Intel Computer Hardware MFS5000SI User Manual

Intel® Modular Server System MFSYS25,  
Intel® Modular Server System MFSYS35,  
Intel® Compute Module MFS5000SI  
Tested Hardware and Operating System List  
Revision 1.9  
March, 2009  
Enterprise Platforms and Services Division  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
Disclaimers  
THE INFORMATION IN THIS DOCUMENT IS PROVIDED "AS IS" WITH NO WARRANTIES WHATSOEVER,  
INCLUDING ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR ANY PARTICULAR PURPOSE, OR ANY  
WARRANTY OTHERWISE ARISING OUT OF ANY PROPOSAL, SPECIFICATION, OR SAMPLE.  
Information in this document is provided in connection with Intel® products. No license, express or implied, by  
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's  
Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any  
express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to  
fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property  
right. Intel products are not intended for use in medical, life saving, or life sustaining applications.  
Intel retains the right to make changes to its test specifications at any time, without notice.  
The hardware vendor remains solely responsible for the design, sale and functionality of its product, including any  
liability arising from product infringement or product warranty.  
Copyright © Intel Corporation 2009. All rights reserved.  
Intel, the Intel logo, and EtherExpress are trademarks or registered trademarks of Intel Corporation or its subsidiaries  
in the United States and other countries.  
*Other names or brands may be claimed as the property of others.  
iii  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
Table of Contents  
4
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
1. Introduction  
This document is intended to provide users of the Intel® Modular Server System  
MFSYS25/MFSYS35 and Intel® Compute Module MFS5000SI with a guide to the different  
operating systems, expansion cards, and peripherals Intel plans to test on this platform.  
This document will continue to be updated as new expansion cards, peripherals, and operating  
systems are tested or until the Intel® Modular Server System MFSYS25/MFSYS35 and Intel®  
Compute Module MFS5000SI are no longer in production. Each new release of the document  
will present updated information as well as continue to provide the information from previous  
releases.  
Intel will only provide support for those expansion cards and peripherals under the specified  
system configuration (System BIOS and Firmware revisions) and operating systems versions  
with which they were tested.  
1.1 Test Overview  
Testing performed on the Intel® Modular Server System MFSYS25/MFSYS35 and Intel®  
Compute Module MFS5000SI is classified under two separate categories: Basic Installation  
Testing, and Expansion Card/ Peripheral Compatibility and Stress Testing.  
1.1.1  
Basic Installation Testing  
Basic installation testing is performed with each supported operating system. Basic installation  
testing validates that the server board can install the operating system and that the base  
hardware feature set is functional. A small set of peripherals is used for installation purposes  
only. No expansion cards are tested. Testing includes network connectivity and running of  
proprietary and industry standard test suites.  
The latest version of an operating system signifies the latest supported version  
at the time of the actual test run. Each new release of this document may have  
a newly supported release of a given operating system. Previous releases of a  
supported operating system may not be tested beyond the basic installation  
test process.  
1.1.1.1  
Support Commitment for Basic Installation Testing  
Intel commits to provide the following level of customer support for operating systems that  
receive only basic installation testing:  
Intel will provide and test operating system drivers for each of the server board’s  
integrated controllers, provided that the controller vendor has a driver available upon  
request. Vendors will not be required by Intel to develop drivers for operating systems  
that they do not already support. This may limit the functionality of certain server board  
integrated controllers.  
Intel will support customer issues that involve installation and/or functionality of  
operating system with the server board’s integrated controllers only if a driver has been  
made available.  
6
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
Intel will NOT provide support for issues related to use of any 3rd party expansion cards  
or peripherals installed in the server system when an operating system that received  
basic installation testing only is in use.  
Support is defined as assistance in root causing issues, and determining a customer  
acceptable resolution to the issue associated with the operating system. The resolution  
may include, but is not limited to on-board controller driver changes, engaging the  
vendor for resolution, BIOS changes, firmware changes, or determining a customer  
acceptable workaround for the issue.  
1.1.2  
I/O Expansion Card / Peripheral Compatibility and Stress Testing  
I/O Expansion Card / Peripheral Compatibility and Stress testing is performed only on the most  
current release of a supported operating system at the time of a given validation run. The I/O  
Expansion Card / Peripheral Compatibility and Stress testing process consists of three areas:  
Base Platform, I/O Expansion Card Compatibility, and Stress.  
Base Platform: Each base platform will successfully install a given operating system,  
successfully run a disk stress test, and successfully run a network stress test.  
I/O Expansion Card Compatibility: I/O Expansion Card compatibility validation (CV) testing  
uses test suites to gain an accurate view of how the server performs with the available  
expansion card under the primary supported operating systems. These tests are designed to  
show hardware compatibility between the cards and the server platform and include functional  
testing only. No heavy stressing of the systems or the cards is performed for CV testing.  
Stress Testing: This test sequence uses configurations that include expansion cards in all  
available slots, for a minimum 72-hour test run without injecting errors. Each configuration  
passes an installation test, a Network/Disk Stress test, and tape backup test. Any fatal errors  
that occur will require a complete test restart.  
