Some menu selections have shortcut keys as shown in Table 14.
Table 14. Menu shortcut keys
Shortcut key
Menu selection
F5
View ” Refresh
Ctrl+O
File ” Open View File
In addition to the menu bar, both the Topology and Faceplate windows have context-sensitive menus that open
when you click in the graphic window with the right mouse button. See “Opening the Faceplate window and
pop-up menus” on page 82 for more information about these pop-up menus.
75
Download from Www.Somanuals.com. All Manuals Search And Download.
Toolbar
The toolbar consists of a row of graphical buttons that you can use to access SAN Utility functions as shown
and described in Table 15. The toolbar buttons are an alternative method to using the menu bar.
Table 15. Toolbar buttons
Toolbar button
Toolbar button name
Add Fabric
Description
Adds a new fabric
Open View File
Save View As
Refresh
Opens an existing fabric view file
Saves the current fabric view to a file
Polls the fabric to update the Topology or
Faceplate window with the current information
Help Topics
Edit Zoning
Opens the online help
Opens the Edit Zoning window (available only in
the Faceplate window)
76 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Fabric tree
The fabric tree, in the FC Fabric pane, lists the managed fabrics and their switch modules. To adjust the
window, click and drag the moveable window border. An entry handle to the left of an entry in the tree
indicates that you can expand the entry. When you click the handle or double-click the entry, the entry expands
to show its member switches. These fabric tree elements are shown in Figure 4.
Figure 4. Fabric tree
Each fabric tree entry has a small icon next to it that uses color to indicate the following operational status:
•
•
•
A green switch module entry icon indicates that the switch is in normal operation.
A red switch module entry icon indicates that the switch has a communications failure.
A blue switch module entry icon indicates that the switch status is Unknown or that security is enabled on
the switch module but security is disabled on the fabric management switch.
•
An amber switch module entry icon indicates that the switch is operational with errors.
You can use the fabric tree to access any fabric or switch module using the Topology or Faceplate window. You
can click a fabric entry to open the Topology window from the fabric tree. You can click a switch module entry
to open the Faceplate window from the fabric tree.
Graphic window
The graphic window as shown in Figure 1 on page 74 shows graphic information about fabrics and switch
modules such as the fabric topology and the switch faceplate. To adjust the window length, click and drag the
window border that it shares with the data window.
Data window and tabs
The data window as shown in Figure 2 on page 74 displays a table of data and statistics associated with the
selected tab. Use the scroll bar to browse through the data. The window length can be adjusted by clicking and
dragging the border that it shares with the graphic window.
To adjust the column width, move the pointer over the column heading border shared by two columns until a
right/left arrow graphic is displayed. Click and drag the arrow to the desired width. The data window tabs
show options for the types of information that you can display in the data window. These options vary
depending on the display.
77
Download from Www.Somanuals.com. All Manuals Search And Download.
Working status indicator
The working status indicator as shown in Figure 1 on page 74 is in the lower-right corner of the Topology
window and shows when the network management workstation is exchanging information with the fabric. As
conditions change, the fabric forwards this information to the network management workstation where it is
reflected in the various displays.
Using the Topology window
The Topology window shown in Figure 5 on page 78 polls the selected fabric and displays its topology. switch
modules and interswitch links (ISL) are displayed in the graphic window and use color to indicate status. The
following functional elements are displayed in the Topology window when you click on the Data window tabs:
•
•
•
Switch module and link status
Working with switch modules and links
Topology data windows
Figure 5. Topology window
78 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Fibre Channel switch module and link status
The Fibre Channel switch module icon shape and color provide information about the switch and its
operational state. In the Topology window, lines represent links between switch modules. See Table 16 for
Fibre Channel switch module and link status and “Fabric status” on page 86 for more information about other
Topology window icons.
Table 16. Fibre Channel switch module and link status indicators
Switch module icon color
Green
Status
Normal Fibre Channel switch operation
Operational with errors
Amber
Red
Inactive or Fibre Channel switch failure
Unknown Fibre Channel device
Blue
Working with switch modules and links
Switch module and link icons are selectable and moveable and serve as access points for other windows and
menus. You select switch modules and links to display information, modify configurations, or delete them
from the window. The context-sensitive pop-up menus are accessible through the switch module and link
icons.
Click a switch module or link in the graphic window to display its status in the data window. To select multiple
switch modules or links, hold down the Ctrl key while selecting. When no switch modules or links are
selected, information about all switch modules is displayed. To deselect a switch module or link that is
currently selected, click the switch or link.
Different switch module icons will be displayed depending on the different switch vendor products present in
the attached fabric. See Table 17 on page 87 for a list of switch module icons and vendors. Attached switch
modules that are not manageable through the SAN Utility will be displayed as “third-party manageable”
switch icons. The topology configuration in Figure 6 on page 80 shows an example of a switch fabric with
third-party switch modules.
79
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 6. Switch fabric showing third-party manageable switch modules
Arranging switch modules in the window
You can use the following two methods to arrange individual switch module icons:
•
To move an individual switch module icon, click and drag the icon to another location in the graphic
window. Links stretch or contract to remain connected.
•
To arrange all switch module icons in the Topology window, click View ” Layout Topology.
The Toggle Auto Layout check box in the View menu is selected by default so that the SAN Utility can
arrange the icons when you select Layout Topology.
You can save a custom arrangement, or layout, and restore that layout during a SAN Utility session. To create
a custom arrangement, arrange the icons; then, click View ” Remember Layout. To restore the saved layout,
click View, clear the Toggle Auto Layout check box, and click Layout Topology.
Selecting switch modules and links
Selected switch module icons are highlighted in violet. Selected ISLs are highlighted in amber. You can select
switch modules and links by performing the following tasks:
•
•
To select a switch module or a link, click the icon or link.
To select multiple switch modules or links, hold down the Ctrl key and click the switch modules or links
that you want.
•
To select all switch modules or links, right-click in the graphic window background. Click Select All
Switches or click All Links from the pop-up menu.
To cancel a selection, press and hold the Ctrl key, and select the item again. To cancel multiple selections, click
in the graphic window background.
80 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Topology data window tabs
The Topology Data window contains four tabs at the bottom of the window. When you click a tab, the
following information is displayed:
•
Name Server - Click the Name Server tab to display all devices that are logged with the name
server and their location within the current fabric configuration. See “Name Server Data window”
on page 115 for more information about your configuration.
•
Active Zoneset - Click the Active Zoneset tab to display the active zone set for the fabric,
information about this data window. See “Zoning a fabric” on page 88 for information about zone sets
and zones.
•
•
Switch - Click the Switch tab to display the current network and switch module configuration
Link - Click the Link tab to display the current link status for the selected switch modules in the fabric.
Using the Faceplate window
The Faceplate window shown in Figure 7 and described in this section displays the switch module name and
operational state and the port status. The following functional elements are displayed in the Faceplate window
when you click on the Data window tabs:
•
•
•
Port views and status
Working with ports
Faceplate data windows
Figure 7. Faceplate window
81
Download from Www.Somanuals.com. All Manuals Search And Download.
Opening the Faceplate window and pop-up menus
The Faceplate window shows the front of a single switch module and its ports. You can open the Faceplate
window and pop-up menus when you are in the Topology window by performing the following tasks:
•
To open the Faceplate window when viewing the Topology window, click a switch module entry or icon in
the fabric tree, or double-click the switch module graphic.
•
To open the fabric pop-up menu when viewing the Topology window, right-click the graphic window
background. The fabric pop-up menu displays selections to refresh the fabric, select all switch modules,
select all links, or layout topology.
•
To open the switch module pop-up menu when viewing the Topology window, right-click the switch
module icon in the graphic window. The switch pop-up menu displays selections to refresh the switch,
delete the switch from the display, open the Switch Properties window, or open the Network Properties
window.
•
•
To open the link pop-up menu, right-click the link. The Link pop-up menu displays a selection to delete
the link from the display.
To open a Faceplate window pop-up menu, right-click the faceplate graphic in the Graphic window. The
faceplate pop-up menu displays selections to refresh the switch module, select all ports, manage switch,
port, and network properties, extend credits, and run the Port Loopback tests.
Port views and status
Port color and text provides information about the port and its operational state. Green indicates that the port is
active, and gray indicates that the port is inactive. The Faceplate window displays the following views of port
status corresponding to the View menu options in the Faceplate window:
•
•
•
•
Port mode
Port state
Port speed
Port media
See “Monitoring port status” on page 110 for more information about these displays.
Working with ports
Ports are selectable and serve as access points for other windows and menus. You select ports to display
information about them in the data window or to modify them. You cannot use the SAN Utility to select
internal bays and external ports at the same time; you must select either internal bays or external ports.
Context-sensitive pop-up menus and properties windows are accessible through the Faceplate window and port
icons.
Selecting ports
When you select a port, the port is highlighted with a white border. You can select ports in the following ways:
•
•
To select one port, click the port in the Faceplate display.
To select a range of either internal or external consecutive ports, select a port and then press and hold the
shift key and select another port. The application selects both end ports and all ports in between in port
number.
•
•
To select several nonconsecutive ports, hold the Ctrl key while selecting ports.
To select all external ports, right-click anywhere on the switch module faceplate, and select Select All
Ports from the pop-up menu. To select all internal ports, click any blade server and select All
Ports from the pop-up menu.
To cancel a selection, press and hold the Ctrl key and select it again.
82 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Opening pop-up menus
You can manage the switch module and its ports using the following methods:
•
To open the pop-up menu, right-click anywhere in the graphic window. If no ports are selected, port
specific tasks are unavailable in the menu.
•
To select one or more ports and open the Port pop-up menu, right-click a port.
Faceplate data window tabs
The Faceplate Data window contains six tabs at the bottom of the display. When you click a tab, the following
information is displayed:
•
Name Server - Click the Name Server tab to display all devices connected to the switch module that
are logged with the name server.
•
•
•
•
Switch - Click the Switch tab to display the current switch module configuration data.
Port Statistics - Click the Port Stats tab to display the port performance data for the selected port.
Port Information - Click the Port Info tab to display the port detail information for the selected port.
Configured Zonesets - Click the Configured Zonesets tab to display all zone sets, zones, and zone
membership in the zoning database.
•
Alarm Log - Click the Alarm Log tab to display the system error information.
Managing fabrics
This section describes the following four main tasks for managing fabrics:
•
•
•
•
Setting up security
Managing the fabric database
Displaying fabric information
Zoning a fabric
Setting up security
Access to a switch module and permission to configure a switch is managed through user accounts created by
a fabric administrator. A user account consists of an account name, a password, and an authority level. The
authority level determines whether an account can merely monitor the switch module and fabric activity (User
authority), or change switch module configurations (Administrative authority). See “User command” on page
62 for information about administrating user accounts.
Fabric security determines the enforcement of user accounts on a switch module. A fabric administrator can
enable or disable the fabric security on a switch module using the Set Setup System command.
If fabric security is disabled (default), you can use the SAN Utility to log in to a switch module without an
account name and password. The Login name and Password fields in the Add a Fabric window are ignored,
and you are granted Admin authority. If fabric security is enabled, you must enter an account name and
password to log in to a switch module and add the fabric to the workspace. Having successfully added a fabric,
you can perform only those tasks in the SAN Utility that are granted by the authority level for that account. All
switch modules in a fabric should use the same fabric security value. See “Set Setup command” on page 39 for
information about the System keyword and the Security Enable parameter.
✏ NOTE
A switch module supports a combined maximum of 15 active login sessions. This includes SAN
Utility in-band and out-of-band login attempts, Telnet out-of-band login attempts, and SNMP out-of-
band login sessions. Of this 15, there can be a maximum of 10 SAN Utility login attempts included in
the 15 total attempts. Additional logins are refused.
83
Download from Www.Somanuals.com. All Manuals Search And Download.
Managing the fabric database
A fabric database contains the set of fabrics that you have added during a SAN Utility session. Initially, a
Topology window with an empty fabric database opens. This section describes the following fabric database
management tasks:
•
•
•
•
•
•
•
•
Adding a fabric
Removing a fabric
Opening a fabric view file
Saving a fabric view file
Rediscovering a fabric
Adding a new switch module to a fabric
Replacing a failed switch module in a fabric
Deleting switch modules and links
Adding a fabric
Complete the following steps to add a fabric to the database:
1. In the Faceplate window, click Fabric / Add Fabric.
The Add a New Fabric window opens, as shown in Figure 8.
Figure 8. Add a New Fabric window
2. In the Fabric name field, type a fabric name.
3. In the IP address field, type the IP address of the switch module through which to manage the fabric.
4. In the Login name field, type the initial default login ID, USERID. In the Password field, type
the initial default password, PASSW0RD(the sixth character is a zero, not the letter O). The user
ID and password are case sensitive.
✏ NOTE
The password is for the switch module and is stored in the switch firmware. You are not required to
Setup command” on page 39 for information about the Set Setup commands in the Telnet section to
log in, and obtain password and security information.
