Infinity Personal Lift CPG INFVER01 User Manual

®
INFINITY  
Residential Elevator  
Roped Hydraulic Residential Elevator  
Planning Guide  
ASME A17.1 - 2000 Part 5 Section 5.3  
CAN/CSA B44 - 2000 Part 5 Section 5.3  
Effective April 1, 2004  
®
Download from Www.Somanuals.com. All Manuals Search And Download. ELEVATORS and LIFTS  
INFINITY  
Equipment for Residential Elevator  
Residential Elevator  
This elevator meets the requirements of  
ASME A17.1 Part 5, Section 5.3 and CAN/CSA B44 Part 5, Section 5.3  
for a Residential Elevator  
General  
Safety Devices  
Rated Load: 750 lbs. (340kg) or 1000 lbs. (454kg)  
Nominal Speed: 36 fpm (.18 ms)  
2 Stop up to 10' travel (Up to 50' optional)  
Data Plates, capacity tags and rope tags  
Minimum pit depth: 8" (203mm)  
Minimum overhead clearance: 92" (2337 mm)  
Presentation drawings  
Easy access emergency manual lowering  
Upper and lower terminal limits  
Manual reset slack rope safety switch  
Automatic bi-directional leveling  
Anti creep device  
Pit switch  
Pump run timer  
Car top stop switch  
Emergency battery back-up for lighting, alarm and  
lowering  
Mechanical Equipment  
208/230V, 60 Hz, 30 Amp single phase power supply  
8 lb. T-Rail system  
Two 3/8" diameter wire rope cables  
Sling assembly  
Cab gate safety switch  
Other Options - All Models  
Automatic cab gate operator  
Forged rope sockets  
Automatic operators for hoistway doors  
Various styles of interlocks for hoistway doors  
90 degree entry/exit cab  
2 Exit openings at one landing  
35" x 54" or 35" x 60" cab sizes  
96" (2743 mm) high cab  
3 or 4 stops with up to 50 ft. (15.24 m) of travel  
Finished oak hardwood flooring  
Two piece hydraulic jack for lifting heights exceeding  
32 ft. (9.75 m)  
Roped Hydraulic Drive  
1:2 roped hydraulic single stage cylinder  
3 hp submersed motor with two speed valve  
assembly  
Standard Cab and Appointments  
Cab Size: 35" (914 mm)W x 48" (1219 mm)L  
x 80" (2032 mm)H (inside clear measurements)  
Cab Walls: ½" (13 mm) Melamine or M.D.F. panels  
with black anodized aluminum trim  
Cab Ceiling: Architectural white steel ceiling with four  
(4) recessed incandescent down lights  
Solid oak handrail painted black  
Stainless steel flush mounted cab operating panel  
Digital floor and directional indicator (optional on SRE)  
Illuminated cab operating buttons  
Other Options – Infinity Luxury Model  
Recessed telephone cabinet in stainless steel or  
brass  
Various panel-fold cab gates or black scissor gate  
Custom cab sizes up to 15 sq.ft. (1.39 sq. m)  
Solid cherry, maple or oak raised panel walls and  
ceiling  
Recessed plywood flooring  
Telephone jack  
Thermofoil red apple, honey apple, pine or white ash  
raised panel walls and ceiling  
Controls  
Solid state (Plug n' Play) controller  
Fully automatic operation  
Constant pressure operation available  
Stainless steel rectangular hall call stations  
Automatic cab lighting with battery back-up operation  
Emergency alarm and stop button  
Floor specific battery lowering  
Unfinished oak veneer walls and ceiling  
Brass or Designer cab operating panel  
Brass rectangular or oval hall/call stations  
Stainless steel oval hall/call stations  
Unfinished or finished oak handrail  
Cylindrical brass or stainless steel handrails  
Recessed brass down lights  
Clear or brass anodized cab trim  
5 stops – requires PLC Controller Package  
Magnetic tape reader for floor selection and levelling  
Automatic home landing to pre-selected floor  
CPG-INFVER01 © 2004, Concord Elevator Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 3 of 12  
INFINITY  
Hoistway and Cab Configurations  
Residential Elevator  
Choice of Five Variations  
Important Note: Finished hoistway dimensions must include the drywall. Determine the fire  
rating of the hoistway, the type and layers of sheet rock and build only off shop drawings  
specific to your project.  