1.1.2.1  
Support Commitment for I/O Expansion Card / Peripheral Compatibility and  
Stress Testing  
Intel commits to provide the following level of customer support for operating systems that  
receive I/O Expansion Card / Peripheral Compatibility and Stress testing:  
Intel commits to provide the following level of customer support for operating systems that  
receive I/O Expansion Card / Peripheral Compatibility and Stress testing:  
Intel will provide support for customer issues with these operating systems involving  
installation and/or functionality of the server board with or without the I/O Expansion  
Card and peripherals listed in this document as having been tested under the particular  
operating system.  
Support is defined as assistance in root causing issues, and determining a customer  
acceptable resolution to the issue associated with the operating system. The resolution  
may include, but is not limited to on-board controller driver changes, engaging the  
vendor for resolution, BIOS changes, firmware changes, or determining a customer  
acceptable workaround for the issue.  
Intel will provide and test operating system drivers for each onboard video, network, and  
storage controller.  
Revision 1.9  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
Intel will enable vendors to provide driver support for I/O Expansion Cards using these  
operating systems.  
Intel will go through some of the steps to achieve certification to ensure its customers do  
not run across any problems, but the actual certification is the responsibility of the  
individual customer.  
For operating systems, adapter cards, and peripherals not listed in this  
document, there is no support commitment. Intel will consider support requests  
on a case-by-case basis.  
1.2 Pass/Fail Test Criteria  
For each operating system, I/O Expansion card, and peripheral configuration, a test passes if  
specific criteria are met. Specific configurations may have had particular characteristics that  
were addressed on a case-by-case basis. In general, a configuration passes testing if the  
following conditions are met:  
ƒ
The operating system installed without error.  
-
-
-
-
Manufacturer’s installation instructions or Intel’s best-known methods (BKMs) were  
used for the operating system installation.  
In some cases rKVM BKMs used involve workarounds and were required during the  
operating system installation.  
The server system behaved as expected during and after the operating system  
installation.  
Application software installed and executed normally.  
ƒ
ƒ
Hardware compatibility tests ran to completion without error.  
Test software suites executed successfully  
-
-
Test and data files were created in the correct directories without error.  
Files copied from client to server and back compare to the original with zero errors  
reported.  
-
-
Clients remain connected to the server system.  
Industry standard test suites run to completion with zero errors reported.  
All Intel® Compute Module MFS5000SI testing was performed using the Intel® Server Modular  
System MFSYS25 or the Intel® Server Modular System MFSYS35.  
8
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
2. MFS5000SI / MFSYS25 / MFSYS35 Base System  
Configurations  
The following table lists the base system configurations tested. Base system configurations will  
change as new revisions of the Intel® Compute Module MFS5000SI or the Intel® Modular  
Server System MFSYS25/MFSYS35 are released and/or new system software stacks are cut  
onto the boards in the factory. Each base system configuration is assigned an identifier number  
that is referenced in the tables throughout this document. New base system configurations are  
added with each new release of this document.  
Intel will only provide support for I/O expansion cards and peripherals under the  
specified base system configuration and operating systems versions with which  
they were tested.  
The following table lists the base system configuration tested.  
Table 2.1 Base System Configurations Tested  
Intel®  
Modular  
Server  
Compute  
Module  
PBA/TA  
Number  
Unified  
Firmware  
Update  
Rev  
System  
PBA/TA  
Number  
Intel®  
Compute  
Module  
Config  
Id #  
GUI  
Rev  
BIOS  
Rev  
BMC  
FW Rev  
Switch  
Rev  
System  
SCM Rev  
D91400-  
003  
1
MFSYS25  
MFSYS25  
MFSYS25  
MFSYS35  
MFSYS25  
MFSYS35  
MFS5000SI D70726-402  
MFS5000SI D70726-402  
MFS5000SI D70726-402  
MFS5000SI D70726-402  
MFS5000SI D70726-402  
MFS5000SI D70726-402  
P2.0.5  
P2.2.3  
P2.6  
8633  
11328  
14717  
14717  
16239  
16239  
32  
43  
43  
43  
48  
48  
1.25.1  
1.30.3  
1.34.9  
1.34.9  
1.35.1  
1.35.1  
1.0.0.25  
1.0.0.25  
1.0.0.27  
1.0.0.27  
1.0.0.27  
1.0.0.27  
2.91.140.11  
D91400-  
006I  
2
3
4
5
6
2.91.140.45  
3.00.0140.77  
3.00.0140.77  
3.02.0140.15  
3.02.0140.15  
D91400-  
006I  
D91403-  
004  
P2.6  
D91400-  
006I  
P2.7  
D91403-  
004  
P2.7  
Note: All base system configurations tested used the Intel® Compute Module MFS500SI  
Revision 1.9  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
3. Supported Operating Systems & Software  
The following table provides a list of the operating systems and software applications that Intel  
plans to test with the Intel® Compute Module MFS5000SI. Each of the listed operating systems  
was tested for compatibility with the base system configuration listed in Section 2 of this  
document.  