5. Click Add fabric.
Removing a fabric
Complete the following steps to delete a fabric file from the database:
1. Select a fabric in the fabric tree.
2. In the Faceplate window, click Fabric / Remove Fabric.
84 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Opening a fabric view file
Complete the following steps to open an existing fabric view file:
1. In the Faceplate window, click File / Open View File, or click the Open icon.
If there is a change to the fabric you are using, you are prompted to save the changes to the view file
before opening a different view file.
The Open View window opens.
2. In the Open View window, type the name of the file you want to open.
3. Type a file password if necessary.
4. Click Load View File. If the fabric has changed, you are prompted to save the file before opening the
new view.
Saving a fabric view file
Complete the following steps to save a fabric view file:
1. In the Faceplate window, click File / Save View As or click the Save icon.
The Save View window opens.
2. In the Save View window, type a new file name.
3. Click OK.
4. Type a file password, if necessary.
Rediscovering a fabric
After making changes or deleting switch modules from a fabric view, refresh the fabric configuration. Use the
Rediscover Fabric option to clear the current fabric information that is displayed and rediscover the switch
module information. To rediscover a fabric, in the Faceplate window, click Fabric / Rediscover Fabric.
Adding a new switch module to a fabric
After you install a switch module into your SBCE unit, the switch uses the default fabric configuration
settings. The default fabric configuration settings are as follows:
•
•
•
Fabric zoning is sent to the switch module from the fabric.
All external ports (0,15) are GL_Ports; all internal ports (1 through 14) are F_Ports.
The default IP addresses are:
For switch module bay 3:
192.168.70.129
For switch module bay 4:
192.168.70.130
Complete the following steps to add a new switch module to a fabric and not make changes to the default
fabric configuration settings:
1. If the switch module is not new, to reset the switch to the factory configuration, in the Faceplate window,
click Switch / Restore Factory Defaults.
2. If you want to manage the switch module through the Ethernet port, configure the network SNMP
configuration using the Network Properties window. For more information, see “Network properties” on
3. Configure any special switch settings.
✏ NOTE
To prevent communication with other switch modules in the fabric until the new switch is
configured, in the Zoning Config window, click None in the Default Visibility field. For more
information, see “Zoning configuration” on page 90.
85
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Connect the interswitch links (ISL), but do not connect the devices.
5. In the Port Properties window, configure the port types for the new switch (GL_Port, TL_Port, Donor).
6. Connect the Fibre Channel devices to the switch module.
7. In the Edit Zoning window, make the necessary zoning changes.
Replacing a failed switch module in a fabric
Complete the following steps to replace a failed switch module for which an archive is available. See
“Restoring a switch module” on page 128 and “Archiving a switch module” on page 108 for more information.
1. Remove the failed switch module. For more information, see the Installation Guide.
2. Install the new replacement switch module. For more information, see the Installation Guide.
3. Log in to the fabric through the replacement switch module. In the Topology window, select the
replacement switch module from the fabric tree.
4. Click Switch / Restore.
The Restore Switch window opens.
5. In the Restore Switch window, type a name or select the archived switch configuration file to copy to the
switch module. For more information, see “Archiving a switch module” on page 108.
6. Click OK to write the configuration file to the switch module.
Deleting switch modules and links from the Topology display
The SAN Utility does not automatically delete switch modules or links that have failed or that are physically
removed. In this case, you can delete switch modules and links in the Topology window to bring the display up
to date. If you delete a switch or a link that is still active, the SAN Utility restores it automatically. You can
also refresh the display.
Complete the following steps to delete a switch module in the Topology window:
1. Select one or more switch modules in the Topology window.
2. Click Switch / Delete.
Complete the following steps to delete a link:
1. Select one or more links in the Topology window.
2. Click Switch / Delete.
Displaying fabric information
The Topology window is the primary tool for monitoring a fabric. The graphics window of the Topology
window provides status information for switch modules, interswitch links, and the Ethernet connection to the
network management workstation.
The data window tabs show name server, switch, and active zone set information. The Active Zoneset tab
shows the zone definitions for the active zone set. See “Switch Data window” on page 100 and “Name Server
Data window” on page 115 for information about the Switch Data and Name Server Data windows.
Fabric status
The fabric updates the Topology and Faceplate windows by forwarding changes in status to the network
management workstation as they occur. Use the fabric to update the display status, or you can refresh the
display at any time. To refresh the Topology window, use one of the following methods:
•
•
•
In the Topology window, click Refresh.
Click View / Refresh.
Press the F5 key.
86 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
•
Right-click anywhere in the background of the Topology window. Select Refresh Fabric from the pop-
up menu.
The Topology window displays switch module and status icons that provide status information about switches,
interswitch links, and the Ethernet connection. The switch module icons indicate different vendor switches and
switch types. The switch module status icons, displayed on the left side of a switch, vary in shape and color.
Each switch module that is managed by an Ethernet Internet protocol (IP) has a colored Ethernet icon that is
displayed on the right side of the switch. A green Ethernet icon indicates normal operation, amber indicates
operational with errors, and red indicates inactive or failure. Table 17 on page 87 shows the different switch
module icons and their descriptions.
✏ NOTE
Different switch module icons are displayed depending on the different switch vendor products
presented in the attached fabric. For a list of switch module icons and vendors, see Table 17 Attached
switch modules that are not manageable through the SAN Utility are displayed as third-party
switch fabric with third-party switch modules.
Table 17. Topology window switch module and status icons
Switch module icon
Description
Fibre Channel switch module
QLogic* 8-port Fibre Channel switch module
QLogic16-port Fibre Channel switch module
Inrange switch module
McData switch module
Brocade switch module
Other third-party switch modules
Switch communication normal (green)
Switch is operational with errors (amber)
Switch communication interrupted (red)
Switch management communication unknown (blue)
Fabric management switch Ethernet connection normal (green)
Fabric management switch Ethernet connection critical (red)
Fabric management switch Ethernet connection warning (amber)
87
Download from Www.Somanuals.com. All Manuals Search And Download.
Active Zoneset Data window
The Active Zoneset Data window displays the zone membership for the active zone set that resides on the
fabric management switch. The active zone set is the same on all switch modules in the fabric. You can
confirm this by adding a fabric through another switch module and comparing Active Zone Set displays.
To open the Active Zoneset Data window, click the Active Zoneset tab below the data window in the
Topology window. See “Zoning a fabric” on page 88 for more information about zone sets and zones. See
“Configured Zonesets Data window” on page 102 for information about the zone set definitions on a specific
switch module.
The Active Zoneset data window, shown in Figure 9 on page 88 uses display conventions for expanding and
contracting entries that are similar to the fabric tree. An entry handle to the left of an entry in the fabric tree
indicates that you can expand the entry. Click this handle or double-click the following entries to expand or
contract them:
•
•
•
•
A zone set entry expands to show its member zones.
A zone entry expands to show its member ports.
A port entry expands to show the port Fibre Channel address.
A Fibre Channel address entry expands to show the port worldwide name.
Figure 9. Active Zonesets window
Zoning a fabric
Fibre Channel fabrics use zoning to restrict or extend access to devices in the fabric. A zone is a named group
of devices that can communicate with each other.
You can use zoning to divide the ports and devices of the fabric into zones for more efficient and secure
communication among functionally grouped nodes. You can set the Auto Save and Default Visibility zoning
configuration parameters using the SAN Utility or the Set Config Zoning command. See “Auto save” on page
90 for information about the Auto Save parameter, see “Default visibility” on page 91 for information about
the Default Visibility parameter, and see “Using the Zoning Config window” on page 91 for information about
the Set Config Zoning command.
88 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Zoning concepts
The following zoning concepts provide some context for the zoning tasks described in this section:
Zones
Aliases
•
•
•
•
•
Zone sets
Zoning database
Zoning configuration
Zones
A zone is a named group of ports or devices that can communicate with each other. Membership in a zone is
defined by port number, device Fibre Channel address, or device World Wide Name (WWN). Zone members
can communicate only with members of the same zone. Zones can overlap -- a port or device can be a member
of more than one zone.
Three zone types are supported, but have restrictive levels of communication. These zone types are:
•
•
•
Soft zone
Access control list (ACL) - hard zone
Virtual private fabric (VPF) - hard zone
Soft zoning
Soft zoning divides the fabric to control discovery. Members of the same soft zone automatically discover and
communicate freely with all other members of the same zone. The soft zone boundary is not secure; traffic
across soft zones can occur if addressed correctly. Soft zones that include members from multiple switch
modules need not include the ports of the interswitch links. Soft zone boundaries yield to ACL and VPF zone
boundaries. Soft zones can overlap -- a port can be a member of more than one soft zone. Membership is
defined by Fibre Channel address, port ID and domain ID, or worldwide name. Soft zoning supports all port
modes.
Access control list zones
Access control list (ACL) zoning divides the fabric to control discovery and inbound traffic. ACL zoning is a
type of hard zoning that is hardware enforced. This type of zoning is useful for controlling access to certain
devices without totally isolating them from the fabric. Members can communicate with each other and
transmit outside the ACL zone but cannot receive inbound traffic from outside the zone. The ACL zone
boundary is secure against inbound traffic. ACL zones can overlap -- a port can be a member of more than one
ACL zone. ACL zones that include members from multiple switch modules need not include the ports of the
interswitch links. ACL zone boundaries supersede soft zone boundaries but yield to VPF zone boundaries.
Membership can be defined only by port ID and domain ID. ACL zoning supports all port modes except
TL_Ports.
Virtual private fabric zones
Virtual private fabric (VPF) zoning divides the fabric for purposes of controlling discovery and both inbound
and outbound traffic. This type of zoning is useful for providing security and reserving paths between devices
to guarantee bandwidth. VPF zoning is a type of hard zoning that is hardware enforced. Members can transmit
to and receive only from members of the same VPF zone. The VPF zone boundary is secure against both
inbound and outbound traffic. VPF zones that include members from multiple switch modules must include
the ports of the interswitch links. VPF zones cannot overlap -- a port can be a member of only one VPF zone.
VPF zone boundaries supersede both soft and ACL zone boundaries. Membership can be defined only by port
ID and domain ID. VPF zoning supports all port modes.
✏ NOTE
Domain ID conflicts can result in automatic reassignment of switch module domain IDs. These
reassignments are not reflected in zones that use domain ID and port number pairs or Fibre Channel
addresses to define their membership. Be sure to reconfigure zones that are affected by a domain ID
change. To prevent zoning definitions from becoming invalid when the membership is defined by
domain ID/port number or Fibre Channel address, you must lock domain IDs.
89
Download from Www.Somanuals.com. All Manuals Search And Download.
Aliases
You can create an alias to make it easier to add a group of ports or devices to one or more zones. An alias is a
named set of ports or devices that are grouped together for convenience. Unlike zones, aliases impose no
communication restrictions between its members. You can add an alias to one or more zones. However, you
cannot add a zone to an alias, nor can an alias be a member of another alias.
Zone sets
A zone set is a named group of zones. A zone can be a member of more than one zone set. All zones that are
not members of a zone set belong to the orphan zone set. The orphan zone set is saved to the switch module.
Each switch module in the fabric maintains its own zoning database containing one or more zone sets. This
zoning database resides in nonvolatile or permanent memory and is therefore retained after a reset. For
information about displaying the zoning database, see “Configured Zonesets Data window” on page 102.
To apply zoning to a fabric, select a zone set and activate it. When you activate a zone set, the switch module
distributes that zone set to every switch in the fabric. Therefore, every switch module in the fabric will have
identical active zone sets. For information about displaying the active zone set, see “Active Zoneset Data
Zoning database
Each switch module has its own zoning database. The zoning database is made up of all aliases, zones, and
zone sets that have been created on the switch or received from other switch modules. The switch module
maintains two copies of the zoning database: one copy is maintained in temporary memory for editing
purposes; the second copy is maintained in permanent memory. Zoning database edits are made on an
individual switch basis and are not propagated to other switch modules in the fabric when saved.
The Auto Save zoning configuration parameter controls whether the temporary zoning database is
automatically saved in permanent memory. For more information about the Auto Save parameters, see
“Zoning configuration.”
The zoning limits for a fabric are:
•
•
•
•
•
•
•
Maximum number of zonesets is 256
Maximum number of zones is 256
Maximum number of aliases is 256
Maximum number of members per zone is 2000
Maximum number of members per alias is 2000
Maximum total number of zone and alias members is 2000
Maximum total number of zone set members is 1000
Zoning configuration
You can set the zoning configuration parameters using the SAN Utility or the Set Zoning Config command.
For information about zoning configuration using the SAN Utility, see “Using the Zoning Config window”
The following parameters make up the zoning configuration:
•
Auto Save
•
Default Visibility
Auto save
The Auto Save parameter determines whether changes to the active zone set that a switch module receives
from other switches in the fabric are saved to permanent memory on that switch module. Changes are saved
when an updated zone set is activated. Zoning changes are always saved to temporary memory. However, if
Auto Save is enabled, the switch module firmware saves changes to the active zone set in both temporary and
permanent memory. If Auto Save is disabled, changes to the active zone set are stored only in temporary
memory.