Available Cab Dimensions (Clear Inside):  
35" x 48"  
35" x 54"  
35" x 60"  
Type 1 (S) - Enter/Exit Same Side  
Type 2 (W) - Enter/Exit Opposite Side  
LENGTH  
LENGTH  
Clear Cab  
Length  
48"  
Finished  
Hoistway Length  
54 3/4"  
Clear Cab  
Length  
48"  
Finished  
Hoistway Length  
56 1/4"  
54"  
60 3/4"  
54"  
62 1/4"  
60"  
66 3/4"  
60"  
68 1/4"  
X
X + 6 3/4"  
X
X + 8 1/4"  
Type 3 (WS) - 90o Enter/Exit  
Type 4 (WS) - 90o Enter/Exit  
LENGTH  
LENGTH  
see chart  
see chart  
Clear Cab  
Finished  
Side Entrance  
Clear Cab  
Finished  
Side Entrance  
Length  
48"  
Hoistway Length Center Lines  
Length  
48"  
Hoistway Length Center Lines  
56 7/8"  
33 7/8"  
56 7/8"  
33 7/8"  
54"  
62 7/8"  
39 7/8"  
54"  
62 7/8"  
39 7/8"  
60"  
68 7/8"  
45 7/8"  
60"  
68 7/8"  
45 7/8"  
X
X + 8 7/8"  
X + 14 1/8"  
X
X + 8 7/8"  
X + 14 1/8"  
CPG-INFVER01 © 2004, Concord Elevator Inc.  
Page 4 of 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFINITY  
Hoistway and Cab Configurations  
Residential Elevator  
Type 5 (S) - Enter/Exit Same Side  
Diagram of Elevator Shaft  
(Opposite Sling)  
Overhead  
Elevator  
Guide  
Rails  
LENGTH  
Hydraulic  
Lifting  
Cylinder  
3/8" Wire  
Rope  
Cable  
Elevator  
Cab  
Cab  
Operating  
Panel  
see chart  
Clear Cab  
Finished  
Side Entrance  
Length  
48"  
Hoistway Length Center Lines  
Cab Gate  
Pit  
54 1/4"  
27 1/8"  
54"  
60 1/4"  
30 1/8"  
60"  
66 1/4"  
33 1/8"  
X
X + 6 1/2"  
(X + 6 1/4") / 2  
Hoistway Overhead Clearance  
Infinity Cab Height  
80" Cab Height  
Overhead Clearance Requirements  
92" Minimum Clear Overhead  
96" Cab Height  
108" Minimum Clear Overhead  
Typical Hydraulic Drive Machine Room Layout  
Machine room must be built in accordance with  
local, state/provincial and national codes.  
Machine room lighting shall be a minimum of 19  
foot candles at working surfaces. The switch for  
the light must be within 18" of the strike side of the  
machine room door. The switch, light and wiring  
are provided and installed by others. A  
convenience outlet, 115 VAC 15 AMP single  
phase with G.F.I. shall be located next to the light  
switch in the machine room. provided and installed  
by others. NEC requires a 30" wide x 36" deep  
work space in front of the disconnects and the  
elevator controller.  
A telephone line circuit is to be provided and  
installed by others. This circuit must be connected  
to an outside line.  
Machine Room Plan at Lower Level  
Controller/Pump Unit Dimensions = 30"W x 16"D x 55"H  
CPG-INFVER01 © 2004, Concord Elevator Inc.  
Page 5 of 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFINITY  
Specifications for Part 5.3 Compliance  
Residential Elevator  
PART 1 - GENERAL  
PART 2- PREPARATORY WORK BY OTHERS  
2.1  
SCOPE  
The following preparatory work to accommodate/receive the elevator is to  
be done by others.  
To furnish all labor, materials and equipment necessary or required to  
fully complete the installation of the elevator as indicated on the  
Drawings and Specifications. This suggested specification is intended to  
cover the complete installation of the Concord INFINITY Residential  
Elevator design.  
2.1.1  
Provide power unit machine room to meet applicable Codes and  
Standards.  