Operating systems are supported only with the specified base system  
configuration(s) with which they were tested.  
The following table also indicates whether each operating system received Basic Installation  
Testing, or Adapter / Peripheral Compatibility and Stress Testing. For information on the  
support commitments for Basic Installation Testing vs. Adapter / Peripheral Compatibility and  
Stress Testing, please reference Section 1 of this document.  
Any variations to the standard operating system installation processes are documented in the  
Installation Guidelines section of this document. If no installation guidelines are noted in the  
following table, then the operating system installed as expected using manufacturer’s  
installation instructions or Intel’s best-known methods.  
Operating systems supported by Intel® System Management Software may be  
different than the operating systems supported by the Intel® Compute Module  
MFS5000SI. Please reference the Readme and User Guide documents that  
are included as part of the Intel System Management Software distribution for  
operating systems that are supported by that release.  
Table 3.1 Operating Systems Tested  
Operating System  
Type of Testing  
Notes  
Intel’s testing was completed with  
Microsoft Windows Server 2003  
Enterprise R2 SP2, 32-bit. Although not  
specifically tested on this product, the  
MFS5000SI compute module also  
supports Microsoft Windows Server  
2003 R2, 32-bit.  
Microsoft Windows* 2003 Enterprise  
(32-bit), R2 SP2  
Configuration 1 - Compatibility  
& Stress  
Intel’s testing was completed with  
Microsoft Windows Server 2003  
Enterprise R2 SP2, 64-bit. Although not  
specifically tested on this product, the  
MFS5000SI compute module also  
supports Microsoft Windows Server  
2003 R2, 64-bit.  
Microsoft Windows* 2003 Enterprise  
(64-bit), R2 SP2  
Configuration 1 -Compatibility &  
Stress  
Microsoft Windows* 2008 Enterprise  
(32-bit)  
Configuration 1 -Compatibility &  
Stress  
Microsoft Windows* 2008 Enterprise  
(64-bit)  
Configuration 1 -Compatibility &  
Stress  
Red Hat Enterprise Linux AS 5.0 U1  
(64-bit)  
Configuration 1 -Compatibility &  
Stress  
Red Hat Enterprise Linux AS 5.0  
U1(32-bit)  
Configuration 1 Basic Installation  
10  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
Operating System  
Type of Testing  
Notes  
SuSE Linux Enterprise Server 10 U1 Configuration 1 - Basic  
(32-bit), Installation, Compatibiltiy Only  
SuSE Linux Enterprise Server 10 U1 Configuration 1 - Compatibility  
(64-bit),  
& Stress  
Operating system was tested and is  
supported by SCO. In addition, this OS  
is currently only supported in a sincle  
SCM environment.  
SCO UnixWare 7.1.4  
Configuration 1 -Compatibility  
Operating system was tested and is  
supported by SCO. In addition, this OS  
is currently only supported in a sincle  
SCM environment.  
SCO OpenServer Release 6  
Configuration 1 -Compatibility  
VMware ESX Server 3.5  
VMware ESXi Server 3.5  
Configuration 1 -Compatibility  
Configuration 1 -Compatibility  
Client Web Browsers (for CMM  
interface)  
Type of Testing  
Notes  
Microsoft Internet Explorer 6.0  
Microsoft Internet Explorer 7.0  
Mozilla Firefox 2.0  
Configuration 1 -Compatibility  
Configuration 1 -Compatibility  
Configuration 1 -Compatibility  
Client Java Engines (for CMM  
interface and remote KVM)  
Type of Testing  
Notes  
Sun Java Plugin 6.3  
Configuration 1 -Compatibility  
Sun Java Plugin 6.3 or above  
Client OS  
Type of Testing  
Notes  
Microsoft Windows* XP  
Professional, SP3  
Microsoft Vista* Business (32-bit )  
SP1  
Red Hat Enterprise Linux 5.0  
Desktop (32-bit)  
Novell SuSe Linux Desktop 10.1 (32-  
bit)  
Configuration 1 -Compatibility  
Configuration 1 -Compatibility  
Configuration 1 -Compatibility  
Configuration 1 -Compatibility  
Revision 1.9  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
3.1 Operating System Certifications  
Listed below are the operating systems that Intel plans to certify with the Intel® Compute  
Module MFS5000SI. However, the customer is responsible for their own certification from the  
individual operating system vendors. In many cases, the customer may leverage their operating  
system certifications from Intel’s testing. See the “Comments” section next to each operating  
system in the table below for additional information. Intel’s certifications, pre-certification, and  
operating system testing may help reduce some of the risk in achieving customer certifications  
with the operating system vendors.  
Table 3.2 Operating System Certifications  
Operating System  
Certification Listing  
Comments  
Intel® Modular Server  
System MFSYS25/  
MFS5000SI  
Microsoft Windows* 2003  
Enterprise Server (32 & 64-bit )  
Certification available at launch. OEM must request  
certification by Microsoft for their specific product.  
SID# 1270300  
Intel® Modular Server  
System MFSYS25/  
MFS5000SI  
Certification available.  