90 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Default visibility
The Default Visibility parameter determines the level of communication that is permitted between devices
when there is no active zone set. The default visibility parameter can be set differently on each switch module.
When default visibility is enabled (set to All) on a switch module, all ports on the switch can communicate
with all ports on switch modules that also have the Default Visibility parameter set to Enabled. When default
visibility is disabled (set to None) on a switch module, none of the ports on that switch module can
communicate with any other switch in the fabric.
Using the Zoning Config window
Use the Zoning Config window to change the Auto Save and Default Visibility configuration parameters.
Complete the following steps to open the Zoning Config window and change configuration parameters:
1. In the Faceplate window, click Zoning ” Edit Zoning Config.The Zoning Config window opens.
Figure 10. Zoning Config window
2. Make the necessary changes to the Auto Save and Default Visibility fields and click OK.
Restoring default zoning
Restoring the default zoning clears the switch module of all zoning definitions. Complete the following steps
to restore the default zoning for a switch module.
Attention: The use of this command will deactivate any active zone set. If the switch module is not isolated
from the fabric, this command will deactivate the active zone set for the entire fabric.
1. In the Faceplate window, click Zoning ” Restore Default Zoning.
2. Click OK to confirm that you want to restore default zoning and save changes to the zoning database.
Merging fabrics and zoning
If you join two fabrics, the active zone sets from the two fabrics attempt to merge. The fabrics can consist of a
single switch module or many switches already connected together. The switch modules in the two fabrics
attempt to create a new active zone set containing the union of the active zone set of each fabric. The
propagation of zoning information affects only the active zone set, not the configured zone sets.
Zone merge failure
If a zone merge is unsuccessful, the interswitch links between the fabrics will isolate because of a zone merge
failure, which generates an alarm log entry. The reason for the E_Port isolation can also be determined by
viewing the port information. See the “Port Information Data window” on page 102 and the “Show command”
on page 42 (Port keyword).
91
Download from Www.Somanuals.com. All Manuals Search And Download.
A zone merge will fail if the two active zone sets have member zones with identical names that differ in
content or type. For example, consider Fabric A and Fabric B, each with a zone in its active zone set named
“ZS1.” Fabric A “ZS1” contains a member specified by Domain ID 1 and Port 1; Fabric B “ZS1” contains a
member specified by Domain ID 1 and Port 2. In this case, the merge fails, and the interswitch links between
the fabrics are isolated.
Zone merge failure recovery
When a zone merge failure occurs, the conflict that caused the failure must be resolved. You can correct a
failure due to a zone conflict by deactivating one of the active zone sets or editing the conflicting zones so that
their membership is the same. You can deactivate the active zone set on one switch module if the active zone
set on the other switch accurately defines your zoning needs. If not, you must edit the zone memberships and
reactivate the zone sets. For information about adding and removing zone members, see “Managing zones” on
page 95. To permit the fabrics to join, reset the ports that were isolated. See “Resetting a port” on page 120.
Using the Edit Zoning window
Use the Edit Zoning window to edit the zoning database for a specific switch module. To edit the zoning
database, in the Faceplate window, click Zone / Edit Zoning. The Edit Zoning window opens.
✏ NOTE
You can make changes only to an active zone set, which is stored in flash (nonvolatile) memory and
retained after setting a switch module.
Figure 11. Edit Zoning window
The Edit Zoning window displays a Zone Sets tree in the left pane and a Port and Device (or members) tree in
the right pane, as shown in Figure 11 Both trees use display conventions similar to the fabric tree for
expanding and contracting zone sets, zones, and ports. An expanded port shows the port Fibre Channel
address; an expanded address shows the port worldwide name. You can select zone sets, zones, and ports in the
following ways:
•
•
•
•
Click a zone, zone set, or port icon.
Right-click to select a zone set or zone and open the corresponding pop-up menu.
Hold down the Shift key while clicking several consecutive icons.
Hold down the Ctrl key while clicking several nonconsecutive icons.
92 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the toolbar, pop-up menus, or a drag-and-drop method, you can create and manage zone sets and zones
in the zoning database. Click Apply to save your changes to the zoning database without closing the window.
Click OK to save your changes to the zoning database and close the window.
The following table explains the toolbar buttons and functions.
Table 18. Edit Zoning window toolbar buttons
Toolbar button
Function
Create a new zone set.
Create a new zone.
Create an additional name for a set of objects.
Add the selected zone to a zone set, or add the selected port to a zone.
Delete the selected zone from a zone set, or delete the selected port from a
zone.
Managing zone sets
Zoning a fabric involves creating a zone set, creating zones as zone set members, then adding devices as zone
members. The zoning database supports multiple zone sets to serve the different security and access needs of
your storage area network. Only one zone set can be active at one time. Managing zone sets involves the
following tasks:
•
•
•
•
•
•
Creating zone sets
Activating and deactivating zone sets
Copying a zone to a zone set
Removing a zone from one zone set or from all zone sets
Removing a zone set
Removing all zoning definitions
✏ NOTE
Changes that you make to the zoning database are limited to the managed switch module and do not
propagate to the rest of the fabric. To distribute changes to configured zone sets fabric-wide, you must
edit the zoning databases on the individual switch modules.
93
Download from Www.Somanuals.com. All Manuals Search And Download.
Creating a zone set
Complete the following steps to create a zone set:
1. In the Faceplate window, click Zoning / Edit Zoning. The Edit Zoning window opens.
2. Click Edit / Create Zone Set. The Create Zone Set window opens.
3. Type a name for the zone set, and click OK. The new zone set name is displayed in the Zone Sets
window.
4. Complete one of the following tasks to create new zones in a zone set:
•
Right-click a zone set and select Create A Zone from the pop-up menu. In the Create A Zone
window, type a name for the new zone, and click OK. The new zone name is displayed in the
Zone Sets window.
•
To copy an existing zone into the new zone set, in the Faceplate window, select the zone and drag it
into the new zone set.
5. Click Apply to save changes to the zoning database.
Activating and deactivating a zone set
You must activate a zone set to apply its zoning definitions to the fabric. Only one zone set can be active at one
time. When you activate a zone set, the switch module distributes that zone set to the temporary zoning
database on every switch in the fabric, replacing any zone set of the same name. If Auto Save is enabled, the
zone set is saved in the permanent zoning database also. For more information, see “Auto save” on page 90.
The purpose of the deactivate function is to suspend all fabric zoning, which results in free communication
fabric-wide or no communication, depending on the default visibility setting. For more information, see
“Default visibility” on page 91. It is not necessary to deactivate the active zone set before activating a new one.
Complete the following steps to activate a zone set:
1. In the Faceplate window, click Zoning / Activate Zone Set. The Activate Zoneset window opens.
2. In the Select Zone Set menu, click Zone Set / Activate.
Complete the following steps to deactivate a zone set:
1. In the Faceplate window, click Zoning / Deactivate Zone Set. A message warning you about traffic
disruption is displayed.
2. Click Yes to confirm that you want to deactivate the active zone.
Copying a zone to a zone set
Complete the following steps to copy an existing zone and its membership from one zone set to another:
1. In the Faceplate window, select the zone and drag it to the zone set you want.
2. Click Apply to save your changes to the zoning database.
Removing a zone from a zone set or from all zone sets
Complete the following steps to remove a zone from a zone set or from all zone sets in the database:
1. In the Faceplate window, click Zoning / Edit Zoning. The Edit Zoning window opens.
2. In the Zone Sets tree, select the zone you want to remove.
3. Click Edit / Remove to remove the zone from the zone set, or select Remove from All Zones to
remove the zone from all zone sets.
4. Click Apply to save changes to the zoning database.
✏ NOTE
You can use shortcut menus to remove a zone from a zone set or from all zone sets in the database.
94 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing a zone set
Removing a zone set from the database affects the member zones in the following ways:
•
•
Member zones that are members of other zone sets are not affected.
Member zones that are not members of other zone sets become members of the orphan zone set. The
orphan zone set is saved on the switch module.
Complete the following steps to remove a zone set from the database:
1. In the Faceplate window, click Zoning / Edit Zoning. The Edit Zoning window opens.
2. In the Zone Sets tree, select the zone set to be removed.
3. Click Edit / Remove to remove the zone set.
4. Click Apply to save changes to the zoning database.
✏ NOTE
You can use shortcut menus to remove a zone set from the database.
Removing all zoning definitions
To remove all zone and zone set definitions from the zoning database, use one of the following methods:
•
Click Edit / Remove All. In the Remove All window, click Yes to confirm that you want to delete all
zones and zone sets.
•
Right-click the Zone Sets heading at the top of the Zone Sets tree, and select Clear Zoning from
the pop-up menu. Click Yes to confirm that you want to delete all zone sets and zones.
Managing zones
Managing zones involves the following tasks:
•
•
•
•
•
•
•
Creating a zone in a zone set
Adding zone members
Renaming a zone or a zone set
Removing a zone member
Removing a zone from a zone set
Removing a zone from all zone sets
Changing zone types
✏ NOTE
Changes to the zoning database are limited to the managed switch module and do not propagate to the
rest of the fabric. To distribute changes to configured zone sets fabric-wide, you must edit the zoning
databases on the individual switch modules.
Creating a zone in a zone set
When a zone is created, its zone type is soft. To change the zone type to a hard zone, see “Changing zone
types” on page 97 for more information. See “Zones” on page 89 for information on soft and hard zone types.
Complete the following steps to create a zone in a zone set:
1. In the Faceplate window, click Zoning / Edit Zoning. The Edit Zoning window opens.
2. Click Edit / Create a Zone. The Create a Zone window opens.
3. Type a name for the new zone and click OK. The new zone name is displayed in the Zone Sets
window.
✏ NOTE
If you type the name of a zone that already exists in the database, the SAN Utility will create a copy
of that zone and its membership in the zone set.
95
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Use one of the following methods to add ports or devices to the zone:
•
•
•
In the zone set tree, select the zone set. In the graphic window, select the port to add to the zone. Click
Edit / Add Members.
Select a port by port number, Fibre Channel address, or worldwide name in the Port or Device tree,
and drag it into the zone.
Select a port by port number, Fibre Channel address, or worldwide name in the Port and Device tree.
Right-click the zone and select Add Zone Members from the pop-up menu.
5. Click Apply to save your changes to the zoning database.
Adding zone members
Adding a zone member to a zone affects every zone set in which that zone is a member. To add member ports
and devices to a zone, choose one of the following methods:
•
Select a port by port number, Fibre Channel address, or worldwide name in the Port and Device tree, and
drag it into the zone. To select and drag multiple ports and devices, press and hold the Ctrl key while
dragging.
•
Select one or more ports by port number, Fibre Channel address, or worldwide name in the Port and
Device tree. Right-click the zone and select Add Zone Members from the pop-up menu.
Click Apply to save your changes to the zoning database.
✏ NOTE
Domain ID conflicts can result in automatic reassignment of switch module domain IDs. These
reassignments are not reflected in zones that use domain ID and port number pair to define their
membership. Be sure to reconfigure zones that are affected by a domain ID change.
Renaming a zone or a zone set
Complete the following steps to rename a zone:
1. In the Edit Zoning window, in the Zone Sets tree, click the zone or zone set to be renamed.
2. Click Edit / Rename.
3. In the Rename Zone/Rename Zone Set window, type a new name for the zone and zone set.
4. Click OK.
Removing a zone member
Removing a zone member will affect every zone and zone set in which that zone is a member. Complete the
following steps to remove a member from a zone:
1. In the Edit Zoning window, select the zone member to be removed.
2. Click Edit / Remove.
3. Click OK to save the changes and close the Edit Zoning window.
Removing a zone from a zone set
Removing a zone from a zone set will affect every zone set in which that zone is a member. Zones that are no
longer members of any zone set are moved to the orphan zone set. The orphan zone set is saved on the switch
module.
Complete the following steps to delete a zone from a zone set:
1. In the Edit Zoning window, select the zone to be removed.
2. Click Edit / Remove.
3. Click OK to save the changes and close the Edit Zoning window.
96 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing a zone from all zone sets
Complete the following steps to delete a zone from all zone sets:
1. In the Edit Zoning window, select the zone to be removed
2. Click Edit / Remove Zone from All Sets.
3. Click OK to save the changes and close the Edit Zoning window.
Changing zone types
Zones that are no longer members of any zone set are moved to the orphan zone set. The orphan zone set is
saved on the switch module.
Complete the following steps to change a zone type:
1. In the Faceplate window, select the switch module with the zone type you want to change.
2. Click Zoning / Edit Zoning or click the Zoning icon to open the Edit Zoning window.
3. In the Zone Sets tree, select the zone to change.
4. Click Edit / Set Zone Type.
The Set Zone Type window opens.