SYSTEM DESCRIPTION  
2.1.2  
Permanent power (220 Volt, Single Phase, 30 Amp or 208 Volt, 3 Phase,  
30 Amp.) to operate the elevator to be provided to a Lockable  
Fused/Cartridge Type Disconnect Switch with auxiliary contact/switch for  
emergency battery lowering. Refer to architectural drawings for  
permanent power specifications and location of disconnects.  
The elevator assembly shall consist of a power unit, car, guide system,  
1:2 cable hydraulic lifting device, control system, signals and alarms,  
electrical wiring, and parts and accessories necessary to provide  
required performance, operation, code and safety requirements.  
QUALITY ASSURANCE  
2.1.3  
Provide 110-volt lighting supply and disconnect. Refer to architectural  
drawings for permanent power specifications and location of disconnects.  
1.3.1  
The elevator shall meet or exceed the applicable regulations of all  
governing agencies and be in conformance with the applicable sections  
of the most current edition of the following codes and standards:  
a) ASME A17.1 "Safety Code for Elevators and Escalators;  
"Private Residence Elevators". CAN/CSA B44 Part 5 Section 5.3  
b) ICC/ANSI A117.1-1998 "Accessible and Usable Buildings and  
Facilities".  
2.1.4  
Provide an enclosed, plumb and square hoistway with smooth interior  
surfaces. Include for fascias or furring of hoistway interior where  
applicable.  
2.1.5  
c) NFPA 70-1999 "The National Electric Code" (NEC).  
d) ADAAG "Americans With Disabilities Act Accessibility  
Guidelines" (where applicable).  
Provide doors, frames, and door hardware.  
Provide rough openings as per elevator contractor’s drawings.  
e) CSA B44.1/ASME A17.5 "Elevator and Escalator Electrical  
Equipment"  
f) Local codes and regulations, as applicable.  
2.1.6  
Provide substantial, level pit floor slab to support loads indicated on  
elevator contractor’s shop drawings.  
1.3.2 REQUIREMENTS OF THE REGULATORY AGENCIES  
a) Fabricate and install work in compliance with all applicable  
jurisdictional authorities.  
2.1.7  
Provide adequate support for guide rail fastenings.  
b) File shop drawings and submissions to local authorities as the  
information is made available. Company pre-inspection and  
jurisdictional authority inspections and permits are to be made  
on a timely basis as required. Work will include all inspections  
and re-inspections that are required to ensure licenses are  
issued.  
2.1.8  
Provide pit water proofing to maintain a dry pit. Sump pump where  
required by authority having jurisdiction. (see elevator contractor for  
location).  
2.1.9  
Provide 8" (203 mm) minimum pit.  
1.3.3 SUBCONTRACTOR QUALIFICATIONS  
a) Execute work of this specification only by a contractor/company  
who has adequate product and public liability insurance in  
excess of one million dollars.  
2.1.10  
Provide 92" (2337 mm) minimum overhead (distance from floor at upper  
level to underside of roof).  
b) Skilled tradesmen must be employees of the contractor and  
perform the work on a timely basis. Employees must be trained  
by the manufacturer and be supervised by the elevator  
contractor.  
PART 3 – SUBMITTALS  
3.1 SHOP DRAWINGS (presentation)  
The shop drawings shall show a complete layout of the elevator  
equipment detailing dimensions, clearances and location of machinery.  
Including the following:  
1.3.4 SUBSTITUTIONS  
No substitutions will be considered unless written request for approval  
has been submitted by the bidder and received by the architect at least  
10 days before the receipt of bids. Each such request shall include a  
complete description of the proposed substitute including drawings, test  
data, photographs, and any other information needed for consideration.  
a) Drawings show the dimensions including plans,  
elevations, and sections to show equipment locations.  
b) Load and reaction drawings shall be provided by the elevator  
manufacturer and detailed on drawings.  
CPG-INFVER01 © 2004, Concord Elevator Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 6 of 12  
Continued  
INFINITY  
Specifications for Part 5.3 Compliance  
Residential Elevator  
PART 4 – PRODUCT DATA  
4.2.10 AUTOMATIC LIGHTS  
Overhead lights in the car compartment shall turn ON automatically when  
the elevator door is opened and will stay on while the elevator is in use.  