Microsoft Windows* 2008  
Enterprise Server (32 & 64-bit )  
OEM must request certification by Microsoft for their specific  
product.  
SID# 129928  
Certification available at launch.  
Intel® Modular Server  
System MFSYS25/  
MFS5000SI  
Red Hat checks Intel’s results, certifies (if appropriate), and  
posts the certificate on their web site. Customer can  
leverage the Intel certification, if customer product meets the  
operating system vendor standard.  
Red Hat* Enterprise Linux  
Adavanced Server 5.0 (32 &  
64-bit)  
SID# 385741  
Intel® Compute Module  
MFS5000SI  
YES Certification Bulletin’s can be located on Novell’s  
website.  
SuSE Linux Enterprise Server  
10 (32 & 64-bit), SP1  
YES Certification  
Bulletin 95560  
Intel® Compute Module Certification details available on SCO’s website:  
SCO UnixWare 7.1.4  
Intel® Compute Module Certification details available on SCO’s website:  
SCO OpenServer Release 6  
Virtualization Software  
MFS5000SI  
Certification Listing  
Comments  
This recipe is available only through the ESAA program.  
Please visit http://www.esaa-members.com to sign up  
VMware ESX Server 3.0.2 U1  
GA Certification  
NA  
This recipe is available only through the ESAA program.  
Please visit http://www.esaa-members.com to sign up  
VMware ESX Server 3.5  
VMware ESXi Server 3.5  
This recipe is available only through the ESAA program.  
Please visit http://www.esaa-members.com to sign up  
NA  
VMware ESX3.5 for  
MFSYS25/MFSYS35 Storage  
Pending  
Pending  
VMWare ESXi3.5 for  
MFSYS25/MFSYS35 Storage  
12  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
3.2 Operating System Storage Component Support  
Table 3.3 Operating System Storage Component Support  
Shared LUN  
Single SCM  
Shared LUN  
Dual SCM  
Operating System  
Single SCM  
Dual SCM  
Microsoft Windows* 2003 Enterprise (32-bit), R2  
SP2  
Microsoft Windows* 2003 Enterprise (64-bit), R2  
SP2  
Supported  
Supported  
Supported  
Not Supported  
Not Supported  
Not Supported  
Not Supported  
Supported  
Microsoft Windows* 2008 Enterprise (32-bit)  
Microsoft Windows* 2008 Enterprise (64-bit)  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Not  
Supported  
Red Hat Enterprise Linux AS 5.0 U1(32-bit)  
Red Hat Enterprise Linux AS 5.0 U1(64-bit)  
Not Supported  
Not Supported  
Not Supported  
Not Supported  
Supported  
Not  
Supported  
SuSE Linux Enterprise Server 10 U1 (32-bit),  
SuSE Linux Enterprise Server 10 U1(64-bit),  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported by  
vendor  
Not  
Supported  
SCO UnixWare 7.1.4  
Not Supported  
Not Supported  
Not Supported  
Not Supported  
Supported by  
vendor  
Not  
Supported  
SCO OpenServer Release 6  
VMWare ESX 3.5 U3  
VMware ESXi 3.5 U3  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Supported  
Revision 1.9  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
4. I/O Expansion Cards & Peripherals  
I/O Expansion card and peripheral compatibility and stress testing will only be performed with  
the latest version of an operating system at the time the validation testing occurred. The  
following table shows the operating system and base system configurations used to validate  
each device. The expansion cards and peripherals are divided into categories based on their  
functionality. All integrated on-board devices are tested by default and are therefore not  
included in the following tables.  
Note that not all expansion cards or peripherals were tested under all operating systems. The  
following notation is used in the tested adapters and peripherals table below to indicate the  
support level that Intel provides for a particular adapter under a particular operating system:  
This expansion card or peripheral has been tested and is supported under the specific  
Number (i.e. 1)  
configuration identified in the Base System Configurations Table in Section 2 of this  
document.  
This expansion card or peripheral has been tested, but is NOT supported under the  
Number in brackets (i.e. [1]) specific configuration identified in the Base System Configurations Table in Section 2  
of this document.  
This expansion card or peripheral has not been tested under this operating system  
and is not supported under this operating system.  
NT  
This expansion card or peripheral has not been tested under this operating system  
ND  
due to limitations in IHV driver availability, and is not suported under this operating  
system.  
This expansion card/peripheral is supported, but not tested. This expansion  
card/peripheral model has not been tested with this server board, but Intel will support  
it based on successful testing of a similar expansion card/peripheral from the same  
family. Intel has high confidence that this expansion card/peripheral will function  
correctly with the server board. This expansion card/peripheral uses the same  
firmware and drivers, and has a nearly identical system interface to another  
expansion card/peripheral of the same family that has been successfully tested with  
this server board. In addition, Intel has secured IHV commitment to support the  
similar expansion card/peripheral equally. Customers should always test expansion  
card/peripheral as part of the final system configuration prior to deployment. All  
installation guidelines for the tested expansion card/peripheral also apply to the  
similar device.  