5. Click Zone Type / Soft, ACL (hard zoning), or VPF (hard zoning).
•
•
Soft zoning is the least restrictive type of zoning.
ACL zoning is hard zoning and is enforced by hardware and defines access to a given port. ACL
zones need not include interswitch links.
•
VPF zoning is hard zoning that defines ports that can communicate with each other. VPF zones must
include interswitch links.
For more information about zone types, see “Zones” on page 89.
Managing aliases
An alias is a named set of ports or devices that are grouped together for convenience. An alias is not a zone and
cannot have a zone or another alias as a member. This section describes how to create, remove, and add a
member to an alias.
✏ NOTE
Changes that you make to the zoning database are limited to the managed switch module and do not
propagate to the rest of the fabric. To distribute changes to configured zone sets fabric wide, you must
edit the zoning databases on the individual switch modules.
Creating an alias
Complete the following steps to create an alias:
1. In the Faceplate window, click Zoning / Edit Zoning. The Edit Zoning window opens.
2. Click Edit / Create Alias. The Create Alias window opens.
3. Type a name for the alias and click OK. The alias name is displayed in the Zone Sets window.
4. Click OK to save the alias name to the zoning database.
97
Download from Www.Somanuals.com. All Manuals Search And Download.
Adding a member to an alias
To add a member to an alias, use one of the following methods:
•
•
Drag-and-drop method
Menu options
Complete the following steps to add a member to an alias using the drag-and-drop method:
1. In the right pane of the Faceplate window, click and hold down the mouse button on the member to be
added to the alias.
2. Drag the selected member from the right pane to the alias in the left pane.
Complete the following steps to add a member to an alias using the menu options:
1. Click Zoning / Edit Zoning.
The Edit Zoning window opens.
2. In the left pane of the Edit Zoning window, select an alias.
3. In the right pane, select the member to add to the selected alias.
4. Use one of the following actions:
•
•
Click Edit / Add Members.
Click Insert.
5. Click OK to save the changes and close the Edit Zoning window.
Removing an alias from all zones
Complete the following steps to remove an alias from all zones:
1. In the Zone Sets tree of the Edit Zoning window, select the alias to be removed.
2. Click Edit / Remove Alias from All Zones.
3. In the Remove window, click Yes.
Managing switch modules
This section describes the following tasks that manage switch modules in the fabric.
•
•
•
•
•
•
•
•
•
Displaying switch module information
Managing alarms
Exporting name server information to a file
Paging a switch module
Setting the switch module date and time
Resetting a switch module
Configuring a switch module
Archiving a switch module
Managing firmware
98 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Displaying switch module information
The Faceplate window and data windows provide the following specific switch module information:
•
•
•
•
•
•
Name server information
Switch module specifications and addresses
Configuration parameters
Performance statistics
Configured zone sets
Alarm log information
Figure 12. Faceplate data window
A fabric updates the Topology and Faceplate windows by forwarding changes in status to the network
management workstation as they occur. You can use the fabric to update the switch module status, or you can
refresh the switch status at any time. To refresh a switch module status that is displayed, use one of the
following actions:
•
•
•
•
•
Click Refresh.
Click View ” Refresh.
Press the F5 key.
Right-click a switch module in the Topology window and click Refresh Switch.
Right-click in the graphic window in the Faceplate window, and click Refresh Switch.
Name Server data window
The Name Server data window displays information about the devices that are logged in to the fabric. Click
the Name Server tab below the data window to display name server information for all devices that are logged
in to the selected fabric. To narrow the display to devices that are logged in to specific switch modules, select
one or more switches in the fabric tree or the Topology window. For a description of the entries in the Name
Server Data window, see Table 19 on page 100 For exporting name server information, see “Exporting alarm
✏ NOTE
Internal ports 1 through 14 are fixed.
99
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 19. Name server data window entries
Entry
Description
Device
Device number in the fabric
Switch module name
Switch
Port
Port number: Ext1:0, Ext2:15
Fibre Channel address
Address
Type
Node type
NWWN
PWWN
Vendor
FC-4 types
Active zones
Node worldwide name
Port worldwide name
Host bus adapter and device vendor
Device Fibre Channel protocol types
Zones in the current active zone set that contains the device
Switch Data window
The Switch Data window displays current network and switch module information for the selected switches.
For more information about the Switch data window, see “Configuring a switch module” on page 105. To open
the Switch Data window, select one or more switch modules in the Topology window and click the Switch tab
below the window. You can also open the Switch Data window from the Faceplate window.
Table 20. Switch data window entries
Entry
Description
Switch module Fibre Channel address
FcAddress
World Wide name
Reason for status
User name
Switch module worldwide name
Additional status information
Name of user
Login level
Security level
Security enabled
Fabric security on the switch module that enforces account names and
passwords
Vendor
Switch module manufacturer
Active flash
Flash version
Inactive flash version
PROM/Flasher version
MAC address
IP address
Inactive firmware version
Firmware version
Media access control address
Internet protocol address
Mask that determines the IP address subnet
Gateway address
Subnet mask
Gateway
Negotiated domain ID
The domain ID currently in use by the fabric
100 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 20. Switch data window entries (continued)
Entry
Description
Configured domain ID
Domain ID lock
The domain ID defined by the network administrator
Domain ID lock status. Prevents (True) or permits (False) dynamic domain ID
reassignment
Number of ports
Switch type
Number of ports on the switch module
Fibre Channel switch module model
Operational state
Administrative state
Configured Admin State
MFS timeout
Switch module operational state: Online, offline, and diagnostic
Current switch module administrative state: Online, offline, and diagnostic
Switch module administrative state that is stored in the switch configuration
Multiframe sequencing timeout value
RA timeout
Resource allocation timeout value
RT timeout
Receiver transmitter timeout value
ED timeout
Error detect timeout value
Zoning merge mode
Zoning merge auto save
Active zone set merge or all zone set merge
Zoning auto save status. Saves zoning updates in temporary and permanent
memory (True) or only in temporary memory (False).
Zoning default visibility
Zoning visibility status. Permits (ALL) or prevents (None) communication with
other switch modules in the absence of an active zone set.
Temperature
Not applicable
Fan 1 status
Not applicable
Fan 2 status
Not applicable
Fan 3 status
Not applicable
Power supply 1 status
Power supply 2 status
Beacon status
Broadcast support
Inband enabled
Not applicable
Not applicable
Beacon status. Port Logged-in LEDs are flashing (On) or not (Off).
Broadcast support status. Broadcast support is enabled or disabled (default).
Inband management status. Permits (True) or prevents (False) a switch
module from being managed over an ISL.
Switch date
Switch module time and date
Link data window
The Link data window displays information about all switch module links in the fabric or selected links. This
information includes the switch module name and port number at the end of each link. To open the Link data
window, click the Link tab below the window.
101
Download from Www.Somanuals.com. All Manuals Search And Download.
Fabric view port graphing application
You can use the Fabric View application to view port performance as graphs. The Fabric View window
displays data communication rates and total errors for selected ports as shown in Figure 23 on page 129 You
can graph communication data rates in frames per second or KB per second. See “Using the Fabric View
application” on page 128 for information about tasks that can be performed when using the Fabric View
application.
Port Statistics Data window
The Port Statistics Data window displays port performance data for the selected ports. To open the Port
Statistics Data window, click the Port Stats tab below the data window in the Faceplate window. For a
description of the Port Statistics Data window entries, see Table 28 on page 112
The Statistics menu is accessible in the Port Statistics Data window, and provides different ways to view
detailed port information. Click the down arrow to open the Statistics menu. In the Statistics menu, you can:
•
•
•
•
Click Absolute to view the total count of statistics since the last switch module reset.
Click Rate to view the number of statistics counted per second over the polling period.
Click Baseline to view the total count of statistics since the last time the baseline was set.
Click Clear Baseline to set the current baseline.
Port Information Data window
The Port Information Data window displays port detail information for the selected ports. To open the Port
Information Data window, click the Port Info tab below the data window in the Faceplate window. For a
description of the Port Information Data window entries, see Table 29 on page 114
Configured Zonesets Data window
The Configured Zonesets Data window displays all zone sets, zones, and zone membership in the zoning
database. To open the Configured Zonesets Data window, click the Configured Zonesets tab below the data
window in the Faceplate window shown in Figure 13 on page 102
Figure 13. Zonesets Data window
102 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
The Configured Zonesets Data window uses display conventions for expanding and contracting entries that are
similar to the fabric tree. An entry handle to the left of an entry in the tree indicates that you can expand the
entry. Click this handle or double-click the following entries to expand or contract them:
•
•
A zone set entry expands to show its member zones.
A zone entry expands to show its members by port number, worldwide name, or Fibre Channel address.
Alarm Log Data window
The Alarm Log Data window displays switch module event information. To open the Alarm Log Data
window, click the Alarm Log tab below the data window in the Faceplate window.
Managing alarms
You can configure the switch module to generate and log alarms. To display the Alarm Log, click the Alarm
Log tab in the Faceplate window. For information about the alarm log, see “Alarm Log Data window.” You can
also export the alarm log to a file in XML format.
Configuring alarms
Configuring an alarm involves choosing an event type, rising and falling thresholds, a sampling interval, and
then enabling or disabling the alarm.
Complete the following steps to configure an alarm:
1. In the Faceplate window, click Switch ” Configure Alarm Thresholds.
2. The Alarm Threshold Configuration window shown in Figure 14 on page 103 prompts you to
select an event, set thresholds, set a sampling interval, and enable or disable the alarm.
Figure 14. Alarm Threshold Configuration window
3. Select an event type from the Alarm Threshold pull-down menu. Choose from the following
options:
•
•
•
•
•
•
CRC error monitoring
Decode error monitoring
ISL monitoring
Login monitoring
Logout monitoring
Loss of signal monitoring
4. Enter a value in the Falling Threshold field. The falling threshold is the event count above which an
event becomes eligible for logging in the alarm log.
103
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Enter a value in the Rising Threshold field. The rising threshold is the event count above which an
event is logged. After the count exceeds the rising threshold, one alarm is logged. The switch module will
not generate another alarm for that event until the count falls below the falling threshold and rises again
above the rising threshold.
6. Enter a sample interval, in milliseconds. The sample interval defines the period of time in which to count
events.
7. Select the Enable check box to make the alarm eligible for use.
8. Repeat step 3 through step 7 for each alarm you want to configure or enable.
9. Select the Enable Alarm Threshold Generation check box to activate all alarms enabled in step 7.
10. Click OK to save all changes.
Exporting alarm log information to a file
Complete the following steps to save the switch module alarm log to a file:
1. In the Faceplate window, click Switch / Export Alarm Log.
2. Type a file name in the Save window.
3. Click Save.
Exporting name server information to a file
Complete the following steps to save switch module name server information to a file:
1. In the Topology window, click Switch / Export Name Server.
2. Type a file name in the Save window.
3. Click Save.
Paging a switch module
You can use the beacon feature to page a switch module. The beacon feature causes both external port Logged-
in LEDs to flash, making it easier to locate the switch module you are paging. To page a switch, in the
Faceplate window, click Switch / Toggle Beacon. To cancel the beacon, click Toggle Beacon.
Setting the date and time
Complete the following steps to set the date and time on a switch module:
1. Select a switch in the Topology window and open the Faceplate window.
2. In the Faceplate window, click Switch / Set Date/Time
3. Type the year, month, day and time in the Switch Date and Time window, and then click OK.
The system prompts you to reset the switch module to implement the new date and time.
Resetting a switch module
Resetting a switch module restarts the switch using configuration parameters in memory. You can reset a
switch module using the following methods:
•
•
Select the switch module to be reset in the fabric tree. Click Switch / Reset Switch.
Remove and then reinsert the Fibre Channel switch module in the SBCE unit.
104 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring a switch module
The SAN Utility is used to configure the switch module. Switch module configuration is divided into two
areas: chassis configuration and network configuration. Chassis configuration specifies parameters that relate
to switch module identity on the Fibre Channel network. Network configuration specifies parameters that
relate to switch module identity on the Ethernet network. To open the Switch Properties window, click Switch
/ Switch Properties. You can also right-click a switch graphic in the Topology window or Faceplate window
and click Switch Properties.
Switch module properties
Use the Switch Properties window to change the module name, administrative state and domain ID; to enable
or disable broadcast support; and to enable or disable inband management. See Figure 15. The timeout values
are displayed for reference purposes only when the switch module is online. These fields become active when
the switch module is offline. After making changes, click OK to put the new values into effect.
Figure 15. Switch Properties window
Symbolic name
The symbolic name is a user-defined name that identifies the switch module.
Switch module administrative state
The switch module administrative state determines the operational state of the switch and its ports. The switch
module administrative state exists in two forms: the configured administrative state and the current
administrative state. The configured administrative state is the state that is saved in the switch configuration
and is preserved across switch resets. The SAN Utility always makes changes to the configured administrative
state. The current administrative state is the state that is applied to the switch module for temporary purposes
and is not retained across switch resets. The current administrative state is set using the Set Switch command.