The elevator lights will shut off by a timer when the elevator is not in use.  
4.1 MANUFACTURER/PRODUCT  
The elevator shall be the CONCORD INFINITY Residential Elevator  
manufactured by Concord Elevator Inc. Toll Free (800) 661-5112 and  
(905) 791-5555, Fax (905) 791-2222  
4.3 DOOR LOCKS  
Dealer Name ___________________________________  
Number _______________________________________  
Rated Load: 750 lbs. (340 kg.)  
Nominal Speed: 36-fpm (0.18 m/s)  
Car Dimensions: 36" W x 48" D (914 mm W x 1220 mm D)  
Operation: Automatic  
Locks shall be electrically operated and electrically released at floor level  
and will remain unlocked until hall or car call is placed. When released,  
the locks’ lag member will drop down and close the electrical circuitry to  
ensure the elevator cannot move unless the door is closed and locked (a  
true interlock).  
Gate Type: Horizontally collapsible, accordion style with 3 vision panels  
Power Supply: 220 Volt, Single Phase, 30 Amps or 208 Volt, 3 Phase,  
30 Amps  
4.4 HALL CALL STATIONS  
Provide a keyless hall call station with an illuminated call button and  
stainless steel cover plate for each landing.  
Travel Distance: 50 ft. (15.2 m) max __________________  
Levels Served: (up to 5, max. 4 - SRE) ________________________  
Number of Openings: Two (2) Maximum  
Lighting Supply: 110 Volt, 1 Phase, 60 Cycle, 15 Amps  
Jack Type: 1:2 Cable Hydraulic  
4.5 PLATFORM TOE GUARD  
A platform toe guard shall be provided at each car entrance opening to  
extend below the car entrance opening for safety.  
Pump Type: Submersible with Variable Speed Valve Levelling  
Device Type: Magnetic  
4.6 LEVELING DEVICE  
a) The elevator shall be provided with a 2-way leveling device, which  
will maintain the car within 1/2" (13mm) of the landing.  
b) Levelling device sensors shall be located in a position to  
be inaccessible to unauthorized persons.  
4.2 CAR ENCLOSURE  
4.2.1 WALLS  
1/2" (13 mm) Melamine panels and black anodized aluminum trim.  
4.7 CAR GATE REQUIRED OPTION  
Horizontally collapsible accordion style woodfold car gate with rattan  
panels and three (3) clear acrylic vision panels car gate shall enclose  
each car entrance.  
4.2.2 CEILINGS  
Architectural white with four (4) recessed incandescent down lights.  
4.2.3 FLOOR  
4.8 HYDRAULIC POWER UNIT  
Plywood sub-flooring.  
a) The pump and motor shall be the submersible type installed  
inside the oil tank.  
4.2.4 HANDRAIL  
Black painted oak handrail located on control panel.  
b) The controller shall be integrally mounted on the power unit  
frame and pre-wired and tested before shipment.  
c) Control circuitry to be located at the top of the oil tank.  
d) The power unit control valve shall be a variable speed  
proportional valve type that includes all hydraulic control valving  
inherently.  
4.2.5 EMERGENCY OPERATION  
The elevator car shall be equipped with a battery-powered emergency  
lowering device and alarm that can be actuated on the failure of normal  
building power supply. Battery will be rechargeable type with an  
automatic recharging system.  
This valve shall incorporate the following features:  
(i) Up and down acceleration and deceleration speed adjustment for  
smooth starts and stops.  
4.2.6 EMERGENCY LIGHT  
The car shall be equipped with an integral emergency light that will  
illuminate automatically in the event of a main power failure.  
(ii) Smooth stops at each landing shall be an inherent feature of the  
valve.  
(iii) Adjustable pressure relief valve.  
(iv) Manually operating 'DOWN' valve to lower elevator in an  
emergency.  
(v) Pressure gauge indicating in P.S.I. and Bars.  
(vi) Gate valve to isolate cylinder from pump unit.  
(vii) Negative pressure switch.  