SD (Similar Device)  
Any variations to the standard adapter installation process or to expected adapter functionality  
are documented in the Installation Guidelines section of this document. If there are installation  
guidelines affecting a particular expansion card/peripheral and operating system combination,  
these are referenced in the following table. If there are no installation guidelines noted in the  
following table, then the expansion card/peripheral installed and functioned as expected using  
manufacturer’s installation instructions or Intel’s best-known methods.  
14  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
Table 4.1 Intel® Compute Module MFS5000SI Supported Items  
Manufacturer  
Model Name  
Model Number  
Interface  
Comments  
4.1  
Ethernet Expansion Card  
Intel® Modular  
Server Accessory  
-- Dual GbE I/O  
Expansion  
Proprietary  
PCI - E  
Intel  
AXXGBIOMEZB  
1
1
1
1
MezzCard  
4.2  
Monitors  
19" LCD  
VX1935WM  
VX1935WM -  
VGA only  
Viewsonic  
Viewsonic  
Viewsonic  
VGA  
VGA  
VGA  
1
1
1
1
1
1
1
1
1
1
1
1
VAA 702- VGA  
only  
17" LCD VAA 702  
19" HD  
Widescreen  
VX1945wm  
19" Wide  
Viewsonic  
Multimedia LCD  
Display Monitor  
VA1912w  
VGA  
1
1
1
1
17" Multimedia  
Digital DVI LCD  
Viewsonic  
Viewsonic  
VP702b  
VA703b  
VGA  
VGA  
1
1
1
1
1
1
1
1
17" LCD Display  
Monitor  
4.3  
USB Devices  
F5U021v  
4 port hub  
Belkin  
USB Hub  
USB Hub  
USB  
USB  
1
1
1
1
1
1
1
1
CP  
CP-UH-315  
4 port hub  
Technologies  
Natural  
Ergonomic USB  
Keyboard  
Microsoft  
4000 V1.0  
USB  
1
1
1
1
Ergoboard Pro  
Keyboard  
Belkin  
Belkin  
F8E887-BLK  
USB  
USB  
USB  
USB  
USB  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
F8E814-BLK-  
OPT  
USB Mouse  
Optical USB  
mouse  
P/N: 931145-  
0403  
Logitech  
Logitech  
Logitech  
Optical USB  
Mouse  
M-BJ58  
M-UB48  
MiniWheel*  
Mouse  
Revision 1.9  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
Manufacturer  
Model Name  
Model Number  
Interface  
Comments  
TEAC  
USB Floppy  
FD-05-PUB  
USB  
1
1
1
1
1
1
1
1
NEC  
USB Floppy  
UF0002  
USB  
USB  
USB Storage  
Drive  
80GB Silver  
Portable  
IOMega  
1
1
1
1
1
1
1
1
USB Jumpdrive  
1GB  
Lexar  
Lexar  
USB Keyfob  
USB Keyfob  
USB  
USB  
USB Jumpdrive  
2GB  
SD  
SD  
SD  
SD  
USB Cruzer  
Micro 1GB  
SanDisk  
SanDisk  
IOMega  
Liteon  
Liteon  
Liteon  
Sony  
USB Keyfob  
USB Keyfob  
USB  
USB  
USB  
USB  
USB  
USB  
USB  
USB  
USB  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
USB Cruzer mini  
2GB  
DVD R/W  
(Super 16xU2)  
USB Optical Drive  
USB Optical Drive  
SHM-165P6SX  
USB Optical Drive SOSW-1673SU  
USB Optical Drive  
USB Optical Drive  
USB Optical Drive  
USB Optical Drive  
DX-20A4H  
DRX-830UL-G  
DRX-840U  
Sony  
HP  
DVD1040E  
16  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
Table 4.2 Intel® Modular Server System MFSYS25 Supported Peripherals  
Manufacturer  
Model Name  
Model Number  
Interface  
Comments  
4.4  
Ethernet Switch Modules  
Intel® Gigabit  
Gbit  
Ethernet  
Intel  
AXXSW1GBS  
1
1
1
1
1
1
1
1
Ethernet Switch  
Storage Controller Modules  
Intel® Storage  
4.5  
Intel  
Controller  
Module  
AXXSCM3SS  
SAS  
4.6  
External Tape Drives  
Tested by vendor.  