For more information about the Set Switch command, see “Set command” on page 27.
Table 21. Switch module administrative states
Parameter
Description
Online
Offline
Test
The switch module is available.
The switch module is unavailable.
The switch module is in diagnostics mode and is unavailable.
105
Download from Www.Somanuals.com. All Manuals Search And Download.
Domain ID and Domain ID Lock
The domain ID is a unique Fibre Channel identifier for the switch module. The Fibre Channel address consists
of the domain ID, port ID, and the Arbitrated Loop Physical Address (ALPA). The maximum number of
switch modules within a fabric is 239, with each switch having a unique domain ID.
Switch modules come from the factory with the domain IDs unlocked. This means that if there is a domain ID
conflict in the fabric, the switch module with the highest principal priority, or the principal switch, will
reassign any domain ID conflicts and establish the fabric. If you lock the domain ID on a switch module and a
domain ID conflict occurs, the switch module with the higher WWN will be isolated as a separate fabric, and
the Logged-in LEDs on both switch modules will flash to show the affected ports. See “Set Config command”
on page 29 for information about the switch module keyword and the Domain ID Lock and Principal Priority
parameters.
If you connect a new switch module to an existing fabric with its domain ID unlocked and a domain conflict
occurs, the new switch module will be isolated as a separate fabric. However, you can remedy this by resetting
the new switch module or taking it offline then back online. The principal switch module will reassign the
domain ID, and the switch will join the fabric.
✏ NOTE
Domain ID reassignment is not reflected in zoning that is defined by domain ID and port number pair.
You must reconfigure zones that are affected by domain ID reassignment.
Broadcast support
Broadcast is supported by the switch module, which enables TCP/IP support. Broadcast is implemented using
the proposed standard specified in Multi-Switch Broadcast for FC-SW-3, T11 Presentation Number T11/02-
031v0. The FSPF is used to set up a fabric spanning tree used in transmission of broadcast frames. Broadcast
frames are retransmitted on all ISLs indicated in the spanning tree and all online F/FL_Ports. Broadcast zoning
is supported with ACL and VPF hard zones. When a broadcast frame is received, these hard zones are
enforced at the F/FL_Port. If the originator of the broadcast is in a hard zone, the frame is retransmitted on all
online F/FL_Ports within the hard zone. If the originator of the broadcast frame is not in a hard zone, the frame
is retransmitted on online F/FL_Ports that are not in a hard zone.
In-band management
In-band management is the ability to manage switch modules across interswitch links. If you disable in-band
management on a particular switch module, you can no longer communicate with that switch module by
means other than a direct Ethernet or serial connection.
106 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Timeout values
The switch module timeout values determine the timeout values for all external ports on the switch. Table 22
describes the switch module timeout parameters. R_A_TOV, R_T_TOV, or E_D_TOV values must be the
same for all switch modules in the fabric.
✏ NOTE
Timeout values can be changed only if the switch module operational state is offline.
Table 22. Timeout values
Parameter
Description
R_A_TOV
R_T_TOV
E_D_TOV
Resource Allocation Timeout. Represents the maximum time a frame can be delayed in the
fabric and still be delivered. The default is 10000 milliseconds.
Receiver Transmitter Timeout. The amount of time that Sync can be lost between two ports
before Link Failure is detected. The default is 100 milliseconds.
Error Detect Timeout. Represents the maximum round trip time that an operation between two
N_Ports requires. The default is 2000 milliseconds.
Network properties
Use the Network Properties window shown in Figure 16 on page 107 to change IP and SNMP configuration
parameters. After making changes, click OK to put the new values into effect. To open the Network Properties
window, click Switch ” Network Properties.
✏ NOTE
The Read Community, Trap Community, and Write Community settings are like passwords;
therefore, they are write-only fields. The current settings are not displayed.
Figure 16. Network Properties window
107
Download from Www.Somanuals.com. All Manuals Search And Download.
IP configuration
The IP configuration identifies the switch module on the Ethernet network and determines which start (boot)
method to use. Start methods described in the following table are for external and internal ports. Table 23
describes the IP configuration parameters.
Table 23. IP configuration parameters
Parameter
IP address
Description
Internet protocol (IP) address for the Ethernet port.
✏ NOTE
When the SBCE unit is turned on, the management module loads the
following factory default Ethernet IP addresses:
•
•
Switch module bay 3: 192.168.70.129
Switch module bay 4: 192.168.70.130
Subnet mask
Boot method
Gateway
Subnet mask address for the Ethernet port. The default value is 255.255.255.0.
Static - Uses the IP configuration parameters entered in the Switch Properties window.
IP gateway address. The default value is 10.90.90.254.
Remote logging
The Remote Logging (syslog) feature enables saving of the log information to a remote host that supports the
syslog protocol. When enabled, the log entries are sent to the syslog host at the IP address that you specify in
the Logging Host IP Address field. Log entries are saved in the internal switch module log whether this
feature is enabled or not.
To save log information to a remote host, you must edit the syslog.conf file and then restart the syslog daemon.
The syslog.conf file on the remote host must contain an entry that specifies the name of the log file in which to
save error messages. Add the following line to the syslog.conf file:
local0.info <tab> /var/adm/messages.name
Use <tab>to separate the selector field (local0.info) and action field, which contains the log file path name
(/var/adm/messages/messages.name).
Archiving a switch module
You can create an XML archive file containing the switch module configuration parameters. Archived
parameters include the following:
•
•
•
•
•
Switch module properties and statistics
IP configuration
SNMP configuration
Port properties and statistics
Zoning configuration
You can use this archive file to restore the configuration on the same switch module or on a replacement
switch. You can also use the archive file as a template for configuring new switch modules to add to a fabric.
Security settings and user account information are not archived. You can use the archive later to restore the
switch module. For more information, see “Restoring a switch module” on page 128
108 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Complete the following steps to archive a switch module configuration:
1. In the Faceplate window, click Switch ” Archive.
2. In the Save window, type a file name.
3. Click Save.
Managing firmware
The switch module memory is partitioned for two firmware images. This is useful when you are upgrading
firmware so that both the old and new firmware are maintained on the switch module. When you load new
firmware, the currently active firmware is preserved and the new firmware becomes the second image or the
fallback version. You can activate either firmware image. If you activate the fallback firmware, the current
firmware becomes the fallback version.
Loading firmware
The switch module does not have to be offline for you to download firmware. However, the switch module
must be reset to activate the new firmware, which requires administrative authority. The SAN Utility prompts
you to reset the switch module after the firmware is loaded.
Complete the following steps to load firmware to a switch module:
1. In the Faceplate window, click Switch / Load Firmware.
The Firmware Upload window opens.
2. In the Firmware Upload window, click Select to browse and
select the firmware file to be uploaded.
3. Click Start to begin the firmware install process.
4. When the installation is complete, click Close. The
Firmware Upload window closes.
5. The SAN Utility prompts you to reset the switch module. Click OK to reset the switch and activate the
new firmware.
Activating the fallback firmware
Complete the following steps to activate the fallback firmware:
1. In the Faceplate window, click Switch / Firmware Fallback.
2. The Firmware Fallback window displays the file name of the current firmware and the fallback firmware
versions. Click Yes to select the fallback firmware or No to cancel.
3. The SAN Utility prompts you to reset the switch module. Click OK to reset the switch and activate the
new fallback firmware.
Managing ports
This section describes the following tasks that manage ports and devices:
•
•
Displaying port information
Configuring ports
109
Download from Www.Somanuals.com. All Manuals Search And Download.
Displaying port information
Port information is available primarily in the Faceplate window shown in Figure 17 Faceplate Display Data
windows provide information and statistics for switch modules and ports. Use the Topology window to show
the status information for links between switch modules.
Figure 17. Faceplate Display Data window
Monitoring port status
The Faceplate window provides the following port related information:
•
information.)
•
•
•
•
Port mode
Port operational state
Port speed
Port media
To display port number and status information for a port, position the cursor over a port displayed in the
Faceplate window. The status information changes, depending on the View menu option that you select.
Displaying port modes
To display port mode status, from the Faceplate window, click View / View Port Modes. Table 24 lists the
available port modes and their descriptions.
Table 24. Port mode descriptions
Mode
Description
F
Fabric port
FL
TL
G
Fabric loop port
Translated loop port
Generic port
110 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 24. Port mode descriptions (continued)
Mode
Description
GL
E
Generic fabric loop port
Expansion port
Donor port
D
Displaying port operational states
To display the operational state of each port, in the Faceplate window, click View / View Port States. Table 25
lists and describes the available operational states. The port operational state refers to the actual port state and
not the administrative state you might assign.
Table 25. Port operational states
State
Description
On
la
Online - The port is active and ready to send data.
Inactive - The port operational state is Offline, but the administrative state is
Online.
Off
Offline - The port is active and can receive a signal but cannot accept a device
login.
Tst
Dn
Diagnostics - The port is in Diagnostics mode in preparation for testing.
Down – The port is inactive or disabled; it is not receiving a signal and cannot be
logged in to.
Displaying port speeds
To display the speed of each port in the Faceplate window, click View / View Port Speeds. Table 26 lists the
available speeds.
Table 26. Port speeds
State
Description
1 Gbps (gigabits per second) transmission speed
2 Gbps transmission speed
1 Gb
2 Gb
111
Download from Www.Somanuals.com. All Manuals Search And Download.
Displaying SFP module media status
To display SFP module media status, click View / View Port Media. Table 27 lists and describes the available
media states.
Table 27. SFP module media view
Media icon
Description
The SFP module is online (green)
The SFP module is offline (gray)
None
The port is empty; no SFP module is detected or installed
Port graphing and Fabric View application
You can use the Fabric View application to view port performance as graphs. The Fabric View window
displays data communication rates and total errors for selected ports as shown in Figure 23 on page 129. You
can graph communication data rates using either frames per second or KB per second. For more information
about port graphing, see “Using the Fabric View application” on page 128.
Port Statistics Data window
The Port Statistics Data window displays statistics about port performance. To open the Port Statistics Data
window, select one or more ports in the Faceplate window and click the Port Stats tab in the data pane of the
Faceplate window. Table 28 describes the Port Statistics Data window entries. See Table 37 on page 131 for
information about port numbering and mapping.
The Statistics menu is available on the Port Statistics Data window. Click the down arrow to open the Statistics
menu and then use one of the following methods to view the detailed port information:
•
•
•
Click Absolute to view the total count of statistics since the last switch module reset.
Click Rate to view the number of statistics counted per second over the polling period.
Click Baseline to view the total count of statistics since the last time the baseline was set.
When viewing baseline statistics, click Clear Baseline to set the current baseline.
Table 28. Port Statistics Data window entries
Entry
Description
Start time
The beginning of the period of time for which the statistics apply. The start time
for the Absolute view is not applicable. The start time for the Rate view is the
beginning of the polling interval. The start time for the Baseline view is the last
time the baseline was set.
End time
Total time
The last time the statistics were updated on the display.
Total time period from start time to end time.
Login count
Logout count
AI init count
Number of logins that have occurred on the switch module.
Number of logouts that have occurred on the switch module.
Number of times the port entered the initialization state.
Number of address identifiers (S_ID, D_ID) found to be in error.
Invalid destination
address
112 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 28. Port Statistics Data window entries (continued)
Entry
Description
Total LIP received
LIP F7F7 count
Number of loop initialization primitive frames received.
A loop initialization primitive frame used to acquire an Arbitrated Loop Physical
Address (AL_PA).
LIP F8F7 count
Currently not used.
LIP F7AIPs count
This LIP is used to reinitialize the loop. An L_Port, identified by AL_PS, might
have noticed a performance degradation and is trying to restore the loop.
LIP F8AIPs Count
LIP AIPdAIPs Count
Class 2 In Frames
Class 2 Out Frames
Class 2 Words In
Class 2 Words Out
Class 3 In Frames
Class 3 Out Frames
Class 3 Words In
Class 3 Words Out
Decode Error Count
This LIP denotes a loop failure detected by the L_Port identified by AL_PS.
Number of F7, AL_PS LIPs, or AL_PD (vendor specific) resets, performed.
Number of class 2 frames received by this port.
Number of class 2 frames transmitted by this port.
Number of class 2 words received by this port.
Number of class 2 words transmitted by this port.
Number of class 3 frames received by this port.
Number of class 3 frames transmitted by this port.
Number of class 3 words received by this port.
Number of class 3 words transmitted by this port.
Number of invalid transmission words detected during decoding. Decoding is
from the 10-bit characters and special K characters.
Loss Of Sync Count
Number of synchronization losses (>100 ms) detected by this port. A loss of
synchronization is detected by receipt of an invalid transmission word.
Invalid CRC Count
Tx Wait Count
Number of invalid CRC frames detected.
Number of times the port entered a wait state because it was out of buffer-to-
buffer credits.
Class 3 Toss Count
Number of class 2 and class 3 sequences that were discarded by this port. A
sequence can be discarded because of detection of a missing frame (based on
SEQ_CNT), detection of an E_D_TOV timeout, receiving a reject frame,
receiving frames for a stopped sequence, or other causes.