4.2.7 CAR OPERATING PANEL  
Car operating panel shall consist of metal push buttons with halo  
lighting for each landing, an emergency stop button, an alarm button  
and a key switch. The key is removable in both the on and off position.  
All mounted on a #4 finished stainless steel panel. Car station panel is  
hinged.  
4.9 CYLINDER AND PLUNGER  
4.2.8 DIGITAL FLOOR INDICATOR  
4.9.1  
Digital floor indicator located in the control panel will display the  
location and direction of travel (floor number) of the elevator in the  
shaft. (optional on SRE model)  
The cylinder shall be constructed of steel pipe of a sufficient thickness  
and suitable safety margin. The top of the cylinder shall be equipped with  
a cylinder head with an internal guide ring and self-adjusting packing.  
4.2.9 CAR LIGHTING  
4.9.2  
The car lighting shall consist of four (4) low voltage recessed  
incandescent down lights. The failure of one lamp shall not cause the  
remaining lamp to extinguish.  
The plunger shall be constructed of a steel shaft of a proper diameter  
machined true and smooth. The plunger shall be provided with a stop  
electrically welded to the bottom to prevent the plunger from leaving the  
cylinder.  
CPG-INFVER01 © 2004, Concord Elevator Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Page 7 of 12  
Continued  
INFINITY  
Specifications for Part 5.3 Compliance  
Residential Elevator  
4.15.3  
4.10 CABLE  
Guides shall be bolted through the hoistway enclosure with back-up  
Minimum of two 3/8" (10 mm) IWRC Galvanized Aircraft Cables.  
Minimum breaking strength of 14,400 lbs. each.  
plates, washers and nuts. Subject to architects’ alterations and approval.  
4.16 CAR SLING  
4.11 SAFETY DEVICE  
A "slack/broken cable" safety device shall be supplied which will stop  
and sustain the elevator and its rated load, if either of the hoisting cables  
become slack or breaks. The safety device shall be resettable by the  
operation of the elevator in the upward direction. A switch shall be  
mounted in such a position as to sense the operation of the safety  
device, and will open the safety circuit to the controller to prevent  
operation of the elevator in either direction.  
4.16.1  
Car sling shall be fabricated from steel members with adequate bracing to  
support the platform and cab.  
4.16.2  
The buffer-striking member on the underside of the car must stop the  
elevator before the jack plunger reaches its down limit of travel.  
4.12 GUIDE YOKE  
4.16.3  
The 1:2 guide yoke/sheave arrangement shall be supplied with a  
sheave, guide shoes, roller bearings and adjustable cable guards. The  
sheave shall be finished with rounded grooves to fit the cables.  
Guide shoes to be solid slipper type with polyurethane inserts.  
4.17 WIRING  
All wiring and electrical connections shall comply with applicable codes,  
insulated wiring shall have flame retardant and moisture proof outer  
covering and shall be run in conduit or electrical wireways. Traveling  
cables shall be flexible and suitably suspended to relieve strain.  
4.14 FINAL LIMIT SWITCH  
The elevator shall be equipped with a final limit switch to cut off all power  
to the elevator if the upper normal terminal stopping devices fail.  
4.15 GUIDE RAILS AND BRACKETS  
Part 5 - EXECUTION  
4.15.1  
5.1 EXAMINATION  
All site dimensions shall be taken to ensure that tolerances and  
clearances have been maintained and meet local regulations.  
Steel 8lb/ft "T" guide rails and brackets shall be securely fastened to the  
building structure.  
4.15.2  
5.2 PREPARATION  
Brackets shall securely hold the guides in a plumb and true position  
regardless of car loading.  
Pre-inspect the construction and service requirements for "Work by  
Others". These requirements will be included in drawings, diagrams,  
engineering data sheets and special instructions before the work  
commences.  
Rail Reactions  
Rail Orientation to Support Wall  
R1 = 304 LBF  
R2 = 194 LBF  
Rail reactions do not include safety factors.  
Applicable safety factors must be considered  
in hoistway design.  
Typical Lower Rail Bracket Configuration  
CPG-INFVER01 © 2004, Concord Elevator Inc.  
Page 8 of 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFINITY  
Wood Hoistway Construction  
Residential Elevator  
Suggested Support Wall  
Wood Construction  
Note:  
The drawings on this page  
are for reference only.  