Intel tested with the  
following  
configurations:  
Windows 2003*  
with Symantec  
Backup Exec 11 &  
Windows 2008*  
with Symantec  
Backup Exec 12  
Quantum LTO-3  
LTO  
Drive  
Quantum  
LTO-3 HH SAS  
1
1
1
1
HH  
4.7  
External Storage  
Single storage  
controller  
Promise  
Promise  
VTrak E310sS  
VTrak E310sD  
VTrak E610sS  
VTrak E610sD  
VTE310sS  
VTE310sD  
VTE610sS  
VTE610sD  
SAS  
SAS  
SAS  
SAS  
1
1
1
1
1
1
1
1
1
NT  
1
1
1
1
1
Dual storage  
controller  
Single storage  
controller  
Promise  
Promise  
Dual storage  
controller  
NT  
Intel® Storage  
Server  
SSR212MC2  
Intel  
Intel  
SSR212MC2  
SSR212PP  
NAS  
GbE  
1
1
1
1
1
1
1
1
Intel® Storage  
Server  
SSR212PP  
SVPM v2.4 or  
above. Supported  
by vendor in single  
SCM configuration  
See  
comment  
See  
comment  
See  
comment  
See  
comment  
Xyratex  
Xyratex E5412E  
E5412E  
SAS  
Revision 1.9  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
5. Hard Disk Drives  
The hard drives listed in the following table have been tested with the Intel® Modular Server  
System MFSYS25 / MFSYS35 by Intel validation labs and/or by individual drive vendors. The  
following operating system identifiers are used in the table to specify which operating system  
each drive was tested under.  
Table 5.1 Tested Operating System Identifier Numbers  
Identifier Number Operating System  
1
2
3
4
5
6
7
Microsoft Windows* 2003 Enterprise (32-bit), R2 SP2  
Microsoft Windows* 2003 Enterprise (64-bit), R2 SP2  
Red Hat Enterprise Linux AS 5.0 U164-bit)  
SuSE Linux Enterprise Server 10 U1(32-bit),  
SuSE Linux Enterprise Server 10 U1(64-bit),  
Microsoft Windows 2008 Enterprise (64-bit)  
Red Hat Enterprise Linux AS 5.0 U1(32-bit)  
Not all hard drives were tested under all operating systems. The following notation is used in  
the tested hard drives table below to indicate the support level that Intel provides for a particular  
hard drive with a particular operating system:  
This hard drive has been tested and is supported under the operating system  
Number (i.e. 1)  
identified by the operating system identification number.  
This hard drive has been tested, but is NOT supported under the operating system  
Number in brackets (i.e. [1])  
identified by the operating system identification number.  
The hard disk drive is supported, but not tested. This hard drive model/capacity has  
not been tested with this server board, but Intel will support it based on successful  
testing of a larger capacity hard drive from the same hard drive family. Intel has high  
confidence that this hard drive will function correctly with the server board. This drive  
uses the exact same firmware and drivers as a larger capacity hard drive that has  
been successfully tested with this server board. The only difference between this  
drive and the one that was used in testing is the storage capacity. Intel provides the  
SD (Similar Drive)  
same level of support for all hard drives listed in this document, regardless of whether  
the drive was tested or not. Customers should always test hard drives as part of the  
final system configuration prior to deployment. Given the fact that a larger capacity  
hard drive from the same drive family has successfully completed testing on this  
server board, this particular hard drive capacity point will not be tested.  
The hard disk drive was tested according to Intel-approved guidelines and test  
procedures by the Independent Hardware Vendor (IHV) that manufactured the drive.  
Intel provides the same level of support for all hard drives listed in this document,  
regardless of whether the drive was tested in an Intel lab or not. IHV test reports  
IHVT (IHV Tested)  
18  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
This hard drive has been tested and is supported under the operating system  
Number (i.e. 1)  
identified by the operating system identification number.  
remain the property of the IHV (Intel cannot provide copies of these reports).  
Table 5.2 Tested Hard Drives  
Drive  
Drive  
Size  
(GB)  
Tested  
Operating  
System  
Product  
Family  
FW  
Level  
(a)  
Manufacturer  
Model Number  
RPM  
Notes  
MFSYS25, 2.5” SAS Hard Drives  
Seagate  
Seagate  
Seagate  
Seagate  
Seagate  
Savvio 2.5” ST9300603SS  
10,000  
10,000  
10,000  
15,000  
15,000  
300GB  
146GB  
73GB  
36GB  
73GB  
0002  
0003  
0003  
0001  
0001  
1,2,3,4,5  
1,2,3,4,5  
1,2,3,4,5  
1,2,3,4,5  
1,2,3,4,5  
Added March 2009  
SD  
Savvio 2.5”  
Savvio 2.5”  
Savvio 2.5”  
Savvio 2.5”  
ST9146802SS  
ST973402SS  
ST936751SS  
ST973451SS  
SD  
Chassis must be at UFU  
P2.6 FW level  
Fujitsu  
Fujitsu  
Fujitsu  
Fujitsu  
AL-10SE  
AL-10Sx  
AL-10Sx  
AL-10Sx  
MBB2147RC  
MBB2073RC  
MBC2036RC  
MBC2073RC  
10,000  
10,000  
15,000  
15,000  
146GB  
73GB  
36GB  
73GB  
0110  
0110  
1,2,3,4,5  
1,2,3,4,5  
1,6,7  
Chassis must be at UFU  
P2.6 FW level  
Chassis must be at UFU  
P2.6 FW level  
Chassis must be at UFU  
P2.6 FW level  
1,6,7  
MFSYS35, 3.5” SAS Hard Drives (b)  
Seagate  
Seagate  
Cheetah  
Cheetah  
ST3450856SS  
ST3300656SS  
15,000  
15,000  
450GB  
300GB  
0004  
0004  
1,2,3,4,5  
1,2,3,4,5  
Barracuda  
ES2*  
Added March 2009  
Seagate  
Seagate  
Fujitsu  
ST31000640SS  
ST3750630SS  
MBA3300RC  
7,200  
7,200  
1TB  
0003  
0002  
0103  
1,2,3,4,5  
1,2,3,4,5  
1,2,3,4,5  
Barracuda  
ES2*  
750GB  
300GB  
MBA  
Series  
Chassis must be at UFU  
P2.6 FW level  
15,000  
MFSYS35, 3.5” SATA Hard Drives *  
Barracuda  
Seagate  
Hitachi  
ST3500320NS  
7,200  
7,200  
500GB  
500GB  
SN05  
BOA  
1,2,3,4,5  
1,2,3,4,5  
ES2*  
Ultrastar  
A7K1000  
HUA721050KLA  
330  
(a) Firmware revisions listed in this column are the minimum revision levels supported. As they become available,  
listed drives with newer revisions of firmware are also supported. OEM specific versions of drive firmware are not  
supported. Mixed firmware levels within the same storage pool is not supported.  