FReject Count
FBusy Count
Number of frames, from devices, that have been rejected. Frames can be
rejected for many reasons.
Number of class 2 and class 3 fabric busy (F_BSY) frames generated by this port
in response to incoming frames. This usually indicates a busy condition on the
fabric or N_Port that is preventing delivery of this frame.
Link Failures
Number of optical link failures detected by this port. A link failure is a loss of
synchronization for a period of time greater than the value of R_T_TOV or by loss
of signal while not in the offline state. A loss of signal causes the switch module
to attempt to reestablish the link. If the link is not reestablished by the time
specified by R_T_TOV, a link failure is counted. A link reset is performed after a
link failure.
Primitive Sequence Errors Number of bad primitives received by the port.
Rx Link Resets Number of link reset primitives received from an attached device.
113
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 28. Port Statistics Data window entries (continued)
Entry
Description
Tx Link Resets
Number of link reset primitives sent from this port to an attached port.
Number of offline sequence primitives received by the port.
Number of offline primitives transmitted by the port.
Total number of primitive and nonprimitive port link errors.
Total number of frames transmitted by the port.
Rx Offline Sequences
Tx Offline Sequences
Total Errors
Total Tx Frames
Total Rx Frames
Total Tx Words
Total number of frames received by the port.
Total number of words transmitted by the port.
Total Rx Words
Total number of words received by the port.
Total Link Resets
Total Offline Sequences
Number of link-reset primitives that are transmitted by the port.
Total number of offline sequences transmitted and received by the port.
See Table 37 on page 131 for information about port numbering and mapping.
Port Information data window
The Port Information data window displays port detail information for the selected port. To open the Port
Information data window, click the Port Info tab below the data window in the Faceplate window.
Table 29. Port Information Data window entries
Entry
Port Address
Description
Port Fibre Channel address.
Administrative Port Mode
Operational Port Mode
Administrative Port State
Operational Port State
The current administrative port mode: GL, G, FL, F, TL.
The operational port mode.
The current administrative port state: online, offline, diagnostics, or down.
The operational port state.
Configured Administrative
Port State
The port administrative state that is stored in the switch module configuration.
Logged In
Indicates whether logged in or not.
E Port Connection Status
E Port Isolation Reason
MFS Mode
Indicates whether the E_Port connection is enabled.
Indicates why the E_Port is isolated.
Port tuning indicator.
I/O Stream Guard
Administrative Port Speed
Operational Port Speed
TLMode
Whether RSCN suppression is enabled or disabled.
The speed requested by the user.
The speed actually used by the port.
Indicates if TL target or TL initiator is used.
Indicates whether the buffer-to-buffer credits are set.
Indicates whether the extended credits are requested for ports.
The SFP module type.
BB Credits
Ext Credits Requested
Medium
114 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Name Server Data window
The Name Server Data window displays information about the port and the connected device. To open the
Name Server Data window, select one or more switch modules in the Topology window and click the Name
Server tab below the data window. You can also open the Name Server Data window in the Faceplate window.
See Table 19 on page 100 for a description of the Name Server Data window entries.
Configuring ports
✏ NOTE
For external ports (0, 15), all port parameters apply. For internal ports, only the port state setting is
configurable.
The external Fibre Channel ports are self-configuring GL_Ports that auto-negotiate transmission speeds of 1
Gbps or 2 Gbps depending on the connected device. A GL_Port connects to a loop of public devices or a
single device and configures itself as a fabric loop port (FL_Port), fabric port (F_Port), or an expansion port
(E_Port). Each external port has 12 buffer credits. This enables a cable length up to 20 km at 1 Gbps or 10 km
at 2 Gbps. Eleven credits from one port can be borrowed by the other port to extend transmission distances.
The buffer credit flow control mechanism provides a way to ensure full use of the media, regardless of length,
by providing for frame streaming. With frame streaming, the sender can transmit as many frames as there are
credits without having to wait for a response to one frame before transmitting the next frame. The media can
then be continuously in use at its rated capacity.
The external port (0,15) settings or characteristics are configured using the Port Properties window shown in
Figure 18 To open the Port Properties window, select one or more external ports and click Port / Port
Properties.
Figure 18. External Port Properties window
The Port Properties window displays the switch module name and the selected external ports. Use the Port
Properties window to change the following parameters:
•
•
•
•
•
•
Port state
Port speed
Port mode
TL mode
Port buffer credits
I/O stream guard (RSCN suppression)
115
Download from Www.Somanuals.com. All Manuals Search And Download.
Internal port (1 through 14) configuration is limited to the port state as shown in Figure 19 on page 116. To
open the Port Properties window, select one or more internal ports and click Port / Port Properties.
Figure 19. Internal Port Properties window
Changing port administrative states
The Port Administrative state determines the operational state of a port. The port administrative state exists in
two forms: the configured administrative state and the current administrative state.
The Configured Administrative state is the state that is saved in the switch module configuration and is
preserved across switch module resets. The SAN Utility always makes changes to the configured
administrative state.
The Current Administrative state is the state that is applied to the port for temporary purposes and is not
preserved across switch module resets. The current administrative state is set using the Set Port command. See
“Set Port command” on page 37 for more information. See Table 30 on page 117 for additional port
administrative state descriptions.
The Port Administrative state determines the internal and external port operational state. The port
administrative state refers to the requested state in the SAN Utility or through a Telnet command. The port
operational state refers to the state actually used by the port.
Complete the following steps to change the port administrative state:
1. Select one or more ports in the Faceplate window.
2. Click Port / Port Properties.
The Port Properties window opens.
3. Click the Port States that corresponds to the port state you
want.
4. Click OK to write the new port state to the switch module.
116 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 30. Port administrative states
State
Description
Online
Offline
Test
Activates and prepares the port to send data.
The port cannot receive a signal or accept a device login.
Prepares a port for testing and prevents the port from accepting a device login.
Changing port speeds (external ports only)
The switch module external ports (0,15) are capable of transmitting and receiving at 1 Gbps or 2 Gbps. The
ports are configured for either transmission speed or to sense the transmission speed of the device to which it is
connected. Internal ports (1 through 14) are fixed at 2 Gbps. Table 31 describes the port speeds. Complete the
following steps to change the port speed:
1. Select one or more ports in the Faceplate window.
2. Click Port / Port Properties.
3. Select the speed that you want.
4. Click Apply to write the new port speed to the switch module.
Table 31. Port speeds
State
Description
Auto-detect
Matches the transmission speed of the connected device. Auto-detect is the
default.
1 Gb
2 Gb
Sets the transmission speed to 1 Gbps.
Sets the transmission speed to 2 Gbps.
Changing port modes (external ports only)
The switch module external ports (0,15) support both public and private devices as single devices or in loops.
External ports can be configured to self-discover the proper mode to match the device or switch module to
which it is connected. Internal ports (1 through 14) are fixed as F_Ports. Table 32 describes the port modes.
Complete the following steps to change the port mode:
1. Select one or more ports in the Faceplate window.
2. Click Port / Port Properties.
The Port Properties window opens.
3. Select the Port Mode speed that you want.
4. Click OK to write the new port mode to the switch module.
Table 32. Port modes
State
Description
F_Port
Fabric port - Supports a single public device (N_Port).
Fabric loop port - Supports a loop of up to 126 public devices (NL_Port).
FL_Port
117
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 32. Port modes (continued)
State
Description
TL_Port
Translated loop port - Supports a loop of up to 124 private target devices or 125
private initiator devices capable of communicating with up to 63 off-loop initiator
devices or 64 off-loop target devices.
G_Port
GL_Port
Donor
Generic port - Self-discovers as an F_Port or an E_Port.
Generic loop port - Self-discovers as an F_Port, FL_Port, or an E_Port.
Donor port - Allows buffer credits to be used by another port.
Configuring translated loop (TL) modes (external ports only)
You can configure an external (0,15) TL_Port to support a loop of private target devices or a loop of private
initiator devices.
•
For a loop of up to 124 private target devices, click TL Target. This enables up to 63 initiator devices
anywhere in the fabric to automatically connect with the private devices on the TL_Port. Group the
TL_Port and up to 63 initiators in the same soft or ACL zone using the worldwide name or domain ID and
port ID membership, to limit the number of possible initiators to 63.
•
For a loop of up to 125 private initiator devices, click TL Initiator. This enables the private initiators on
the TL_Port to automatically connect to up to 64 target and initiator devices in the same soft or ACL zone.
You must group the TL_Port and the target devices in the same soft or ACL zone using the worldwide
name or domain ID and port ID membership. If there are more than 65 members in the zone, the TL_Port
is unable to communicate with the fabric.
Changing buffer-to-buffer credits (external ports only)
Each switch module external port (0,15) has a receive buffer capacity of 12 Fibre Channel frames or credits,
which is equal to approximately 24 KB. Port buffer credits can be changed on ports to accommodate
connections to other switch modules that have different port buffer capacities. Complete the following steps to
change external port buffer credits:
1. Select one or more ports in the Faceplate window.
2. Click Port / Port Properties.
3. In the E_Port BB Credits field, type the new number.
4. Click OK to write the new buffer-to-buffer setting to the switch module.
I/O stream guard
The I/O Stream Guard feature suppresses registered state control notification (RSCN) messages on external
ports (0,15).
Extending port credits
Each external port (0,15) is supported by a data buffer with a 12-credit capacity; that is, 12 maximum sized
frames. For fiber-optic cables, this enables full bandwidth class 2 service over a distance of 20 km (12.4 mi) at
1 Gbps (0.6 credits per km), or 10 km (6.2 mi) at 2 Gbps (1.2 credits per km). Longer distances can be spanned
at full bandwidth by borrowing credits from designated donor ports; therefore, pooling the buffer capacities.
This is called credit extension. Each donor port contributes 11 credits to the pool from which the recipient
ports can draw. Only external ports (0,15) can be donor or recipient ports. For example, one donor port
contributes 11 credits to the pool from which a recipient draws for a total of 23 credits (11+12). This provides
approximately 38 Km (23.6 mi) at 1 Gbps (23÷0.6) or 19 km (11.8 mi) at 2 Gbps (23÷1.2).
118 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Complete the following steps to extend port buffer credits:
1. In the Faceplate window, select the ports that are to serve as donor ports. Click Port / Port Properties.
In the Port Properties window, click Donor / OK.
✏ NOTE
Donor ports are incapable of transmitting or receiving data.
2. In the Faceplate window, select the recipient port. Recipient ports must be external ports configured as
G_Ports or F_Ports. Click Port / Extended Credits. The Extended Credits window opens as
shown in Figure 20
Figure 20. Extended Credits window
3. Distribute the borrowed credits by incrementing the Ext Credits Requested field for the
recipient ports up to the total credits in the pool. Click OK. If you exceed this total, a message is
entered in the alarm log indicating that some recipient ports did not receive the requested credits.
4. To confirm that the requested credits were received, reopen the Extended Credits window and match the
number of credits in the Ext Credits Requested column with the number in the Donated to Port
column.
✏ NOTE
As credits are used, the Logged-in LEDs on the corresponding donor ports are lit continuously. In
addition, donor port Activity LEDs will reflect the same traffic as the recipient port. Donor ports
whose credits are being used are unavailable to devices that are connected to them.
119
Download from Www.Somanuals.com. All Manuals Search And Download.
Resetting a port
The Reset Port option reinitializes the port using configuration parameters stored in memory. Complete the
following steps to reset a port:
1. In the Faceplate window, select the ports to be reset.
2. Click Port ” Reset Port.
To run an internal, external, or online port loopback test on an external port, see “Port testing” on page 124.
120 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4 Switch management utility functions
This chapter contains information about the following topics:
•
•
•
•
•
LED diagnostics
Port testing
Fibre Channel switch module monitoring using SNMP
Restoring Fibre Channel switch module configuration defaults
Using the Fabric View application
LED diagnostics
The Fibre Channel switch module performs a POST as part of its power-on procedure. The POST diagnostic
program performs the following tests:
•
•
•
Checksum tests on the boot firmware in PROM and the switch module firmware in flash memory
Internal data loopback test on all ports
Access and integrity test on the switch module ASIC
During the POST, the switch module logs any errors encountered. Some POST errors are fatal; others are non-
fatal. The switch module uses the heartbeat LED and the logged-in LED to indicate switch and port status. A
fatal error disables the switch module so that it will not operate. If a non-fatal error occurs, the switch module
can still operate but disables the ports that have errors. Regardless of whether the problem is fatal or nonfatal,
contact your technical support representative.
If there are no POST errors, the heartbeat LED flashes at a steady rate of once per second. If a fatal error
occurs, the heartbeat LED will show an error flash pattern. If there are non-fatal errors, the switch module
disables the failed ports and flashes the associated logged-in LEDs. See “Heartbeat LED patterns” on page 122
for more information about heartbeat LED flash patterns.