Building structural engineer  
to ensure that the building  
and hoistway will support  
all loads imposed by the lift  
equipment.  
Fire rating of hoistway is  
subject to local building  
codes.  
CPG-INFVER01 © 2004, Concord Elevator Inc.  
Page 9 of 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFINITY  
Wood Construction Sectional View  
Residential Elevator  
Wood Construction Plan View  
Rail Bracket  
CPG-INFVER01 © 2004, Concord Elevator Inc.  
Page 10 of 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFINITY  
Masonry Construction Elevation View  
Residential Elevator  
BLOCK WALL  
(8" MINIMUM)  
Masonry Construction Plan View  
Rail Bracket  
Note: For 8" Block  
Use Thru Bolts  
CPG-INFVER01 © 2004, Concord Elevator Inc.  
Page 11 of 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INFINITY  
Elevator Rail Support Wall  
Residential Elevator  
Drawing Notes  
1
2
See Elevator Drawing for rail bracket spacing and pit depth.  
Wall lateral support spacing:  
- for 2" x 4" studs, use 6' -10" (2090 mm) max.  
- for 2" x 6" studs, use 13' -6" (4120 mm) max.  
Sheathing installation: install sheets vertically full width of shaft or min.  
centred on rail brackets.  
Connectors to resist horizontal load but allow vertical movement.  
For Wood, use 2" x ¼" cap screw lag bolts.  
3
4
General Specifications  
G1 The design and construction of all work is to conform to the local applicable building code.  
G2 Read these drawings in conjunction with all related architectural, mechanical, electrical, and  
elevator drawings as well as any other contract documents.  
G3 The wall drawings have been prepared using engineering principles and the design loads that are  
applied by the elevator rails to the wall. However, the details and member sizes and the  
attachments to the structure should not be construed as a complete design of the wall system.  
The contractor and/or the project engineer is responsible to evaluate the other loads that are  
applied to the wall from the floor or roof system and modify member sizes or connections as  
required by their analysis.  
G4 Do not scale the drawings.  
G5 See elevator shop drawings for service loads (including dynamic effects)  
which are:  
- horizontal load parallel to the wall = 194 lb.  
- horizontal load perpendicular to the wall = 304 lb.  
G6 Wood  
SPF NO 1/2 Mix  
Concrete  
A. Bolts  
Mortar  
3000 psi (20 Mpa) @ 28 days. If exposed use 5% to 7% air content.  
ASTM A307  
Type “S”  
Masonry  
Grout  
Block  
2100 psi (14 Mpa) High Slump  
2100 psi (14 Mpa) on net area  
G7 Wall to be installed plumb and square within 1/8" (3mm) of top and bottom of shaft.  
G8 Wall lateral support spacing (H) selected for maximum horizontal deflection of H/360 from rail  
loads.  
Wood Construction  
W1 Separate wood from concrete with waterproof barrier or use pressure treated wood.  
W2 Bridging Maximum Spacing: Load Bearing or Shear walls – 4' c/c  
W3 Nail or screw sheathing at 6" c/c at edges and 12" c/c to other members.  
Use 2.5" Standard Ardox nails or 2" #12 Screws.  
Masonry Construction  
M1 All masonry construction to conform to applicable local standards  
M2 Reinforce lintel blocks with 2-15m bottom bars unless noted.  
M3 Provide continuous ladder type joint reinforcement at 16" (400) c/c.  
®
1-800-661-5112  
ELEVATORS and LIFTS  
CPG-INFVER01 © 2004, Concord Elevator Inc.  
Page 12 of 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Invacare Camping Equipment CG9701 User Manual
Jabra Bluetooth Headset HALO2 User Manual
JBL Professional Computer Hardware DSC 280 User Manual
John Deere Compact Excavator 240D LC User Manual
JVC Car Stereo System KS R600 User Manual
JVC Projector DLA M2000LU User Manual
JVC Stereo System CA HXZ55D User Manual
Kalorik Vacuum Cleaner USK HVC 1 060104 User Manual
Kenwood Stereo System 855 AV User Manual
Keys Fitness Treadmill CZE User Manual