(b) MFSYS35 currently does not support a mix of SAS and SATA drives within the same chassis. All drives within the  
MFSYS35 subsystem must have the same interface.  
Revision 1.9  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
6. Installation Guidelines  
6.1 Slipstreamed install for Windows 2003 Enterprise Edition (32 &  
64 bit)  
Method for performing Slipstreamed install for Windows 2003 Installation via  
CD-ROM drive. Both the CD-ROM and Floppy can not be simultaneously  
redirected on the MFSYS25 system.  
Implication:  
The MFS500SI compute module will only support remote installation of the  
Windows 2003 Enterprise Edition R2 SP2 slipstreamed version. Local installation  
can be performed by either concurrent CD/floppy installation or via slipstreamed  
installation CD.  
For remote install the LSI SAS driver must be slipstreamed into the installation  
media as both CD-ROM and Floppy can’t be simultaneously redirected.  
Guideline:  
To create a merged Windows 2003 CD perform the following:  
1. Download and install the freeware program nLite from  
(http://www.nliteos.com/index.html)  
2. Launch nLite  
3. Select language desired and hit next  
4. On the next screen browse to the location of the Windows 2003 CD  
5. nLite will prompt for a location to copy the CD to for modification (C:\temp),  
it’ll then copy the install CD to that folder  
6. When the copy completes, hit next  
7. Hit next on the presets screen  
8. On the next screen, select “Integrate -> Drivers” and “Create -> Bootable  
ISO”, hit Next.  
9. Download and extract the 1.25.5 driver for the appropriate version of the OS  
(32-bit or 64-bit) and extract to a known location  
10. Hit the Insert tab in the bottom left (single driver), browse to the location with  
the driver and select the “lsi_sas.inf”  
11. Select “Textmode driver”, click on the description in the box, and hit OK  
12. Hit Next to begin the process  
13. When the process completes, hit next to bring up the Bootable ISO screen  
14. Select the appropriate options for your system and hit “burn” to create the  
CD  
15. When finished, the CD is ready for remote installation with no requirement  
for a driver floppy  
Status:  
Intel has no plans to add support for concurrent Remote Floppy and Remote  
CD/DVD.  
20  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
6.2 Windows 2003 Enterprise Edition (32 & 64 bit) Remote  
Installation Method  
Method for performing Remote Windows 2003 Installation via CD-ROM drive.  
Guideline: Note: Prepare a Slipstreamed CD per section 6.1.  
1. Plug your slipstreamed CD of your Windows operating system CD-ROM into  
the CD on your remote system.  
2. Log in to the Modular Server and select the Storage Tab at the top.  
3. If you have not already done so create a storage Pool and select it.  
4. Select the Create Virtual Drive option under Actions.  
5. Enter a Name for the Virtual Disk.  
6. Select a Raid Level appropriate for your application. The Raid levels that are  
available will be dependant on the number of drives used to create the  
storage pool.  
7. Enter the size in GB for the virtual disk.  
8. Select the Server that the virtual disk will be assigned  
9. Select the Drive # for the virtual disk. For loading an operating system on a  
boot drive set the value to 0(boot device).  
Revision 1.9  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
10. Confirm all your settings then Hit Apply. Hit OK when the confirmation dialog  
is displayed.  
11. With the mouse, select the Chassis Front Tab.  
12. Click on Server 1 on the Chassis picture with the Mouse.  
13. Click on the Remote KVM & CD option under Server 1 Actions.  
14. Select the video display color resolution.  
22  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
15. Choose the Device Menu Option and then click on the CDROM check box.  
16. Choose the Redirect CDROM drive to select the CDROM on your system as  
the device to load the operating system from.  
17. Choose the drive letter of the CDROM to redirect the CD.  
Revision 1.9  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
18. Return to the Modular Server screen and select the Chassis Front TAB. Do  
not close out the KVM screen.  