There are three sets of LEDs on the information panel. The first row of LEDs at the top of the switch module
represent switch module status and include OK, ♥ (heartbeat), and ! (Fibre Channel switch fault). The second
and third sets of LEDs represent status for external Fibre Channel port 2 and external Fibre Channel port 1.
The port LEDs include port logged-in, port activity, and port fault. Figure 21 on page 122 shows the location
of these LEDs on the switch module. For more information about switch module LEDs, see the Fibre Channel
Switch Module Installation Guide.
121
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 21. Switch module LEDs
Heartbeat LED patterns
The heartbeat LED uses different flash patterns to indicate the following conditions:
•
•
•
•
Normal
Internal firmware failure
Fatal error
Configuration file system error
Normal (all pass) LED flash pattern
If POST diagnostics pass and the switch module processor is operating correctly, the switch will go to normal
operation, and the heartbeat LED will flash at a steady rate of one flash per second.
Internal firmware failure LED flash pattern
An internal firmware failure flash pattern is two flashes per second followed by a 2-second pause, as shown in
the following illustration. The two-flash error pattern indicates that the firmware has failed and that the switch
module must be reset.
Fatal error LED flash pattern
A fatal error flash pattern is three flashes per second followed by a 2-second pause, as shown in the following
illustration. The three-flash error pattern indicates that a fatal error has made the switch module inoperable. If
a fatal error occurs, contact your technical support representative.
122 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuration file system error LED flash pattern
A configuration file system error flash pattern is four flashes per second followed by a 2-second pause, as
shown in the following illustration. The four-flash error pattern indicates that a configuration file system error
has occurred.
Switch module fault LED flash pattern
The amber Switch Fault LED is lit to indicate one or more of the following conditions:
•
•
•
POST failure
Over temperature condition
Port operational test failure. See “Port fault LED flash patterns” on page 124 for information about port
operational tests.
If the Switch Fault LED is lit for reasons other than a port operational test failure, take the Fibre Channel
switch module offline and contact your technical support representative.
Switch module OK LED
The green OK LED is lit to indicate that the switch module has completed POST diagnostics without errors. If
this LED is not lit when you turn on the SBCE unit or turns off during operation, remove the switch module
and inspect the connector for damage.
Port logged-in LED flash patterns
The Port Logged-in LED has the following flash patterns:
•
•
•
Logged in - The logged-in LED is lit continuously.
Logging in - The logged-in LED flashes at once per second as shown in the following illustration.
Set beacon - Enables or disables the flashing of the Port Logged-in LEDs according to [state]. For
•
Error - The logged-in LED flashes at twice per second as shown in the following illustration.
Logging in
Error
A logged-in LED error indication is often the result of E_Port isolation. Table 33 on page 124 describes the
causes and remedies for E_Port isolation conditions. An isolated E_Port is indicated by a red link in the
“Zoning a fabric” on page 88 for information about how to set IDs, timeout values, and edit zoning.
123
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 33. E-port isolation causes and fixes
Isolation cause
Fix
Two switch modules in the same fabric
have the same domain ID
Correct the domain IDs on the malfunctioning switch modules.
Domain IDs are decimal numbers in the range from 1 to 239.
Domain IDs must be unique.
All switch modules in the fabric do not
have the same timeout values
Correct the timeout values on the malfunctioning switch modules.
When merging two fabrics, the active
zone sets contain zones with the same
names but different membership.
Deactivate one of the active zone sets or edit the conflicting zones
so that their membership is the same. The conflicting zones have
the same name but different membership. Take the affected ports
offline then back online to restore the interswitch links.
Port fault LED flash patterns
The amber port fault LED is lit to indicate that the port has failed one of the following port operational tests
performed with the SAN Utility or the CLI:
•
•
•
Internal
External
Online
If the port fault LED is lit, take the port offline and contact your technical support representative.
Port testing
The port loopback tests verify correct port operation by sending a test data frame out through the loop and then
verifying that the frame received matches the frame that was sent. You can perform the following port tests
from the Port Loopback window:
•
Internal SerDes test (internal and external ports) - The SerDes (serializer/deserializer) level test
verifies internal and external port circuitry. The SerDes level test sends a test frame from the
ASIC through the SerDes chip and back to the ASIC for the selected internal ports. The port
passes the test if the frame that was sent by the ASIC matches the test frame that was received.
✏ NOTE
A loopback plug is required to perform an external SFP test.
•
•
External SFP test (external ports only) - The SFP level test also verifies port circuitry. The SFP level test
sends a test frame from the ASIC through the SerDes chip, through the SFP module fitted with the
loopback plug, and back to the ASIC for the selected external ports. The external port passes the test if the
test frame that was sent by the ASIC matches the test frame that was received.
Online node-to-node test (internal ports) - The node-to-node test verifies communications between the
port and its device node or device loop. The port being tested must be online and connected to a device.
The port passes the test if the test frame that was sent matches the test frame that was received.
124 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 22. Port Loopback Test window
✏ NOTE
The internal SerDes and external SFP level tests disrupt communication on the selected port. The
online node-to-node level test does not disrupt communication, because it requires that the port is
online.
Complete the following steps to run the internal, external, or online port loopback test on an external port:
1. In Faceplate window, select the external port to be tested.
2. Click Port / Port Loopback Test. The Port Loopback Test window opens.
3. In the test selection pane, select the type of loopback test (internal, external, or online) to be run. If you
want to run the internal or external test, the SAN Utility prompts you to confirm that the port state needs
to be changed to the diagnostic state. Click OK. The SAN Utility changes the port state.
4. Type the frame count, frame size, and select a test pattern. You can use the default pattern or type an 8-
digit pattern (hexadecimal). For online tests, click the Terminate Test Upon Error check box if you
want the test to stop when encountering an error.
5. Click Start Test to begin the test. The test results pane displays the test status, number of frames sent,
and number of errors found.
Fibre Channel switch module monitoring using SNMP
This section describes SNMP configuration and trap parameters. The switch module SNMP agent enables
external network management monitoring and notification of switch module status.
SNMP configuration
SNMP configuration defines how authentication traps are managed. Table 34 describes the SNMP
configuration parameters.
125
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 34. SNMP configuration parameters
Parameter
Description
Contact
Specifies the name of the person to contact for trap events. The default is
undefined.
Read community
Read Community Authentication. A write-only field; the value on the switch
module and the SNMP management server must be the same. The default value
is Public.
Trap community
Trap Community Authentication. A write-only field; the value on the switch
module and the SNMP management server must be the same. The default value
is Public.
Location
Specifies the switch module location. The default is undefined.
Authentication trap
Enables or disables the reporting of SNMP authentication failures. If enabled,
and the incorrect community string values are used, an authentication failure
event occurs and a notification trap is sent to the configured trap addresses. The
default value is False.
Write community
Write Community Authentication. A write-only field; the value on the switch
module and the SNMP management server must be the same. The default value
is Private.
SNMP trap configuration
The SNMP trap configuration defines how traps are set. Table 35 describes the SNMP trap configuration
parameters.
Table 35. SNMP trap configuration parameters
Parameter
Trap enabled
Description
Select this check box to enable or disable the trap.
Trap address
Specifies the IP address to which SNMP traps are sent. The default is 10.0.0.1
for trap 1 and 0.0.0.0 for traps 2–5. A maximum of five trap addresses are
supported.
Trap port
The port number on which the trap is set.
Trap severity
Specifies a severity level to assign to the trap. Open the menu and select a
level. Traps must be enabled to access this menu. Trap severity levels include
Unknown, Emergency, Alert, Critical, Error, Warning, Notify, Info, Debug, and
Mark.
126 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Restoring Fibre Channel switch module configuration
This section describes switch module configuration restoration tasks that are performed using the Telnet CLI
interface and the management module.
Configuration backup
Changes made to the switch module since it was manufactured can be saved to a file in nonvolatile memory.
However, the backup file is lost if the switch module is reset. Use the File Transfer Protocol (FTP) user images
procedures to save the configdata file to the network management workstation. (In FTP, no directory listing is
available. The configuration backup file is always named configdata.) For information about SNMP
Configuration restore
Switch module configurations can be duplicated to easily propagate an identical configuration to other switch
modules. Use the FTP User Images procedures with the Put command to send the previously saved (using
config backup) configdata file to the switch module. In Telnet, use the Config Restore command to return the
switch module configuration to the previously saved configuration. The switch module is automatically reset
after a successful restore.
Restoring the factory default configuration
You can restore the switch module and port configuration settings to the factory default values. To restore the
factory configuration on a switch module, click Switch / Restore Factory Defaults. Table 36 lists the factory
default switch module configuration settings. Restoring the switch module to the factory default configuration
does not restore the login name and password settings.
Table 36. Factory default configuration settings
Settings
Module name
Value
Fibre Channel switch module
Administrative state
Domain ID
Online
1
Resource allocation time
out (RA_TOV)
10000 milliseconds
Receiver transmitter
timeout (RT_TOV)
100 milliseconds
2000 milliseconds
Error detect timeout
(ED_TOV)
IP address
Switch module bay 3: 192.168.70.129
Switch module bay 4: 192.168.70.130
255.255.255.0
Subnet mask address
Gateway address
Boot method
Contact
10.90.90.254
Static
Undefined
Location
Undefined
Trap address
Trap 1: 10.0.0.1, Traps 2–5: 0.0.0.0
127
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 36. Factory default configuration settings (continued)
Settings
Value
Trap community
Read community
Write community
Port state
Public
Public
Private
Online - external ad internal ports
Auto-detect - external; 2G - internal
GL - external; F - internal
Port speed
Port mode
Reinitializing the configuration file system
If the heartbeat LED on the switch module is showing the four-flash pattern, the configuration file system
might be damaged. To recover the factory switch module configuration, use the Config Restore Telnet
command. The heartbeat LED four-flash pattern continues until a previous switch module configuration is
successfully restored. The heartbeat LED is not reflected in the SAN Utility.
Restoring a switch module
Restoring a switch module loads the archived switch configuration parameters to the switch module. The
switch module configuration must be archived before it can be restored. See “Archiving a switch module” on
page 108 for more information.
1. Log in to the fabric through the switch module you want to restore. You cannot restore a switch module
over an ISL.
2. In the Faceplate window, click Switch / Restore.
3. In the Restore window, type the archive file name or browse for the file.
4. Click Restore.
Using the Fabric View application
You can use the Fabric View application to view port performance as graphs. The Fabric View window
displays data communication rates and total errors for selected ports as shown in Figure 23 on page 129. You
can graph communication data rates using either frames per second or KB per second.
This section provides the instructions you need to perform the following tasks in the Fabric View window:
•
•
•
•
Start the Fabric View application
Display port performance graphs
Arrange and size port performance graphs
Customize port performance graphs
128 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Figure 23. Fabric View graphs
Starting the Fabric View application
To start Fabric View using the SAN Utility, open the Faceplate window and click Start Fabric View from the
Switch menu.
Displaying port performance graphs
Complete the following steps to display port performance graphs:
1. Click Fabric and select Add Fabric or click the Add button. Type a fabric name and an IP address in
the Add a New Fabric window. Include a login name and a password if required.
2. Set the graphing options and polling frequency. By default, the Fabric View application plots total bytes
transmitted and received at a polling frequency of once per second. See “Customizing port performance
graphs” on page 130 for information about changing what is plotted and how it is plotted.
3. Select a switch module icon in the Fabric Tree to display a graph for each logged-in port on that switch
module, or display a graph for a single port by clicking on the switch module entry handle and selecting
one or more ports.
4. You can move graphs individually by clicking and dragging, or you can arrange them as a group. See
5. To remove a graph, click Close. To remove all graphs, click View and click Close All Graphs.
Fabric View can access only one fabric at a time. To access another fabric, you must first remove the current
fabric. To remove a fabric, click Fabric and select Remove Fabric or click the Remove button.
Arranging and sizing port performance graphs
Complete the following steps to arrange and size graphs in the Fabric View window:
1. Click View and select Tile Graphs Vertically. Tiling vertically sizes and arranges the graphs in the
longest columns possible.
2. Click View and select Tile Graphs Horizontally. Tiling horizontally sizes and arranges the graphs in the
longest rows possible.
3. Click View and select Cascade Graph Panels. Cascading overlaps the graphs so that all graphs are at
least partially visible.
129
Download from Www.Somanuals.com. All Manuals Search And Download.
Customizing port performance graphs
You can customize the graph polling frequency, what is plotted in the graphs, and the graph color scheme.
Complete the following steps to customize the port performance graphs:
1. To set the polling frequency for all graphs, click Graph and click Set Polling Frequency.
2. Type an interval, in seconds (0 through 60), and click OK.
3. To select what is to be plotted, click Graph and click Options. The Modify Graph Display window
opens.
Figure 24. Modify Graph Display window
4. To modify the graph display, select the units for the graph:
•
•
Select the Show Bytes Data on Graph check box to plot data in KB per second.
Select the Show Frames Data on Graph check box to plot data in frames per second.
5. Choose what data type to plot. For example, if you selected Show Frames Data on Graph in step 4 you
can plot one or all of the following:
•
•
•
Total frames transmitted and received (Total Frames)
Total frames transmitted (Total Tx Frames)
Total frames received (Total Rx Frames)
In addition to these, you can also plot total errors by selecting the Total Errors check box.
6. Display or hide the unit grid. Select the Display Grid on Graph check box to display the unit grid.
7. Choose the color scheme for the graph. You can select the color for each data type, the unit grid, and the
background by clicking the corresponding color field or button. In each case, you can choose a color using
the swatches, Red-Green-Blue (RGB), or Hue-Saturation-Brightness (HSB):
•
•
Swatches – Click the Swatches tab. Select a swatch from the palette and click OK.
RGB – Click the RGB tab. Select a color by moving the slides to adjust the values for red, blue, and
green; or type values in the fields. Click OK.
•
HSB – Click the HSB tab. Select a color using any of the following methods and click OK:
— Click in the color palette.
— Select H, S, or B and use the slide to vary the selected value.
— Type values in the H, S, or B fields.
130 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
A Mapping port locations and software
numbering
Your switch module has two external Fibre Channel ports (external Fibre Channel port 1 and external Fibre
Channel port 2) and 14 internal Fibre Channel ports that connect to each of the 14 blade server bays (ports 1 to
14). The SAN Utility and CLI for the switch module require port numbering from 0 to 15. The SNMP
monitoring agent for the switch module numbers the ports from 1 to 16.
Port mapping
Table 37 shows the mapping of switch module port numbering and whether the port has the capability to be
configured.
Table 37. Port mapping
Switch module physical port
connection
SAN Utility and CLI logical
port number
SNMP port
numbering
Configurable
Yes
External port 1
0 (Ext1:0*)
1
Blade server bay 1
Blade server bay 2
Blade server bay 3
Blade server bay 4
Blade server bay 5
Blade server bay 6
Blade server bay 7
Blade server bay 8
Blade server bay 9
Blade server bay 10
Blade server bay 11
Blade server bay 12
Blade server bay 13
Blade server bay 14
External port 2
1
2
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
11
12
13
14
15
16
10
11
12
13
14
15 (Ext2:15*)
* Indicates a symbolic port name if it is different from the logical port number.
✏ NOTE
The Fibre Channel ports that connect to each of the blade server bays (1 through 14) are fixed 2 Gbps
F_Port configurations. Only the administrative state for these ports can be changed.
131
Download from Www.Somanuals.com. All Manuals Search And Download.
132 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
B Getting help and technical assistance
If you need help, service, or technical assistance or just want more information about ®products, you can
contact your Intel support representative. This appendix contains information about where to go for additional
information about Intel products, what to do if you experience a problem with your SBCE unit, and whom to
call for service, if it is necessary.
Before you call
Before you call, make sure that you have taken these steps to try to solve the problem yourself:
•
•
•
Check all cables to make sure that they are connected.
Check the power switches to make sure that the system is turned on.
Use the troubleshooting information in your system documentation, and use the diagnostic tools that
come with your system.
You can solve many problems without outside assistance by following the troubleshooting procedures
provided in the publications that shipped with your system and software. The information that comes with
your system also describes the diagnostic tests that you can perform. If you suspect a software problem, see
the information for the operating system or program.
Using the documentation
See the troubleshooting information in your system documentation for instructions for using the diagnostic
programs. The troubleshooting information or the diagnostic programs might tell you that you need additional
or updated device drivers or other software.
Hardware/Software service and support
Contact your Intel Support Representative for additional hardware or software support.
133
Download from Www.Somanuals.com. All Manuals Search And Download.
134 Intel Blade Server Switch Module SBCEFCSW Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
C Notices
Important notes
Processor speeds indicate the internal clock speed of the microprocessor; other factors also affect application
performance.
CD-ROM drive speeds list the variable read rate. Actual speeds vary and are often less than the maximum
possible.
When referring to processor storage, real and virtual storage, or channel volume, KB stands for approximately
1000 bytes, MB stands for approximately 1 000 000 bytes, and GB stands for approximately 1 000 000 000
bytes.
When referring to hard disk drive capacity or communications volume, MB stands for 1000000 bytes, and GB
stands for 1000 000 000 bytes. Total user-accessible capacity may vary depending on operating environments.
Maximum internal hard disk drive capacities assume the replacement of any standard hard disk drives and
population of all hard disk drive bays with the largest currently supported drives available from .
Maximum memory may require replacement of the standard memory with an optional memory module.
Intel Corporation makes no representations or warranties with respect to non- products. Support (if any) for
the non- products is provided by the third party, not by Intel.
Some software may differ from its retail version (if available), and may not include user manuals or all
program functionality.
135
Download from Www.Somanuals.com. All Manuals Search And Download.
Regulatory Specifications and Disclaimers
Declaration of the Manufacturer or Importer
We hereby declare that this product is in compliance with European Union EMC Directive 89/336/EEC,
using standards EN55022 (Class A) and EN55024 and Low Voltage Directive 73/23/EEC, Standard
EN60950.
Safety Compliance
USA:
UL 60950 – 3rd Edition/CSA 22.2. No. 60950
Canada:
cUL certified – 3rd Edition/CSA 22.2. No. 60950- for Canada (product bea
the single cUL mark for U.S. and Canada)
Europe:
Low Voltage Directive, 73/23/EEC
TUV/GS to EN60950 2nd Edition with Amendments, A1 = A2 + A3 + A4
International:
TUV/CB to IEC 60950 3rd Edition
TUV/CB - EN60 950 2nd Edition + Amd 1-4
TUV/CB - EMKO-TSE (74-SEC) 207/94
Australian /
CB Report to IEC 60950, 3rd Edition plus international deviations
New Zealand:
Electromagnetic Compatibility (EMC)
USA:
FCC CFR 47 Part 2 and 15, Verified Class A Limit
Canada:
Europe:
IC ICES-003 Class A Limit
EMC Directive, 89/336/EEC
EN55022, Class A Limit, Radiated & Conducted Emissions
EN55024 ITE Specific Immunity Standard
EN61000-4-2 ESD Immunity (Level 2 Contact Discharge, Level 3 Air
Discharge)
EN61000-4-3 Radiated Immunity (Level 2)
EN61000-4-4 Electrical Fast Transient (Level 2)
EN61000-4-5 AC Surge
EN61000-4-6 Conducted RF
EN61000-4-8 Power Frequency Magnetic Fields
EN61000-4-11 Voltage Dips and Interrupts
EN61000-3-2 Limit for Harmonic Current Emissions
EN61000-3-3 Voltage Flicker
Japan:
VCCI Class A ITE (CISPR 22, Class A Limit)
IEC 1000-3-2 Limit for Harmonic Current Emissions
AS/NZS 3548, Class A Limit
Australia/New Zealand:
Taiwan
BSMI Approval
Korea
RRL Approval
China
CCC Approval
Russia
GOST Approved
International:
CISPR 22, Class A Limit
136 SBCEFCSW Module Management and User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
A
access and integrity test 121
access control list (ACL) zones 89
Active Zoneset Data window 88
Add a New Fabric window 84
administrative port state 116
alarm
configuring 103
exporting log information 104
Alarm Log Data window 103
Alarm Threshold Configuration window 103
alias
adding a member 98
command 9
creating 97
defined 90
managing 97
removing from all zones 98
B
beacon feature (paging a switch) 104
BladeCenter management module interface 1
broadcast support 106
buffer-to-buffer credits 118
C
changing port modes 117
changing port speeds 117
checksum test 121
command line interface (CLI) 5
command syntax 6
configuration
auto save parameters 90
backup 127
default visibility parameters 91
factory default 127
file system reinitialization 128
Configured Administrative state 116
Current Administrative state 116
D
diagnostic flash patterns 121
diagnostics test 105
domain ID lock 106
E
Edit Zoning window
port and device tree 92
137
Download from Www.Somanuals.com. All Manuals Search And Download.
using the 92
zone sets tree 92
exporting
alarm log information 104
name server information to file 104
Extended Credits window 119
extending port credits 118
external port
mapping 131
selecting 82
views and status 82
working with 82
External Port Properties window 115
F
fabric
adding 84
database management 84
default configuration 85
managing 83
monitoring 86
opening an existing 85
rediscovering 85
removing 84
replacing a failed switch 86
saving 85
security 83
status 86
fabric tree 77
Fabric View application 102
Fabric View window 129
Faceplate data window tabs
alarm log 83
configured zone sets 83
port information 83
port statistics 83
switch 83
Faceplate window
data window and tabs 73
Display Data windows 110
displaying port speeds 111
fabric tree 73
functional elements 81
graphic window 73
managing switches 83
port operational states 111
port views and status 81
selecting ports 82
toolbar 73
working status indicator 73
working with ports 81
Fibre Channel switch fault LED 121
Fibre Channel switch module 1
138
Book Title
Download from Www.Somanuals.com. All Manuals Search And Download.
firmware
activating the fallback 109
loading 109
managing 109
G
graphic window 77
graphical user interface, SAN Utility
Faceplate window 73
Topology window 73
H
heartbeat LED 121
I
I/O Stream Guard feature 118
in-band management 106
indicators, information panel 121
information panel 121
internal port
mapping 131
selecting 82
working with 82
Internal Port Properties window 115
interswitch links 87
IP address 108
IP address, default
BladeCenter unit bay 3 85
BladeCenter unit bay 4 85
IP configuration parameters
boot method 108
IP gateway address 108
subnet mask 108
L
LEDs
diagnostic flash patterns 121
front view 121
heartbeat 122
OK 123
port fault 124
port logged-in 123
port status 121
POST diagnostics 121
switch fault 123
switch module status 121
Link Data window 101
loopback test 121
M
managing fabrics 83
managing switches 98
mapping ports 131
Index
139
Download from Www.Somanuals.com. All Manuals Search And Download.
menu bar 75
merging fabrics and zoning 91
Modify Graph Display window 130
N
network management workstation
running Microsoft Windows 2000 1
running Red Hat Linux Advanced Server Version 2.1 1
running Red Hat Linux Version 7.x 1
network properties
community settings 107
window 107
node worldwide name (NWWN) 100
node-to-node test 124
notes, important 135
notices used in this book 3
O
OK LED 121
P
paging a switch with the beacon feature 104
pop-up menus 82
port
activity LED 121
administrative state 116
changing mode 117
external 82
fault LED 121
internal 82
logged-in LED 121
loopback test 124
mapping 131
node-to-node test 124
operational state 111
selecting 82
SerDes level test 124
SFP level test 124
views and status 82
working with 82
Port Administrative state 116
port graphing 112
Port Information Data window 102
Port Statistics Data window 102
port worldwide name (PWWN) 100
power-on self-test (POST) 121
publications, related 1
R
registered state change notification (RSCN) 30
related publications 1
Remote Logging (syslog) feature 108
restoring default zoning 91
140
Book Title
Download from Www.Somanuals.com. All Manuals Search And Download.
S
SAN devices 1
SAN Utility application
managing multiple switches 1
user interface 73
using 73
SerDes level test 124
SFP level test 124
small form-factor pluggable (SFP) module
displaying media status 112
port operational state 111
SNMP configuration parameters
authentication trap 126
changing 107
community authentication 126
contact 125
location 126
soft zoning 89
Switch Data window 100
switch management utility functions
LED diagnostics 121
port testing 124
restoring switch module configuration defaults 127
switch module monitoring using SNMP 125
using the Fabric View application 128
switch module
administrative states 105
archiving configuration parameters 108
ASIC 121
configuring 105
configuring using the Telnet interface 5
default password 5
default user ID 5
displaying information 99
IP addresses 5
monitoring 125
resetting 104
setting the date and time 104
XML archive file 108
Switch Properties window 105
symbolic name 105
T
Telnet interface 5
logging on to a switch module 5
timeout values 107
toolbar 76
Topology Data window tabs
active zoneset 81
link 81
name server 81
switch 81
Topology window
arranging switches 80
data window and tabs 73
Index
141
Download from Www.Somanuals.com. All Manuals Search And Download.
deleting a switch 86
fabric tree 73
functional elements 78
graphic window 73
selecting a switch 80
switch and link status 78
switch and status icons 87
toolbar 73
using the 78
working status indicator 73
translated loop (TL) modes 118
V
virtual private fabric (VPF) zones 89
W
working status indicator 78
Z
zone
a database 90
a fabric 88
adding members to a 96
configuration parameters 90
defined 89
hard zone access control list 89
hard zone virtual private fabric 89
management 95
merge failure 91
merge failure recovery 92
orphan 90
removing a member 96
renaming 96
set 90
soft zone 89
zone set
activating and deactivating 94
copying an existing 94
creating 94
managing 93
removing a zone from a 94
removing definitions 95
Zoning Config window 91
142
Book Title
Download from Www.Somanuals.com. All Manuals Search And Download.
|