19. Select Server 1 and then hit the Power On option under “Server 1” Actions.  
20. Select OK when requested to power on Server 1.  
21. Return to the KVM screen and observer the bootup screen.  
22. Continue with Windows setup following the directions for the operating  
installation.  
24  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
6.3 Red Hat Enterprise Linux 5.0 (32 & 64 bit) Remote Installation  
Method  
Method for performing Remote Red Hat Enterprise Linux 5.0 Installation with DVD  
media via FTP  
Guideline: Configure the MFSYS25 system as follows:  
1. Ensure P2.0.5 or later SW stack is loaded  
2. Management Module, Ethernet Switch (Ext 1 port and the compute  
module’s ports in default vlan 1 setup) and client (desktop/laptop) in  
the same network  
3. Client requires DVD unit installed direct or via USB port  
4. Disable client’s Firewall  
5. Download and install Filezilla-Server application on the client. Application can  
be downloaded from http://www.filezilla-project.org. Version test: 0-9.24  
6. When Filezilla Server is installed onto the client there will be a dialog popup  
7. Click OK with the default listing  
8. The Filezilla session should indicate “Logged on”  
9. From Filezilla Server session, Click Edit  
10. Select Users - The Users dialog pops up  
11. Click “Add”. A popup will appear - enter anonymous in the first field (user  
account). Accept default of <none> for second field then click OK.  
Revision 1.9  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
12. From Filezilla server session click “Shared Folders”, then click “Add”, navigate  
down and select the client’s DVD’s unit drive-letter, in the example case below  
it was E, then click OK.  
13. To verify your FTP setup is correct:  
Open client’s CMD prompt window and type:  
C:> ftp localhost  
26  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
User: anonymous  
Password: (just hit enter key)  
ftp> dir  
14. You should see the whole directory tree of the RHEL-5 DVD media you are  
trying to install from  
15. The Filezilla FTP server is now setup and ready to use  
16. Log in CMM-GUI  
17. Create a Storage Pool and Virtual Drive  
18. Assign to a compute module as LUN 0  
19. Via GUI select the compute module’s Remote KVM session and select CD-  
ROM Redirection and map to the DVD-drive-letter (x) on client  
20. Power on the compute module via GUI  
21. When presented with Red Hat Boot Option table, hit F2 then type following at  
the boot prompt:  
linux text askmethod  
Revision 1.9  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
or  
hit F2 then type same command there.  
28  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
22. When asked for Installation Method - Select FTP then click OK  
23. When asked for Networking Device - Select (hi-lite) eth0 as your main  
interface then click OK (Use TAB key to move around)  
24. When presented dialog Configure TCP/IP - Select IPv4 and deselect IPv6 and  
OK  
25. On the RedHat’s FTP Setup page, enter as:  
FTP site name: x.x.x.x (your client IP)  
RH Enterprise Linux Server Directory: /  
Revision 1.9  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
26. Select DHCP mode when asked for network configuration for Eth0 and Eth1  
30  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
6.4 SuSE Linux Enterprise Server 10 (32 & 64 bit) Remote  
Installation Method  
Method for performing SuSE Linux Enterprise Server 10 Installation via SMB  
Guideline: Configure the MFSYS25 system as follows:  
1. Ensure P2.0.5 or later SW stack is loaded  
2. Management Module, Ethernet Switch (1 port and with compute module  
ports in default vlan 1 setup) and client (desktop/laptop) in same network  
3. Client requires DVD unit installed direct or via USB port  
4. Disable client’s Firewall  
5. Share the client’s DVD-unit with “all read/write permissions”  
6. Log into CMM and via GUI create a Storage Pool and Virtual Drive and  
assign it to the compute module as LUN 0.  
7. Via GUI select the compute module’s Remote KVM session and select CD-  
ROM Redirection and map to the DVD-drive-letter (E) on client  
8. Select Video color resolution = High  
9. Power on the compute module via the GUI  
Revision 1.9  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Intel® Modular Server System MFSYS25, Intel® Modular Server System MFSYS35, Intel® Compute  
Module MFS5000SI  
10. When server boots to the option table, use down-arrow key to select  
second option from the given list “Installation” then type (Boot Options line):  
install=smb://x.x.x.x/drive-letter  
where:  
x.x.x.x  
: your client’s IP  
drive-letter : the client’s DVD unit drive letter assigned by OS (in  
example it is E)  
11. The installation process will result in a reboot in about 25 minutes  
12. The whole SLES installation will finish in about 45 minutes  
32  
Revision 1.9  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Jacuzzi Hot Tub EH85 User Manual
JDS Uniphase Electronic Accessory 230201 User Manual
JVC Stereo Receiver RX DP20VBKC User Manual
JVC Universal Remote DR DX5SE User Manual
Jwin MP3 Player JX CD530 User Manual
Kenwood Car Stereo System DDX8029 User Manual
Kenwood DVD Player DV 6050 User Manual
Kenwood Marine Radio TM V7A E User Manual
KitchenAid Ice Maker KUIC18NNTS0 User Manual
Konica Minolta Printer C250P User Manual